Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 284 CHAND KUTI OPP SHIV TEMPLE RATANADA JODHPUR RAJ | JODHPUR | JODHPUR | RAJASTHAN | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Reject |
| 4 | Rejected-Technical | Rejected-Technical Reject |
Tender Value
Refer Docs
EMD Value
₹34,259
Closing Date
20 Jun 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (E)
All India Institute of Medical Sciences,Jodhpur
Supply, Installation, Testing and Commissioning of Air Conditioners in Yellow Triage area, Emergency dept at AIIMS Jodhpur
2024_AIIMS_811676_1
AIIMS-JDH/EE/ELECT/2024-25/02
Open Tender
Miscellaneous Works
Works
30 days
All India Institute of Medical Sciences
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹34,259
Yes
4 Jul 2024
13 Jun 2024
21 Jun 2024
13 Jun 2024
20 Jun 2024
13 Jun 2024
Amount
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, the condenser fan should reverse the rotation to clean the dust for better efficiency every 60 days, Units including lifting, loading/unloading, and transportation charges, equipped with full / 100% multiple inverter driven highly efficient having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules with min. Five years Warranty on Compressors, microprocessor-based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. Precoated aluminum fin type heat exchanger, low noise, condenser fans, GI coated condenser stands, microprocessor panel with sequential starting of condensing units, coils, expansion valves, filters, single phase preventer, complete with controller and with accessories & sub-assemblies fittings etc. complete as per specifications. The unit shall deliver the rated capacity at AHRI Conditions and work even at 55°C ambient temperature without tripping. The Unit shall be constructed from heavy gauge mild steel panels and coated, on three phase, 415 Volts, 50 Hz, RUN status & Remote start/stop command including multi-connecting KIT and MS Stand with vibration isolators, necessary accessories and top up of refrigerant gas at site. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. Make: Voltas / Mitsubishi / Diakin / Hitachi / Bluestar / Haier / O General Capacity: 12 HP Module X 3 Nos. Total 36 HP Top Discharge outdoor units
Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multi speed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, including lifting, oading/unloading, and transportation charges, complete as required. Wireless remote controller etc. with ability to communicate with Central Monitoring System and corded/wireless remote controller ets. as per specifications complete as required. including Core cutting , fitting, supports, filling. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. Make: Voltas / Mitshubishi / Diakin / Hitachi / Lloyd / Bluestar / Haier Capacity: 2.6 TR (minimum)
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of inter connecting hard drawn heavy duty copper refrigerant pipe of following size for VRV/VRF system suitable for R-410A refrigerant including Y,T Joints/Headers/Refnets for SUB & connections of refrigerant pipes to units including accessories along with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS/GI/STUDS/CLAMPS/HANGERS etc. complete as required. The thickness of copper pipe shall be as per OEM standards. Make: Mandev/ Godrej / Totaline / Kwality Tubes / Papriwal
6.4 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation
9.5 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.86 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation
19 mm dia (OD) (Harddrawn) with tube thickness 1.2 mm with 19 mm thick insulation
22.2 mm dia (OD) (Harddrawn) with tube thickness 1.2 mm with 19 mm thick insulation
25.4 mm dia (OD) (Harddrawn) with tube thickness 1.2 mm with 19 mm thick insulation
28.58 mm dia (OD) (Harddrawn) with tube thickness 1.2 mm with 19 mm thick insulation
Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following nominal size. Make: Supreme / Finolex / Astral / Ashirvad Diameter: 25 mm
Supplying, Drawing & Fixing of control cum transmission wiring/power/control cabling of PVC insulated & PVC sheathed 3 crore x 1.5 sq.mm copper in suitable conduits between indoor and outdoor units and cardless remote control etc as required in the existing surface/recessed steel/ PVC conduit etc. complete as required. Make - R.R. Kabel / Finolex / Havells
Central Controller (compatible with the unit)
M/s Bhawani Air Systems
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .