Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.6 LAccepted-AOC 39 359 B PULICKAL THIRUVAMBADY POST ALAPPUZHA KERALA PIN 688 002 | ALAPPUZHA | ALAPPUZHA | KERALA | 688002 | ₹43.6 L Quoted ₹43.9 L | L1 | Accepted-AOC lowest tender |
| 2 | L2₹47.9 L+₹4.0 L (9.21%)Rejected-Finance | ₹47.9 L+₹4.0 L (9.21%) | L2 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
25 Sept 2021, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services, Garrison Engineer (Naval Services), Kataribagh, Naval Base Post, Kochi, 682 004.
ADDITION/ALTERATION AND SPECIAL REPAIR OF BUILDING NO.P-15 (HTL-1) AT NAD ALWAYE
2021_MES_457508_3
8804/E8
Open Tender
Civil Works
Item Rate
180 days
ALUVA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹80,000
Yes
29 Oct 2021
30 Aug 2021
27 Sept 2021
30 Aug 2021
25 Sept 2021
7 Sept 2021
30 Aug 2021 - 6 Sept 2021
Amount
Taking down Chowkhats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutters (without taking off shutters from the frames) complete all as directed by EIC.
Supply & Fix Blast resistant hollow metal pressed steel double leaf doors with frame, hinges, stainless steel handles, door stopper, mortise dead lock, panic bar, flush bolt, poly carbonate glass view panel, hold fast etc, and of which leaf made up of 2mm thick sheets and frame made up of 4mm thick sheets and total thickness of door leaf to be 8mm. The door should with stand explosion of 12 Kg and have blast resistance up to 7bars, fire rated for minimum 3Hours and These doors to be manufactured from high grade steel sheets, constructed as a composite panel consisting of solid steel faces with heavy duty reinforcement stiffeners as core and inside the door panel. The blast doors to be provided with suitable single/multiple EPDM gaskets for air tightness as per specifications. All the doors to be painted in two coats with high quality anti corrosive coating and paints over a coat of primer, to enhance the performance and aesthetic appearance. Full design and engineering capability to manufacture blast resistant doors to be meet desired specifications and safety standards and Testing and design of blast resistant doors that comply with latest test standards, The fire rating performance of door will be up to 180 minutes, confirming to IS : 3614 (Part-II) , IS : 4991 - 1968 and IS : 4991 - 1968BS: 476(Part- 20 & 22) entire completion all as directed and specified.
Material & Labour for Pre-cast cement concrete block masonry with solid blocks Type B1 1:3:6 (using 20mm aggregate), exceeding 10cm in width and setting in Cement Mortar 1:4 including all staging complete all as specified and directed.
Taking down cement plaster on concrete, brick or stone walls/ ceiling, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
Material & Labour for Rendering 8mm thick CM 1:4 with approved water proofing compound over back coat of 12mm thick CM 1:4 on fair faces of brickwork or concrete surfaces for external wall finished even and smooth (without using extra cement) and the junction of RCC members with wall shall be plastered after reinforced with chicken wire netting strip of GI wire of 0.91mm dia and 12mm size for a width of 30cm complete all as specified and directed. (Supply of GI Mesh to be measured separately)
Supply only integrated water proofing compound used in rendering.
Supply only chicken wire netting strip of GI wire of 0.91mm dia and 12mm size used for rendering.
Supply & Fix Gypsum Board 12mm thick in wall fixed with screw as per manufacturer’s instructions complete all as specified and directed.
Supply & Fix Plain fillets square, rectangular or triangular in section, clean sawn, secured with nails or brads exceeding 13 Sqcm & not exceeding 25 Sqcm complete all as specified and directed.
Material & Labour for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of creosote oil complete all as specified and directed.
Demolition of unreinforced cement concrete not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
Brushing neat cement slurry with 3.00 Kg of cement per Sqm with WPC complete all as specified. Note: - WPC will be measured and paid separately
Material & Labour for 25mm thick PCC 1:2:4, type B-0 using 12.5mm graded stone aggregate as in padding concrete complete all as specified and directed.
Material & Labour for 15mm thick Rendering on fair faces of concrete surfaces in CM 1:4 finished even and smooth without using extra cement with using WPC complete all as specified. Note: WPC will be measured and paid separately.
Material & Labour for applying oil based bitumen primer @ 0.20 Kg/Sqm, providing and laying 4 mm thick APP modified water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with one woven polyester mat weighing not less 160g/Sqm having softening point not less than 140 degree centigrade longitudinal tensile strength not less than 650 N/Sqm, tearing strength of 180 N torch application including minimum 10 cm side over lap & 15 cm end overlap, applying a coat of blown grade hot bitumen 90/15 over membrane @ 1.2 Kg/Sqm and applying bituminous aluminium paint @ 100 gm/Sqm complete all as specified and directed.
Dismantling of Wall and ceiling boards (fiber, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
Supply & Fix hangers 4 mm dia GI(upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60 mm long and expansion hold fasteners 12.50mm dia, 40 mm long complete all as specified and directed.
Supply & Fix aluminium snap grid of size 605x605 mm, side angle frame work of 25x25x2mm, Main Tee of 38x25x1.5mm and cross Tee of 25x25x1.4mm and complete all as specified and directed.
Material & Labour for Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturer’s instructions complete all as specified and directed.
Material & Labour for Preparation of new ceiling surface and applying two coats of oil emulsion distempering complete all as specified and directed.
Material & Labour for preparation of newly plastered surfaces of wall and apply two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
Material & Labour for preparation of newly plastered surfaces of wall and apply two coats of antifungal paint over a coat of alkali resistant primer complete all as directed by Engineer in charge.
Material & Labour for preparation of old surfaces of wall and apply one coat of antifungal paint complete all as directed by Engineer in charge.
Material & Labour for preparation of old surfaces of wall and apply one coat of oil bound distemper complete all as directed by Engineer in charge.
Material & Labour for 75mm thick PCC 1:3:6 Type C1 using 20mm graded aggregate with surface finished even and smooth without using extra cement as in plinth protection complete all as specified and directed.
Material & Labour for Cement concrete work in floor of flexural strength 40 kg/Sq cm in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete all as specified and directed.
ANTI STATIC EPOXY FLOORING (SELF SMOOTHING TOPPING) Surface Preparation: Preparing the existing surface of floor by diamond wheel grinding/scarification and cleaning by wire brushing etc, to remove all dirt, dust, oil etc to expose clean sound base concrete substrata. Conductive Flooring: Providing and laying with Electro Static Conductive floor 2mm thick in layers, including surface preparation by grinding the floor using diamond cutter grinder and primer coat using Nitoprime 25 Base & Hardener. Application of 2mm thick using self leveling epoxy Nitoflor SL Conductive of approved colour pigment after providing necessary fillers to have a uniform level over grinded or Scarified area using spike roller to obtain a uniform level surface, including first Under coat (Anti static) Nitoflor Conductive Undercoat - mix uniformly with special roller brushes including laying the copper strips of 25mm wide self adhesive copper tape with conductive adhesive in required grid pattern & connect to earth socket, over which apply second coat of (Anti static) Nitoflor Conductive Undercoat mix uniformly with special roller brushes and top layer 2mm thick self leveling epoxy (Anti-static) Nitoflor Conductive Topcoat to uniform level using nylon spike roller etc., all as per manufacturer's specifications. The surface resistance of the conductive topping in accordance with BS 2050:1978 (A-1984) and DINEN 1081, the static conductive topping including undercoat shall be in the range of 25x10 to the power of 3 ohms 1x 10 to the power of 6 ohms when tested for static decay using Metriso Megger as per Federal Test Method 101B, Method 4056. The coat shall posses a minimum compressive strength of 50 N/mm2 minimum Tensile strength of 15 N/mm2, minimum flexural strength of 28 N/mm2.
Supply & Fix Powder coated (minimum thickness of powder coating 50micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc including deco grill complete all as specified and directed.
Supply & Fix Powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
Excavating hard/dense soil in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, laying pipes, cables etc, or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out complete all as specified and directed.
Removing excavated material exceeding 250 m but n exc. 500 m and depositing where directed complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm. complete all as specified and directed.
Material & Labour for cement concrete 1:4:8 type D2 using 40mm graded aggregate in foundation complete all as specified and directed.
Material & Labour for providing cement concrete in PCC 1:2:4 Type B1 for coping using 20 mm aggregate complete all as specified and directed.
Material & Labour for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth complete all as specified and directed.
Material & Labour for Providing precast cement concrete in RCC 1:2:4 Type B1 including necessary form work, Set in cement mortar 1:4 as in cover slab complete all as specified and directed. Note: Reinforcement steel shall be paid seperately.
Material & Labour for Mild steel bars 10mmdia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
Material & Labour for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitered/stopped ends etc complete all as specified and directed.
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete and making good disturbed surfaces of walls, floors, ceiling etc complete all as specified and directed.
Material & Labour for point wiring complete with 2.5 sqmm PVC insulated (FRLS) unsheathed multi stranded copper conductor cable1100 volts grade through stove enameled steel conduit on wall/ceiling including 2.5 sqmm green colour code copper conductor (FRLS) for continuous earth wire complete all as specified and directed.
Ditto All as per Item No 40 , but using 4 sqmm cables for One 3 pin socket outlet 15 Amps on independent board.
Supply & Fix Flame proof switch rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
Supply & Fix Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed.
Supply & Fix Flame proof switch socket combined 16 Amp 230V in LM6 cable termination box, 2P+earth, With Mash room head button with NC contact cable entry 3/4" ET-2 Nos omplete all as specified and directed.
Supply & Fix Flame proof switch socket combine 32 Amp 415V, 5 Pin (P+N+E+R+Y+B) LM6 cable termination box, cable entry 3/4" ET-2 Nos complete all as specified and directed.
Supply & Fix CIMFR certified LED flameproof batten suitable for twin T8 tube of 20W, Recommended for gas/Vapor group of llA & IIB and Zone 1 & 2, IP65 Protected including LED lamp 20W complete all as specified and directed..
Supply & Fix CIMFR certified LED fitting flameproof 60W Well glass in die cast aluminium housing with heat resistant toughened glass, Recommended for gas/Vapor group of llA & IIB and Zone 1 & 2, IP65 Protected complete all as specified and directed.
Material and labour for sub main wiring with 2 runs of 2.5 Sqmm PVC insulated unsheathed single core multistranded copper conductor cable, FRLS, ISI marked and one run of 2.5 Sqmm multistranded insulated copper conductor cable, FRLS, ISI marked as earth continuity conductor drawn through stove enameled steel conduit of suitable size and all accessories, not less than 2mm thick, fire resistant, ISI marked and making good the disturbed surfaces of walls / floors / ceiling etc and including removing the existing aluminium sub main wiring cable, complete all as specified and directed. (Note: Three run of cables and one run of conduit shall be measured as One Running metre)
Material and labour for sub main wiring with 4 runs of 6 Sqmm PVC insulated unsheathed single core multistranded copper conductor cable, FRLS, ISI marked and two run of 4 Sqmm multistranded insulated copper conductor cable, FRLS, ISI marked as earth continuity conductor drawn through stove enameled steel conduit of suitable size and all accessories, not less than 2mm thick, fire resistant, ISI marked and making good the disturbed surfaces of walls / floors / ceiling etc and including removing the existing aluminium sub main wiring cable, all as specified and directed. (Note: Five run of cables and one run of conduit shall be measured as One Running metre)
Supply and fixing 12 WAY MCCB incomer VTPN distribution board made of thermoplastic polycarbonate IP66 in accordance with IEC61439-3, made of high quality Polycarbonate PC - GFS (shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, self-extinguishing, having high impact against mechanical load, made of halogen and silicon free recyclable material conform to RoHS directive 2002/92/EC, UV resistant according to IEC 61439-1, having high grade internally embedded gasket made of Polyurethane ( PUR ). Top and bottom cable entry via pre-moulded knockouts each DB Should have DIN channel for fixing MCBs/RCCBs/SPDs and with 250A vertical bus bar, earth and neutral terminal, For better safety enclosure should withstand glow wire test at 960 Degree Celsius in accordance with IEC 60 695-2-11 UL subject 94, should be flame retardant and self-extinguishing in nature. Degree of protection against mechanical load IK 08 (5 Joule) in accordance with accordance with EN IEC 62262 of size 1180x546x186mm, complete all as specified and directed.
Supply and fix Microprocessor based, MCCB 4P,100Amps,Breaking capacity 36kA, Adjustable overload setting Ir = 0.4 - 1 x In, Ics=100% Icu as per IEC 60947-II, with shunt trip 415 volts AC/DC, connecting arrangement with emergency flameproof mushroom head button all as specified and directed. Note- Flameproof mushroom head button will be measured and paid separately.
Supply & Fix Flameproof Mash room head button only off with one number NC Contact (ESTOP) complete all as specified and directed.
Supply and fix MCB SP 6 to 32 Amps,10 KA, 'C' series including dismantling old one complete all as specified and directed.
Supply and fix MCB TPN 32 Amps,10 KA, 'C' series including dismantling old one complete all as specified and directed.
Supply and fix Un-Perforated Cable tray shall be designed and tested as per IEC 61537 for communication application. The Un-Perforated cable tray shall be of confirming to DIN E 12329 for Indoor closed and dry atmospheric Application. Un-Perforated cable tray shall be interlocked for connecting the consecutive length of 3 metre tray with or without additional connectors. The thickness of the perforated tray for 60mm side height for 150 to 200mm is 0.7 mm. The Un-perforated cable tray shall be supplied with the standard length of 3 Metre. The weight bearing capacity @ 1.5 meter span distance is 150Kg/meter for 60mm side height complete all as specified and directed.
Supply and Installation of Pluggable type surge arrester for Three phase protection Class B / Type 1 as per IEC 61643 (provision for inbuilt common remote indication for defective arresters 3 nos of encapsulated spark gap to connect between Line and Neutral and one number arrester encapsulated spark gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-150 KA (10/350µ sec) Line to Neutral & 125 KA(10/350µ sec) for Neutral to Protective Earth, voltage protection level <1.3 KV ( L to N) & <1.3 KV ( N to E). Operating temp 40º to +85ºC. Response time <100 nano sec complete all as specified and directed.
Supply and fix 8 mm Aluminum Round Conductor, Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) complete all as specified and directed.
Supply and fix Roof conductor holder for sheet , Bottom section & Conductor holder made of stainless steel (V2A) with Ø 8.5 mm slot at bottom complete all as specified and directed.
Supply and fix Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor shall be of Hot Dipped & Cross sectional area of 90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IS-IEC 62305) Zinc coating: 500 g/m square (Approximately 70 micron coating) Should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding complete all as specified and directed.
Supply and fix Cross connector for Flat Suitable for 30mm Galvanised steel strip, Installed with 4 nos of hexagonal plate complete all as specified and directed.
Supply and fix Vertical air terminal with accessories Providing of Air terminals as per IS-IEC -62305 part-3 16mm rod tapered to 10 mm aluminium rod : Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE 018 5 / 305 (IS/IEC 62305) 4Mtr Air terminal: semihard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load complete all as specified and directed.
Supply and fix Accessories System consist of Fang Fix with base and clamp, on the top air terminal is erected. OBO Type No. F-FIX 16 (5403 200) Fang fix clamp made of SS, lightning tested for 100 KA 10/350 Micro wave form complete all as specified and directed.
Supply and fix 16 KG stone of 365 mm diameter, high level of stability Quick and easy mounting of interception rod using anchors. Concrete, frost-resistant, can be stacked complete all as specified and directed.
Supply and fix Test Joint suitable to connect 8mm round conductor and max by 30x3 mm GI strip with Suitable Enclosure complete all as specified and directed.
Supply and fix cross universal connector: For T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8x25 with M8 hexagonal nuts complete all as specified and directed.
Supply and fix plastic corrosion protection strip Approximately 1.1 mm thick and width 50 mm made of petrolatum coated fiber fabric complete all as specified and directed.
Supply and fix lightning counter to count number of lightning strike and it can record the date & time of the lightning incident also, tested as per IEC 62561-6. Including fixing arrangement complete all as specified and directed.
Supply, laying, jointing, testing and commissioning LT XLPE insulated, PVC sheathed armoured heavy duty electric cables LT 1100 volt grades with aluminium stranded conductor of size 95 sqmm x 3.5 core confirming to IS 7098 (Part I) of 1988 passing through pipes, in duct, on poles, in trenches, under road etc complete all as specified and directed.
Supply and laying fine dry river sand to entire width of trench as cable cushion in trench for cable complete all as specified and directed.
Supply & lay un reinforced pre cast concrete cable cover class LV type 1 flat size 250mmx150mmx40mm complete all as specified and directed.
Material & Labour for GI tubing 80 mm dia (light grade) with all necessary fittings laid in trenches/ under road crossing/ fixed on poles, wall, under floor etc including necessary clamps for fixing confirming to IS 1239 (Part-l) of 2004 complete all as specified and directed.
Material and labour for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate for erecting of Pole, supporting of bollard lights, repair of road cuttings etc all as specified and directed by Engineer-in-Charge.
Supply, erection, Testing and commissioning of thermoplastic polycarbonate IP65 outdoor free standing type LT Panel board with 200 amps rated copper bus bar, made of high quality Polycarbonate PC - GFS (shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, self-extinguishing, having high impact against mechanical load, made of halogen and silicon free recyclable material conform to RoHS directive 2002/95/EC, UV resistant according to IEC 61439-1, having high grade internally embedded gasket made of Polyurethane ( PUR ). For better safety enclosure should withstand glow wire test at 960 Deg. C in accordance with IEC 60 695-2-11 UL subject 94, should be flame retardant and self-extinguishing in nature, The panel board manufacturer shall have CPRI certification for similar panels in accordance with IEC60439-2. Fully wired as per latest electrical standards ready to use. (Size of panel without pedestal 600Wx1050Hx214Dmm) consisting the following: - A. INCOMER (a) MCCB FP, 100 Amps 25 KA 415 Volts Microprocessor type thermal adjustable setting. - 01 No B. OUTGOING (a) MCCB 4P, 415V, 63 Amps , 25 KA with thermal adjustable setting- 02 No (b) Digital Multifunction meter with suitable size of CT's. - 01 No (c) LED indication lamp - 01 set
Material & Labour for Earthing set (consisting of CPRI Tested maintenance free low carbon earth rod of 20 CU 20 mm dia, 1metre x 3 Nos 250 micron copper coated rod, Peg for easy insertion, Earth conductivity enhancing compound (10kg), Universal clamp made of SS to connect rod with flat, Polypropylene & Polyethelene (UFE) earth electrode inspection chamber with heavy duty cover, Dimension shall be 300mm x 300mm x 300mm with a weight bearing capacity of 50KN complete all as specified and directed. Note: - The cost for the earth work and other items required shall be deemed to be included in the above quoted rate.
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
Palakkal Agencies
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .