Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.7 LAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC Being lowest. | |
| 2 | L2₹48.9 L+₹4.9 L (11.1%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹49.6 L+₹5.7 L (12.9%)Rejected-Finance 131 SANGAM NAGAR OPP NATIONAL SCHOOL SANGHVI PUNE 411027 | PUNE | MAHARASHTRA | 411027 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | Rejected-Technical DOOR NO 3 79 CHENNNADGRAMAPANCHAYAT PERUMBALA KASARAGOD 681317 | PERUMBALA | KASARAGOD | KERALA | 681317 | - | Rejected-Technical Not enlisted in eligible category | |
| 5 | Rejected-Technical 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | - | Rejected-Technical Not enlisted in eligible category |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
3 Jan 2023, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2022_MES_565767_1
GE MAINT EZHIMALA 8527
Open Tender
Civil Works
Item Rate
330 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹88,000
Yes
28 Feb 2023
28 Nov 2022
5 Jan 2023
28 Nov 2022
3 Jan 2023
29 Dec 2022
29 Nov 2022 - 5 Dec 2022
Amount
NOTES FOR ALL ITEMS OF BOQ:- 1.Contractor should visit the installation before quoting the tender to know the working condition of the station. 2. Maintenance / Servicing work must be get it done through OEM or its authorized service provider/centre and completed through OEM rep only. 3. Safety certificate for steam pipe line should be provided by the contractor on monthly servicing and he will be responsible for any loss. 4. Contractor has to provide all type of tools required for repair/replacement of the laundry items. It shall be deemed to be included in the quoted rate. 5. All requisite safety measures to be adopted at site during servicing & repair of equipment. 6. Please refer PS Clause 16.1 for penal recovery for not attending complaints and rectifying defects. 7. Attending breakdown call & nececessary servicings shall be deemed to be included under the unit rate quoted for below Items. Notes for item Ser No 02 to 08:- The servicing/repair/replacement work will be executed by Ramson /IFB (OEM) only and before placing the work order, contractor has to provide MoU (Memorandum of understanding) from Ramson/IFB. The contractor will be responsible for submmiting a copy of MoU to GE(M) Ezhimala before placing the work order.
COMPREHENSIVE MAINTENANCE TO HOSPITAL LAUNDRY EQUIPMENTS M&L for comprehensive maintenance including routine, preventive and breakdown maintenance, repairs and servicing of following equipments for smooth functioning including cleaning, oiling, greasing checking of complete system for trouble free functionability, replacing worn out nuts, bolts, V-belts etc as required all as specified and directed by Engineer -in -charge. Make : Ramson/IFB/Bucato. (a) Washer Extractor RVW30 -2Nos (b) Tumbler dryer RTD 25- 2 Nos (c) Calendering Machine RFWI 1600x400-1 No. (d) Compressor STD - 01 Nos. (e) Calendering Machine RFWI 2000x400- 1 No. (f) Complete Steem system for laundry. (g) Vaccum Ironing table RV 130X 80- 1 Nos. (h) Electrical boiler MR 12 - 2 Nos. (i) Utility Press STD - 2 Nos. (j) Stain Removing machine CL 7 - 1No.
COMPREHENSIVE MAINTENANCE TO STATION LAUNDRY EQUIPMENT M&L for comprehensive maintenance including routine, preventive and breakdown maintenance, repairs and servicing of following equipments for smooth functioning including cleaning, oiling, greasing checking of complete system for trouble free functionability, replacing worn out nuts, bolts, V-belts etc as required all as specified and directed by Engineer -in -charge. Make : Ramson/IFB/Bucato. (a) Washer Extractor RVW45- 4Nos (b) Tumble dryer RTD 50 kg- 04 Nos (c) Calendering Machine RFWI 2000x400- 1 No. (d) Vaccum Ironing table RV 130X 80- 6 Nos. (e) Electrical boiler MR 18 - 2 Nos. (f) Utility Press STD - 2 Nos. (g) Stain Removing machine CL 7 - 1No. (h) Complete Steem pipe line (i) Compressor STD - 01 Nos.
COMPREHENSIVE MAINTENANCE TO NEW INDUSTRIAL LAUNDRY EQUIPMENT M&L for comprehensive maintenance which include routine, preventive and breakdown maintenance including repairs and servicing of following equipments for smooth functioning including cleaning, oiling, greasing checking of complete system for trouble free fuctionability, replacing worn out nuts,bolts,V-belts etc as required all as specified and directed by Engineer -in -charge. Make : Ramson/IFB/Bucato. (a) Tumble drier 120Kg,Model:RTD 120 Make:LHP-2Nos (b) Washer Extractor 120Kg,Model:RVWE 120 - 2Nos (c) Legger Laundry Press, Air Pressure 6-7, Steam inlet1/2" steam outlet1 /2",vaccum size 4", vaccum motor 0.75HP, Air inlet size 8mm, weight 460kgs, Make: Ramson-2 Nos. (d) Vaccum Ironing table,Make: Ramson 2128 Iron or equivalent in Stefab/Fabcure/Lucky Engg - 8 Nos. (e) Compressor 5HP, Make : Ramsons - 1 Nos
COMPREHENSIVE MAINTENANCE TO OLD INDUSTRIAL LAUNDRY EQUIPMENT M&L for comprehensive maintenance which include routine, preventive and breakdown maintenance including repairs and servicing of following equipments for smooth functioning including cleaning, oiling, greasing checking of complete system for trouble free fuctionability, replacing worn out nuts,bolts,V-belts etc as required all as specified and directed by Engineer -in -charge. Make : Ramson/IFB/Bucato. (a) Industrial Tumble drier 60Kg - 3Nos (b) Washer Extractor 60Kg - 3Nos (c) Legger Laundry Press, Air Pressure 6-7, Steam inlet1/2" steam outlet1 /2",vaccum size 4", vaccum motor 0.75HP, Air inlet size 8mm, weight 460kgs, Make: Ramson-2 Nos. (d) Vaccum Ironing table,Make: Ramson 2128 Iron or equivalent in Stefab/Fabcure/Lucky Engg - 12 Nos. (e) Air Compressor - 1 Nos. (f) Water Softner - 01 No. (g) Body Press - 02 Nos. (h) Flat bed press - 03 Nos. (j) Flat work corner - 01 No. (k) Dry Cleaning Machine - 01 No. (l) Vacuum Ironing table - 12 Nos. (m) Legger laundry Press - 02 Nos. (n) Complete steam pipe line system.
Comprehensive maintenance and servicing of industrial tumbler drier & associated system of 25 Kg capacity installed at squadrons A,B,C,D,E (Total Qty -05 Nos) including control panel all connected items and carrying out routine check of the machine oiling, greasing and replacement of all the worn out defective minor parts with new parts as per requirement for smooth functioning of plant complete all as specified and directed by Engr-in-charge. Make : Ramson/IFB/Bucato. Note:- Replacment of minor parts shall be deemed to be included under the unit rate quoted.
Comprehensive maintenance and servicing of boiler installed at old laundry for cadets of IBR 2x400 kg/hour capacity of mechanical laundry including control panel, all connected items and carrying out routine check of the machine oiling, greasing, replacement of all the worn out defective minor parts, greasing for smooth functioning complete all as specified and directed by Engr-in-charge. Note:- Replacment of minor parts shall be deemed to be included under the unit rate quoted.
Comprehensive maintenance and servicing of boiler installed at new laundry of 2x600 kg/hour capacity of mechanical laundry including control panel, all connected items and carrying out routine check of the machine oiling, greasing replacement of all the worn out defective minor parts greasing for smooth functioning complete all as specified and directed by Engr-in-charge. Note:- Replacment of minor parts shall be deemed to be included under the unit rate quoted.
Notes for Ser item No 2.00 to 8.00 :- 1.Consumables and replacement of minor parts shall be deemed to be included under the unit rate quoted. 2. Major spare parts catered under item No.10.01 to 11.08 will be measured and paid separately under relevent items of BOQ as supply and fix, shall be carried out through OEM rep only.
Supply and fixing following spare parts requried for laundry equipments:-
Control Module for washer extractor
Limit Switch for washer extractor
Heavy duty door latch for washer extractor
Finned Heater for tumble dryer
Contactor 50A for washer extractor
Big Hooter tumble dryer
Bearing UCFL 205 for tumble dryer
SS Flexible Hose for tumble dryer
Spring RTD 30 for tumble dryer
Instrument Transformer 52 V,415 V for calendering machine
Table float switch
Steamer Hose with Nozzle for electric boiler
Steam air gun for electric boiler
Pressure switch for electric boiler
Cold Spotting Chemical Gun
Pump ST 120 for compressor
Photo cell STK 20K for utility press
Pressure guage for steam removing machine
Nozzle 1 GP for compressor
Controller STG 500 PLC washer extractor
Iron Box
1/4" Solenoid Valve
130/80 Table cloth with connected items like spunj and spring complete as per existing and complete painting of ironing table with suitable paint as directed
9A Contactor
BLIR Timer 3548(Grm64E)
1" Solenoid Valve
Iron Element 2128
2128 Regulator
Iron Box silicon pad
PLC Probe
415-220 Transformer
6A Wire Connector
16A Wire Connector
12A Contactor
Washer Extractor belt
FPR O2 Timer
Temperature Controller With Probe
Indicatior Lamp (Red & Green)
Start & Stop Button
ON & OFF Switch
RTD Door Handle (Door Lock)
27" Fin Heater
Door Limit Switch
Emergency Stop Button
Door Gasket
IO Card
Transformer 12-01-12
3 Way Solenoid Valve
2 Way Solenoid Valve
5/2 Solenoid Valve
1/2" SS Solenoid Valve
9 KW Heater
Flat Heater
PU4 Hose
PU6 Hose
PU8 Hose
Drain Bush
Air Filter Set
Stainer
Softner Multiport Valve any size
3" Electrical Drain Valve
RVWE control Transformer 2.5 A
Gland washer HTN8
Photoresister QRB 1 (Long)
Electrode Cap
Valve Seat Assembly
Metalic Braded Hose 1/2x20"
4" Silicon Hose Pipe
Rocker Switch 6 Amps
Inline Duct Fan
Water Extractor PLC system - GWE001
Solenoid valve 1/4 - T
Thermostat 2128
Teflone wire 1.5 sqmm
Cable 2128, 4 core
Burner(SEQ) CONT-SIE (L&S)-LMO24.111C2,230v With Base (P42BC10160)
Gland Washer (PO1RDS0690)
Heat Optimiser (PRXEC10014)
Limit Switch-10A,500V,1NO+1NC (P41ZS10010)
Nozzle-Danfoss-7.5 GPH,D45,S'PAT-B (P22ND10080)
Photo Cell-SIE (L&S)-QRB 1A (A070B70A)With Accessories -Large (P22BE10050)
PID Control-SELEC-TC-513AX-NS207-(I/P-RTD/TC +1c/O C.RLY, 1SP) (48X48) (P42G190180)
PR Gauge BRDN-WPC/PB-0-25 KG, D100,3/8 BSPT, PCB (P41PG10160)
Solenoid Coil For Burner ROD110V/50Hz
SP-Filter-Element.10 MESH,1/2", PNO-P260110070 (P26019 027 0)
SP-Filter Gasket For Filter Cover (P260190260)
Temp.Emnt (RTD)-PT100,SIMPLEX-3/8" BSP,D6 X LG 100, ADJ With Cable 2.5M(P44TE10080)
Gripper Belt
Rapid relief valve
STK 200 Data cable
SSJ valve 1/2"
Micro switch 2128
1/2" steam Trap
MY relay 220V
Inverter Cooling Fan
SMPS 1 Amps (RS-25-24)
Foot Switch
63 Amps MCB 4 Pole
Push button with element rod
Bearing 32213
Bearing 32218
Fuel pump for boiler
UKP317 Bearing
UKP317 Bearing Sleeves
15 HP Inverter
1 HP Monoblock pump set Model KDS-90
1HP/.75 HP 3 phase Induction Motor suitable for Ironing Table
LED Tube light fitting with proper fixing arrangement of length 4" for Ironing Table
M&L for painting of boiler chimney ( up to any height self supported) and cat ladder, cleaning inside surface & out side surface and paiting complete outer surface with Heat resistant Aluminium paint (600* C) including welding work if required, repairing of air blower cleaning and painting etc with all connecting materials complete all specified and as directed.
Supply & fix electrical boiler suitable for two ironing table capacity of Model No MR 06 of make Ramsons Laundry ( IFB) complete all as specified and directed by Engr-in-Charge.
Supply & fix steam line using 15 mm dia SS 304 pipe including covering with asbsetos rope, aluminium clading with insulation foam and steam line with all spares/fittings required at site for fixing of pipe like suitable flange, collar heavy , ball valve, pipe nipple, teflon tape, non metallic ring gasket, long bend, tee, MS long bend heavy complete all as specified and directed by Engr-in-Charge.
Supply & fix steam line using 25 mm dia SS 304 pipe including covering with asbsetos rope, aluminium clading with insulation foam and steam line with all spares/fittings required at site for fixing of pipe like suitable flange, collar heavy , ball valve, pipe nipple, teflon tape, non metallic ring gasket, long bend, tee, MS long bend heavy complete all as specified and directed by Engr-in-Charge.
Supply & fix steam line using 40 mm dia SS 304 pipe including covering with asbsetos rope, aluminium clading with insulation foam and steam line with all spares/fittings required at site for fixing of pipe like suitable flange, collar heavy , ball valve, pipe nipple, teflon tape, non metallic ring gasket, long bend, tee, MS long bend heavy complete all as specified and directed by Engr-in-Charge.
shakti engineering and electrical works
Leo Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .