ONLINE TESTING OF BOILER SAFETY VALVES.
2020_NALCO_558371_1
MC-4908
Open Tender
Miscellaneous Services
Item Rate
1095 days
CPP, NALCO, ANGUL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
NATIONAL ALUMINIUM COMPANY LIMITED
₹10,000
Yes
19 May 2021
9 May 2020
7 Jul 2020
9 May 2020
30 Jun 2020
9 May 2020
Amount
Trevi test of Drum & MS Safety Valves: Online Testing (Lifting/Set pressure setting, without actual full floating) of Drum & Main Steam (M.S) line safety valves (i.e. 3 nos per Unit) of our Boilers by TREVITEST / Equivalent test method. You will be offered 3 nos of Safety valves on each occasion (Usually after Annual Overhauling or in case of Short Shut down for Boiler License Extension purpose) for testing. Time is the essence in this testing work, since the Boiler will be kept running on oil firing to maintain a base line pressure of about 85 to 90 % of Lowest set pressure value. The total time period for testing for 3 safety valves should preferably be about 1 hour to 1.5 hour. Make :All valves are of BHEL make, M/S Dresser design (1700 series).
Trevi test of Re-heater Safety Valves: Online testing (Lifting/Set Pressure setting without actual full floating) of CRH & HRH steam line safety valves of our Boilers by TREVITEST / Equivalent method. You will be offered 3 nos of safety valves for test per visit. Line Pressure for all these valves (in full load condition) is about 30 Kg/ cm2. Make :All valves are of BHEL make, M/S Dresser design (1700 series).
Trevi test of Turbine side Safety Valves: Online testing (Lifting/Set Pressure setting without actual full floating) of Turbine side low pr. steam line safety valves by TREVITEST / Equivalent method. You will be offered minimum 3 nos of safety valves for test per visit.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .