The Deputy Executive Engineer, Electrical (R&B) Sub Division Botad,
Repairing and shifting of old solar power project installed at jilla seva sadan botad., dist. Botad [2nd attempt]
352082
E Tender 5 of 2026-27 (2nd Attemp)
Open
Electrical
Works
Botad
9 documents required · 9 mandatory
₹900
The Executive Engineer, Electrical R&B Division, Bhavnagar.
₹7,000
4 Oct 2026
4 Oct 2026
4 Oct 2026
17 Oct 2026
4 Oct 2026
Repairing and shifting of old solar power project installed at jilla seva sadan botad., dist. Botad
SR NO. ITEM QTY UNIT NET IN WORDS TOTAL
Replacing old & u/s by S.I.T.C of Solar Inverter Gried Tied: MPPT
Range: 80-1000 V, Max efficiency: 97.5% - 98.9%, O/p Frequency:
50/60Hz, Operating Altitude (m) ≤4000, O/p Power Factor: ~1, O/P
THDi: <3%, Operating Tempreture Range: -25~60°C, Anti-islanding
Protection: Integrated, Input Reverse Polarity Protection Integrated,
Insulation Resistor Detection Integrated, Residual Current
Monitoring Unit Integrated, Output Over Current Protection Rupees Eight Thousand
1 Integrated, Output Short Circuit Protection Integrated, Output Over
Voltage Protection Integrated, Protection Degree: IP65, User
Interface LCD & APP,Datalogger & Communication: GPRS / Wi-Fi
(Optional), (E) Solar Inverter: 50 kW: Max. input Current: 30 A, Max
DC i/p Power: 22100-51500 W & Nominal o/p Power: 25000-
50000W, Nomimal O/p Voltage: 400 V 3-Phase,Nominal O/p Current:
Replacing old & u/s by DC Cable: Electron beam cross linked
compound,UV, Ozone, Temperature & Hydrolysis resistant Flame
Retardant, Low Smoke Excellent Encapsulation
Very long / Service life >
Standards / Material Properties:
Fire performance : IEC 60332-1-2
Smoke emission : IEC 61034/ EN 50268-2 Rupees Seventy Six And
2 Halogen Free: EN 50267-2-1/-2, IEC 60754-2
Paise Seventy Six Only
Toxicity: EN 50305, ITC – Index <3
Ozone Resistant : EN50396
Weathering UV: HD 605/A1 or DIN
Approvals : EN 50618; H1Z2Z2-k
with suitable sized of PVC pipe(ISI Mark) and Clamps,Shadels,Lugs.
(A) 1 core 4 sqmm copper DC cable Colour Red
Rupees Seventy Six And
(B) 1 core 4 sqmm copper DC cable Colour Black 500 PER MTR 76.76
Paise Seventy Six Only
Replacing old & u/s by S.I.T.C of Distribution board from AC Side
,ACDB 3-Phase - 50 kW: AC1 DUTY CONTRACTOR-80A 4P,
Rupees Eighteen Thousand
100A MCCB 4P(Cat III), 3 PHASE SPD, VOLTAGE MONITORING RELAY,
3 ELR WITH CBCT, PHASE INDICATING LAMP, POWER CABLE &
1 Ea 18146.67 One Hundred Forty Six And
Paise Sixty Seven Only
OTHER ACCESSORIES, All switchgears and connection are enclosed
with IP66 Enclosure and operate the position.
Replacing old & u/s by S.I.T.C of Distributiob System DC Side, DCDB -
Rupees Twenty Four
50 kW - 65 kW (12in:12out) : Input Mcb - 1000 V, 16 Amp,
Thousand Nine Hundred
4 1000 V DC SPD TYPE 2, TERMINAL/END,PLATE/END CLAMP: 1 Ea
Ninety Four And Paise
4SQMM (KUT6) FOR OUTPUT, DC CABLE With suitable size of
Forty Seven Only
interconnection.
Supplying & Errecting MC4 Connector Male - Female Set for Solar DC Rupees Fifty Two And Paise
5 Cable which is installed in Solar PV-module/Inverter/DCDB etc.
Replacing old & u/s by Supplying and Erecting Seamless Box Pipe of
suitable size for rooftop solar installations with good stability agaist
wind, Thickness 2 mm and 80 micron, Hot Dipped Galvanized steel
coils. suitable arrangement for base plate for foundation , solar
Rupees One Hundred
panel mounting, the structure should be suitable for carry the load
6 of solar panel,wiring, sprinkler system etc. with necessary
1200 per kg 131.3 Thirty One And Paise Thirty
foundation work/wall mount, j bolt, anchor fastner etc. the nut bolt
used for installtion of stucture should be (SS 304) quality.
box. pipe ref. size (A) 40 x 40 x 2mm, (B) 50 × 50 × 2mm, (C.) 60 x
AMOUNT PUT TO TENDER FOR RS
Rupees Six Lakh(s) Eighty Nine Thousand Three Hundred Thirty Nine And Paise Fourteen Only
(A) Total Tendered Amount Rs..…..……………….…………...…………….
(B) Rebate on above tendered amount (if any)………………..…..%(in Figure) Rs….………………….………………………...
(C) Net tendered amount (A-B) Rs……………………………………………….
All work shall be carried out as per Public Works Department Handbook and other specification of Division or as directed
Rates quoted include clearance of site (prior commencement of work and at its close) in all respects and hold good for work under all
conditions, site, moisture, weather etc.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
DISMENTAL solar.pdf
nivida-5.pdf
SBD WTIH ELE BOOKLET FOR DEE LEVEL (3).pdf
sch-a SOLAR.pdf
sch-b SOLAR 1.pdf
solar power project condition.pdf
tender details jilla seva sadan solar.pdf
tender details solar.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .