Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹2 Cr
EMD Value
₹10 L
Closing Date
16 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Medial Superintendent,
PROVIDING SURGICAL ITEMS P.D.U. Hospital, Rajkot. (Part- 14 of 16) Misc.
267707
2026-2028
Open
Miscellaneous Works
Supply
Rajkot
4 documents required · 2 mandatory · 2 optional
₹15,000
Medical Superintendent, P.D.U. Hospital, Rajkot ( Tender fee common for Part - 1 to 16 )
₹10 L
23 Jan 2026
23 Jan 2026
23 Jan 2026
16 Feb 2026
23 Jan 2026
Measurements to be taken
All sizes
All sizes
23CMX100CM
54CMX45CM
23cmx30cm
9CMX25CM
9CMX35CM
9CMX15CM
9CMX30CM
10cmx10cm
15CMX15CM
20CMX30CM
Description
Intracranial Pressure Monitoring System Transducer cable
Stand alone Monitor should display mean Systolic and Diastolic Intra cranial Pressure as Digital Display; the display should be as Digital Data rather than through Hydrostatic Column or Fibreoptics with one touch zero function for disposable transducers; it has user friendly setings for Alarm Function with battery back-up facility for 2-3 hours. should be used for both Adult and Paediatric CSF pressure monitoring
The catheter should be inbuilt with micro sensor and ventricular catheter for the drainage of the CSF and monitor ICP at the same time., It should have 38cm clear ventricular catheter with preloaded stylet., The transducer should consists of a miniature strain gauge pressure sensor mounted in a titanium case at the tip of a 100cm flexiblenylon tube., It should come with 7-guage tunneling trocar for placement., The information should be relayed electronically rather than hydrostatic or fiberoptics., It should be made of strain gauge mechanism, It should have high fidelity of greater than 10000Hz to facilitate excellent wave form analysis., The drift in ICP over 9 days period should be maximum of 1mmhg or less., The system should be capable of monitoring Parenchymal ICP., The drift in ICP over 9 days period should be maximum of 1mmhg or less., The system should be capable of monitoring Subdural ICP.
The catheter should be inbuilt with micro sensor and ventricular catheter for the drainage of the CSF and monitor ICP at the same time., It should have 38cm clear ventricular catheter with preloaded stylet., The transducer should consists of a miniature strain gauge pressure sensor mounted in a titanium case at the tip of a 100cm flexiblenylon tube., It should come with 7-guage tunneling trocar for placement., The information should be relayed electronically rather than hydrostatic or fiberoptics., It should be made of strain gauge mechanism, It should have high fidelity of greater than 10000Hz to facilitate excellent wave form analysis., The drift in ICP over 9 days period should be maximum of 1mmhg or less., The system should be capable of monitoring Parenchymal ICP., The drift in ICP over 9 days period should be maximum of 1mmhg or less., The system should be capable of monitoring Subdural ICP. It should be available with Scull bolt to reduce the movement of implanted sensor
The catheter should be inbuilt with micro sensor and ventricular catheter for the drainage of the CSF and monitor ICP at the same time., It should have 38cm clear ventricular catheter with preloaded stylet., The transducer should consists of a miniature strain gauge pressure sensor mounted in a titanium case at the tip of a 100cm flexible nylon tube., It should come with 7-guage tunneling trocar for placement., The information should be relayed electronically rather than hydrostatic or fiberoptics., It should be made of strain gauge mechanism, It should have high fidelity of greater than 10000Hz to facilitate excellent wave form analysis.
The catheter should be inbuilt with micro sensor and ventricular catheter for the drainage of the CSF and monitor ICP at the same time., It should have 38cm clear ventricular catheter with preloaded stylet., The transducer should consists of a miniature strain gauge pressure sensor mounted in a titanium case at the tip of a 100cm flexible nylon tube., It should come with 7-guage tunneling trocar for placement., The information should be relayed electronically rather than hydrostatic or fiberoptics., It should be made of strain gauge mechanism, It should have high fidelity of greater than 10000Hz to facilitate excellent wave form analysis. It should be available with Scull bolt to reduce the movement of implanted sensor
The catheter should be inbuilt with micro sensor and ventricular catheter for the drainage of the CSF and monitor ICP at the same time., It should have 38cm clear ventricular catheter with preloaded stylet., The transducer should consists of a miniature strain gauge pressure sensor mounted in a titanium case at the tip of a 100cm flexible nylon tube., It should come with 7-guage tunneling trocar for placement., The information should be relayed electronically rather than hydrostatic or fiberoptics., It should be made of strain gauge mechanism, It should have high fidelity of greater than 10000Hz to facilitate excellent wave form analysis., The drift in ICP over 9 days period should be maximum of 1mmhg or less., The system should be capable of monitoring Ventricular ICP.
The catheter should be inbuilt with micro sensor and ventricular catheter for the drainage of the CSF and monitor ICP at the same time., It should have 38cm clear ventricular catheter with preloaded stylet., The transducer should consists of a miniature strain gauge pressure sensor mounted in a titanium case at the tip of a 100cm flexible nylon tube., It should come with 7-guage tunneling trocar for placement., The information should be relayed electronically rather than hydrostatic or fiberoptics., It should be made of strain gauge mechanism, It should have high fidelity of greater than 10000Hz to facilitate excellent wave form analysis., The drift in ICP over 9 days period should be maximum of 1mmhg or less., The system should be capable of monitoring Ventricular ICP. It should be available with Scull bolt to reduce the movement of implanted sensor.
Stand alone Monitor should display mean Systolic and Diastolic Intra cranial Pressure as Digital Display; the display should be as Digital Data rather than through Hydrostatic Column or Fibreoptics with one touch zero function for disposable transducers; it has user friendly setings for Alarm Function with battery back-up facility for 2-3 hours. should be used for both Adult and Paediatric CSF pressure monitoring
As per colomn No.2
As per colomn No.2
Bipolar forceps specially designed for isocool golden tips which is designed for critical surgery procedures which requires critical and precise temperature control to reduce sticking and charring for Minimum peripheral tissue damage with Active Heat Transfer technology where the heat dispersed beyond tips of the forceps
Bipolar forceps Tip specially designed for critical surgery procedures which requires precise temperature control to reduce stickng and charring for Minimum peripheral tissue damage with Active Heat Transfer technology where the heat dispersed beyond tips of the forceps
Bipolar forceps Tip specially designed for critical surgery procedures which requires precise temperature control to reduce stickng and charring for Minimum peripheral tissue damage with Active Heat Transfer technology where the heat dispersed beyond tips of the forceps
Bipolar forceps Tip specially designed for critical surgery procedures which requires precise temperature control to reduce stickng and charring for Minimum peripheral tissue damage with Active Heat Transfer technology where the heat dispersed beyond tips of the forceps
Bipolar forceps Tip specially designed for critical surgery procedures which requires precise temperature control to reduce stickng and charring for Minimum peripheral tissue damage with Active Heat Transfer technology where the heat dispersed beyond tips of the forceps
Bipolar forceps Tip specially designed for critical surgery procedures which requires precise temperature control to reduce stickng and charring for Minimum peripheral tissue damage with Active Heat Transfer technology where the heat dispersed beyond tips of the forceps
Bipolar forceps Tip specially designed for critical surgery procedures which requires precise temperature control to reduce stickng and charring for Minimum peripheral tissue damage with Active Heat Transfer technology where the heat dispersed beyond tips of the forceps
Bipolar forceps handle specially designed for critical surgery procedures which are designed for precise temperature control to reduce sticking and charring for Minimum peripheral tissue damage; should be use with ISO Cool bipolar golden tips
Pediatric glove
Measurements to be taken
Description
50 sheets(maxilla)per pack
2.5percentage w/v chlorhexidine gluconate solution IP 0.5percentage w/v Triclosan USP 50percentage v/v Isopropyl alcohol IP 25percentage v/v N-propanol BP skin emolients
All sizes
adult, child, infant
All sizes
Description
1percentage v/v Poly (Hexamethylene biguanide) hydrochloride) hyrochloride] (PHMB) Perfume
1percentage v/v Poly (Hexamethylene biguanide) hydrochloride)hyrochloride] (PHMB) Perfume
1percentage v/v Poly (Hexamethylene biguanide) hydrochloride)hyrochloride] (PHMB) Perfume
all sizes
9cm x 12cm
12percentage Enzymes (Combination of proteases, Lipases and Amylases), Non ionic surfactants, reservatives
Description
all size
all size
10cmx10cmx10s tin
10cmx30cmx1s pouch
15cmx20cmx1s pouch
15cmx1mtr.roll
10cmx10cmx1s pouch
10cmx10cmx1s pouch
10cmx10cmx10s tin
10cmx30cmx1s pouch
15cmx20cmx1s pouch
15cmx1mtr.roll
Description
PATCH
PATCH
PATCH
PATCH
PATCH
PATCH
PATCH
PATCH
PATCH
PATCH
10cmx10mtr
10cmx30cm
10cmx15cm
6cmx7cm
10cmx20cm
10cmx25cm
10cmx15cm
10cmx10cm
10CMX10CM
15CMX15CM
Sterile , transperent waterproof,breathable material with absorbent padding
Sterile , transperent waterproof,breathable material with absorbent padding
Sterile , transperent waterproof,breathable material with absorbent padding
Description
Sterile , transperent waterproof,breathable material with absorbent padding
40x40in(102x102cm)
MANUFACTURING PLANT SHOULD HAVE USFDA ApprovAL/ CE CERTIFICATION
Pack of 4
All sizes
The pediatric Illuminated Stylet will fit comfortably into a 4.5 intubation tube, and with lubrication into a 4.0 tube.
Pack of 6 pcs
Pack of 6 pcs
Pack of 6 pcs
All sizes
all sizes
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SURGICAL ITEMS.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .