The Executive Engineer Electrical HEED Harbour Eng
O/o The chief Engineer, Harbour Engineering Electrical Division, Kamaleswaram, TVPM
PMMSY_Modernisation of Fishing Harbour at Puthiyappa in Kozhikode District _ Providing Additional Flood light Minimast system_Electrification work
2023_HED_594791_1
13/HEED/2023-24/e-T/S
Open Tender
Electrical Works
Item Rate
90 days
PUTHIYAPPA
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,760
₹50,000
13 Oct 2023
10 Aug 2023
19 Aug 2023
10 Aug 2023
17 Aug 2023
10 Aug 2023
Amount
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
Supply of 2 core 2.5 sq mm PVC insulated and PVC sheathed armored copper control cable
Supply of 63/50mm (OD/ID) Double Walled Corrugated (DWC) pipes made out of HDPE for mechanical protection to underground power/communication/ OFC / Signal cable conforming to IS 14930 Part - II
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same incase of recessed conduit as required.50 mm
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Fabricating, supplying, conveying, lifting, and erecting tubular post of overall height 11.70 m using 150mm and 125mm of Heavy-duty G.I. Pipe sections having ISI mark and of approved quality(TATA, ZENITH, APOLLO) as per the drawing erected on a RCC footing, using 1:2:4 CC with nominal reinforcement and 6 Nos. of PCC well steining having 0.9m dia and 0.30m height with a muffing of 0.6mx0.6mx1m and 8 numbers of 20mm dia 2.50m long MS foundation bolts having 150mm long standard thread on both ends and 3Nos 20mm and 2Nos 20mm nuts at the top and bottom for each bolt. The post is to be provided with a 20mm thick MS flange of OD 300mm with 8 nos of 20mm bolt holes and a base plate of 600mm square 10mm thick with 8 Nos 20mm dia bolt holes embedded in the concrete 1.8m below ground level. The post should have a 1500mm dia ring made out of 50mm heavy GI pipe with cross supports using 40mm heavy GI pipe at the top for mounting the luminaries and its control gears. A 10mm thick MS flange having OD 300mm at 1200mm below the first ring mounted to the post. The top of the pipe should be sealed with 125mm table F Dummy flange. 12mm dia wire rope is to be provided for the entire length of the post as a mechanical support for the cables to the luminaries. Inverted Y arrangement using 50mm heavy GI pipe, flange, and dummy flange cover, and 75mm 4kgf/cm2 PVC pipe with a bend to be provided in the concrete muffing for taking out cables. 8 x 75mm stainless steel Bolt & Nut shall be used for fixing all the flange covers. The post is to be painted with two coats of UVresistant polyurethane paint of approved quality and color over two coats of best quality industrial epoxy primer and epoxy paint. All MS materials used for fabrication shall be dip galvanized.
Supply, installation, testing and commissioning of 16m retractable high mast lighting system fabricated with mild steel plate conforming to BS EN10025 Grade S 355/IS 2062and >85 microns thick hot dip galvanised as per BSEN ISO 1461/IS 2629 continuosly tapered and 20 side polygon shaped folded sections having only one longitudinal weld and telescopic slip joints shall have an overlap not less than 1.5 times the diameter at the joint.The mast shall have an opening of 300x1000mm size with door and necessary reinforcements at the edges with vandal resistant locking arrangementsThe mast shall withstand wind speeds upto 200 km/hr and maximum gust speeds of 3 seconds duration and shall be erected on RCC footing as per the site condition and design should conform to ILE TR No.7 and IS 875 part 3.. The 1200mm dia. Circular retractable lantern carriage in two halves joined by bolted flanges and lantern fixing arms and plates shall be suspended marine grade stainless steel wire ropes conforming to AISI 316 on non-corroding type pulleys with self lubricating bearings on stainless steel spindles for accommodating wire ropes and electrical cables with required load carrying capacity and shall have motorised lowering and hoisting arrangements with two winch drums with tested capacity and individual drum operationof each drum. The manual/power tool operated winch drive system shall have 3 phase 415VAc single speed electric motor of required power rating coupled with a self lubricating reduction gear box with bronze/LN 19 gears and SAE 140 Gear oil.m The electrical multi core cable shall be EPR insulated PCP sheathed and cotton braided with flexible copper conductor. Local isolation facility is to be provided at the base of the mast employing MCBs and supply and installing a separate weather proof MS cubicle for housing electrical switch gears, 3 Nos.phase indication lamps, termination of the incoming four core cables upto 25sq.mm conductor size, 32A TPN Switch Disconnector Fuse, 3 phase distribution board conforming to IP 54 with 4 pole 25A 30mA RCCB and MCBs for controlling luminaires.The mast shall be provided with lightning protection,lightning finial and LED type aviation obstruction lights mounted on the top with required earth electrodes as IS3043 & IS 2309.Supply and installing the following on the mast:-Supply of 300WLED floodlight with60 degree beam angle Wipro/Havells- 6 nos and Supply of 400W LED Flood lights with 30 degree beam angle of Wipro/Havells - 2Nos .(Luminaire housing components to be extruded alumnium with high performance heat shrinks, heat resistant toughened glass, extruded with aluminium control gear compartment, LED make CREE LED/equivalent, colour temp-5700K +/- 300K,. LEDs are provided with secondary lens optics to get optimum optical performance.) -- 8 Nos.
Supply and fixing cubicle type dust and vermin proof 300x600x170 mm, (Mi 0400) Hensel make thermoplastic IP 65 junction box with lid including supplying and fixing 2 Nos Hensel make 10 sq. mm 5pole terminal set for phases and neutral in the existing masonry cubicle fixing the following items, including giving connection using 4.0 sqmm, PVC insulated copper wire , drilling necessary holes for termination as well as entry and exit of cable, terminating the earth wire in the earth strip etc complete. All the bolt nut & washer shall be brass
Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.
Supplying 200W,23500 Lumens floodlight luminaire suitable for high mast lighting with single piece die cast aluminum housing with inbuilt potted driver & 10KV inside surge protection device for luminaire, IP66 optical tightness, IP67 driver tightness, IK 10 Impact resistance having operating voltage range 120-277 V, luminaire efficacy >= 110lumen/watt, color temperature 5700 K color rendering index >75, electrical class- I, Lumen maintenance L70@60,000 hrs etc complete . Preferred make: PHILIPS or equivalent
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
Fabricating and supplying special clamping arrangement for fixing an asymmetrical beam integral LED flood light on 50 mm dia GI pipe ring with two clamps each made out of 50 x 6mm MS flat and 8x40mm SS nuts and bolts for one luminaire. The clamps are to be linked with 40x6mm MS flat with suitable holes 8mm,10mm, or 12mm size with suitable size SS Bolt& Nut to fix the luminaire. All the items are to be painted with two coats of epoxy-based industrial primer of approved quality and two coats of epoxy paint of approved color as per drawing
Supplying and making end termination nickel plated single compression brass cable gland for 2 core 2.5 sq mm PVC insulated and PVC sheathed armored copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket
Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
Supply and fixing Cable Junction Boxes IP 67for outdoor applications (with knockouts for cable entry - Black Colour) suitable for cable sizes 2.5 sq. mm,93 X 93X 62 mm Hensel model No KF 0202 B or equivalent and accessories for Cable Junction Boxes such as Copper Terminal Set 2.5 sq. mm 5 Pole 1 No, Support for Terminal 1No including fixing the accessories using suitable size Stainless steel Bolt and nut, giving necessary connections, making good the damages, etc. as required.
Conveyance, installation, testing, and commissioning of departmentally supplied floodlight luminaire with a lamp on the existing tubular post of height up to 15m from ground level. All bolts and nuts shall be Stainless steel.
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 4.75 mm copper conductor (6SWG)
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe asrequired.4 core 25 sq mm
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 35 sq mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
Supply and fixing IP 65 HENSEL 1 row 9 module( Model No KV 7109) KV thermoplastic circuit breaker boxes with PE + N Terminals on the surface using suitable size stainless steel screws.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
Supplying and fixing of surface/ recess mounting, vertical type, 415 volts,Dust and waterproof ,IP66 Hensel make or equivalent FPVN 0402 Transparent door (8 + 12 way) VTPN poly carbonate distribution board , with provision for MCCB as incomer, interconnection between incomer Isolator and bus bars of inclusive of 125 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's painted, inclusive of , tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.
Supply, conveyance and fixing 25 - 40 A, 25 kA (Ics=100%Icu), 3 pole, MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL & SC conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required
Supply of superior quality copper earth socket for the 3.15mm (10 SWG) earth conductor including crimping etc. as required.
Supply of superior quality copper earth socket for the 6 SWG earth conductor including crimping etc. as required.
Supply, installation testing and Commissioning of 4 x 65w Stand alone Solar Floodlight Minimast System with 24 hours backup with dimming option. Dimmable Floodlight Luminares with 65W and 10500 Lumens System output with a system efficacy greater than 160 Lumen per watts, IP66 & IK08 Protection, single piece Pressure die cast aluminum housing with ADC12 grade and individual lens mounted on led's by injection molding in PC Cover. The shall be having anti corrosive coating with 1000 hours salt spray tested and L70 at 75000 Hrs - 4 nos, The Charge controller using in the system shall be MPPT type Hybrid Programmable and Dimmable with > 93% efficiency, IP67 Connectors- 4nos, Solar Panel of 250Wp 36V Mono- Crystalline with excellent aging resistance and UV endurance to withstand harsh environment, environmentally sealed to IP67 -4 nos, The Batteries using in the system shall be Lithium Ferro Phosphate type with 60Ah 25.6V Maintenance free having minimum 2000 cycles life - 4 nos, And installing the system on 8 meters hot dip galvanized Octagonal Pole with top 70mm and bottom 175mm dia made of 3mm sheet thickness, base plate shall be not less than 275 x276x16mm, Mounting Brackets for holding Solar panels and Battery at top and Second ring bracket for fixing floodlights with all accessories. Excavation and foundation casting using M25 grade concrete in 500x500mm and 1000mm under soil and 20 cm above ground level along with required reinforcement as per site condition. Concrete/Rock by Chemical anchoring of threaded bolts with min 10cm inside concrete by vertical drilling and fixing using the chemical as required.Cleaning of solar panels must be done atleast once in every month durig DLP period
Engaging labourers for clearing the site for mast foundation including removing rocks, jungles, etc if any as per the direction of the departmental officers at the site - Beldar
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
SAFIYULLA K V
MOHANAN T
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_881803.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .