Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.1 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹49.2 L+₹33,796.16 (0.69%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED | |
| 3 | L3₹50.4 L+₹1.6 L (3.20%)Rejected-Finance 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | L3 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED | |
| 4 | L4₹50.7 L+₹1.9 L (3.89%)Rejected-Finance 114 RAJEEV GANDHI NAGAR KOTA RAJ | KOTA | KOTA | RAJASTHAN | 324005 | L4 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED | |
| 5 | L5₹50.9 L+₹2.1 L (4.21%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
13 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Kota
DADWARA KOTA RAJASTHAN 324002
ADDN/ ALTN TO BLDG NOS T-19, T-20, T-04, OTM/EML/19 AND TA-02 (COOK HOUSE) FOR CERTAIN UNITS AT MIL STN KOTA
2024_MES_668032_1
8865E8
Open Tender
Civil Works
Item Rate
183 days
GE Kota
AS PER TENDER DETAILS
8 documents required · 8 mandatory
₹500
Yes
GE Kota
₹93,000
Yes
26 Oct 2024
25 Jul 2024
20 Sept 2024
25 Jul 2024
13 Sept 2024
8 Aug 2024
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L Glazed ceramic coloured tiles on vertical surfaces 350x 250x7 mm/450X350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including 10 mm thick rendering in CM 1:4 backing, complete all as specified and directed.
Material and labour for plastering 15 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:4 finished even and fair complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 25 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed.
M & L for machine cut Kota stone slab flooring 18 to 20 mm thick over and including cement screed bed of 15 mm thick in cement mortar 1:6, laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for mirror polishing existing kota stone flooring including filling all existing cracks and jointing with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
Taking down existing treatment of any description such as PCC padding, lime concrete, mud phuska etc. and any numbers of layers upto any thickness from roof including scraping and roughening old by picking, sweeping clean and washing down and removing debris outside MD land complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate in roof kerbs or mud stops,padding, rounded or chamfered on edges complete all as specified and as directed.
M & L for brushing neat cement slurry with 3.0 kg of cement per square meter complete all as specified and as directed.
Material & labour for rendering 15 mm thick in cement mortar 1:4 over RCC Roof mixed with water proofing compound @ 3% by weight of cement or manufacturer instruction complete all as specified and as directed. (Note;- water proofing compound shall be measured and paid separately as supply only)
M&L for cleaning of roof slab including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over cold applied bituminous primer conforming to IS 3384 @ of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions, complete all as specified and directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of cold applied bituminous primer conforming to IS:3384 @ 0.40 Kg/Sqm. (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm (minimum) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimney/other vertical surfaces and polymeric membrane inserted in groove and sealed with paving bitumen. (v) Cost of above aspects is deemed to be included in quoted rates.
Supply only liquid water proofing compound complete all as specified and as directed.
Dismantling water tanks capacity exceeding 250 litres but not exceeding 500 Litres and removing to store complete all as specified and as directed.
S & F rotational moulded polyethylene tripple layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed.
S & F ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm size, minimum weight 210 grams complete all as specified and as directed.
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and as directed.
M & L for brick work with fly ash bricks of class designation 7.5 and non-modular size as per IS 12894: 2002, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed.
M & L for brickwork with fly ash bricks of class designation 7.5 and non-modular size as per IS 12894: 2002, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed.
M & L for walling (curved on plan to a mean radius exceeding 6 metre) of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cement mortar (1:6) complete all as specified and as directed.
Extra over stone walling of lime or sand stone for hammer dressing to face stones and dressing of face beds and joints with maximum depression of face from straight edge held against the dressed surface not exceeding 40 mm, of random rubble walling, uncoursed or brought upto course complete all as specified and as directed.
Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water complete all as specified and as directed.
Material and labour for plastering 15 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over 3 mm thick wall care putty to match the surfaces complete all as specified and as directed.
M & L for preparation of newly plastered surface of wall and applying two coats cement base paint over one coat of primer complete all as specified and as directed.
Supply & fix sheet glass, ordinary quality, 3 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658: 2021 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 30 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. complete all as specified and as directed.
Providing and laying at or near ground level factory made kerb stone of size 300 mm X 300 mm X 150 mm, top bullnosed shape, made of M-25 (Design Mix) grade cement concrete, in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed.
M & L for complete removal of existing treatment and preparation of surfaces and applying two coats of cement base paint complete all as specified and as directed.
Complete removal of existing treatment of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over 1 mm thick wall care putty to match the surfaces complete all as specified and as directed.
Preparation of old decorated surfaces on ceilings and applying two coats of white wash complete all as specified and as directed.
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Preparation of old painted steel surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M & L for cutting out cracks to 'V' section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed.
Material and labour for plastering 15 mm thick on other than fair faces of brick wall or stone surfaces in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: Water proofing compound shall be measured and paid for separately.
M & L for rough dressed sand stone slab flooring, 30 mm thick, laid dry but jointed and pointed in cement mortar (1:3) complete all as specified and as directed.
M & L for brick work with fly ash bricks of class designation 7.5 and non-modular size as per IS 12894: 2002, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Dismantling of cast iron or reinforced concrete drain pipes of size 100 mm jointed in cement mortar and taking out of trenches, if required complete all as specified and as directed.
S & F cast iron, centrifugally cast, socket and spigot, nominal dia 100 mm soil, waste and vent pipe as per IS 3989: 2009 in any length with cement joints, laid in trenches or in floors complete all as specified and as directed.
Material and labour for plastering 15 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over 1 mm thick wall care putty to match the surfaces complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of exterior emulsion paint over a coat of primer complete all as specified and directed. Note :- (i) All coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI / Manual application Allow 6-8 hrs to dry the surface in subsequent coats of paint (ii) Make should be dulux weather shield max/Nerolac Excel Everlast 12/Asian paint ultima protek / Berger weather coat long life 15 or Techno commercially equivalent makes specified in PS complite all as specified and directed.
Material and labour for complete removal of existing treatment for preparation of old surface of wall and applying two coats of exterior emulsion paint over a coat of primer complete all as specified and directed.Note :- (i) cracks of wall plaster should be filling upto 5 bars of positive hydrostatic pressure on vertical walls without any dilution with forced coverage not more than 3.5 sqm / ltr as per manufacturer's instructions. (ii) All coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI / Manual application Allow 6-8 hrs to dry the surface in subsequent coats of paint (iii) Make should be dulux weather shield max/Nerolac Excel Everlast 12/Asian paint ultima protek / Berger weather coat long life 15 or Techno commercially equivalent makes specified in PS complite all as specified and directed. (iv) decorated treatment on wall / ceiling / chajja by scrapping with trucare wall sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling cracks, holes etc
Preparation of newly plastered surfaces on walls and applying two coats of white wash complete all as specified and as directed.
Preparation of old decorated surfaces on ceilings and applying one coat of white wash complete all as specified and as directed.
M & L for preparation of old painted wood or wooden surfaces, of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated (profile) steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category C3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering/ wall cladding fixed with self drilling screws and washers as specified including end and side lap, necessary scaffolding and safety measures at any floor complete all as specified and as directed.
M & L for hard core of broken stone/ boulders aggregate, broken to gauge not exceeding 63 mm complete all as specified and as directed.
M&L for joint free non skid matte finish ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for joint free non skid matte finish ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm fixed on vertical surfaces as scarting, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 10 mm thick rendering in CM 1:4 backing, complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc.complete all as specified and as directed.
M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
M & L for 20 mm thick machine cut granite tiles (any type) bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with granite stone shade over and including 20 mm thick screed in cement mortar 1:6 including grinding and polishing complete all as specified and as directed.
M & L for 20 mm thick Granite (of any type) tiles machine cut, in skirting/dado laid over and including 10 mm thick backing in cement mortar 1:4 cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and as directed.
M & L for green marble work 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like including laying over 20 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and as directed.
M & L for powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium section (thickness of powder coating not less than 50 micron) weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150 mm long (1 no.). hinges type B-21 100 mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed.
M & L for powder coated aluminium frame for doors, windows, ventilators (thickness of powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
Supply and fix Aluminium deco grill Cat No DG-104, 10 mm thick ,cut to required size/shape and fixed in position with and including stranded aluminium frame of F section of size 23.04x15.3x1.4mm thick all as per manufacturer instructions complete all as specified and as directed.
Supply & fix sheet glass, ordinary quality, 5.5 mm thick and glazed with oil putty or fixed with beads in square exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S & F exposed type hydraulically regulated door closers, universal closer, bottle type (type A), Designation No. 2, suitable for 36 kg to 60 kg mass of doors & 701 mm to 850 mm width of door, aluminium alloy non porous body and black plate, aluminium alloy piston or pack piston/ pillion, anodized finish not be less than Grade AC 15 of IS 1868 : 1996 with transparent anodic film as per IS 3564: 1995 complete all as specified and as directed.
S & F powder coated, minimum thickness 50 micron, aluminium sections for doors, windows, ventilators, door partition including fabrication of frame, shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement etc. including all accessories such as glazings clips, and rubber beadings for fixing glass panes in frame complete all as specified and as directed. Note : (i) Glass panes, wire mesh & handle will be measured & paid separately . (ii)The quoted rate shall be inclusive of cost of rubber beading however it will be not be weighed and not paid separately. (iii) All other minor details including cost of locking arrangement shall be included in the quoted rate.
M & L for 6 mm thick aluminium composite panel coloured with decorative choice fixed to aluminium frame work as in door/ partitions complete all as specified and as directed.
Dismantling of wall/ ceiling boards(fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness including cover fillets of any description including all snap grids and hanging arrangements complete all as specified and as directed.
Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605 mm x 605 mm in true horizontal level, hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24 mm X 38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross “T” of size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm centre to centre to form a grid of 1200 mm x 600 mm and secondary cross “T” of length 600 mm and size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200 mm X 600 mm panel to form grids of 600 mm X 600 mm and wall angle of size 24 mm X 24 mm X 0.4 mm. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 mm X 37 mm X 25 mm X 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 mm X 30 mm X 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications and as directed by Engineer-in-charge.
S & F PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification complete all as specified and directed.
Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
M & L for 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates, laid in alternate panel, finished surface even and fair including filling in position with 85/25 industrial grade bitumen mix filler of proportion 80 kg of hot bitumen, 1 kg of cement and 0.25 cubic metre of coarse sand as in plinth protection complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and as directed.
S & F 110mm dia PVC(SWR) single socketed soil waste pipes in any length with rubber ring joints ficed to wall with necessary fixing arrangement such as clamps, nuts bolts etc and making good the disturbed surface complete all as specified and as directed.
S & F PVC (SWR) bends of any radius of 110 mm dia complete all as specified and as directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed.
M & L for formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M & L for RCC M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate as in chajjas complete all as specified and as directed.
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed.
Taking down wooden door shutter area exceeding 1.00 but not exceeding 2.00 sqm each complete all as specified and as directed.
S & F 35 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, panelled shutters (one panel) with lock rail and panel of 12 mm thick veneered particle board, Grade -I, Type -I (solid core, general purpose), designation (SO GP-I) conforming to IS 3097 supplied and fixed to chowkhats. The size of style and rail as per IS 1003 (Part I) kiln seasoned and chemically pressure treated.
M & L for 35 mm thick Iind class hard wood, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, wire gauze, etc. (without sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I section 8 Clause 8.24 (b) complete all as specified and as directed.
S & F in repairs 25 mm dia decorative powder coated aluminium curtain rods with decorative ball type side brackets complete all as specified and as directed.
S & F in repairs hexagonal wire netting, size of aperture 25 mm, dia of galvanised steel wire 1.40 mm as per IS 3150: 1982 fixed with tinned tacks of wire staples complete all as specified and as directed.
S & F in repairs sinks with drainage board made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers and 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipes overall size 915 mm X 460 mm bowel size 410 mm X 330 mm X 160 mm complete all as specified and as directed.
S & F Kitchen stainless steel plate rack of size 30" X 36" X 10" awith partition for small/ large plates fabricated out of 24 gauge stainless steel sheet including necessary fixing / fittings & making good the existing surfaces complete all as specified and as directed.
S & F in renewal of Bib taps 15mm dia, chromium plated, long body, with CP flange all as per fixed in repairs complete all as specified and as directed. Make :- CERA cat part No G 1017152 /Jaquar cat pat no VGP-81037/ Hindware cat part No F 740011 or techno commercially equivalent makes specified in PS.
Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.
Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Fixing only to walls and ceilings or laid in floors 15 mm nominal bore, any grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.
Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Fixing only to walls and ceilings or laid in floors 20 mm nominal bore, any grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
S & F pillar taps, 15mm dia, long body/swan neck, fancy type suitable for fixing to wash basin screwed for iron pipe and fixed with necessary fittings and including PVC connection complete all as specified and as directed. Make :- CERA Cat Part No F1003103 / Jaquar cat Part No COP -021PM/ Hindware Cat Part No F 740002 or techno commercially equivalent makes specified in PS.
M & L in renewal of vitreous china wash basin white flat back size 580x430 mm excluding taps but including 32 mm dia CP waste fitting and PVC waste pipe 610 mm long and brackets complete all as specified and directed. Make :- CERA (Cat Part No S 2040109)/JAQUAR (Cat Part No OPs WHT-1580l)/ Johnson (Cat Part No J8396 CH) or techno commercially equivalent Makes as specified in PS.
S & F in repairs vitreous china squatting pan, 'Orissa" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S' trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed.
S & F in repairs PVC low/high level flushing cistern white 10 liters capacity including PVC inlet pipe with brass check nuts low level full both sides along with PVC flush pipe 32 mm dia jointed to WC and handle including brackets fixed in repairs complete all as specified and as directed. Note:- Rate includes removing existing flushing system of CI or any other quality including brackets.
M & L in repairs for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed.
S & F in renewal of Soap dish any type, fixed to plugs with chromium plated brass screws omplete all as specified and as directed. Make :- CERA Cat Part No F5013106CH/ Jaquar cat part No AKP 35731P/ Hindware cat part No F 450022 or equivalent makes as specified in PS.
S & F in repairs PVC cabinet of size 61 cm X 41 cm X 10 cm with 4 mm thick front mirror of size 60 cm X 40 cm & self inside etc. complete all as specified and as directed.
S & F rotational moulded polyethylene tripple layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 750 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed.
S & F in repairs 20 mm nominal size, screw down stop valves, cast copper alloy body and body components with crutch handle, bright finished complete all as specified and as directed.
S & F in repairs 15 mm nominal size, screw down stop valves, cast copper alloy body and body components with crutch handle, bright finished complete all as specified and as directed.
S&F snake guard (door seal Aluminium plate with rubber beading) for door of approved size and shape etc complete all as specified and directed .
M & L for Rim latch with two levers, of brass body, polished bright finish, with brass knob or lever handle and fixed complete all as specified and directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, dia of bolt 12 mm, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F cast aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F butt hinges, extruded aluminium alloy with galvanised mild steel wire pin, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, hinge designation 100B21 as per IS 205: 1992 complete all as specified and as directed.
S & F mild steel sliding door bolts, type I (plate type), size 300 mm, stove enamelled black finish to back plate, straps and staple, electroplated finish with nickel and chromium to hasp and bolt, bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed.
S & F in repairs mild steel door spring of rat tail type of size 300 mm, bright finish including roller and roller plate complete all as specified and as directed.
M & L for Providing 15 mm thick plaster of paris (Gypsum anhydrous) on stone patti ceiling surface without grid frmae complete all as specified and directed. Note :- (i) Undulation may be found in stone patti surface hence thickness of POP may be vary, however qouted rates are inclusive for the same and no extra amount admissible on this account. (ii) Corner fillets made by POP are provided in each wall junctions. (iii) One design made by POP at the centre of room provided in each room/verandah qouted rates are inclusive for the same.
Taking down carefully without point wiring by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse)
Taking down main switch/MCB/MCCB/MCB DB/ MCCB DB/ sheet metal enclosure by disconnecting the electric supply including MCB/MCCB/Cut out etc. any type and size complete all as specified and as directed.
Taking down old unserviceable submain wiring 1.5 sqmm or 2.5 sqmm or 4 sqmm or 6 sqmm or 10 sqmm aluminium/copper conductors any number including batten/conduit/ casing capping including removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface to match the existing surface complete all as specified and as directed.
M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one bell/ buzzer point controlled by one push button on the same board with other switches or on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F switch socket combination with (3 pin and 3 pin) having two earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F call bell suitable for single phase, AC, 240 volts complete all as specified and as directed.
S & F bell push, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F 3 pin socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed.
S & F ceiling roses, 6A, 240 V, terminals for the connection of live, neutral and protective earthing conductors, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed.
Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and as directed. Note - Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of casing/capping shall be measured and paid as one unit length.
S & F LED tube fitting 4 feet 20 watts including tube with high power LEDs as light source and electronic driver complete all as specified and as directed.
S & F LED tube light fitting 2 feet 10 watts including tube with high power LEDs as light source and electronic driver complete all as specified and as directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
S & F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light, CRCA steel sheet housing, CRI greater than 80%, power factor of minimum 0.95, life span of minimum 50000 working hours complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 4 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.Make- Legrand Ekinox3 series/ Schnieder Easy 9 series/ ABB Cat No ISYP021604C0001 or equivalent technocommercially equivalent make as specified in PS.
S & F single door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. Make- Legrand Ekinox3 series/ Schnieder Easy 9 series/ ABB Cat No ISYP011608C0001 or equivalent technocommercially equivalent make as specified in PS.
S & F miniature circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6 A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F miniature circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F miniature circuit breakers (MCB), four pole with three protected pole (TPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage 415 V three phase, rated frequency 50 Hz, Rated current 100 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F exhaust fan, AC, 50 Hz, single phase, 230 V, 300 mm sweep, 4 pole, heavy duty, metal body, 4 Nos blades, Insulation Class A, ISI marked including capacitor to ensure power factor more than 0.9 including louvers and all fixing accessories including making hole for fixing of exhaust fan of suitable size and making good the disturbed surface as per existing complete all as specified and directed.
Supplying, installing, testing & commissioning, Storage Geyser, five star rated, 25 litres Capacity, steel body with stainless steel inner tank material, shock proof, auto cut, on-off indicator, thermoplastic body, corrosion free with safety valve, fusible plug, thermal cut out including fixing by grouting and fastener complete all as specified and as directed.
S & F ceiling fan, AC, 50 Hz, single phase, 230 V, 1200 mm sweep, minimum air delivery 210 m³ per minute, minimum service value 6 m³ per minute per watt, 3 Nos metal blades protected with corrosion resistance paints, with brushless DC motor having electronic controllers that use sensors, ISI marked including capacitor to ensure power factor more than 0.9, five star rating as per Bureau of Energy Efficiency including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
M & L in renewal for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning in renewal of cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling, hand punning down complete all as specified and as directed. Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and as directed.
Supplying & laying in renewal of 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011, laid in trenches complete all as specified and as directed.
Taking down ceiling fan/ exhaust fan, any sweep by unscrewing the U clamp, minor repair including changing capacitor, cleaning the ceiling fan with moist cloth with detergent powder, scrubbing the old paint with sand paper and painting it with super quality synthetic enamel paint of white colour in two coats and rehanging the same after replacing the flexible copper conductor of suitable dia complete all as specified and as directed.
M/S MOHINI ENTERPRISES (BID ID -3088567)
Pioneer Enterprises (BID ID -3088652)
ANNAPURNA ENTERPRISES (BID ID -3088395)
K B Enterprises (BID ID -3085602)
Aditya Enterprises (BID ID -3090085)
M/s Prem Associates (BID ID -3085983)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .