Loading…
Loading…
Tender Value
₹9.5 Cr
EMD Value
₹9.5 L
Closing Date
7 Oct 2026, 11:00 am
NBCC Bhawan
NBCC Bhawan
Construction of ICAI Bhawan- Gorakhpur situated at plot no-B-11, Taramandal, near circuit house, opp- Ramgarhtal lake, Gorakhpur (U.P.)
NBCC/SBGUPEAST/GM/VARANASI/2026/526~EWc3b77aa4ca5fe35d54c540d4
NBCC/SBGUPEAST/GM/VARANASI/2026/526
Open Tender-Domestic
Civil Works - Buildings
NBCC Bhawan
₹11,800
₹9.5 L
23 Sept 2026
23 Sept 2026
7 Oct 2026
23 Sept 2026
7 Oct 2026
S.No. DESCRIPTION DSR AMOUNT in Rs
(A) CIVIL, INTERIOR AND EXTERNAL DEVELOPMENT
1 EARTH WORK 7,56,804.78 -
2 CONCRETE WORK 6,99,565.06 -
3 REINFORCED CEMENT CONCRETE 2,43,23,124.65 -
4 BRICK WORK 27,88,745.58 -
6 WOOD, UPVC AND FRP WORK 36,71,557.15 2,68,968.00
7 STEEL WORK 7,36,960.79 -
9 FINISHING WORK 26,08,638.29 -
10 FALSE CEILING WORK 8,53,864.41 20,32,129.10
11 ALUMINIUM WORK 9,37,257.50 -
12 WATER PROOFING WORK 6,99,559.89 -
13 SIGNANGE WORKS - 4,03,800.00
14 ENTRANCE GATE 7,64,474.19 -
17 GUARD ROOM 7,48,850.43 -
18 FURNITURE WORK - 63,07,320.98
20 SW DRAIN WORKS 21,87,696.00 -
21 INTERNAL PLUMBING 11,93,158.17 10,11,263.53
22 EXTERNAL SEWER & DEVELOPMENT 4,68,334.38 18,66,715.00
Total with correction factor 0.973 as per OM CPWD dated
Signature of Tenderer 1 Signature of NBCC
1 ELECTRICAL WORKS 47,41,489.30 4,27,531.88
2 CCTV & SURVEILLIANCE SYSTEM 9,21,839.00
6 EPBAX & NETWORKING - 16,08,561.17
7 EXTERNAL ELECTRICAL WORK 44,31,536.00 35,16,111.51
9 AUDIO-VISUAL WORK 23,79,400.00
TOTAL AMOUNT(CIVIL+ E&M) 7,35,48,511.10 2,18,38,727.25
TOTAL AMOUNT(CIVIL+ E&M) 7,35,48,511.10 2,18,38,727.25
GRAND TOTAL 9,53,87,238.35
GRAND TOTAL 9,53,87,238.35
GRAND TOTAL IN LAC 953.87
GRAND TOTAL IN LAC 953.87
Signature of Tenderer 2 Signature of NBCC
Bill of Quantities Based on DSR-2023 with Cost Index & Market Rate
ICAI BHAWAN- GORAKHPUR SITUATED AT PLOT NO-B-11, TARAMANDAL, NEAR CIRCUIT HOUSE, OPP. RAMGARHTAL LAKE,
GORAKHPUR (U.P.)
Name of Work- Civil Work
BILL OF QUANTITIES
S.No DSR Item DESCRIPTION OF ITEM TOTAL DSR Amount in NON-DSR Amount in
. No. QTY UNIT Rs. Rs.
SH-2.0 EARTH WORK
1 2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over
areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting
out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-
incharge. All kinds of soil 1172.07 cum 177.50 208042.43 0.00
2 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc.
in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and
watering, lead up to 50 and for all lift. 1047.21 cum 196.00 205253.16 0.00
3 1.1.2 Earthwork is disposal upto 5km By Mechanlcal Transport lncludlng loadlng,unloadlng and
4 2.22.3 Open timbering over areas including strutting, shoring etc. complete. (Measurements to be
taken of the face area timbered): Depth exceeding 3 m but not exceeding 4.5 m 185.85 sqm 71.30 13251.11 0.00
5 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming,
consolidating and dressing complete. 56.08 cum 2123.75 119099.90 0.00
6 2.34 Supplying chemical emulsion in sealed containers including delivery as specified
2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 214.90 litre 234.75 50447.78 0.00
7 2.35 Diluting and injecting chemical emulsion for Pre-CONSTRUCTIONAL anti-termite
treatment (excluding the cost of chemical emulsion) :
2.35.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm
apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement
: 2 Coarse sand) to match the existing floor :
8 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 386.78 sqm 310.05 119921.14 0.00
Sub-Total 756804.78 0.00
SH-4.0 CONCRETE WORK
9 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of
centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-
III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from
natural sources) 83.520 cum 6812.00 568938.24 0.00
Signature of Tenderer
3 Signature of NBCC
S.No DSR Item DESCRIPTION OF ITEM TOTAL DSR Amount in NON-DSR Amount in
. No. QTY UNIT Rs. Rs.
10 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone
- III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast
40 mm nominal size, well rammed and consolidated and grouted with fine sand, including
necessary excavation, levelling & dressing & finishing the top smooth.
11 4.13 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved
quality using 1.7kg per square metre on damp proof course after cleaning the surface with
brushes and finally with apiece of cloth lightly soaked in kerosene oil.
12 4.2.3 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness)
including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string
lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,
sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and
1 :2:4 (1 Cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone
aggregate 20 mm nominal size derived from natural sources 7.630 cum 9895.20 75500.38 0.00
13 4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2
coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 40.56 sqm 410.85 16664.08 0.00
Sub-Total 699565.06 0.00
SH-5.0 REINFORCED CEMENT CONCRETE
14 5.33 Providing and laying in position ready mixed or site batched design mix cement concrete for
reinforced cement concrete work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve
durability and workability without impairing strength; including pumping of concrete to site of
laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing
reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimumspecified cement content in design mix shall be
payable separately. In case the cement content in design mix is more than 1.10 times of the
specified minimumcement content, the contractor shall have discretion to either re-design the
mix or bear the cost of extra cement.
5.33.1 All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg
Signature of Tenderer
4 Signature of NBCC
S.No DSR Item DESCRIPTION OF ITEM TOTAL DSR Amount in NON-DSR Amount in
. No. QTY UNIT Rs. Rs.
15 5.33 Providing and laying in position ready mixed or site batched design mix cement concrete for
reinforced cement concrete work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve
durability and workability without impairing strength; including pumping of concrete to site of
laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing
reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimumspecified cement content in design mix shall be
payable separately. In case the cement content in design mix is more than 1.10 times of the
specified minimumcement content, the contractor shall have discretion to either re-design the
mix or bear the cost of extra cement.
5.33.2 All works above plinth level upto floor V level Concrete of M25 grade with minimum
cement content of 330 kg /cum 546.57 cum 9860.40 5389398.83 0.00
16 5.9 Centering and shuttering including strutting, propping etc. and removal of form for
5.9.1 Foundations, footings, bases of columns, etc. for mass concre 53.10 sqm 392.15 20823.17 0.00
5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 Suspended floors, roofs, landings, balconies and access platform 1498.66 sqm 927.25 1389632.49 0.00
5.9.4 Shelves (Cast in situ) 50.00 sqm 927.25 46362.50 0.00
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantileve 1331.53 sqm 736.40 980538.69 0.00
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Strut 732.96 sqm 961.30 704594.45 0.00
5.9.16.1 Edges of slabs and breaks in floors and walls Under 20 cm wid 322.00 metre 208.55 67153.10 0.00
5.9.19 Weather shade, Chajjas, corbels etc., including edge 50.00 sqm 951.10 47555.00 0.00
17 5.22.A.6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically
Treated bars of grade Fe-500D or more.
18 5.30 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projection 1858.58 metre 78.40 145712.67 0.00
Signature of Tenderer
5 Signature of NBCC
S.No DSR Item DESCRIPTION OF ITEM TOTAL DSR Amount in NON-DSR Amount in
. No. QTY UNIT Rs. Rs.
SH-6.0 BRICK WORK
19 6.1.2 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
20 6.4.2 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar
1:6 (1 cement : 6 coarse sand)
21 6.13.2 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar
1:4 (1 cement : 4 coarse sand)
22 6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of
half brick masonry. 547.12 sqm 104.80 57338.18 0.00
SH-8.0 CLADDING WORK
23 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness t
be specified by the manufacturer), of approved make, in all colours, shades except burgundy,
bottle green, black of any size as approved by Engineer-in-Charge,in skirting, risers of steps
and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing
with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with
pigment of matching shade complete.
Signature of Tenderer
6 Signature of NBCC
S.No DSR Item DESCRIPTION OF ITEM TOTAL DSR Amount in NON-DSR Amount in
. No. QTY UNIT Rs. Rs.
24 8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished,
machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of
required size, approved shade, colour and texture laid over 20 mm thick base cement mortar
1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matchingpigment,
epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss
finish etc. complete at all levels.
25 MR Providing and fixing factory-manufactured decorative PVC fluted (baffle) wall panelling of
approved make, colour, texture, profile and pattern, comprising premium quality rigid PVC
fluted panels of approved dimensions, fixed on walls using approved high-strength polymer
adhesive and mechanical fasteners wherever required, complete in all respects as per approved
drawings and directions of the Engineer-in-Charge.
SH-9.0 WOOD, UPVC, FRP WORK, FIRE DOOR WORKS
26 9.147.A Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead
free uPVC multi-chambered frame, sach and mullion/coupler (where ever required) extruded
profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 m
foe series R3 and R4 profiles conforming to EN : 12608 in any shape, colour and design duly
reinforced with galvanized mild steel section made of required shape & size as per CPWD
Specification, uPVC extruded glazing beads, interlocks and inline sash adaptor (where ever
required) of appropriate dimension, EPDm gasket , hardware, SS 304 grade fasteners of
minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade
sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic
caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required)
shall be mitred cut and fusion welded/mechanicallyjointed duly sealed at all corners, including
drilling of holes for fixing haedware and drainage of water etc.
After Fixing frame the gap between frame and adjacent finished wall shall be filled with
weather proof sillicon sealant over backer rod of approved size and quality, all complete as per
approved drawing conforming to CPWD specification & direction of Engineer-in-charge.
Section of steel reinforcement and cross sections of uPVC Profiles to be as per design
approved by Engineer-inCharge. Wire mesh/Glazing of plain/toughened/ laminated
/double glass unit with / without high performance coatings as per design requirements and
conforming to IS :3548 & IS : 16231 shall be paid separately. Notes:- Structural
design proof cheacked from a Government Engineering Institute, to be provided by the
manufacturer for : (i) Sites with basic wind
speed >45 m/Sec as per IS 875 - Part 3. (ii) Sites with structure height more than 20m for all
9.147.B4.1 Three track panels sliding door with Aluminiumchannel for roller track, wool pile, zinc alloy
(zamak) powder coated handle on two panels along with multi-point locking system,adjustable
nylon rollers with SS 304 body. Using R3 series with frame (98 mm & above)x (40 mm &
above) & sach (30 mm & above ) x (74 mm & above).(Height upto 2.5 metre).
Signature of Tenderer
7 Signature of NBCC
S.No DSR Item DESCRIPTION OF ITEM TOTAL DSR Amount in NON-DSR Amount in
. No. QTY UNIT Rs. Rs.
27 9.1.1 Providing wood work in frames of doors, windows, clerestory windows and other frames,
wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia
& length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood
28 9..53 Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm
diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150
mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
29 9.21.1 Providing and fixing ISi marked flush door shutters conforming to IS 2202 (Part I) non-
decorative type, core of block board construction with frame of 1st class hard wood and well
matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on
both faces of shutters: 35 mm thick including ISi marked Stainless Steel butt hinges with
necessary screws 118.44 SQM 2392.65 283385.47 0.00
30 9.127.2 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss /
matt/ suede finish with high density protective surface layer and reverse side of adhesive
bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved
31 9.23. Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all
edges of flush door shutters (over all area of door shutter to be measured).
32 9.9.1.1 Providing and fixing glazed shutters for doors, windows and clerestor windows using 4 mm
thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of
required size with necessary screws. 14.85 SQM 4940.20 73361.97 0.00
33 9.96.1 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not
less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with
nuts and screws etc. complete : 300x16 mm
34 9.97 Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic0 coating not less
than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with
necessary screws etc. complete :
35 9.100.1 Providing and fixing aluminium handles, ISi marked, anodised (anodic coating not less than
grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary
screws etc. complete : :125 mm.
36 9.101.2 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic
coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and
shade, with necessary screws etc. complete. Twin rubber stopper
Signature of Tenderer
8 Signature of NBCC
S.No DSR Item DESCRIPTION OF ITEM TOTAL DSR Amount in NON-DSR Amount in
. No. QTY UNIT Rs. Rs.
37 9.84 Providing and fixing aluminium extruded section body tubular type universal hydraulic door
closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg
to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with
necessary accessories and screws etc. complete.
38 9.161 Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating
confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory
approved by Engineer-in-charge,with suitable mounting on door frame, consisting of vertical
styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out
of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool
insulation having density min 96 kg/ m³ and fixing with necessary stainless steel ball bearing
hinges of size 100x89x3mm of approved make, including applying a coat of approved fire
resistant primer or powder coating not less than 30 micron etc all complete as per direction of
Engineer-in-charge (panelling to be paid for seperately
39 9.162 Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating
confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory
approved by Engineer-in-charge,with suitable mounting on door frame, consisting of vertical
styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out
of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool
insulation having density min 96 kg/ m³ and fixing with necessary stainless steel ball bearing
hinges of size 100x89x3mm of approved make, including applying a coat of approved fire
resistant primer or powder coating not less than 30 micron etc all complete as per direction of
Engineer-in-charge (panelling to be paid for seperately
40 9.164 Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc. with
G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size
20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150
mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less
than 30 micron on G.I. beading, & special ceramic tape kerafix 2000 of 5 x 20 mm size etc
complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of
Engineer-incharge with glass of required thickness having 120 minutes of fire resistance both
integrity & radiation control (EW120) and minimum20 minutesof insulation (EI20). The glass
should be manufacturedin India. The manufacturer have to give test report/certification of fire
glass and the glass should be toughned in nature with Bi Directional Fire Protection and have
the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL
accredited lab or by any other accreditation body which operates in accordance with ISO/IEC
17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be
eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42
41 9.139 Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch &
Lock on back side of the Panic Latch of reputed brand and manufactureto be approved by the
Engineer- in- charge, all complete
42 MR Door Closer TS 71 V Std Arm 01 Nos Per Leaf
Signature of Tenderer
9 Signature of NBCC
S.No DSR Item DESCRIPTION OF ITEM TOTAL DSR Amount in NON-DSR Amount in
. No. QTY UNIT Rs. Rs.
43 MR SS ball bearing of size 100 x89x3mm
44 MR Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand
and manufacture,including providing and fixing top & bottom pivot & double acting hydraulic
floor spring type fixing arrangement and making necessary holes etc. for fixing required door
fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and
stopper etc.to be paid separately).
45 MR Door Handle
46 MR Door Lock
47 MR Providing, supplying, and fixing manually operated roller blinds of approved make and shade,
suitable for installation on windows, glazed partitions, curtain walls, and other openings,
complete in all respects. The roller blinds shall consist of premium quality, anti-static, dust-
resistant, UV-stabilized, fire-retardant (where specified), 100% polyester fabric with
acrylic/PVC coating or equivalent, having a minimum fabric weight of 300 GSM (or as per
approved manufacturer'sstandard), capable of blocking solar glare while permitting adequate
daylight. The fabric shall be colour-fast, wrinkle-resistant, mildew-resistant, and resistant to
fading under prolonged exposure to sunlight
SH-10.0 STEEL WORK
48 10.30.2 Providing & fixing glass panes with putty and glazing clips in steel doors,
windows, clerestory windows, all complete with : 5.5 mm thick glass panes
49 10.28 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates
etc., including welding, grinding, buffing, polishing and making curvature (wherever required)
and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing
with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required
size, on the top of the floor or the side of waist slab with suitable arrangement as per approval
of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be
considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
50 10.5.1 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and
3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including
applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal
Signature of Tenderer
10 Signature of NBCC
S.No DSR Item DESCRIPTION OF ITEM TOTAL DSR Amount in NON-DSR Amount in
. No. QTY UNIT Rs. Rs.
Sub-Total 736960.79 0.00
SH-11.0 FLOORING WORK
51 11.56.1 Providing and laying Polished Granite stone flooring in required design and patterns, in linear
as well as curvilinear portions of the building all complete as per the architectural drawings
with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1 :4 (1 cement
: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry
admixed with pigment of matching shade including rubbing , curing and polishing etc. all
complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab
of colour Black, Cheny/Ruby Red or equivalent 273.11 sqm 4481.30 1223887.84 0.00
52 11.20.3 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with
neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and
cleaning etc. complete, on 20 mm thick bed of cement mortar 1 :4 (1 cement: 4 coarse sand).
Dark shade pigment using ordinary cemen 313.26 sqm 1119.50 350694.57 0.00
53 MR Supply & Installation of laminated wooden flooring of suitable thikness 12mm AC5 of suitable
grade category product of approved made out of core high density -890-900kg/m3
fiberboard(HDF) & other component it treated for
abrasion,scratch,moistureprotection,flameprotection,U.Vresistant.edgetype, 0.5mm smallv-
groove, Backing under layer on min 2mm thikness AC5 shall provide as sound absorbent and
moisture protection layer the seamless impregenated decorative layer of specified
size.1215x197x8/12mmDesign,colour and pattern, all bonded together under high temperature
sand pressure with ecofriendly resin sspecified by the manufacturer, the material shall be
applicable warranty formaldended free, ecofriendly, highly recommended for high traffic area
and fully recyclable and matching shed and excluding quantity of skirting and profile.
54 12.55 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI
(solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof
and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1 :4 (1
cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in
ratio of 1 :1, including rubbing and polishing of the surface upto 3 cuts complete, including
providing skirting upto 150 mm height along the parapet walls in the same manner.
55 11.41A Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the
manufacturer) with water absorption less than 0.08% and conforming to 15:15622, of
approved brand & manufacturer,in all colours and shade, laid on 20 mm thick cement mortar 1
:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting
the joints with white cement and matching pigments etc. The tiles must be cut with the zero
chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge,
clips of required thickness, leveling system and rubber mallet for placing the tiles gently and
11.41A.1.1 Double Charge Size of Tile 600 x 600mm 8.43 sqm 1453.65 12254.27 0.00
Signature of Tenderer
11 Signature of NBCC
S.No DSR Item DESCRIPTION OF ITEM TOTAL DSR Amount in NON-DSR Amount in
. No. QTY UNIT Rs. Rs.
56 11.41A Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the
manufacturer) with water absorption less than 0.08% and conforming to 15:15622, of
approved brand & manufacturer,in all colours and shade, laid on 20 mm thick cement mortar 1
:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting
the joints with white cement and matching pigments etc. The tiles must be cut with the zero
chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge,
clips of required thickness, leveling system and rubber mallet for placing the tiles gently and
11.41A.1.3 Double Charge Size of Tile 600 x 1200 mm 639.38 sqm 1577.15 1008398.17 0.00
57 11.26.1 KOta stone slab flooring over 20 mm (average) thick base laid over and jointed with grey
cement slurry mixed with pigment to match the shade of the slab, including rubbing and
polishing complete with base of cement mortar 1 : 4 (1 cement: 4 coarse sand): 25mm Thick
58 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm
(average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement
slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing
59 11.41A.3.1 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the
manufacturer) with water absorption less than 0.08% and conforming to 15:15622, of
approved brand & manufacturer,in all colours and shade, laid on 20 mm thick cement mortar 1
:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting
the joints with white cement and matching pigments etc. The tiles must be cut with the zero
chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge,
clips of required thickness, leveling system and rubber mallet for placing the tiles gently and
easily. Glazed Vitrified tiles Matt Size of Tile 600 x 600 mm 77.90 sqm 1464.85 114111.82 0.00
60 11.13.1 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4
SH-13.0 FINISHING WORK
61 13.4.2 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand 1648.31 sqm 343.65 566441.73 0.00
62 13.15 20 mm cement plaster 1:2 (1 cement : 2 stone dust).
Signature of Tenderer
12 Signature of NBCC
S.No DSR Item DESCRIPTION OF ITEM TOTAL DSR Amount in NON-DSR Amount in
. No. QTY UNIT Rs. Rs.
63 13.82.2 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content
less than 50 grams/ litre, of approved brand and manufacture, including applying additional
coats wherever required, to achieve even shade and colour. In two or more coats
64 13.47.1 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of
required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and
including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
65 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved
brand and manufacturer,over the plastered wall surface to prepare the surface even and smooth
66 13.48.3 Finishing with Deluxe Multi surface paint system for interiors and exteriors using
Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi
Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm
over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and
Signature of Tenderer
13 Signature of NBCC
S.No DSR Item DESCRIPTION OF ITEM TOTAL DSR Amount in NON-DSR Amount in
. No. QTY UNIT Rs. Rs.
SH-12.0 FALSE CEILING WORK
67 12.52.1 Providing and fixing tiled false ceiling of specified materials of size
595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped
galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of
main 'T runner with suitably spaced joints to get required length and of size 24x38 mm made
from 0.30 mm thick (minimum)sheet, spaced at 1200 mm center to center and cross ꞏr of size
24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T"
at 600 mm center to center to fonn a grid of 1200x600 mm and secondary cross "T" of length
600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at
middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size
24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required
cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke
detectors etc. Main ~" runners to be suspended from ceiling using GI slotted cleats of size 27 x
37 x 25 x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI
adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200
mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be
pre-painted with polyester paint, all complete for all heights as per specifications, drawings
and as directed by Engineer-in-charge. GI Metal Ceiling Lay in plain Tegular edge Global
white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet
having galvanizing of 100 gms/sqm
(both sides inclusive) and electro statically polyester powder coated of thickness 60 microns
(minimum), including factory painted after bending.
Signature of Tenderer
14 Signature of NBCC
S.No DSR Item DESCRIPTION OF ITEM TOTAL DSR Amount in NON-DSR Amount in
. No. QTY UNIT Rs. Rs.
68 MR Providing & Fixing of Fibre Glass Acoustical Suspended Ceiling System with 15 mm thick
Sierra OP Tegular 15/90 Edge Tiles with Knauf Silhouette 15mm face exposed grid.
The tiles shall have smooth laminated visual with Humidity Resistance (RH) of 95%, NRC
0.85 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz
and 2000 Hz) as per ASTM C423 standard, CAC of 25db as per ASTM E1414, Light
Reflectance ≥86% as per ASTM E-1477, Thermal Conductivity λ = 0.040 W/mK, Colour
Global White, Fire Performance of class A2-s1, d0 according to EN 13501-1 with 15mm
Tegular 15/90˚ edge and 8mm drop in module size of 600 x 600mm. The scrim on the face of
the tile shall be cleanable and classified as ISO 14644-1 cleanroom class 5. It shall be suitable
for Green Building application, with Recycled content of 43% and VOC Emissions (French)
class of A+. The tile shall have Environmental Product Declaration as per ISO 14025 and EN
15804+A2. The tile shall have certifications from GRIHA and GreenPro thereby confirming
that it is an environment friendly product.
To ensure specification of tiles, ManufacturersTest Certificate is required having complete site
address & duly signed by Manufacturer.
SUSPENSION & INSTALLATION:- The tile shall be laid on KCS Silhouette 38 profile grid
system with 15mm white flanges incorporating a 6mm central reveal in white/black colour wit
mitred ends & “bird’s mouth” notches to provide mitred cruciform junctions colour global
white (Matching to tile color).Grid shall have double stroke rotary stitching on all T sections
i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all
sections). The end details of the cross tee shall be made of pre hardened steel clip fixed to the
ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee
to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a
pull out strength of more than 100kg. The T Sections shall be made of 90 gsm as per IS 277
(2003) pre-painted steel with baked polyester paint of 0T bending capability.
Perimeter trim to be Knauf wall angles of size 3000x19x19mm, secured to walls using screws
at 450mm centre to centre maximum. Installation should be carried out as per Knauf
recommended procedure using appropriate suspension system and designs as approved by the
Architect/ Engineer-in-Charge 247.19 sqm 2290.00 0.00 566065.10
69 12.53 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium
silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level,
suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising@
120 grams per sqm including both side) consisting of main 'T runner suitably spaced at joints
to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet,
spaced 1200 mm centre to centre, and cross "T" of size 24x28 mm made out of 0.33 mm
(Minimum) sheet, 1200 mm long spaced between main'T' at 600 mm centre to centre to form a
grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24 x28 mm made
of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to
from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle
pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the
help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm
interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved
texture in the grid, including, cutting/ making opening for services like diffusers, grills, light
fittings, fixtures, smoke detectors etc., wherever required. Main 'T' runners to be suspended
from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5
mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level
clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main 'T. Bottom
exposed with 24 mm of all T-sections shall be pre-painted with polyster baked paint, for all
heights, as per specifications, drawings and as directed by Engineer-in-Charge.
Signature of Tenderer
15 Signature of NBCC
S.No DSR Item DESCRIPTION OF ITEM TOTAL DSR Amount in NON-DSR Amount in
. No. QTY UNIT Rs. Rs.
70 MR Providing and Fixing horizontal level suspended metal ceilings comprising of Metalworks V-P
500 Hook-on baffle systemwith Rectangular vertical baffle blades made of Aluminium(Grade
AA 3xxx, H14 temper) in coated thickness of 0.7mm ± 0.08mm as per IS:2676 (1981), post
coated to Wooden colour, suitable for architectural finishes and Interior applications, with
single grid systemand suitable spacing between baffles. The baffle width shall be 25mm, height
shall be 100mm, length shall be 3000mm. The on-center spacing of baffles shall be 125-150mm
(clear space between baffles 100-125mm respectively). The baffles shall have plain
unperforated finish with square edge, hook-on edges with suitable upturns. The baffles shall be
electrostatically powder coated using RoHS compliant pure polyester powder to achieve
coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test
for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle
– 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an
adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E<1
using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523.
The grids shall comprise primary U-shaped slotted carrier bars of 120gsm galvanised steel (GI)
of 3000mm L x 43mm H x 30mm W x 1.5mm T. Accessories shall include baffle connector
(GI), baffle face cover (GI) – RAL shade, carrier bar splice (GI), carrier spring (SS), wall
SH-21.0 ALUMINIUM WORK
71 21.1.1.3 Providing and fixing aluminium work for doors, windows, ventilators and partitions with
extruded built up standard tubular sections/ appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia
and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with
required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,
straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium
snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per
architectural drawings and the directions of Engineer in-charge. Polyester powder coated
aluminium (minimum thickness of polyester powder coating 50 micron)
72 21.10' Providing and fixing double glazed hermetically sealed glazing in
aluminium windows, ventilators and partition etc. with 6 mm thick clear
float glass both side, having 12 mm air gap, including providing EPDM
gasket, perforated aluminium spacers, desiccants, sealant (Both primary
and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge
Sub-Total 937257.50 0.00
SH-22.0 WATER PROOFING WORK
Signature of Tenderer
16 Signature of NBCC
S.No DSR Item DESCRIPTION OF ITEM TOTAL DSR Amount in NON-DSR Amount in
. No. QTY UNIT Rs. Rs.
73 22.7.1 Providing and laying integral cement based water proofing treatment
including preparation of surface as required for treatment of roofs,
balconies, terraces etc consisting of following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement
admixed with water proofing compound conforming to IS. 2645 and
approved by Engineer-in-charge over the RCC slab including adjoining
walls upto 300 mm height including cleaning the surface before treatment.
(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm
to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse
sand) admixed with water proofing compound conforming to IS : 2645
and approved by Engineer-in-charge over 20 mm thick layer of cement
mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-in-charge
to required slope and treating similarly the adjoining walls upto 300 mm
height including rounding of junctions of walls and slabs.
(c) After two days of proper curing applying a second coat of cement slurry
using 2.75 kg/ sqm of cement admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge.
(d) Finishing the surface with 20 mm thick jointless cement mortar of mix
1:4 (1 cement :4 coarse sand) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge including
laying glass fibre cloth of approved quality in top layer of plaster and
finally finishing the surface with trowel with neat cement slurry and making
pattern of 300x300 mm square 3 mm deep.
(e) The whole terrace so finished shall be flooded with water for a minimum
period of two weeks for curing and for final test. “All above operations to be
done in order and as directed and specified by the Engineer-in-Charge”:
22.7.1 With average thickness of 120 mm and minimum thickness
at khurra as 65 mm.
Signature of Tenderer
17 Signature of NBCC
S.No DSR Item DESCRIPTION OF ITEM TOTAL DSR Amount in NON-DSR Amount in
. No. QTY UNIT Rs. Rs.
Signature of Tenderer
18 Signature of NBCC
S.No DSR Item DESCRIPTION OF ITEM TOTAL DSR Amount in NON-DSR Amount in
. No. QTY UNIT Rs. Rs.
74 22.5 Providing and laying water proofing treatment in sunken portion of WCs,
bathroom etc., by applying cement slurry mixed with water proofing
cement compound consisting of applying.
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water
proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed
to air cure for 4 hours.
(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water
proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to
air cure for 4 hours followed with water curing for 48 hours.
The rate includes preparation of surface, treatment and sealing of all
joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Sub-Total 699559.89 0.00
SH-23.0 SIGNAGE WORK
75 MR Providing, supplying, and fixing interior office room identification signages and directional
signages of approved size, design, colour, typography, and graphics as per approved signage
schedule and the directions of the Engineer-in-Charge, complete in all respects. The signages
shall be manufactured using minimum 3 mm thick acrylic sheet/ACP/aluminium composite
panel with laser-cut acrylic letters, UV-printed graphics, vinyl graphics, or equivalent
approved material, complete with matte or glossy finish as approved. The lettering, symbols,
arrows, room numbers, departmental names, accessibility symbols, pictograms, and other
graphics shall be produced using high-resolutionUV printing, laser engraving, or computer-cut
vinyl application with colour-fast inks resistant to fading, scratching, moisture, and normal
cleaning agents. Standard Office Room Name Plate (150 × 300 mm to 200 × 400 mm) 30.00 NOS 810.00 24300.00
76 MR Providing, fabricating, supplying, transporting, erecting, testing, commissioning and fixing
externally illuminated backlit building signage of approved design, shape and dimensions(16'-
0" × 4'-0" with approximately 3'-0" high letters or 20'-0" × 5'-0" with approximately 4'-0" high
letters, or as indicated in the drawings), comprising individually illuminated three-dimensional
letters, Institute logo/emblemand all associated components,complete in all respects as per the
approved drawings and directions of the Engineer-in-Charge. The item shall include
fabrication and installation of 3D illuminated channel letters and logo, ACP backing panel,
complete mild steel supporting framework, structural supports, mounting brackets, base plates,
anchor bolts, grouting, welding, cutting, drilling, alignment,levelling, anti-corrosive treatment,
primer and finish painting of all exposed steel members, complete LED illumination system
including LED modules, drivers/SMPS, timer, internal wiring, junction boxes, conduits,
weatherproof electrical accessories, cable management,electrical connections from the nearest
available power point, waterproof sealing at all fixing locations, testing, commissioningand
trial operation
Signature of Tenderer
19 Signature of NBCC
S.No DSR Item DESCRIPTION OF ITEM TOTAL DSR Amount in NON-DSR Amount in
. No. QTY UNIT Rs. Rs.
77 MR Providing, Carving, Supplying, Transporting and Fixing White Makrana Marble Statue of
Goddess Saraswati (Approx. 7 Quintals). Providing, hand-carving, supplying, transporting,
unloading, handling and fixing a 4'-0" (1200 mm) high statue of Goddess Saraswati carved
from Premium Grade-A Pure Makrana White Marble, free from cracks, veins, stains, cavities
and other visible defects. The statue shall be carved from a single or suitably jointed marble
block by skilled artisans with intricate detailing of facial features, ornaments, garments,Veena,
lotus pedestal and other traditional elements, maintaining perfect symmetry, proportion and
aesthetic appearance. The statue shall have an overall size of approximately 1200 mm height
(including base), 600 mm width and 550 mm depth, with an approximate finished weight of 7
quintals (700 kg). The exposed surfaces shall be machine and hand polished to achieve a
smooth, glossy, premium white finish while preserving all carved details.
78 MR Providing, fabricating and fixing a 300 mm high raised wooden stage over the finished floor
level for the Multipurpose Hall, comprising a rigid framework of MS square/rectangular
hollow sections of suitable sizes, duly welded, ground smooth, treated with one coat of zinc-
rich primer and two coats of synthetic enamel paint. The framework shall be adequately braced
and anchored to ensure rigidity, load-bearing capacity and vibration-free performance. The
stage top shall be formed with 19 mm thick BWP grade plywood fixed over treated timber/MS
joists as required, finished with approved 12 mm thick laminated wooden flooring having
matchingskirting, edge trims and nosing to exposed edges. The stage shall include all necessary
internal framing, stiffeners, anchor fasteners, levelling arrangements, cutting, finishing, edge
protection, concealed fixing accessories, and provisions required for a complete and durable
installation. The work shall also include providing access steps, making good all junctions,
polishing/finishing exposed members, cleaning, testing and handing over complete in all
respects as directed by the Engineer-in-Charge. Stage Height: 300 mm above finished floor
Sub-Total 0.00 403800.00
Say In Lacs. 422.87 38.26
Signature of Tenderer
20 Signature of NBCC
Bill Of Quantities Based On DSR-2023 With Cost Index & Market Rate
ICAI BHAWAN- GORAKHPUR SITUATED AT PLOT NO-B-11, TARAMANDAL, NEAR CIRCUIT
HOUSE, OPP. RAMGARHTAL LAKE, GORAKHPUR (U.P.)
Name of Work- Entrance Gate
DSR Amount NON-DSR
S.N. Ref. No. DESCRIPTION OF ITEM Qty Unit Rate In Rs.
in Rs. Amount in
SH-2.0 EARTH WORK
Earth work in excavation by mechanical means (Hydraulic
excavator)/ manual means over areas (exceeding 30 cm in
depth, 1.5 m in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth lead upto 50 m
and lift upto 1.5 m, as directed by Engineer-incharge. All
Sub-Total 6622.53 0.00
SH-4.0 CONCRETE WORK
Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All
work up to plinth level : 1:4:8 (1 Cement : 4
coarse sand (zone-III) derived from
natural sources : 8 graded stone aggregate 40 mm
nominal size derived from natural sources)
Sub-Total 13487.76 0.00
SH-5.0 REINFORCED CEMENT CONCRETE
Centering and shuttering including strutting, propping etc.
and removal of form for :
Foundations, footings, bases of columns, etc. for mass
concrete 20.74 sqm 392.15
Lintels, beams, plinth beams, girders, bressumers and
cantilevers 42.00 sqm 736.40
Signature of Tenderer 21 Signature of NBCC
DSR Amount NON-DSR
S.N. Ref. No. DESCRIPTION OF ITEM Qty Unit Rate In Rs.
in Rs. Amount in
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts 36.40 sqm 961.30 34991.32 0.00
Suspended floors, roofs, landings, balconies and access
platform 10.50 sqm 927.25
Providing and laying in position ready mixed or site batched
design mix cement concrete for reinforced cement concrete
work; using coarse aggregate and fine aggregate derived
from natural sources, Portland Pozzolana / Ordinary
Portland /Portland Slag cement, admixtures in recommended
proportions as per IS: 9103 to accelerate / retard setting of
concrete, to improve durability and workability without
impairing strength; including pumping of concrete to site of
laying, curing, carriage for all leads; but excluding the cost of
centering, shuttering, finishing and
reinforcement as per direction of the engineer-in-charge; for
the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified
cement content in design mix shall be payable separately. In
case the cement content in design mix is more than 1.10
times of the specified minimum cement content, the
contractor shall have discretion to either re-design the mix or
bear the cost of extra cement.
All works upto plinth level Concrete of M25 grade with
minimum cement content of 330 kg /cum
All works above plinth level upto floor V level Concrete
5 5.33.2.1 of M25 grade with minimum cement content of 330 kg /cum 6.26 CUM. 9,860.40 61726.10 0.00
Signature of Tenderer 22 Signature of NBCC
DSR Amount NON-DSR
S.N. Ref. No. DESCRIPTION OF ITEM Qty Unit Rate In Rs.
in Rs. Amount in
Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
6 5.22.6 above plinth level Thermo-Mechanically Treated bars of 2133.00 Kg 107.85 230044.05 0.00
grade Fe-500D or more.
Sub-Total 424223.91 0.00
SH-10.0 STEEL WORK
Structural steel work in single section, fixed with or without
connecting plate,includingcutting, hoisting, fixing in position
and applying a priming coat of approved steel primer all
Sub-Total 268262.10 0.00
SH-13.0 FINISHING WORK
12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand)
Finishing walls with Premium Acrylic Smooth exterior paint
with Silicone additives of required shade: New work (Two
9 or more coats applied @ 1.43 ltr/10 sqm over and including 101.71 SQM. 171.10 17402.58 0.00
priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Signature of Tenderer 23 Signature of NBCC
DSR Amount NON-DSR
S.N. Ref. No. DESCRIPTION OF ITEM Qty Unit Rate In Rs.
in Rs. Amount in
Finishing with Deluxe Multi surface paint system for
interiors and exteriors using Primer as per manufacturers
specifications : Painting Steel work with Deluxe Multi
10 13.48.3 Surface Paint to give an even shade. Two or more coat 36.00 SQM. 170.70 6145.20 0.00
applied @ 0.90 ltr/10 sqm over an under coat of primer
applied @ 0.80 ltr/10 sqm of approved brand and
Sub-Total 58500.42 0.00
COST FOR TWO GATE Say In Lakh 7.64 0.00
Signature of Tenderer 24 Signature of NBCC
Bill Of Quantities Based On DSR-2023 With Cost Index & Market Rate
ICAI BHAWAN- GORAKHPUR SITUATED AT PLOT NO-B-11, TARAMANDAL, NEAR CIRCUIT HOUSE,
OPP. RAMGARHTAL LAKE, GORAKHPUR (U.P.)
Name of Work- Boundary Wall
BOUNDARY WALL FOR 30.28 MTR
S. No. 2023 DESCRIPTION
UNIT Rate In Rs.
DSR Amount DSR
Item QTY in Rs. Amount
SH-2.0 EARTH WORK
1 Earth work in excavation by mechanical means (Hydraulic
excavator)/ manual means over areas (exceeding30 cm in depth,
1.5 m in width as well as 10 sqm on plan) including getting out
2.6.1 and disposal of excavated earth lead upto 50 m and lift upto 1.5 143.32 Cum 177.50 25439.30 0.00
m, as directed by Engineer-incharge. All kinds of soil
Sub-Total 25439.30 0.00
SH-4.0 CONCRETE WORK
2 Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All work
4.1.8 up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) 13.60 Cum 6812.00 92643.20 0.00
derived fromnatural sources : 8 graded stone aggregate 40
mmnominal size derived from natural sources)
3 Providing & applying a coat of residual petroleum bitumen of
grade of VG-10 of approved quality using 1.7kg per square
4.13 metre on damp proof course after cleaning the surface with 24.21 sqm 146.15 3538.29 0.00
brushes and finally with apiece of cloth lightly soaked in
Signature of Tenderer 25 Signature of NBCC
2023 TOTAL DSR Amount DSR
S. No. DESCRIPTION UNIT Rate In Rs.
Item QTY in Rs. Amount
Sub-Total 96181.49 0.00
SH-5.0 REINFORCED CEMENT CONCRETE
4 Providing and laying in position ready mixed or site batched
design mix cement concrete for reinforced cement concrete
work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary Portland
/Portland Slag cement, admixtures in recommendedproportions
as per IS: 9103 to accelerate / retard setting of concrete, to
improve durability and workability without impairing strength;
including pumping of concrete to site of laying, curing, carriage
for all leads; but excluding the cost of centering, shuttering,
5.33 finishing and
reinforcement as per direction of the engineer-in-charge;for the
following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement
content in design mix shall be payable separately. In case the
cement content in design mix is more than 1.10 times of the
specified minimum cement content, the contractor shall have
discretion to either re-design the mix or bear the cost of extra
All works upto plinth level Concrete of M25 grade with
minimum cement content of 330 kg /cum
Signature of Tenderer 26 Signature of NBCC
2023 TOTAL DSR Amount DSR
S. No. DESCRIPTION UNIT Rate In Rs.
Item QTY in Rs. Amount
5 Providing and laying in position ready mixed or site batched
design mix cement concrete for reinforced cement concrete
work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary Portland
/Portland Slag cement, admixtures in recommendedproportions
as per IS: 9103 to accelerate / retard setting of concrete, to
improve durability and workability without impairing strength;
including pumping of concrete to site of laying, curing, carriage
5.33 for all leads; but excluding the cost of centering, shuttering,
finishing and reinforcement as per direction of the engineer-in-
charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement
content in design mix shall be payable separately. In case the
cement content in design mix is more than 1.10 times of the
specified minimum cement content, the contractor shall have
discretion to either re-design the mix or bear the cost of extra
All works above plinth level upto floor V level Concrete of
M25 grade with minimum cement content of 330 kg /cum
6 Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
5.22.6 above plinth level Thermo-MechanicallyTreated bars of grade 5266.00 Kg 107.85 567938.10 0.00
Fe-500D or more.
7 Centering and shuttering including strutting, propping etc. and
5.9 removal of form for :
A Foundations, footings, bases of columns, etc. for mass concrete
Signature of Tenderer 27 Signature of NBCC
2023 TOTAL DSR Amount DSR
S. No. DESCRIPTION UNIT Rate In Rs.
Item QTY in Rs. Amount
B Lintels, beams, plinth beams, girders, bressumers and
C 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts 150.14 Sqm 961.30 144329.58 0.00
SH-6.0 BRICK WORK
Brick work with common burunt clay F.B.S. (non modular)
bricks of class designation 7.5 in superstructure above plinth
8 6.4.2 level up to floor V level in all shapes and size in: Cement mortar 20.62 Cum 9105.95 187764.69 0.00
1:6 (1 cement: 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non
modular) bricks of class designation 7.5 in superstructure above
9 6.13.1 plinth level up to floor V level. Cement mortar 1:3 (1 cement: 3 81.05 Sqm 1150.50 93248.03 0.00
Sub-Total 281012.72 0.00
SH-13.0 FINISHING WORK
10 13.4.2 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand 338.57 Sqm 343.65 116349.58 0.00
11 15 mm cement plaster on rough side of single or half brick wall
12 Finishing walls with Premium Acylic Smooth exterior paint with
Silicone additives of required shade :
13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over 587.85 Sqm 171.10 100581.14 0.00
and priming coat of exterior primer applied @ 0.90 litre / 10
Signature of Tenderer 28 Signature of NBCC
2023 TOTAL DSR Amount DSR
S. No. DESCRIPTION UNIT Rate In Rs.
Item QTY in Rs. Amount
13 Providing and applying white cement based putty of average
13.80 thickness 1 mm, of approved brand and manufacturer, over the 587.85 Sqm 156.05 91733.99 0.00
plastered wall surface to prepare the surface even and smooth
15 Finishing with Deluxe Multi surface paint system for interiors
and exteriors using Primer as per manufacturers specifications :
Painting Steel work with Deluxe Multi Surface Paint to give an
13.48.3 even shade. Two or more coat applied @ 0.90 ltr/10 sqm over 47.37 Sqm 170.70 8086.06 0.00
an under coat of primer applied @ 0.80 ltr/10 sqm of approved
brand and manufacture
Sub-Total 415303.62 0.00
SH-10.0 STEEL WORK
14 Steel work welded in built up sections/ framed work, including
cutting, hoisting, fixing in position and applying a priming coat
10.25.2 of approved steel primer using structural steel etc. as required.In 568.44 Kg 156.05 88705.06 0.00
gratings, frames, guard bar, ladder, railings, brackets, gates and
Sub-Total 88705.06 0.00
Signature of Tenderer 29 Signature of NBCC
Bill of Quantities Based on DSR-2023 with Cost Index & Market Rate
ICAI BHAWAN- GORAKHPUR SITUATED AT PLOT NO-B-11, TARAMANDAL, NEAR CIRCUIT HOUSE, OPP.
RAMGARHTAL LAKE, GORAKHPUR (U.P.)
Name of Work- INTERLOCKING PATHWAY
BILL OF QUANTITY
S. No. DSR-2023 DESCRIPTION TOTAL QTY UNIT
DSR Amount in Rs. NON-DSR Amount in Rs.
SH-2.0 EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator)/
manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well
1 2.6.1 as 10 sqm on plan) including getting out and disposal of excavated earth 17.61 Cum 177.50 3125.78 0.00
lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
Sub-Total 3125.78 0.00
SH-4.0 CONCRETE WORK
Providing and laying in position cement concrete of specified grade
4.1 excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8
2 4.1.8 graded stone aggregate 40 mm nominal size derived from natural sources) 4.07 Cum 6812.00 27724.84 0.00
Sub-Total 27724.84 0.00
SH-6.0 BRICK WORK
3 Brick work in foundation
6.1.2 Brick work with common burnt clay F.P.S. (non modular) bricks of class
(a) designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 192.53 Cum 7132.25 1373172.09 0.00
SH-13.0 FINISHING WORK
12 mm cement plaster : 1:4 (1 cement : 4 Coarse sand) mortar etc.
Sub-Total 35163.24 0.00
SH-16.0 ROAD WORK
Signature of Tenderer 30 Signature of NBCC
S. No. DSR-2023 DESCRIPTION TOTAL QTY UNIT
DSR Amount in Rs. NON-DSR Amount in Rs.
Providing and laying factory made chamfered edge Cement Concrete paver
blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of
required strength, thickness & size/ shape, made by table vibratory method
using PU mould, laid in required colour & pattern over 50mm thick
compacted bed of sand, compacting and proper embedding/laying of inter
5 locking paver blocks into the sand bedding layer through vibratory 429.09 Sqm 1045.65 448677.96 0.00
16.91 compaction by using plate vibrator, fillingthe joints with sand and cutting of
paver blocks as per required size and pattern, finishing and sweeping extra
sand. complete all as per direction of Engineer-in-Charge.
60 mm thick C.C. paver block of M-35 grade with approved color
design and pattern
Sub-Total 448677.96 0.00
Signature of Tenderer 31 Signature of NBCC
Bill of Quantities Based on DSR-2023 with Cost Index & Market Rate
ICAI BHAWAN- GORAKHPUR SITUATED AT PLOT NO-B-11, TARAMANDAL, NEAR CIRCUIT HOUSE, OPP.
RAMGARHTAL LAKE, GORAKHPUR (U.P.)
Name of Work- Civil Work- Guard Room
TOTAL Rate In DSR Amount in NON-DSR
S.No. DSR Item No. DESCRIPTION OF ITEM UNIT
QTY Rs. Rs. Amount in Rs.
SH-2.0 EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual
means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm
on plan) including getting out and disposal of excavated earth lead upto 50 m
and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil 39.97 cum 177.50 7094.68 0.00
Supplying and filling in plinth with sand under floors, including watering,
2 2.27 ramming, consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as
2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 10.35 litre 234.75 2429.66 0.00
Diluting and injecting chemical emulsion for Pre-CONSTRUCTIONAL anti-
4 2.35 termite treatment (excluding the cost of chemical emulsion) :
Treatment of soil under existing floors using chemical emulsion @ one litre per
hole, 300 mm apart including drilling 12 mm diameter holes and plugging with
cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor :
2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 18.62 sqm 310.05 5773.13 0.00
Sub-Total 18100.82 0.00
SH-4.0 CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding
the cost of centering and shuttering - All work up to plinth level :
5 4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8
graded stone aggregate 40 mm nominal size derived from natural sources)
Signature of Tenderer 32 Signature of NBCC
TOTAL Rate In DSR Amount in NON-DSR
S.No. DSR Item No. DESCRIPTION OF ITEM UNIT
QTY Rs. Rs. Amount in Rs.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of
approved quality using 1.7kg per square metre on damp proof course after
cleaning the surface with brushes and finally with apiece of cloth lightly soaked
in kerosene oil. 5.45 sqm 146.15 796.52 0.00
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4
(1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3
coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over
75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and
8 4.17 consolidated and grouted with fine sand, including necessary excavation,
levelling & dressing & finishing the top smooth.
Sub-Total 55155.87 0.00
SH-5.0 REINFORCED CEMENT CONCRETE
Providing and laying in position ready mixed or site batched design mix cement
concrete for reinforced cement concrete work; using coarse aggregate and fine
aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland
/Portland Slag cement, admixtures in recommended proportions as per IS: 9103
to accelerate / retard setting of concrete, to improve durability and workability
without impairing strength; including pumping of concrete to site of laying,
9 5.33 curing, carriage for all leads; but excluding the cost of centering, shuttering,
reinforcement as per direction of the engineer-in-charge; for the following grades
Note: Extra cement up to 10% of the minimum specified cement content in
design mix shall be payable separately. In case the cement content in design mix
is more than 1.10 times of the specified minimum cement content, the contractor
h ll h di ti t ith d i th i b th t f t t
All works upto plinth level Concrete of M25 grade with minimum cement
Signature of Tenderer 33 Signature of NBCC
TOTAL Rate In DSR Amount in NON-DSR
S.No. DSR Item No. DESCRIPTION OF ITEM UNIT
QTY Rs. Rs. Amount in Rs.
Providing and laying in position ready mixed or site batched design mix cement
concrete for reinforced cement concrete work; using coarse aggregate and fine
aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland
/Portland Slag cement, admixtures in recommended proportions as per IS: 9103
to accelerate / retard setting of concrete, to improve durability and workability
without impairing strength; including pumping of concrete to site of laying,
curing, carriage for all leads; but excluding the cost of centering, shuttering,
10 5.33 finishing and
reinforcement as per direction of the engineer-in-charge; for the following grades
Note: Extra cement up to 10% of the minimum specified cement content in
design mix shall be payable separately. In case the cement content in design mix
is more than 1.10 times of the specified minimum cement content, the contractor
shall have discretion to either re-design the mix or bear the cost of extra cement.
All works above plinth level upto floor V level Concrete of M25 grade with
minimum cement content of 330 kg /cum 4.41 cum 9860.40 43484.36 0.00
Steel reinforcement for R.C.C. work including straightening, cutting, bending,
placing in position and binding all complete upto plinth level & above plinth
11 5.22.A.6 level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form
5.9.1 Foundations, footings, bases of columns, etc. for mass concrete 10.92 sqm 392.15 4282.28 0.00
5.9.3 Suspended floors, roofs, landings, balconies and access platform 13.21 sqm 927.25 12248.97 0.00
5.9.4 Shelves (Cast in situ) 1.82 sqm 927.25 1687.60 0.00
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers 33.51 sqm 736.40 24676.76 0.00
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts 22.39 sqm 961.30 21523.51 0.00
5.9.16.1 Edges of slabs and breaks in floors and walls Under 20 cm wide 20.65 metre 208.55 4306.56 0.00
5.9.19 Weather shade, Chajjas, corbels etc., including edges 2.88 sqm 951.10 2739.17 0.00
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C.
13 5.30 projections.
Sub-Total 275559.77 0.00
SH-6.0 BRICK WORK
Signature of Tenderer 34 Signature of NBCC
TOTAL Rate In DSR Amount in NON-DSR
S.No. DSR Item No. DESCRIPTION OF ITEM UNIT
QTY Rs. Rs. Amount in Rs.
Brick work with common burnt clay F.P.S. (non modular) bricks of class
14 6.1.2 designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6
Brick work with common burnt clay F.P.S. (non modular) bricks of class
15 6.4.2 designation 7.5 in superstructure above plinth level up to floor V level in all
shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 13.32 cum 9105.95 121291.25 0.00
Brick work with common burnt clay F.P.S. (non modular) bricks of class
16 6.13.2 designation 7.5 in superstructure above plinth level up to floor V level in all
shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) 9.29 sqm 1123.80 10440.10 0.00
Sub-Total 158334.64 0.00
SH-9.0 WOOD, UPVC AND FRP WORK
Providing and fixing ISi marked flush door shutters conforming to IS 2202
(Part I) non-decorative type, core of block board construction with frame of 1st
17 9.5.1.1 class hard wood and well matched commercial 3 ply veneering with vertical
grains or cross bands and face veneers on both faces of shutters: 35 mm thick
including ISi marked Stainless Steel butt hinges with necessary screws
35 mm thick including ISI marked Stainless Steel butt hinges with necessary
18 9.127.2 Providing & Fixing decorative high pressure laminated sheet of plain / wood
grain in gloss / matt/ suede finish with high density protective surface layer and
reverse side of adhesive bonding quality conforming to IS : 2046 Type S,
including cost of adhesive of approved quality.
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum
depth on all edges of flush door shutters (over all area of door shutter to be
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic
coating not less than grade AC 10 as per IS : 1868), transparent or dyed to
20 9.96.1 required colour or shade, with nuts and screws etc. complete : 300x16 mm
Signature of Tenderer 35 Signature of NBCC
TOTAL Rate In DSR Amount in NON-DSR
S.No. DSR Item No. DESCRIPTION OF ITEM UNIT
QTY Rs. Rs. Amount in Rs.
Providing and fixing aluminium tower bolts, ISI marked, powder coated
(minimum thickness of powder coating 50 micron) transparent or dyed to
21 9.97 required colour or shade, with necessary screws etc. complete : 250x10 mm.
Providing and fixing aluminium handles, ISI marked, powder coated (minimum
thickness of powder coating 50 micron) transparent or dyed to required colour or
22 9.100.1 shade, with necessary screws etc. complete :125 mm.
Providing and fixing aluminium hanging floor door stopper, ISI marked,
anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent
23 9.101.2 or dyed to required colour and shade, with necessary screws etc. complete. Twin
Providing and fixing aluminium die cast body tubular type universal hydraulic
door closer (having brand logo with ISI, IS : 3564, embossed on the body, door
24 9.83 weight upto 35 kg and door width upto 700 mm), with necessary accessories and
screws etc. complete.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-
section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive
shutter of 30 mm thickness. The laminate shall be moulded with fire resistant
25 9.121 grade unsaturated polyester resin and chopped mat. Door frame laminate shall be
2mm thick and shall be filled with suitable wooden block in all the three legs.
The frame shall be covered with fiber glass from all sides. M.S. stay shall be
provided at the bottom to steady the frame 6.00 meter 570.95 3425.70 0.00
30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of
required colour and approved brand and manufacture, made with fire - retardant
grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for
26 9.122.1 forming hollow rails and styles, with wooden frame and suitable blocks of
seasoned wood inside at required places for fixing of fittings, cast monolithically
with 5 mm thick FRP laminate for panels conforming to IS: 14856, including
fixing to frames
Sub-Total 25416.76 0.00
Signature of Tenderer 36 Signature of NBCC
TOTAL Rate In DSR Amount in NON-DSR
S.No. DSR Item No. DESCRIPTION OF ITEM UNIT
QTY Rs. Rs. Amount in Rs.
SH-10.0 STEEL WORK
Providing and fixing M.S. Tubular frames and shutters for doors, windows,
ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm
thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of
27 10.15 required size, including fixing of necessary butt hinges and screws and applying
a priming coat of approved steel primer.
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block
10.15.1 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate
20 mm nominal size)
Steel work welded in built up sections/ framed work, including cutting, hoisting,
28 10.25 fixing in position and applying a priming coat of approved steel primer using
structural steel etc. as required.
In grill, gratings, frames, guard bar, ladder, railings, brackets, gates and similar
Providing & fixing glass panes with putty and glazing clips in steel
29 10.30 doors,windows, clerestory windows, all complete with :
Sub-Total 22973.72 0.00
SH-13.0 FINISHING WORK
30 13.4.2 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 56.72 sqm 343.65 19492.52 0.00
31 13.5 15 mm cement plaster on the rough side of single or half brick wall of mix :
Distempering with 1st quality acrylic distemper (ready mixed) having VOC
content less than 50 gram/litre, of approved manufacturer and of required shade
and colour all complete to achieve even shade and colour :
New work (two or more coats) over and including water
13.41.1 thinnable priming coat with cement primer having VOC content less than 50
Signature of Tenderer 37 Signature of NBCC
TOTAL Rate In DSR Amount in NON-DSR
S.No. DSR Item No. DESCRIPTION OF ITEM UNIT
QTY Rs. Rs. Amount in Rs.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone
additives of required shade: New work (Two or more coats applied @
1.43 ltr/10 sqm over and including priming coat of exterior primer applied @
Providing and applying white cement based putty of average thickness 1 mm, of
34 13.80 approved brand and manufacturer, over the plastered wall surface to prepare the
surface even and smooth Complete.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two
35 13.48.3 or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @
0.80 ltr/ 10 sqm of approved brand and manufacture 8.46 sqm 170.70 1444.12 0.00
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or
36 13.48.2 more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75
ltr/10 sqm of approved brand and manufacture
Sub-Total 104219.39 0.00
SH-16.0 ROAD WORK
Providing and laying factory made 80 mm thick rubber moulded Interlocking
cement concrete tiles (30mpa) including 25 mm thick compacted bed of fine sand
compacting and proper embedding/laying of Interlocking tiles leveling and
37 16.68 dressing of surface to required level and slope, filling joints with fine sand
including the cost of material, labour T&P etc. required for proper completion of
work as directed by Engineer-in-Charge.
Sub-Total 8748.00 0.00
SH-11.0 FLOORING WORK
Providing and laying vitrified floor tiles in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and
conforming to IS: 15622, of approved make, in all colours and shades, laid on
38 11.41 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey
cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement
and matching pigments etc., complete.
Signature of Tenderer 38 Signature of NBCC
TOTAL Rate In DSR Amount in NON-DSR
S.No. DSR Item No. DESCRIPTION OF ITEM UNIT
QTY Rs. Rs. Amount in Rs.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by
manufacturer), with water absorption less than 0.08 % and conforming to I.S.
15622, of approved make, in all colours & shade, in skirting, riser of steps, over
39 11.46.2 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with
grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement
& matching pigments etc. complete. 0.99 sqm 1623.05 1606.82 0.00
11.41A.3.1 Providing and laying Vitrified tiles in floor in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and
conforming to 15:15622, of approved brand & manufacturer, in all colours and
shade, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse sand) jointing
40 with grey cement slurry @3.3 kg/sqm including grouting the joints with white
cement and matching pigments etc. The tiles must be cut with the zero chipping
diamond cutter only. Laying of tiles will be done with the notch trowel, plier,
wedge, clips of required thickness, leveling system and rubber mallet for placing
the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size.
Size of Tile 600 x 600 mm
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40
41 11.13.1 mm wide and 4 mm thick
Sub-Total 28254.22 0.00
SH-8.0 CLADDING WORK
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:
15622 (thickness to be specified by the manufacturer), of approved make, in all
colours, shades except burgundy, bottle green, black of any size as approved by
42 8.31 Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed
of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement
slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment
of matching shade complete 18.48 sqm 1267.95 23431.72 0.00
Sub-Total 23431.72 0.00
SH-22.0 WATER PROOFING WORK
Signature of Tenderer 39 Signature of NBCC
TOTAL Rate In DSR Amount in NON-DSR
S.No. DSR Item No. DESCRIPTION OF ITEM UNIT
QTY Rs. Rs. Amount in Rs.
43 22.7.1 Providing and laying integral cement based water proofing treatment
including preparation of surface as required for treatment of roofs,
balconies, terraces etc consisting of following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement
admixed with water proofing compound conforming to IS. 2645 and
approved by Engineer-in-charge over the RCC slab including adjoining
walls upto 300 mm height including cleaning the surface before treatment.
(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm
to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse
sand) admixed with water proofing compound conforming to IS : 2645
and approved by Engineer-in-charge over 20 mm thick layer of cement
mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-in-charge
to required slope and treating similarly the adjoining walls upto 300 mm
height including rounding of junctions of walls and slabs.
(c) After two days of proper curing applying a second coat of cement slurry
using 2.75 kg/ sqm of cement admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge.
(d) Finishing the surface with 20 mm thick jointless cement mortar of mix
1:4 (1 cement :4 coarse sand) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge including
laying glass fibre cloth of approved quality in top layer of plaster and
finally finishing the surface with trowel with neat cement slurry and making
pattern of 300x300 mm square 3 mm deep.
(e) The whole terrace so finished shall be flooded with water for a minimum
period of two weeks for curing and for final test. “All above operations to be
done in order and as directed and specified by the Engineer-in-Charge”:
22.7.1 With average thickness of 120 mm and minimum thickness
at khurra as 65 mm.
Signature of Tenderer 40 Signature of NBCC
TOTAL Rate In DSR Amount in NON-DSR
S.No. DSR Item No. DESCRIPTION OF ITEM UNIT
QTY Rs. Rs. Amount in Rs.
22.5 Providing and laying water proofing treatment in sunken portion of WCs,
bathroom etc., by applying cement slurry mixed with water proofing
cement compound consisting of applying.
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water
proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed
to air cure for 4 hours.
44 (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water
proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to
air cure for 4 hours followed with water curing for 48 hours.
The rate includes preparation of surface, treatment and sealing of all
joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Sub-Total 28655.52 0.00
Signature of Tenderer 41 Signature of NBCC
Bill of Quantities Based on DSR-2023 with Cost Index & Market Rate
ICAI BHAWAN- GORAKHPUR SITUATED AT PLOT NO-B-11, TARAMANDAL, NEAR CIRCUIT HOUSE,
OPP. RAMGARHTAL LAKE, GORAKHPUR (U.P.)
Name of Work- UG TANK
Rate In DSR Amount
S. N. Item No. DESCRIPTION OF ITEM TOTAL QTY UNIT Amount in
SH-2.0 EARTH WORK
1 2.6.1 Earth work in excavation by mechanical means (Hydraulic
excavator)/ manual means over areas (exceeding 30 cm in depth,
1.5 m in width as well as 10 sqm on plan) including getting out
and disposal of excavated earth lead upto 50 m and lift upto 1.5
m as directed by Engineer incharge
Sub-Total 37901.58 0.00
SH-4.0 CONCRETE WORK
2 4.1.8 Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All work
up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III)
derived from natural sources : 8 graded stone aggregate 40 mm
nominal size derived from natural sources)
Sub-Total 29155.36 0.00
SH-5.0 REINFORCED CEMENT CONCRETE
Signature of Tenderer 42 Signature of NBCC
Rate In DSR Amount
S. N. Item No. DESCRIPTION OF ITEM TOTAL QTY UNIT Amount in
3 5.33 Providing and laying in position ready mixed M-25 grade
concrete for reinforced cement concrete work, using cement
content as per approved design mix, manufactured in fully
automatic batching plant and transported to site of work in
transit mixer for all leads, having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced
cement concrete work, including pumping of R.M.C. from transit
mixer to site of laying , excluding the cost of centering,
shuttering finishing and reinforcement, including cost of
admixtures in recommended proportions as per IS : 9103 to
accelerate/ retard setting of concrete, improve workability
without impairing strength and durability as per direction of the
Engineer-in-charge.
(Note :- Cement content considered in this item is @ 330 kg/
cum Excess/less cement used as per design mix is
5.33.1 All works upto plinth leve 52.32 cum 9504.75 497288.52 0
4 5.33 Providing and laying in position ready mixed M-25 grade
concrete for reinforced cement concrete work, using cement
content as per approved design mix, manufactured in fully
automatic batching plant and transported to site of work in
transit mixer for all leads, having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced
cement concrete work, including pumping of R.M.C. from transit
mixer to site of laying , excluding the cost of centering,
shuttering finishing and reinforcement, including cost of
admixtures in recommended proportions as per IS : 9103 to
accelerate/ retard setting of concrete, improve workability
without impairing strength and durability as per direction of the
Engineer-in-charge.
(Note :- Cement content considered in this item is @ 330 kg/
cum Excess/less cement used as per design mix is
5.33.2 All works above plinth level upto floor V leve 2.93 cum 9860.40 28890.97 0
Signature of Tenderer 43 Signature of NBCC
Rate In DSR Amount
S. N. Item No. DESCRIPTION OF ITEM TOTAL QTY UNIT Amount in
5 5.9 Centering and shuttering including strutting, propping etc. and
removal of form for
5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
5.9.2 Walls (any thickness) including attached pilasters, butteresses,
plinth and string courses etc 192.00 sqm 842.50 161760 0
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Strut 36.00 sqm 961.30 34606.8 0
5.9.3 Suspended floors, roofs, landings, balconies and access platform
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
6 5.22.6 Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
upto plinth level & above plinth level. Thermo-Mechanically
Treated bars of grade Fe-500D or more 94.61 qtl. 10785.00 1020368.85 0
SH-13.0 FINISHING WORK
7 13.4.2 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand 133.92 sqm 343.65 46021.61 0
Sub-Total 46021.61 0.00
SH-19.0 DRAINAGE WORK
8 19.19.2 Supplying and fixing C.I. cover without frame for manholes :50
mm diameter C.I. cover (medium duty) the weight of the cover t
be not less than 58 kg 3.00 each 3441.20 10323.6 0
9 19.15.1 Providing M.S. foot rests including fixing in manholes with
20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse
sand : 6 graded stone aggregate 20 mm nominal size) as per
standard design : With 20x20 mm square bar 51.00 Nos. 544.70 27779.7 0
Sub-Total 38103.30 0.00
SH-22.0 WATER PROOFING WORK
Signature of Tenderer 44 Signature of NBCC
Rate In DSR Amount
S. N. Item No. DESCRIPTION OF ITEM TOTAL QTY UNIT Amount in
10 22.23 (AR) Providing and applying integral crystalline slurry of hydrophilic
in nature for waterproofing treatment to the RCC structures like
retaining walls of the basement, water tanks, roof slabs,
podiums, reservior, sewage & water treatment plant, tunnels /
subway and bridge deck etc., prepared by mixing in the ratio of
5 : 2 (5 parts integral crystalline slurry : 2 parts water) for
vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1
part water) for horizontal surfaces and applying the same from
negative (internal) side with the help of synthetic fiber brush.
The material shall meet the requirements as specified in ACI-
212-3R-2010 i.e by reducing permeability of concrete by more
than 90% compared with control concrete as per DIN 1048 and
resistant to 16 bar hydrostatic pressure on negative side. The
crystalline slurry shall be capable of self-healing of cracks up to
a width of 0.50mm. The work shall be carried out all complete
as per specification and the direction of the engineer-in- charge.
The product performance shall carry guarantee for 10 years
22.23.1 For vertical surface two coats @ 0.70 kg per sqm
22.23.2 For horizontal surface one coat @1.10 kg per sqm 21.11 sqm 362.80 7658.71 0
11 22.26 Providing and applying of swellable type water stop tape, 19 mm
x 25 mm thick in linear metre (expansive nature) for
construction joints treatment of RCC structure such as raft slab,
retaining walls, water storage tank and at the junctions of raft
slab with the retaining walls etc.. After cleaning the surface, one
coat of required primer for swellable water stop tape shall be
applied throughout the length of the joint @3.78 litre per 240
running metre. Over the primed surface swellable type water
stop tape shall be placed. The work shall be carried out all
complete as per specification and the direction of the Engineer-I
Charge. The product performance shall carry guarantee for 10
years against any leakage. 38.05 Rm 573.45 21819.77 0
Signature of Tenderer 45 Signature of NBCC
Rate In DSR Amount
S. N. Item No. DESCRIPTION OF ITEM TOTAL QTY UNIT Amount in
12 22.7.1 Providing and laying integral cement based water proofing
including preparation of surface as required for treatment of
balconies, terraces etc consisting of following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of
admixed with water proofing compound conforming to IS. 2645
approved by Engineer-in-charge over the RCC slab including
walls upto 300 mm height including cleaning the surface before
(b) Laying brick bats with mortar using broken bricks/brick bats
(d) Finishing the surface with 20 mm thick jointless cement
1:4 (1 cement :4 coarse sand) admixed with water proofing
conforming to IS : 2645 and approved by Engineer-in-charge
laying glass fibre cloth of approved quality in top layer of plaster
finally finishing the surface with trowel with neat cement slurry
pattern of 300x300 mm square 3 mm deep.
(e) The whole terrace so finished shall be flooded with water for
period of two weeks for curing and for final test. “All above
operations to be
done in order and as directed and specified by the Engineer-in-
22.7.1 With average thickness of 120 mm and minimum 26.46 sqm 1684.60 44574.52 0
Signature of Tenderer 46 Signature of NBCC
Rate In DSR Amount
S. N. Item No. DESCRIPTION OF ITEM TOTAL QTY UNIT Amount in
Sub-Total 128795.90 0.00
Signature of Tenderer 47 Signature of NBCC
ICAI BHAWAN- GORAKHPUR SITUATED AT PLOT NO-B-11,
TARAMANDAL, NEAR CIRCUIT HOUSE, OPP. RAMGARHTAL
LAKE, GORAKHPUR (U.P.)
Name of Work- Drain
COST OF RCC DRAIN (600 TO 1500)MM X (1200 TO 1500) MM
S.No. DESCRIPTION No. L B D/H QTY
LENGTH OF DRAIN
Along the Boundary 1 120.000 120.00
SAY IN LAC 21.88
Signature of Tenderer 48 Signature of NBCC
Detailed Estimate Based On DSR-2025 With Cost Index & Market Rate
ICAI BHAWAN- GORAKHPUR SITUATED AT PLOT NO-B-11, TARAMANDAL, NEAR CIRCUIT HOUSE, OPP. RAMGARHTAL LAKE, GORAKHPUR (U.P.)
Name Of Work -External Electrical Work
Rate as per D.S.R. 2025 MARKET BASED
Sr.No. Sch. No. Particulars Qty Unit Amount Rate Amount
A Subhead-I HT Work
1 11 KV DOUBLE POLE STRUCTURE
Supply, erection, testing and commissioning of 2 pole structure for providing 1
MR No. 11KV,200A GOS in accordance with IE rules, & local authority 1.00 Set 1,25,000.00 1,25,000.00
specification and drawings and comprising of the following.
a. 2 Nos. 11 mtr. long MS STEEL poles complete with, pole excavation, MS
STEEL foundation, and back filling complete MS steel channel/angle iron etc.
b. 1 Set of cross arms, branching, clamps and painting complete with GI nut,
bolts & washers as required (for GO & DO), LA connection.
c .1 set 11KV Insulator complete with spindles & hardware complete as
d .1 No. 11KV 400A TP Gang operated Air break switches complete with
25mm dia GI pipe operating machanism, handle & locking arrangement.
e. 1 set of 3 nos.11KV single pole drop out fuse complete with barrel fuses, an
mounting arrangement.
f. 1 set (3 nos.) 11KV lightning arrestor and connecting to all phases. - -
g. 4 No. 150 mm dia 6 meter long GI pipe class 'B' (for XLPE cable
protection) as required.
h. 2 Set 50mm dia 3m long GI pipe earting with 25 x 6 mm GI earth strip
complete as required (for GO & DO & LA)
i 1 nos. 11KV HT danger boards and 2 set of anticlimbing devices. - -
11 KV Double Pole Structure described below - -
Supply of 3 core standered aluminium conductor XLPE (Cross linked
polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured
cables confirming to I.S. 7098 (Part-II with latest amendments) II KV grade as
per requirement.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable
3 22.3 of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe - - -
supplying and making indoor cable end termination with heat
shrinkable jointing kit complete with all accessories including lugs suitable for
following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as
Signature of Tenderer
49 Signature of NBCC
Supplying and making outdoor cable end termination with heat shrinkable
jointing kit complete with all accessories including lugs suitable for following
5 23.5 size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : - - -
Supply and laying of 1800mm x 900mm x 12mm thick chequered rubbbber
matting of tested quality.
Supply and fixing of shock treatment chart (prescribed under I.E. rules) duly
7 MR framed with glass and supported from back with hard board or soft board with 3.00 Each - 247.98 743.93
supply of all material labour T&P for proper completion of work.
Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked
IS : 2878 & TAC approved) complete with initial charge and wall bracket,
along with supply of all materials and labour for proper completion of work.
Supply and laying of PVC Insulated, FRLS Round Sheathed Multi Core
Industrial Flexible Cable conforming to IS 694:2010 with Flexible Bright
9 Annealed Copper Conductor for Voltage Grade 1100 Volts as per direction of - - -
engineer incharge.
HT Panel - - -
Supply, erection, testing and commissioning of 1 panel, 630A ,11 kV, 3 Phase,
50 Hz., metal clad, dead front, 350 MVA rupturing capacity Vacuum Circuit
Breaker Incoming & Outgoings as per the detailed specifications and drawings
Outgoings as per the detailed specifications and drawings including
10 connections etc. complete with following in-comers including connections etc. - - -
complete with following in-comers and out-goings including door interlocking
panel should be expendable type complete as per technical specifications and a
A. INCOMER 1nos.: -
i) 1 No. VCB having following -
1 No. 630A, 11kV, 3 Phase, 50Hz., metal clad, dead front, 350 MVA
rupturing capacity, Fully Drawout type, Vacuum Circuit Breaker (VCB)
1 set of 11kV/110V Potential Transformers with MCB -
1 Set of Phase indicating lamps with MCB -
1 No. 0-11 kV Digital voltmeter with selector switch -
1 set of indicating lamps to indicate OPEN, CLOSE, TRIP,SPRING
CHARGED, TRIP CIRCUIT HEALTHY
Push button for ON, OFF,TRIP&TRIP circuit healthy -
1 set of 80/5-5A Current Transformer for metering and protection -
1 No. 0-100 digital Amps ammeter with selector switch -
1 Set of CDG 31 (2 No. O/C, 1 No. E/F) relay -
Digital frequency meter,Digital Tri vector meter. -
I Set of undervoltage relay and Overvoltage relay -
Trip circuit supervision relay,Auxiliary relays with shunt trip coil -
Signature of Tenderer
50 Signature of NBCC
I No. Master Trip relay -
1 No. Digital Power factor meter -
Total For Subhead-I HT Work 1,73,394.00 12,13,580.47
B Subhead-II Transformer
1 TRANSFORMER - -
11/0.433 KV, 3 Phase, 50 Hz outdoor/ indoor mounting(Mineral oil
Supply, installation, testing and commissioning of following capacity
(continuous loading) BEE 5 Star rated (Corresponding Level as per BIS
amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50
Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound
transformer (Electrolytic grade 99.9% pure copper, Core made of first
grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better,
suitable for out door/indoor applications with On Load Tap Changer (OLTC)
on HV side having AVR relay and Remote Tap Changer Control (RTCC) for
automatic sensing of incoming voltage, automatic operation of OLTC and
facility for remote and manual operation of OLTC HV side in range of +5% to
-15% in steps of 2.5%, having cable end boxes on HV side suitable for -
3x300 sqmm XLPE cable of 11 KV grade, including bus trunking
arrangement on LV side including supplying and laying of copper conductor
multicore control cable from transformer to HT breaker/panel for safety
tripping, complete with all accessories and safety provisions as per relevant
IS Code including first filling of filtered dehydrated oil, i/c supplying and
grouting of suitable M.S. Channel with all accessories and transformer shall
be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and duly ISI Marked
as per CPWD specifications complete in all respects etc as required at site.
The maximum flux density in any part of the core and yoke at rated voltage
and frequency shall be such that the flux density with + 12.5 percent
combined voltage and frequency variation from rated voltage and frequency
does not exceed 1.9 Tesla. The permissible temperature-rise shall not
exceed 35 dg.C for oil and 40 dg. C up to 200 KVA and 40 dg.C for oil and 45
dg. C for above 200 KVA for winding. Inside of tank shall be painted with
varnish or liquid resistant paint. For external surfaces one coat of thermo
setting powder paint or one coat of epoxy primer followed by two coats of -
polyurethane base paint shallbe used. IS: 1180 (Part 3) shall be referred to
for paint thickness for normal to medium corrosive atmosphere. For highly
polluted atmosphere and special application external paint work shall be as
per direction of Engineer-in-Charge. Design ambient condition : a) air
temperature 50 deg C, b) Relative Humidity 90 % Max, c) Seismic Zone as
Signature of Tenderer
51 Signature of NBCC
per location of site, d) Altitude as per location/site. Noise level Shall not
exceed limits as per NEMA TR-1 with all accessories running measured as
per IEC 551 / NEMA standard. The transformer should have QR code which
should contain drawing, test report OEM manual,Geo- Tag of manufacturing
location etc. Marking Each transformer shall be provided with rating plate -
made of anodized aluminum/ stainless steel material securely fixed on the
outer body, easily accessible,as per IS: 1180 Part-3. The entries on the rating
plate shall be indelibly marked.
Fitting and Accessories : The following fittings shall be provided:- a) Two
earthing terminals with the earthing symbol b) Oil level gauge indicating oil
level at minimum, 30°C and maximum operating temperature; c) Air release
device (for non-sealed type transformers) d) Rating and terminal marking
plates; e) Silica gel breather f) Drain-cum-sampling valve (¾ ″ nominal size -
thread, IS 554) preferably steel with plug for three phase transformers; g)
Thermometer pocket with cap; h) Oil filling holes having (1¼ ″ nominal size
thread) with cover (for sealed type transformers without conservator); i)
Lifting lugs for the complete transformer as well as for core and winding
assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One
filter valve on the upper side of the tank (for transformers above 200 kVA); l)
Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection -
hole (for transformers above 200 kVA); n) HV side neutral grounding strip
(where one of the HV bushing terminal is connected to earth);
o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or
suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil
temperature indicator and winding temperature indicators for transformers
above 200 kVA with suitable tripping mechanism above permissible limit s)
Jacking pads (for transformer above 1600 kVA); t) Additional Neutral
separately brought out on bushing for earthing. u) Magnetic oil level gauge
24.9 (for transformer above 1600 kVA) with low oil level alarm contact; v) Non -
return valve (for conducting pressure test); w) Pressure relief device or
explosion vent x). Monogram Plate y) Inspection cover z). Detachable type
radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level
indicator, minimum level marking and drain plug for all transformers of
capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for
termination on HV/MV etc. for all transformers.
Total For Subhead-II Transformer 9,95,660.00 -
C Subhead-III DG Set
Supply, installation, Testing & Commissioning of 'Silent Type Diesel
Generating set as per CPCB IV + or better norms along with having Prime
Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power
factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor,
29.1 including testing at factory and site with fuel, load for test and other - -
necessary arrangements Complete as per CPWD specifications, should
have QR code which should contain drawing, test report OEM manual,Geo-
Tag of manufacturing location, rating plate as per relevant IS Code etc. and
consisting of the followings:
Signature of Tenderer
52 Signature of NBCC
(A) Diesel Engine:
Turbocharged Diesel engine 4 stroke water cooled, multi cylinder,
dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM
suitable for above output of alternator at 40 Degree C, 50% RH & at 1000
Meter MSL , capable of taking 10% over loading for one hour after 12 hours
continuous operation. The engine will be with Electronic governor, Dry type
Air filter with service indicator, first filling of engine fuel (after
lubricating Oil, Coolant and other consumables complete with all the
required accessories, the Electronic governor shall be as per ISO 8528.The
engine shall comply to the latest CPCB norms (CPCB IV + or better) and
Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per
CPWD specifications.
(B) Engine mounted Instrument Panel fitted with and having digital display
(i) Start-stop switch with key
(ii) Water temperature indication
(iii) Lubrication oil pressure indication
(iv) Lubrication oil temperature indication
(v) Battery charging indication and Voltage indication
(vi) RPM indication
(vii) Over speed indication
(viii) Low lubricantion Oil trip indication
(ix) Engine Running Hours indication
(C) Alternator:
Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3
phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50%
RH & at 1000 Meter MSL. The alternator shall be having Screen Protected
Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically
balanced rotor, capable of taking 10% over loading for one hour after 12
hours of continuous operation, self cooled,self-excited and self-regulated
through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for
tropical conditions and with class- H insulation.
(D) Base Frame & Foundation:
Both the engine and alternator shall be mounted on suitable base frame
made of MS channel with necessary reinforcement which shall be installed
on suitable cement concrete foundation and vibration isolation arrangement
as per recommendations of manufacturer.
Signature of Tenderer
53 Signature of NBCC
Daily service fuel tank of suitable liters capacity as per CPWD Specifications,
fabricated out of 3 mm thick M.S. sheet complete with all standard
accessories and fuel piping between fuel tank and diesel engine with MS
class 'C' pipes of suitable dia. Complete with valves, level indications &
accessories as required as per specifications.
(F) Exhaust System:
Dry exhaust manifold with hospital type exhaust silencer and catalytic
(G) Starting System:
12V/24V DC starting system comprising of starter motors: voltage
regulator and arrangement for initial excitation complete with suitable
numbers of batteries (180 AH capacity lead acid SMF type) as required as
per specifications. The battery shall be housed inside the acoustic enclosure
(H) Acoustic and weather proof enclosure with arrangement for fresh air
intake for cooling of the engine & alternator, extraction, discharging hot air in
to the atmosphere and the temperature rise inside the enclosure, noise level
outside enclosure. The acoustic enclosure should be suitable for cable
connection/connection through bus-trunking. Such arrangements on
acoustic enclosure should be water proof & dust-proof conforming to IP-65
protection. The enclosure shall be as per CPCB IV + or better norms etc. and
as per CPWD specifications.
Free standing floor mounted IP 42 automatic mains failure control panel
including auto by-pass, suitable for KVA as below for silent type DG set
complete with relays, timers, set of CTs for metering & protection and energy
analyser to indicate currents, phase and line voltages, frequency, power
factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase &
KW & provision for overload, short circuit, restricted earth fault, under
frequency, power (aluminum) and control (copper ) cabling of suitable size
upto 15 meter between AMF panel, LT Panel and DG Set including
connection interconnection etc. as required, all complete and inter locking
and communication/ Ethernet /RS485/SNMP port open protocol for BMS
integration including suitable software, the panel shall be of DG Set OEM
make etc. as per approved by Engineering in charge and including the
Signature of Tenderer
54 Signature of NBCC
1. Suitable numbers and appropriate capacity 4 pole motorised
electrically operated draw out with cradle type 3 position ACB/ MCCB
with electronic release for O/C & E/F and shunt trip.
2. Auto/Manual/Test/Off selector switch
3. Protection for under and over voltage phase reversal (2 nos Over
voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage
4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15
VA class-I for metering
5. Energy analyser unit to indicate current, Voltage( L-N & L-L), kW, kVA
(Phase & Total), Frequency, KWH, PF.
6. LED Indicating lamps for load on mains and load on set.
7. Fuse/ MCB for instruments.
8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter
and ammeter, selector switch for trickle, off and boost and current
9. Main supply failure monitor.
10. Supply failure timer.
11. Restoration timer
12. Control unit with three impulse automatic engine start/stop and failure
to start lockout.
13. Impulse counter with locking and reset facility.
14. ON/OFF/Control circuit switch with indicator
15. Audio/Video annunciation for
(i) High water temperature
(ii) Low lubricating oil pressure
(iii) Engine over speed
(iv) Engine fails to start
(v) Full load/maximum load warning
16. Protection for over/under Frequency, Loss of AC sensing, Over
Current, Unbalancing load with suitable number of relays and
17. Maintenance notification based on Engine Run Hour & due date.
18. Load Management through PLC to achieve auto opening and closing of
incomer breakers, bus coupler switching of essential panel ,
interlocking providing signal to AMF Panel for load status and AMF
shall give command to DG Set to auto start / auto stop depending upon
load status and requirement etc. and necessary hardware and
software required to perform the operation shall be provided by the
contractor including all control wiring.
Total For Subhead-III DG Set 12,49,613.00 -
D Subhead-IV Distribution Panel
Signature of Tenderer
55 Signature of NBCC
SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz
power distribution system. The panel shall be Indoor, free standing, floor
mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type
compartmentalised design fabricated out of 14 SWG CRCA sheet steel,
complete with colour coded, heat shrinkable PVC insulated, aluminium bus
bars and separate earth bus bar of adequate cross section through out the length
of the panel. The incoming and outgoing feeders shall be accommodated in a
fully segregated, modular multitier arrangement with adequate size and distinc -
cable alley, bus bar alley/chamber. The panel shall be complete with name
plate, earthing, numbering, danger plate etc. as per specifications and drawings
as required. The panel shall withstand the fault level of 50kA as per Single
Line Diagram. The Panel shall also be capable to communicate status like
ON/OFF/ Trip through Modbus/Ethernet for major component like ACB,
MCCB, MCB & Multifunation meters.
The Main LT Panel shall use all draw out type breakers suitable for 415 V
AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Panel shall have
Buscoupler switching, auto operation of incommer and bus coupler, auto start
of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and -
having following incomming and outgoing Air Circuit
Breakers,microprocessor release for overload, short circuit, instantaneous &
earthfault protection with Current & Voltage metering & LCD display.
Air Circuit Breaker with microprocessor release ge metering & LCD display ,
with ready to clsoe indicator, should have capability to communicate ON
/OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of
ACB (Icu=Ics=Icw=65 KA (1 sec). MCCB, with microprocessor release with
LSIG protection functionand should not derate upto 50 decree Centrigrate as
per testing guideline as per IEC 60947-2 and all the ACB upto 2500Amp -
ACB should have same frame size LCD display for fault trip history, haivng
current limiting feature, double break mechanism & capability to communicat
ON /OFF/ Trip Status on Modbus/Ethernet. (65 KA Ics)
1 Nos. 800 Amp FP ACB 25KA LSIG having S/C, E/F O/C protection, LCD
Display having specs as per attached annexture From 400KVA Transformer
R,Y,B Phase indication Lamp with control MCB -
On, Off, Trip Status Indication with control MCB
Inbuilt Zone Slelective Interlocking function
Multifunction Meter
1 Nos. 320 Amp FP MCCB 25KA LSIG having S/C, E/F O/C protection,
LCD Display having specs as per attached annexture From 160KVA DG Set
R,Y,B Phase indication Lamp with control MCB -
On, Off, Trip Status Indication with control MCB
Inbuilt Zone Slelective Interlocking function
Multifunction Meter
Signature of Tenderer
56 Signature of NBCC
1 Nos. 63 Amp FP MCCB 25KA LSIG having S/C, E/F O/C protection, LCD
Display having specs as per attached annexture From 20KWp On Grid Solar
R,Y,B Phase indication Lamp with control MCB -
On, Off, Trip Status Indication with control MCB
Inbuilt Zone Slelective Interlocking function
Multifunction Meter
1 Nos. 320 Amp FP ATS 25KA -
1 Nos. 1000 Amp FP busbars of aluminium alloy as per SLD. -
1 Nos. 400 Amp FP busbars of aluminium alloy as per SLD. -
1 Nos. 320 Amp TP MCCB 25 KA
On, Off, Trip Status Indication with control MCB
Multifunction Meter
APFC PANEL + SPARE
2 Nos. 400 Amp FP MCCB 25 KA
On, Off, Trip Status Indication with control MCB
Multifunction Meter
2 Nos. 200 Amp FP MCCB 25 KA
On, Off, Trip Status Indication with control MCB
Multifunction Meter
L+P PANEL + SPARE
2 Nos. 100 Amp FP MCCB 25 KA
On, Off, Trip Status Indication with control MCB
Multifunction Meter
STP PANEL + SPARE
5 Nos. 63 Amp FP MCB 10 KA
On, Off, Trip Status Indication with control MCB
Multifunction Meter
EX.LIGHT+PL+FF+SPARE
3 Nos. 32 Amp DP MCB 10 KA
On, Off, Trip Status Indication with control MCB
Multifunction Meter
Short Circuit Breaking capacity should not less than 10KA. -
RELAYS AS PER SLD - -
Signature of Tenderer
57 Signature of NBCC
SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz
power distribution system. The panel shall be Indoor, free standing, floor
mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type
compartmentalised design fabricated out of 14 SWG CRCA sheet steel,
complete with colour coded, heat shrinkable PVC insulated, aluminium bus
bars and separate earth bus bar of adequate cross section through out the length
of the panel. The incoming and outgoing feeders shall be accommodated in a
fully segregated, modular multitier arrangement with adequate size and distinc -
cable alley, bus bar alley/chamber. The panel shall be complete with name
plate, earthing, numbering, danger plate etc. as per specifications and drawings
as required. The panel shall withstand the fault level of 50kA as per Single
Line Diagram. The Panel shall also be capable to communicate status like
ON/OFF/ Trip through Modbus/Ethernet for major component like ACB,
MCCB, MCB & Multifunation meters.
The Main LT Panel shall use all draw out type breakers suitable for 415 V
AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Panel shall have
Buscoupler switching, auto operation of incommer and bus coupler, auto start
of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and -
having following incomming and outgoing Air Circuit
Breakers,microprocessor release for overload, short circuit, instantaneous &
earthfault protection with Current & Voltage metering & LCD display.
Air Circuit Breaker with microprocessor release ge metering & LCD display ,
with ready to clsoe indicator, should have capability to communicate ON
/OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of
ACB (Icu=Ics=Icw=65 KA (1 sec). MCCB, with microprocessor release with
LSIG protection functionand should not derate upto 50 decree Centrigrate as
per testing guideline as per IEC 60947-2 and all the ACB upto 2500Amp -
ACB should have same frame size LCD display for fault trip history, haivng
current limiting feature, double break mechanism & capability to communicat
ON /OFF/ Trip Status on Modbus/Ethernet. (65 KA Ics)
1 Nos. 200 Amp FP MCCB 16KA
R,Y,B Phase indication Lamp with control MCB
On, Off, Trip Status Indication with control MCB -
Inbuilt Zone Slelective Interlocking function
Multifunction Meter
1 Nos. 250 Amp FP busbars of aluminium alloy as per SLD. -
5 Nos. 63 Amp FP MCB 10 KA
5 Nos. 32 Amp FP MCB 10 KA
3 Nos. 63 Amp FP MCCB 10 KA
On, Off, Trip Status Indication with control MCB
Multifunction Meter
Signature of Tenderer
58 Signature of NBCC
2 Nos. 100 Amp FP MCCB 10 KA
On, Off, Trip Status Indication with control MCB
Multifunction Meter
Short Circuit Breaking capacity should not less than 10KA. -
RELAYS AS PER SLD - -
3 MR UPS OUTPUT PANEL 1.00 Set 93,500.00 93,500.00
SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz
power distribution system. The panel shall be Indoor, free standing, floor
mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type
compartmentalised design fabricated out of 14 SWG CRCA sheet steel,
complete with colour coded, heat shrinkable PVC insulated, aluminium bus
bars and separate earth bus bar of adequate cross section through out the length
of the panel. The incoming and outgoing feeders shall be accommodated in a
fully segregated, modular multitier arrangement with adequate size and distinc -
cable alley, bus bar alley/chamber. The panel shall be complete with name
plate, earthing, numbering, danger plate etc. as per specifications and drawings
as required. The panel shall withstand the fault level of 50kA as per Single
Line Diagram. The Panel shall also be capable to communicate status like
ON/OFF/ Trip through Modbus/Ethernet for major component like ACB,
MCCB, MCB & Multifunation meters.
The Main LT Panel shall use all draw out type breakers suitable for 415 V
AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Panel shall have
Buscoupler switching, auto operation of incommer and bus coupler, auto start
of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and -
having following incomming and outgoing Air Circuit
Breakers,microprocessor release for overload, short circuit, instantaneous &
earthfault protection with Current & Voltage metering & LCD display.
Air Circuit Breaker with microprocessor release ge metering & LCD display ,
with ready to clsoe indicator, should have capability to communicate ON
/OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of
ACB (Icu=Ics=Icw=65 KA (1 sec). MCCB, with microprocessor release with
LSIG protection functionand should not derate upto 50 decree Centrigrate as
per testing guideline as per IEC 60947-2 and all the ACB upto 2500Amp -
ACB should have same frame size LCD display for fault trip history, haivng
current limiting feature, double break mechanism & capability to communicat
ON /OFF/ Trip Status on Modbus/Ethernet. (65 KA Ics)
1 Nos. 100 Amp FP MCCB 16KA
R,Y,B Phase indication Lamp with control MCB
On, Off, Trip Status Indication with control MCB -
Inbuilt Zone Slelective Interlocking function
Multifunction Meter
1 Nos. 125 Amp FP busbars of aluminium alloy as per SLD. -
Signature of Tenderer
59 Signature of NBCC
3 Nos. 63 Amp FP MCB 10 KA
2 Nos. 32 Amp FP MCB 10 KA
2 Nos. 32 Amp DP MCB 10 KA
Short Circuit Breaking capacity should not less than 10KA. -
RELAYS AS PER SLD -
4 25.1 Automatic Power Factor Correction (APFC) System
Supply, Installation, testing and commissioning of Automatic Power Factor
Correction (APFC) panel, indoor type floor mounted free standing totally
enclosed, extendable, IP 42, of following capacity for 3 phase, 415 V + 10 %,
50 Hz AC System for Ambient temperature -5°C to +40°C, fabricated in
compartmentalised designed made of CRCA sheet steel of 2.0mm thick for
framework & covers, 3 mm thick for gland plate i/c cleaning & finishing
complete with 9 tank process for powder coated of approved
shade having front section (switch gear
and control accessories) and rear section capacitor
and reactor, front and rear access, having suitable
current carrying capacity, extensible TPN Aluminium
alloy bus bar of high conductivity, DMC/SMC bus bar -
supports, bottom base channel of MS Section,
fabrication shall be done in transportable section,
entire panel shall have common copper earth bar of
minimum size of 25mm x 5mm with 2 nos. earth
studs, the earth terminals provided on the body of
capacitor bank shall also be bonded to the main
capacitor panel earth bus with 2 nos. 8 SWG or 6
SWG GI earth wires/ equivalent size of copper
conductor cable, forced ventilation for maintaining
temperature rise not more than 5°C from ambient,
Signature of Tenderer
60 Signature of NBCC
interconnections, connections with 14% detuned
reactor and heavy duty 525 V ISI marked Impregnated
MPP(Metalized Polypropylene) Capacitor (IS 13340
Part -1 & 2) APFC Panel shall be in compliance with
IS :16636 & CPWD Specifications etc.
as per below details.
Suitable capacity MCCB Microprocessor base with
O/C, S/C, E/L release of TPN 50KA breaking capacity
(Ics=Icu), ON, OFF, Trip, R, Y, B - LED Indicating
Lamp set along with required Instruments and
accessories with extended rotary handle and door
interlocking arrangement. Current rating of theIncomer in ampere shall be
APFC Panel rating in -
KVAR x 1.4 x 1.5 or Nearest higher standards rating.
(B) Instruments & Indications
i) 3-Phase current sensing APFC microprocessor
relay/controller , advance 8/12 stages (8 stages for
capacity below 100 KVAR and 12 stages 100 KVAR &
above) with Communication Ethernet/RS485/SNMP
port open protocol for BMS integration as per
approved by Engineering in charge and having
display of Phase wise V, A, PF, Cos-Phi, Kw, KVA,
KVAR, THD-V , THD-I, harmonics up to 31 level. 3
nos of dual core CT's accuracy class 1, 15VA at
incomer of PCC Panel for APFC relay.
Signature of Tenderer
61 Signature of NBCC
ii) Auto Manual Selector switch, auxiliary contactors
with timer for delay in manual mode.
iii) Digital Multi function meter with LED Display for V,
A, PF, KW, KVA, KVAR, THD-V & I, Frequency.
iv) Suitable rating control transformer shall be provided
for control and indication circuit.
v) All components like control transformer, meter, relay
and indicating lamp shall be protected by using
suitable rating individual MCB's.
vi) Wiring of the control circuit shall be done by using
2.5 sq mm, FRLS/HFFR 1100 V grade, PVC insulated
multi stranded copper control wire.
(C) Bus Bars 1.3 Amp per Sq.mm,TPN, Electrolytic
grade Aluminium bus bar of capacity 1.25 times of -
incomer rating as per CPWD specification.
(D) Outgoings (APFC Section) Selection of the
capacitors combinations shall be for continuous
rating and each capacitor bank shall have suitable
capacity Heavy Duty ISI Marked Capacitor, capacitor
duty contactor,the capacitor shall be mounted on
channel with base of perforated M S Powder coated
sheet, connections inter connections etc. and other
features as per CPWD Specifications and relevant IS
Code having following:
(i) Capacitor bank ratings & stages shall be as per the
technical specifications sheet of NIT.
(ii) Capacitor will be MPP self healing type with
discharge resistor, pressure release mechanism.
(iii) Since Capacitor Voltage is 525 Volts, thus higher
KVAR has to be considered to get rated output at 415
Volts.(iv) 14% Detuned Reactor of class H insulation &
150% linearity in series with Capacitor.
(Note: Technical specifications sheet for selection of
the capacitors combinations shall be provided by the
NIT Approving Authority with due consideration of
number of capacitors i.e. 1 KVAR, 2 KVAR, 3 KVAR, 5
KVAR, 10 KVAR.....for smooth correction).
Total For Subhead-IV Distribution Panel 3,20,033.00 5,97,500.00
E Subhead-V L.T Cable Work
Supply and laying of aluminium conductor PVC insulated armoured serve
sheathed cables 1100 Volts grade on cable tray as directed by engineer
incharge complete in all respect including The armouring of the cable shall be
properly connected with the earth conductor by clamps etc.
Signature of Tenderer
62 Signature of NBCC
Supply ofPower/Control Copper Cables,Solid Copper conductor,XLPE
Insulated,cores laid up, PVC tape innersheathed,Unarmoured/Armour
2 MR (Glavanised wire for cables up to 14x1.5 sqmm, 9x2.5 sqmm,2x16 sqmm, - -
3x10 sqmm,4x10sqmm balance all galvanised steel strip),extruded PVC Type
ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988
Supplying and making end termination with brass compression gland and
aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE
3 aluminium conductor cable of 1.1 KV grade as required. - -
Laying of one number PVC insulated and PVC sheathed / XLPE
4 10.5 power cable of 1.1 KV grade of following size in the existing -
RCC/ HUME/ METAL pipe as required.
b 10.5.2 Above 35 sq. mm and upto 95 sq. mm 30.00 Meter 72.00 2,160.00 -
d 10.5.4 Above 185 sq. mm and upto 400 sq. mm 150.00 Meter 170.00 25,500.00 -
Laying and fixing of one number PVC insulated and PVC
5 10.8 sheathed / XLPE power cable of 1.1 KV grade of following size -
on cable tray as required.
a 10.8.1 Upto 35 sq. mm (clamped with 1mm thick saddle) 100.00 Meter 53.00 5,300.00 -
b 10.8.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 70.00 Meter 109.00 7,630.00 -
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat
d 10.8.4 Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clam 110.00 Meter 226.00 24,860.00 -
Providing, laying and fixing following dia RCC pipe NP2 class
(light duty) in ground complete with RCC collars, jointing with
cement mortar 1:2 (1 cement : 2 fine sand) including trenching
(75 cm deep) and refilling etc as required. 300mm Dia
Signature of Tenderer
63 Signature of NBCC
Supplying and laying of following size DWC HDPE pipe ISI marked along
with all accessories like socket, bend, couplers etc.
conforming to IS 14930, Part II complete with fitting and cutting,
jointing etc. in the existing trench, complete as required
Total For Subhead-V L.T Cable Work 2,01,582.00 7,06,001.51
F Subhead-VI External Lighting Work
EXTERNAL LIGHT FEEDER PILLAR -
Supply installing testing & commissioning of out door type IP66 with
additional canopy street light feeder pillar (Distribution Panel)
1 MR compartmentalised design, dust tight & vermin proof made out of 14 gauge 1.00 Each 90,000.00 90,000.00
M.S. sheet, stove powder coated complete as required with following
incomming & outgoing as per detail below.
63 Amp. 10 KA FP MCCB 1 No. -
Suitable digital contractor and timer for down & dusk -
100 Amp. TPN Alu. Bus bar -
32 Amp. 10KA DP MCB 9 No. -
40 Amp. 10KA FP MCB 2 No. -
Supply and laying of aluminium conductor PVC insulated armoured serve
sheathed cables 1100 Volts grade in existing RCC / Hume / metal pipe as
2 MR directed by the Engineer-Incharge, complete in all respect. The armouring of - -
the cable shall be properly connected with the earth conductor by clamps etc.
Supplying and making end termination with brass compression gland and
aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE
3 aluminium conductor cable of 1.1 KV grade as required. - -
Supplying and laying of following size DWC HDPE pipe ISI marked along
with all accessories like socket, bend, couplers etc.
conforming to IS 14930, Part II complete with fitting and cutting,
jointing etc. in the existing trench, complete as required
Signature of Tenderer
64 Signature of NBCC
Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for
earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre
from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in G.I.
Pipe up to appron (and from appron to switch board the cost of G.I. wire and
5 5.2 pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover 2.00 each 7,658.00 15,316.00 -
masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at
least 150mm thick alround etc. as per directions of Engineer-in-charge
complete in all respects as per drawing.
Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for
earthing with its top at least 3 metres below ground level complete with 20mm
dia G.I. pipe and funnel for watering and one earthing lead of two no. 8 to 10
SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to
6 switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. 2.00 each 8,351.00 16,702.00 - -
frame with hinged cover masonry housing alternate layers of charcoal/coke an
salt at least 150mm thick alround etc. as per directions of Engineer-in-charge
complete in all respect.
Supply and laying of 25 mm X 3mm G.I. strip from earth electrode directly in
the ground as required complete in all respect.
Supply and fixing of 1 no. 8SWG GI wire in 15mm dia GI pipe for earthing,
laid in ground or in wall duly concealed including the cost of cement, sand,
labour, T&P other material required for proper completion of the work as
directed at site.
Supply & fixing of 3 mtr pu painted decorative pole alongwith foundation
work etc as required.
Supplying, Installation, Testing & Commissioning of LED Post Top Light
Fixture with powder coated pressure die cast aluminium housing and UV
stabilized polycarbonate diffuser, complete with high efficiency constant
current driver, suitable for outdoor applications. Driver efficiency>85%, input
voltage 140–270 Volt AC, frequency 50/60 Hz, operating temperature range -
5°C to +50°C, internal surge protection of 5 kV (L, N, E) as per IEC 61000-4-
5, THD <10% as per IEC 61000-3-2, Power Factor ≥0.95, IP66 protection,
IK08/IK10 impact resistance, CRI >70, under voltage and over voltage
protection, EMI/EMC as per CISPR-15, symmetric light distribution (IES
Type V) suitable for parks, pathways, landscaped areas and pedestrian zones.
Fixture suitable for top entry mounting on 76 mm O.D. pole (or up to 76 mm
spigot) complete with all mounting accessories.
MR Luminaire shall have a minimum life of 50,000 burning hours with L70 lumen -
maintenance as per LM-80 extrapolated through IES TM-21. Colour
Temperature 3000K / 4000K / 5700K / 6500K (as approved by Engineer-in-
Charge), SDCM <5, maximum power consumption shall not exceed the
specified rating. Fixture shall conform to relevant BIS standards complete in
all respects including external connections with 1.5 sq.mm FRLS/HFFR PVC
insulated copper conductor single core cable, earthing, glands, ferrules and all
accessories as required.
LM-79 & LM-80 Test Reports and all testing certificates required as per BIS
shall be submitted. Thermal management shall be through an aluminium heat
sink such that the LED junction temperature shall not exceed 90°C. The fixtur
shall be supplied with a minimum 5-year OEM warranty.
Signature of Tenderer
65 Signature of NBCC
Total For Subhead-VI External Lighting Work 59,212.00 4,83,079.52
G Subhead-VII Earthing Work
Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for
earthing with its top at least 3 metres below ground level complete with 20mm
dia G.I. pipe and funnel for watering and one earthing lead of two no. 8 to 10
SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to
1 switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. 6.00 each 8,351.00 50,106.00 - -
frame with hinged cover masonry housing alternate layers of charcoal/coke an
salt at least 150mm thick alround etc. as per directions of Engineer-in-charge
complete in all respect.
Supply and burying of 600mm x 600mm x 3mm copper plate vertically for
earthing with its top at least 3 metres below ground level complete with 20mm
dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG
copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch
2 board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. 4.00 each 15,004.00 60,016.00 - -
frame with hinged cover masonry housing alternate layers of charcoal/coke an
salt at least 150mm thick alround etc. complete in all respect.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground
as strip earth electrode, including connection/ terminating with nut, bolt,
spring, washer etc. as required. (Jointing shall be done by overlapping and with
2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as
strip earth electrode, including connection/ terminating with G.I. nut, bolt,
spring, washer etc. as required. (Jointing shall be done by overlapping and
with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from
5 5.10 earth electrode including connection with brass nut, bolt, spring, washer 40.00 Meter 1,638.00 65,520.00 - -
excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from
6 5.11 earth electrode including connection with G.I. nut, bolt, spring, washer 60.00 Meter 755.00 45,300.00 - -
excavation and re-filling etc. as required.
Total For Subhead-VII Earthing Work 3,07,022.00 -
H Subhead-VIII Panel Protection System
2kg capacity seamless Alluminium cylinder Paso approved stored pressure
type clean agent fire extinguisher alongwith all necessary fitting filled with
clean agent FK-5-1-12 complete having operating pressure between 15 bar etc.
as required UL & FM listed gas.
SITC of Pneumatic Heat detection tube red color made by special modified polyamide
(PA), UL and LPCB standard, having burst temperature 100°C to 120°C, inner
diameter 4 mm, outer diameter 6 mm, pressurized with nitrogen at 15 bar pressure for
automatic detection and suppression system
Signature of Tenderer
66 Signature of NBCC
SITC of End of line adapter along with pressure gauge working pressure 25 bar. UL
SITC of End of Line Plug for automatic fire suppression System used for fitting at
5 MR tube end to terminate the point. Fitting made by brass nickel plated material. UL 4 Each 4,560.00 18,240.00
6 MR SITC of Pressure Switch at 15 bars. UL approved. 4 Each 7,990.00 31,960.00
SITC of T connection suitable for 4 / 6 mm. diameter pressurized tubes, brass nickel
plated material with maximum working pressure 25 bar. UL approved
SITC of Master Control Unit micro processor based 4 zone inbuilt GSM dialer audio
visual alarm control panel, 2NO/NC potential free relay contacts discharge LED
indicator, battery LED indicator, system status indicator and AC power ON LED
indicator with inbuilt battery backup 24h
Total For Subhead-VIII Clean Agent Suppression System - 5,15,950.00
I Subhead-IX Cable Tray Work
Supplying and installaton following size of perforated painted with powder
coating M.S. cable trays with perforation not more than 17.5%, in convenient
46 sections, joined with connectors, suspended from the ceiling with two numbers - - -
MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting
suspenders, fastener etc as required
a 4.1.1 100 mm width X 50 mm depth X 1.6 mm thickness 20.00 Meter 623.00 12,460.00 - -
c 4.1.10 450 mm width X 62.5 mm depth X 2 mm thickness 20.00 Meter 1,348.00 26,960.00 - -
Total For Subhead-IX Cable Tray Work 39,420.00 -
J Subhead-X On Grid Solar Power Backup System
On Grid Solar System Work
Signature of Tenderer
67 Signature of NBCC
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic
Power Plant conformington MNRE specifications as amended, consisting of
Mono Crystalline silicon solar cells, netmetering facility, necessary protection
earthing, mounted on Aluminium/GI structure of suitable strength with
following components complete as required:-a)Solar Photovoltaic Module of
1 17.1 capacity 330Wp or above, manufactured in India, conforming to 20.00 KWp 54,280.00 10,85,600.00 - -
IS14286/IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar
Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV
modules used in solar power plants/systems must be warranted for their output
peak watt capacity, which should not be less than 90% at the end of 10years
and 80% at the end of 25 years
b)Power Conditioning Unit (PCU) of 350-800VDC Input voltage range and
400VAC, three phase, 4wire, 50Hz+/-2.5Hz, out put voltage suitable to
generate AC Power with efficiency not less than 97%, total harmonic distortio
less than 3% and suitable for ambient temperature from 0to50degree C. The
PCU shall adjust the voltage and frequency level to suit the Grid Voltage
Frequency.c) Data Monitoring System complete with accessories.
d) Fixing of Array junction box & Main junction box with IP65 protection and
termination arrangement for in coming and outgoing cable alongwith glands,
lugs and other accessories etc. as required.
e) Lightning and surge voltage
protection.f)Connections&Interconnectionsbysupplying&fixingrequiredsizeXL
PEinsulatedcopperconductor1.1kVgradearmouredpowerandcontrolcablesbetwe
ensolarmodules,mainpowercabletogridsupplyPCUunitalongwithsupplying&fixi
ngofnecessarychannel/conduitlugsandotheraccessoriesetc.asrequired.
Subhead-X On Grid Solar Power Backup System 10,85,600.00 -
Grand Total (DSR+Market Based Item) 79,47,647.51
Grand Total (DSR+Market Based Item) 79,47,647.51
Grand Total (DSR+Market Based Item) In Lacs 79.48
Grand Total (DSR+Market Based Item) In Lacs 79.48
Signature of Tenderer
68 Signature of NBCC
Detailed Estimate Based On DSR-2025 With Cost Index & Market Rate
ICAI BHAWAN- GORAKHPUR SITUATED AT PLOT NO-B-11, TARAMANDAL, NEAR CIRCUIT HOUSE, OPP. RAMGARHTAL LAKE, GORAKHPUR (U.P.)
Name Of Work -Internal Electrical
Rate as per D.S.R. 2025 Rate as per Market Rate
Sr.No. Sch.No. Particulars Qty Unit Amount Rate Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell
point with 1.5 sq.mm FRLS PVC insulated copper conductor
single core cable in surface / recessed medium class PVC
1 1.10.3 conduit, with modular switch, modular plate, suitable GI box 185.00 Nos. 1,704.00 3,15,240.00
and earthing the point with 1.5 sq.mm FRLS PVC insulated
copper conductor single core cable etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface /
2 1.11 recessed medium class PVC conduit, 2 way modular switch, 4.00 Nos. 1,803.00 7,212.00
modular plate, suitable GI box and earthing the point with 1.5
sq.mm FRLS PVC insulated copper conductor single core cable
etc. as required. -
Wiring for circuit/ submain wiring alongwith earth wire with the
following sizes of FRLS PVC insulated copper conductor, single core
cable in surface/ recessed medium class PVC conduit as required.
Supplying and drawing following pair 0.5 mm dia FRLS PVC
insulated annealed copper conductor, unarmored telephone
cable in the existing surface/ recessed steel/ PVC conduit as
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid
copper conductor PE insulated, shielded with fine tinned copper braid
and protected with PVC sheath in the existing surface/ recessed steel/
PVC conduit as required. -
Signature of Tenderer 69 Signature of NBCC
Supplying and fixing of following sizes of medium class PVC
conduit along with accessories in surface/recess including
cutting the wall and making good the same in case of recessed
conduit as required. -
Supplying and fixing following modular switch/ socket on the
7 1.24 existing modular plate & switch box including connections but -
excluding modular plate etc. as required. -
a 1.24.6 Telephone socket outlet 8.00 Each 168.00 1,344.00 -
b 1.24.7 TV socket outlet 5.00 Each 168.00 840.00 -
c RA-1 RJ45 socket cat 6 with shutter 78.00 Each - 421.58 32,883.09
d MR HDMI Socket 7.00 Each - 650.00 4,550.00
Supplying and fixing following size/ modules, GI box alongwith
9 1.27 modular base & cover plate for modular switches in recess etc. -
as required. -
Supplying and fixing suitable size GI box with modular plate and cover
in front on surface or in recess, including providing and fixing 3 pin 5/6
A modular socket outlet and 5/6 A modular switch, connections etc. as
Supplying and fixing suitable size GI box with modular plate and cover
in front on surface or in recess, including providing and fixing 6 pin 5/6
& 15/16 A modular socket outlet and 15/16 A modular switch,
connections etc. as required. -
Installation ,Testing, Commissioning of wall bracket /ceiling
fittings of all sizes and shapes containing upto two GLS/CFL/LED
lamps per fitting, complete with all accessories including connections
etc. as required. -
Supplying and fixing call bell/ buzzer suitable for single phase,
230 V, complete as required. -
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the
existing surface/ recessed Steel/ PVC conduit as required. -
Wiring for group controlled (looped) light point/fan
point/exhaust fan point/ call bell point ( without independent
15 1.55 switch etc.) with 1.5 sq. mm FRLS PVC insulated copper -
conductor single core cable in surface/ recessed PVC conduit,
and earthing the point with 1.5 sq. mm FRLS PVC insulated
copper conductor single core cable etc. as required. -
Supplying and fixing suitable size GI box with modular plate and cover
in front on surface or in recess, including providng and fixing 2 nos. 3
16 1.56 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, 91.00 Each 757.00 68,887.00
connections etc. as required. (For light plugs to be used in non
residential buildings). -
Signature of Tenderer 70 Signature of NBCC
Supplying & fixing suitable size GI box wih modular plate and
cover in front on surface or in recess including providing and
fixing 25 A modular socket outlet and 25 A modular SP MCB, "C"
curve including connections, painting etc. as required. -
Supplying and fixing following way, single pole and neutral,
sheet steel, MCB distribution board, 240 V, on surface/ recess,
18 2.3 complete with tinned copper bus bar, neutral bus bar, earth -
bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCB/RCCB/Isolator) -
Supplying and fixing following way, horizontal type three pole
and neutral, sheet steel, MCB distribution board, 415 V, on
20 2.4 surface/ recess, complete with tinned copper bus bar, neutral -
bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without
MCB/RCCB/Isolator) -
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve,
miniature circuit breaker suitable for inductive load of following poles
in the existing MCB DB complete with
connections, testing and commissioning etc. as required. -
c 2.10.5 Three Phase & Neutral 6.00 Each 1,301.00 7,806.00 -
Supplying and fixing 63Amp, four pole, (three phase
and neutral), 415 volts, residual current circuit breaker (RCCB),
23 RA-3 having a sensitivity current 300 mA in the existing MCB DB 2.00 Each - 4,116.94
complete with connections, testing and commissioning etc. as
required. 8,233.87
Supplying and fixing 40/63A rating, 415 V, 10 kA, "C" curve,
miniature circuit breaker suitable for inductive load of Four poles in
25 RA-4 the existing MCB DB complete with connections, testing and 5.00 Each - 1,925.19
commissioning etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick
including accessories, and providing masonry enclosure with
27 5.4 cover plate having locking arrangement and watering pipe of 8.00 Each 8,531.00 68,248.00
2.7 metre long etc. with charcoal/ coke and salt as required. -
Signature of Tenderer 71 Signature of NBCC
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre
below ground as strip earth electrode, including connection/
29 5.9 terminating with G.I. nut, bolt, spring, washer etc. as required. 40.00 Meter 160.00 6,400.00
(Jointing shall be done by overlapping and with 2 sets of G.I. nut
bolt & spring washer spaced at 50mm) -
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in
recess for connections etc. as required. -
Providing and fixing 6 SWG dia G.I. wire on surface or in recess
34 5.18 for loop earthing along with existing surface/ recessed conduit/ 300.00 Meter 50.00 15,000.00
submain wiring/ cable as required. -
LED Down lighter (SMD Type) (System lumen efficacy
≥120<135lm/Watt)
Supplying, installation, Testing & Commissioning of LED
Recessed/surface Down lighter (Round/ square/ Rectangular) SMD
type of following body material with PMMA and prismatic diffuser and
construction as per IS : 10322 with driver as per the requirement with
Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency
50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal
35 surge protection of 2.5 KV with Short & Open circuit protection ,THD -
< 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified GlareRating) <19,
Flicker free (flicker should be below 5%), life time (LED, Driver &
electrical circuitry), lifetime of minimum 50000 Burning Hours with
70%of initial Lumen maintained till life ends, CCT3000°K / 4000°K /
5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color
Matching) <3, Maximum power consumption should not more than the
specified rating and Fixture shall be of relevant BIS standard.
Manufactures Word Mark/ Name Engraved/ Embossing/ Screen
printing on housing Complete in all respect i/c external connections
PVC insulated copper conductor single core cable and earthing etc. as
required with Minimum 5 year OEM warranty. System lumen efficacy
≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing
required for LED fixtures as per BIS shall be submitted.. Shape size -
andCCT shall be as approved by Engineer-inCharge as per
requirement. (Thermal management: heat sink of aluminium housing
such that LED junction temperature shall not rise above 90°C). Powder
coated die cast /Extruded aluminium Body including trim
Signature of Tenderer 72 Signature of NBCC
LED Down lighter (SMD Type) (System lumen efficacy
≥120<135lm/Watt)
Supplying, installation, Testing & Commissioning of LED
Recessed/surface Down lighter (Round/ square/ Rectangular) SMD
type of following body material with PMMA and prismatic diffuser and
construction as per IS : 10322 with driver as per the requirement with
36 Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency -
50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal
surge protection of 2.5 KV with Short & Open circuit protection ,THD
< 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified GlareRating) <19,
Flicker free (flicker should be below 5%), life time (LED, Driver &
electrical circuitry), lifetime of minimum 50000 Burning Hours with
(As per iti l L Bin), SDCM(Standard
i t i d till lif Deviation
Color Matching) /
Maximum power consumption should not more than the specified
rating and Fixture shall be of relevant BIS standard. Manufactures
Word Mark/ Name Engraved/ Embossing/ Screen printing on housing
Complete in all respect i/c external connections with 1.5 sq mm
FRLS/HFFR, PVC insulated copper conductor single core cable and
earthing etc. as required with Minimum 5 year OEM warranty. System -
lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report
and all testing required for LED fixtures as per BIS shall be submitted..
Shape size andCCT shall be as approved by Engineer-
in_x005fCharge as per requirement. (Thermal management: heat
sink of aluminium housing such that LED junction temperature shall
not rise above 90°C). Powder coated die cast /Extruded aluminium
Signature of Tenderer 73 Signature of NBCC
LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt)
Supplying, installation, Testing & Commissioning of Panel light 2x2
ft., of following body material and construction as per IS : 10322 with
driver as per the requirement with Driver efficiency >85%, Operating
voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5
0C to 40 0C, internal surge protection of 2.5 KV with Short & Open
circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR
(Unified Glare Rating) < 19, Flicker free, (flicker should be below 5
%), life time (LED, Driver & electrical circuitry), of minimum 50000
Burning Hours with , 70% of initial Lumen maintained till life ends
,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),
37 SDCM(Standard Deviation Colour Matching) <3, Maximum power -
consumption should not more than the specified rating and Fixture
shall be of relevant BIS standard. Manufactures Word Mark/ Name
Engraved/ Embossing/ Screen printing on housing. complete in all
respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC
insulated copper conductor single core cable and earthing etc. as
required with Minimum 5 year OEM warranty. System lumen efficacy
>135 lm/Watt output . LM79 & LM80 Test report and all testing
required for LED fixtures as per BIS shall be submitted. Shape size and
CCT shall be as approved by Engineer-in_x005fCharge as per
requirement. (Thermal management: heat sink of aluminium housing
such that LED junction temperature shall not rise above 90°C). Powder
SITC of 12W Extruded aluminium batten available in 2ft run length
38 RA-5 with multiple lumen packages and suitable for surface, wall & conduit 18.00 Each - 430.34
ounting (with accessories). 7,746.04
Signature of Tenderer 74 Signature of NBCC
LED Batten light (System lumen efficacy >135 lm/Watt)
Supplying, installation, Testing & Commissioning of LED surface
mounted Batten light of following body material and construction as
per IS : 10322 with driver (Replaceable) as per the requirement with
Driver efficiency >85% ,Operating voltage AC 140-270 Volt, frequency
50/60 hz, Operating temp range -5 0C to 40 0C, internal surge
protection of 2.5 KVwith Short & Open circuit protection ,THD < 10%
, P.F.≥0.95, IP20, CRI >80, Flicker free (flicker shouldbe below 5 %),
life time (LED, Driver & electrical circuitry), of minimum 50000
Burning Hours with 70% of initial Lumen maintained till life ends,
CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),
39 SDCM(Standard Deviation Color Matching) <3, Maximum power -
consumption should not more than the specified rating and Fixture
shall be of relevant BIS standard. Manufactures Word Mark/ Name
Engraved/ Embossing/ Screen printing on housing complete in all
respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC
insulated copper conductor single core cable and earthing etc. as
required with Minimum 5 year OEM warranty. System lumen efficacy
>135 lm/Watt output . LM79 & LM80 Test report and all testing
required for LED fixtures as per BIS shall be submitted.. Shape size
and CCT shall be as approved by Engineer-in-Charge as per
requirement. (Thermal management: heat sink of aluminium housing
such that LED junction temperature shall not rise above 90°C). Powder
Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire
having pressure diecast housing with driver set confirming to IP 65 and above
Protection, IK08, High purity / transmisivity UV stablized Non yellowish
41 MR diffuser/ Reflector for uniform light distribution, ditachable driver set, suitable 8.00 Each -
for 24hrs continuous operation complete in all respect.
1200 system lumen, >120lm/W, PF>0.95, CRI>70, >300V, over voltage
protection 4KV internal surge protection with 5 year warrenty CAT-AAA
Supply and fixing hexagonal Round G.P.fan box approved make made
up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight
DSR Civil holes for pipe entry of the box. Holes should be semi-shuttered type
2023 10.18 with 0.5 mm G.P. Sheet made upper & lower cover duly screwed.
Fixing with wiring conduit laid in the R.C.C. roof before concreting
alongwith supply of all material, labour, T&P etc. required for proper
completion of the work -
Supply Installation Testing and Commissioning of 400mm sweep
46 RA-2 1500RPM energy efficient BLDC fan with double ball bearing for 7.00 Each - 5,348.85
longer life. 37,441.94
Lightning Arrestor Work - -
Signature of Tenderer 75 Signature of NBCC
Lightning Arrestor: Supply, installation, testing and commissioning of
External Lightning wide area protection system based on Eaarly
Streamer Emission (ESE) technology. Device shall emit
electromagnetic impulse in the form of a streamer into the air
47 MR microseconds earlier than naturally formed streamers. Device confirmg 1.00 Each - 1,52,800.00
to NFC 17-102 and UNE 21186 Standards. Appropriate non
penetrating mounting arrangement. The device shall be mounted at
suitable clear to the highest point on the roof top. (Model selected shall
give coverage of 79 M radius @ min 5M height from terrace) 1,52,800.00
Down conductor:Supply, installation, testing and commissioning of 70
48 MR Sqmm twisted 19-Strand, bare Cu cable on surface/wall / as per site 50.00 Metre - 2,127.90
requirement and complete in all respect. 1,06,395.00
Lightning Counter :Supply and installation of counting the number of
lightning strikes without any power supply. 9,000.00
Earthing with copper earth plate 600 mm X 600 mm X 3 mm
thick including accessories, and providing masonry enclosure
with cover plate having locking arrangement and watering pipe
of 2.7 metre long etc. with charcoal/ coke and salt as required. -
Test Link :Supply and installation of test link in weather proof IP 65
Supply, installation, testing and commisioning of 2 x 25W LED
Aviation abstruction light medium bay type 62, complete with lamp,
lamp holder, Condenser necessary connecting wire, 1 X 25 AV with all
necessary hardware, accessories as required for complete installation.
Rate shall include the cost of necessary steel structures , fixing
arrangements in this item. Refer drawing. 10,406.00
Online UPS- Input supply: Three Phase, Output supply: Three
Supplying, installation, Testing & Commissioning of of following
capacity at full load (Unity Power Factor) at operating temperature 0 to
Relative humidity 0 to 95%, Online double conversion true sine wave
Uninterrupted hot swappable (allow for the replacement or addition of
battery modules without shutting down the entire system) modular
Supply (UPS) system with N+1 modules (N denotes total number of
moduels requird for rated capacity). The UPS shall include a Rectifier,
inverter, battery bank suitable for 30 minutes back up (Battery VAH
capacity shall not be less than 1600 VAH per KVA of UPS rating per
Hour backup time) on full load (Battery shall be VRLA, SMF in ABS
Container) and Static Bypass switch alongwith provision for manual
bypass, suitable isolation transformer for additional protection against
lf l UPS h ll h i b il
Signature of Tenderer 76 Signature of NBCC
phase sequence correction. The UPS systems offered are to be of the
technology with Digital Control Microprocessor based for reliable
operation using Insulated Gate Bipolar Transistor (IGBT)'s both for the
rectifier & inverter (3 Level) with PWM (Pulse Width Modulation).
The quality of design, manufacturing and inspection process should -
confirm to the relevant International standards such as IEC/EN/VDE.
The operating efficiency of the UPS systems shall be >96% while
operating on battery mode and delivering quality power to the 100%
non-linear loads. Current total harmonic effect(ITHD) on the input grid
shall be < 5% at 50 %load (The required LC (
inductor (L) and a capacitor (C)) filters shall be included in UPS cost),
extreme power factor kit to be included to limit the input power factor
(PF) to 0.99 and output power factor shall be unity (i.e. kw rating of
the UPS shall be kva rating x 1 ), however UPS shall be suitable to
take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be
suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5
Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload
capacity of 120% for 10 mins, Sine wave output. Non condensing, -
noise level less than 60db at 1 meter distance, protections: Input Under
voltage over voltage, abnormal out voltage, battery over charging,
output over current, short circuit protection, battery deep discharge
protection, 10KV surge. UPS must comply with low voltage
electromagnetic compatibility (EMC) achieved as per EN 6204,
EN6204 Part I and Part 2, it shall be a Voltage and Frequency
Independent (VFI)-type UPS. Communication RS232/RS485/SNMP
integration, t hardware
all l f BMS& software for iOT Communication as per
approved by Engineering in charge. Required battery racks and
interconnecting copper conductor cables of suitable size and connectors
and all required accoseries are inclusive of the cost). This system must
provide a means for logging and alarming of all monitored points plus
email notification. Forced air-cooling with integral inbuilt fans with
redundancy (if one fan fail UPS should be able to handle at least 80% -
of the load, Noise Level 65 DB at 1 meter distance. The system shall
be in compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD
Specification. Display Panel (minimum) (In-build 5 inch or more LC
Display / LED ) to display : a) Input: Voltage, current, Frequency. b)
Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current.
Signature of Tenderer 77 Signature of NBCC
d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage.
f)Temperature: STS, Inverter, PFC. g) Event Logging & Statistical
LCD/LED): UPS should capture and display up to 3000 events like:
temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-
26.2 Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) -
Statistical Data: No. of power failures / Transfers to Bypass / Total
Running time, etc. i) Mains Mode of Operation /Battery Mode of
Operation / Bypass feeding the load /UPS Fault /Battery charging and
discharging, overload, battery voltage and battery capacity. j) Audible
Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault,
Shutdown, Input Over, Under Voltage, Output Over, Under Voltage,
Battery Over, Under Voltage, Over Load and short circuit, Over
a 26.2.3 30KVA (Each Power module shall be < 10 KVA) 1.00 Set 5,05,748.00 5,05,748.00 -
Grand Total (DSR+MARKET BASED ITEM) 51,69,021.18
Grand Total (DSR+MARKET BASED ITEM) 51,69,021.18
Grand Total (DSR+MARKET BASED ITEM) In Lac 51.69
Grand Total (DSR+MARKET BASED ITEM) In Lac 51.69
Signature of Tenderer 78 Signature of NBCC
Detailed Estimate Based On DSR-2025 With Cost Index & Market Rate
ICAI BHAWAN- GORAKHPUR SITUATED AT PLOT NO-B-11, TARAMANDAL, NEAR CIRCUIT HOUSE, OPP. RAMGARHTAL LAKE,
GORAKHPUR (U.P.)
Name Of Work - Fire Detection Alarm & PA System Work
Rate as per D.S.R. 2025 MARKET BASED
Sr.No. Sch.No. Particulars Qty Unit Amount Rate Amount
Fire Alarm System :
Supplying, installation, testing and commissioning of micro
processor based intelligent addressable main fire alarm panel,
central processing unit with the following loop modules and
capable of supporting not less than 240 devices (including
detectors) and minimum 120 detectors per loop and loop
length up to 2 km, network communication card, minimum
320 character graphics/ LCD display with touch screen or
other keypad and minimum 4000 events history log in the non
1 28.2.1 volatile memory (EPROM), power supply unit (230 ± 5% V,
50 hz), 48 hrs back-up with 24 volt sealed maintenance free
batteries with automatic charger. The panel shall have facility
to connect printer to printout log and facility to have seamless
integration with analog/digital voice evacuation system (which
is part of the schedule of work under SH: PA System) and
shall be complete with all accessories . The panel shall be
compatible for IBMS system with open protocol BACnet/
Modbus over IP complete as per specifications.
Supplying, installation, testing & commissioning of
2 28.2.4 intelligent analog addressable photothermal (Smoke) detector 48 NOS 3,004.00 1,44,192.00 -
complete with mounting base complete as required.
Supplying, installation, testing & commissioning of response
3 28.2.5 indicator on surface/recessed MS Box having two LED, 40 NOS 306.00 12,240.00 -
metallic cover complete with all connections etc as required.
Supplying, installation, testing & commissioning of fault
isolator complete with base as required.
Signature of Tenderer 79 Signature of NBCC
Supplying, installation, testing & commissioning of intelligent
5 28.2.9 addressable thermal detector with rate of rise cum fixed 20 NOS 2,866.00 57,320.00 -
tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of
addressable fire control module complete as required.
Supplying, installation, testing & commissioning of
addressable phone control module complete as required.
Supplying, installation, testing & commissioning of
addressable manual call point complete as required.
Supplying, installation, testing & commissioning of
addressable horn cum strobe complete as required.
Supplying, installation, testing & commissioning of fire fighter
telephone handset complete as required.
Supplying, installation, testing & commissioning of fire fighter
phone jack complete as required.
Supplying & laying of 2x1.5 sqmm fire survival armoured
cable, 600/1000V rated with annealed copper conductor
having glass mica fire barrier tape covered by an extruded
layer of Cross Linkable Ethylene Propylene Rubber (EPR)
insulation and LSZH inner bedding, steel wire armouring &
LSZH outer sheath complete as required.
Public Address System : -
Supplying, installation, testing & commissioning of 6 zone,
voice alarm controller with USB, MP3 player (including 6
13 28.3.1 zone button paging station) with seamless integration facility 1 each 1,32,115.00 1,32,115.00 -
with main fire alarm panel for voice evacuation complete as
Supplying, installation, testing & commissioning of 1.5/3/6W
ceiling speaker complete as required.
Signature of Tenderer 80 Signature of NBCC
Supplying, installation, testing & commissioning of digital
15 MR audio amplifier 500 Watt, 25V rms operating at 240 Volt AC 1 each 45,000.00 45,000.00
Supply complete as required.
Supplying, installation, testing & commissioning of Voice
16 28.3.9 command keypad 6 zone, with microphone assembly complete 1 each 85,450.00 85,450.00 -
Supplying and drawing of cable Fire Retardant PVC insulated
copper conductor cable in the existing surface / recessed steel
conduit of following pairs, cores and size including
connections and interconnections etc. as required.
a 28.5.3.1 17.5.3.1 speaker cable Single pair, 2-core, 1.5 sqmm 507 metre 61.00 30,927.00 -
18 1.21.2 Same as in item 148, but 25mm dia PVC conduit. 507 Meter 168.00 85,176.00 -
GRAND TOTAL (DSR+MARKET BASED ITEM) 11,42,647.00
GRAND TOTAL (DSR+MARKET BASED ITEM) 11,42,647.00
GRAND TOTAL (DSR+MARKET BASED ITEM) IN LAC 11.43
GRAND TOTAL (DSR+MARKET BASED ITEM) IN LAC 11.43
Signature of Tenderer 81 Signature of NBCC
Detailed Estimate Based On DSR-2025 With Cost Index & Market Rate
ICAI BHAWAN- GORAKHPUR SITUATED AT PLOT NO-B-11, TARAMANDAL, NEAR CIRCUIT HOUSE, OPP. RAMGARHTAL LAKE, GORAKHPUR
Name Of Work - Lift Work
Rate as per DSR 2025 MARKET BASED
Sr.N Rate as per
Sch.No. Particulars Qty Unit Amount Rate Amount
Supplying, Installation, Testing & Commissioning of
following capacity passenger Machine room less (MRL)
lift with regenerative drive as per CPWD General
Specification for Electrical Works (Part-III Lift &
Escalator) 2003, BIS Codes, NBC 2016 as amended upto
1 21.1 date, having provision for barrier free access as per
Harmonised Guidelines & Standards for Universal
Accessibility in India – 2021 of MoHUA, serving
different floors in the lift shaft as per detailed
specifications enclosed and as under including all other
equipment and accessories complete as required:—
(i) Speed – 1 MPS
(ii) Floors – 5 (G+4)
(iii) Travel – 17 metres (approx.)
(iv) Stops & openings – 5 stops and 5 openings
(v) Controller – A.C. variable voltage & variable
(vi) Automatic Rescue Device (ARD) complete with dry
maintenance-free batteries as required.
(vii) Operation – Microprocessor-based single automatic
push button/simplex selective collective/duplex
collective selective with/without attendant.
(viii) Power – 415 Volts ±10%, 3 phase, 50 Hz, 4 wire
(ix) Car enclosure – Stainless steel scratch-proof (Moon
Rock/Honeycomb/Hairline Finish) on all sides and
stainless-steel decorative ceiling with fans (indirect
throw) and LED fitting.
(x) Car flooring shall be smooth and anti-skid as
approved by Engineer-in-Charge.
(xi) Doors: Car door – power-operated, centre-opening
horizontal sliding stainless-steel scratch-proof; landing
doors – stainless-steel scratch-proof.
(xii) Handrail not less than 600 mm long at 900 mm
above floor level, adjacent to the control panel in the lift
Signature of Tenderer 82 Signature of NBCC
13 Passenger (884 kg)
Grand Total (DSR+MARKET BASED ITEM) 33,68,451.44
Grand Total (DSR+MARKET BASED ITEM) 33,68,451.44
Grand Total (DSR+MARKET BASED ITEM) In Lac 33.68
Grand Total (DSR+MARKET BASED ITEM) In Lac 33.68
Signature of Tenderer 83 Signature of NBCC
Detailed Estimate Based On DSR-2025 With Cost Index & Market Rate
ICAI BHAWAN- GORAKHPUR SITUATED AT PLOT NO-B-11, TARAMANDAL, NEAR CIRCUIT HOUSE, OPP. RAMGARHTAL
LAKE, GORAKHPUR (U.P.)
Name Of Work = CCTV
Rate as per D.S.R. 2025 Market Amount
Sr.No. Sch.No. Particulars Qty Unit Amount Rate Amount
1 2 MP IP IR Dome Camera
Supplying Installation Testing and Commissioning of 2 MP
IP IR Dome Camera having following specifications, type of
lens and features etc :-
1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50
dB, Camera should display Camera title, Date & Time in live
& recorded video 2)Image Sensor: 1/2.8" or better
progressive Scan CMOS to get color image even at night
condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC
ON, 0 lux with IR or better) True Day & Night High
Performance Mechanical IR cut filter with auto switch,
Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with
effective distance upto 50 meter or better and 30 meter for
colour view in night, Imaging: 1/3s to 1/30000s electronic
shutter support, Auto Gain Control , White Balance- Auto,
Back Light Compensation, Multi zone Privacy Masking,
HLC Digital Watermarking
Signature of Tenderer 84 Signature of NBCC
3) Compression (Minimum):-Video:- H.265 or better,
H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726,
4) Wide Dynamic Range:- WDR (120db or more)
5) Digital Noise Reduction:- DNR (3D) On/Off
6) Video Streaming & Frame Rates :- Triple streaming ,
configurable (Main stream: 2MP (1920×1080)@25/30
fps,Sub streams minimum: 720P@25/30 fps).
7) Image Setting: Rotate Mode, saturation, brightness,
contrast, sharpness adjustable through client software or web
browser, Edge Analytics: Tripwire, Intrusion, Motion
8) Cyber Security: AES 256-bit Encryption, Configuration
encryption, trusted execution, Digest, security logs, account
lockout, syslog, video encryption, IP/MAC filtering, HTTPS,
trusted upgrade trusted boot
9) Onboard Storage: Camera should support built-in
Micro SD/SDHC/SDXC Card slot upto 512 GB. It
should be supplied with minimum 128GB memory
10) Recording Management: Format SD, overwrite,
storage management, video to NAS device
11) Alarm Trigger : Motion/tampering detection; audio
detection; network disconnection detection; IP conflict
detection; memory card state detection; memory
space detection
12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP,
NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE,
NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS,
Signature of Tenderer 85 Signature of NBCC
13) System Capability: ONVIF, Camera shall support
open source VMS
14) Ethernet: 1 RJ 45 10/100 Ethernet port
15) Audio : It should support 1 x Built-In Mic and 1/1
Alarm In/ Out for External Mic. and Speakers as per
site requirement.
16) Power Input: The camera should support
simultaneous dual power input—12 VDC (via power
adapter) and PoE (802.3af)—to ensure continuous
operation in the event of a failure in one power source.
17) Power Requirement: 12VDC/24 VAC/PoE
18) Housing/ Enclosure:- IP67 weather proof, IK10,
19) Operating Condition:- Ambient Temperature:- (-
)05°C to 50°C, humidity 95% (max) (non-condensing)
20) IR life: 40000 hours or higher
21) Video Bit rate: 32 KBPS - 8 MBPS or better
22) Standards: BIS with ER, STQC Certified, CE, FCC
2MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome
Camera with 2.8/ 3.6mm fixed lens
2 2 MP IP IR Outdoor Bullet Camera -
Supplying Installation Testing and Commissioning of 2MP
Fixed Lens IP IR Outdoor Bullet Camera having
following specifications and features etc :-
1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50
dB,Camera should display Camera title, Date & Time in live
& recorded video
Signature of Tenderer 86 Signature of NBCC
2)Image Sensor: 1/2.8" or better progressive ScanCMOS to
get color image even at nightcondition(Minimum
Illumination: 0.006 Lux@ F1.4,AGC ON, 0 lux with IR or
better) True Day & NightHigh Performance Mechanical IR
cut filter with autoswitch, Integrated IR Source (Auto,
Manual)- InbuiltSmart IR LED's with effective distance upto
50 meteror better and 30 meter for colour view in
night,Imaging: 1/3s to 1/30000s electronic shutter
support,Auto Gain Control , White Balance- Auto, Back
LightCompensation, Multi zone Privacy Masking,
HLC,Digital Watermarking.
3) Compression (Minimum):-Video:- H.265 or better,
4) Wide Dynamic Range:- WDR (120db or more)
5) Digital Noise Reduction:- DNR (3D) On/Off
6) Video Streaming & Frame Rates :- Triple streaming,
configurable(Main stream: 2MP (1920 ×
1080)@25/30 fps Sub streams minimum:720P@25/30 fps).
7) Image Setting: Rotate Mode, saturation,
brightness,contrast, sharpness adjustable through client
softwareor web browser, Edge Analytics: Tripwire,
Intrusion,Motion Detection
8) Cyber Security: AES 256-bit Encryption,Configuration
encryption, trusted execution, Digest,security logs, account
Signature of Tenderer 87 Signature of NBCC
9) Onboard Storage: Camera should support built-inMicro
SD/SDHC/SDXC Card slot upto 512 GB. Itshould be
supplied with minimum 128GB memoryCard.
10) Recording Management: Format SD, overwrite,storage
management, video to NAS device,
11) Alarm Trigger : Motion/tampering detection;
audiodetection; network disconnection detection; IP
conflictdetection; memory card state detection; memoryspace
12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP,NTP,
RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE,NFS, UDP,
ICMP, SSL, DHCP, SMTP, RTSPS,unicast,
13) System Capability: ONVIF, Camera shall supportopen - -
DELHI SCHEDULE OF RATES (E&M)-2025
14) Ethernet: 1 RJ 45 10/100 Ethernet port
15) Audio : It should support 1 x Built-In Mic and 1/1Alarm
In/ Out for External Mic. and Speakers as persite
16) Power Input: The camera should supportsimultaneous
dual power input—12 VDC (via poweradapter) and PoE
(802.3af)—to ensure continuousoperation in the event of a
failure in one power source.
17) Power Requirement: 12VDC/24
VAC/PoE(802.3af)/ePoE
19) Operating Condition:- Ambient Temperature:- (-)05°C to
50°C, humidity 95% (max) (non-condensing)
20) IR life: 40000 hours or higher
21) Video Bit rate: 32 KBPS - 8 MBPS or better
22) Standards: BIS with ER, STQC Certified, CE, FCC
2MP @ 25/30fps@1080P (1920×1080) Outdoor Bullet
Camera with 2.8/ 3.6mm fixed lens
Signature of Tenderer 88 Signature of NBCC
Supplying Installation Testing and Commissioning of
following Channel Network Video Recorder (NVR)
with camera licenses to record for all channels having
specifications and features etc as mentioned below :
1) Network Video Recorder Embedded/ Installed OS
(Linux) along with Camera Licenses to record per NVR
and to provide a live view, storage and simultaneously
Multi-channel playback of all IP camera or more and
must be ONVIF with minimum support of 384 Mbps
incoming Bandwidth.
2) NVR should support video compressions : H.265 or
better, H.264, MJPEG.
3) Must support 1 channel RCA Input, 2 channel RCA
Output for Two-way Talk with G.711U/A, G.711u,
PCM, G726 audio compressions.
4) Intelligent auto power on when power resumes after
5) Storage: It should support minimum 8 SATA Slots - -
with 20TB capacity/ Slot and RAID support of RAID
6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps
Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port
7) Backup Interface : Its should have 4 Nosx USB port
(2x USB3.0, 2xUSB2.0)
8) Video Output Ports: 2x HDMI and 2 VGA
9) Alarm Ports: It should have 16/8 Ch In/ Out ports to
connect various type of external sensors and output
devices like hooter/ Siren etc.
10) Email & SMS Altert options: Option for SMS/
Email Alerts to minimum 5 designated mobile number
for power failure, HDD failure, vandalism, tempring,
network disconnection and panic
11) Web & Mobile Application: Web, Mobile app ( For - -
iPhone, iPad, Android Phone) for alerts and viewing.
12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6,
UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE,
FTP, DDNS, Alarm Server, IP Search, Multicast, Auto
Registration, ONVIF (Profile T, Profile S, Profile G),
CGI, SDK and OEM Cloud for remote monitoring
without any public IP need
Signature of Tenderer 89 Signature of NBCC
13) Standards: CE, FCC, RoHS, BIS Certified
14) Power Supply : Should support AC100-240V,
50/60Hz Power supply.
15) Operating Condition : -5°C to 50°C, humidity 90%
(max) (non-condensing)
16) The VMS application shall support all the features
& functionalities of the offered cameras. - -
17) VMS should consist Licenses for all channels to
record Cameras with General, motion detection,
intelligent, alarm and POS recording modes. VMS
should be provided with Camera Licenses , with no
dependency of VMS licenses by binding with the MAC
address of the cameras to achieve the functionality
18) The NVR OEM shall be responsible for providing a
mobile application compatible with both Android and
iOS devices, enabling remote monitoring and playback
of cameras/NVR footage.
19) The OEM must provide its own DDNS server
hosted in India, eliminating the need for a public IP - -
address for remote monitoring over the Internet.
20) Must support Continuous, Alarm, Motion, Instant,
Panic Recording Mode
21) It should support Resolution: 32MP; 24MP; 16MP;
12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF
22) When alarm recording is enabled and an even
occurs, you can click the alarm icon on monitoring
page to view the alert details. The snapshot function is
supported on monitoring and playback page
23) The Network Video Recorder (NVR) shall be
configured to send email whenever a system message
is created or an alarm event occurs. The email server
shall be a valid SMTP server. Each recipient email
address shall be configured to receive any
combination of critical, warning, or informational
messages or alarm notifications. When an alarm
occurs, the email message includes the NVR name,
time of alarm and a list of camera that is configured to
record upon alarm
Signature of Tenderer 90 Signature of NBCC
24) It should have Web and GUI interface
25) Built-In Artificial Intelligence: NVR should have
- 2 Channel face detection and recognition, - Minimum
4 Channel perimeter protection, - Minimum 8 Channel
Smart Motion Detection
26) Face Recognition Database Capacity: It should
support total Blacklist and Whitelist capacity of
Minimum 20,000 Faces or more with Face Detection
speed of 12 face images/sec and facility to add Name,
gender, birthday, address, credential type, credential
No., countries & regions and state to each face image
27) Face & Human Attributes Search: Search
Pictures/ Video by Gender, age group, glasses,
expressions, face mask, beard, Top color, top type,
hat, bag, age, gender and umbrella.
28) ANPR Capability: It should support ANPR
Camera with License plate, plate color, vehicle body,
vehicle model, vehicle logo, calling, seatbelt, vehicle
registration location etc vehicle attributes.
29) Alarm Notifications based on: Motion detection,
video tampering, video loss, scene changing, PIR
alarm, Camera external alarm, Face detection, face
recognition, perimeter protection (intrusion and
tripwire), ANPR, people counting, stereo analysis,
crowd distribution, heat map, Disk Full, Storage Error,
IP Conflict and abnormal behavior of fan,
cybersecurity exception
Signature of Tenderer 91 Signature of NBCC
30) Alarm Notification should be linked with Recording
snapshots, Camera external alarm output, buzzer,
logs, presets and email.
31) General AI Based Search: Search Pictures by
channel, time, event type, target classification (Fall
Detection, People Approach Detection, People No.
Exception Detection, People Staying Detection,
Violence Detection.
32) Smart playback function: Should support smart
search for the selected area in the video and smart
playback to improve the playback efficiency
33) VCA (Video Content Analytic): Should support
multiple video contented analytics based on camera
34) Analytics by NVR: Perimeter protection and face
32 Channel Network Video Recorder (NVR) having
screen: 1/4/8/9/16
Hard Disk Drive - -
Supplying, Installation, Testing and Commissioning
following capacity Serveillance grade Hard Disk with
upto 256MB/s Transfer Rate, 256 MB Cache, 7200
4 RPM Disk Speed, 3.5 inch form factor, SATA - -
Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC,
Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL
Certifications.
Signature of Tenderer 92 Signature of NBCC
Supplying, installation, Testing and commissioning of
following capacity 8 port Layer 2 indoor Network
Switch having features and specifications etc. as
mentioned here under: Minimum 8 X RJ-45 Gigabit
Ethernet Ports and additional 2 X 1G SFP Ports with
non-blocking architecture by having Switching capacity
of minimum 20Gbps and packet forwarding rate of
5 14Mpps or higher, 8K MAC table. Internal dual AC - -
Power supply with operating temperature of -5 0C to
+50 0C. Jumbo frame: 10KB or higher, IGMP
Snooping, IGMP snooping querier and support for
IGMP Snooping Fast Leave, Should create 250 or
more MLD groups, MLD Snooping, Per VLAN MLD
Snooping C MLD Snooping Fast Leave, STP, RSTP,
MSTP Loopback detection Multicast filtering VLAN
Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6
Interface : minimum 100 IPv4 static route entries and
minimum 50 IPv6 static route entries, 700 Acess
Control entries, SSH CSSL for IPv4 and IPv6, 802.1x,
ARP Spoofing, DHCP Snooping and server screening,
IP+MAC+Port Binding, Per Port Bandwidth Control,
802.1X Authentication (Supports local/RADIUS
database, Port-based Access Control and EAP, OTP,
TLS, TTLS, PEAP Support) Cable Diagnostic feature,
LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1,v2c,
v3 and SNMP Traps. Certifications: UL, CE, FCC,
RoHS, MTCTE, OEM/Product must be on Trusted
Telecom Portal of Department of Telecommunication,
Government of India etc. complete as required
8 port PoE Layer 2 Network Switch with PoE Support
39.1.1 of 130W or higher with each copper port supporting 1.00 Each 35,091.00 35,091.00 -
Signature of Tenderer 93 Signature of NBCC
Supplying, installation, Testing and commissioning of
following capacity 24 port Layer 2 indoor Network
Switch having features and specifications etc. as
mentioned here under: At least 24 X RJ-45 Gigabit
Ethernet Ports and additional 2 X 10G Base -T with 4
X SFP Ports with non-blocking architecture by having
Switching capacity of min. 168Gbps and packet
forwarding rate of 125Mpps or higher, 16K MAC table.
Console Port, USB port, Stacking support of min. 8
units per stack. Internal dual AC Power supply, STP,
RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K
Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD
Snopping V1/V2. IGMP /MLD Groups 1K or more,
IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6
ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ,
Port based Ǫ-in-Ǫ Multicast VLAN Protocol VLAN
VLAN Trunking, DHCP Snopping, Server, server
Screening. RADIUS , TACACS+ Authentication,ǪoS:
802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR,
WRED, 802.1p. ACL: MAC based, IPv4C IPv6,
TCP/UDP Port number, time based ACL, TFTP Client,
SNMP V1, v2c, v3, SNMP traps, RMON, DHCP
server, relay, client, LLDP, LLDP-MED, OAM, Dying
Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based
route, SSL, SSH. 6 kV surge protection on all Gigabit
Ethernet ports and on all GE RJ-45 access ports.
Certifications: UL, CE, FCC, RoHS, MTCTE,
OEM/Product must be on Trusted Telecom Portal of
Department of Telecommunication, Government of
India etc. complete as required
24 port PoE Layer 2 Network Switch with PoE
39.3.1 Support of 370W or higher with each copper port 1.00 Each ######### 1,25,393.00 -
supporting 802.3at PoE+ min.
Supplying Installation Testing and Commissioning of
24 port Cat6 Patch Panel loaded. Must be of 1U height
with clear label holders and white label with the panel.
24 Ports Cat-6 Patch Panel should have ETL/UL
verification program certificate for compliance with
ANSI/TIA-568.2-D etc. complete as required
Signature of Tenderer 94 Signature of NBCC
Supplying, Installation, Testing and commissioning of
following CAT6 Patch Cord should have ETL/UL
verification program certificate for compliance with
ANSI/TIA-568.2-D etc. complete as required
39.12.1 Copper Patch Cords of length 1m (3ft) 32.00 Each 151.00 4,832.00 -
39.12.2 Copper Patch Cords of length 3m (10ft) 1.00 Each 227.00 227.00 -
Supplying, Installation, Testing and commissioning of
CAT6 Copper Information Outlet (IO) with face plate
of color as per site requirement, should have ETL/UL
9 39.14 verification program certificate for compliance with 32.00 Each 212.00 6,784.00 -
ANSI/TIA-568.2-D. All copper Cable and Components
should be from same OEM to maintain compatibility
and interoperability etc. complete as required
Supplying, Installation, Testing and commissioning of
RJ45 Connector for CAT 6/6A Cables. RJ45 modular
plug supports 4 twisted pairs, 8 positions, 8
connectors. Housing: PC, UL94V-2, transparent color,
Use for 24- 26 AWG stranded wires etc. complete as
Supplying, drawing, Installation, Testing and
commissioning of CAT6 UTP LSZH 23AWG Twisted
Pair Cable in existing conduit/ on surface, Category 6
Unshielded Twisted Pair, 4 pair should be complied as
per UL/ETL verification program for compliance with
ANSI/TIA-568.2-D standard. Outer diameter should be
in the range of 6.1mm nominal with Operating
Temperature Range : -5° to +60°C, Bending Radius :
< 4 X Cable Diameter at –5°C ± 1°C and Pulling Force
: 11.5Kg etc. complete as required.
Supplying and fixing of following sizes of medium class
PVC conduit along with accessories in surface/recess
including cutting the wall and making good the same in case
of recessed conduit as required. 25mm Dia
Signature of Tenderer 95 Signature of NBCC
Supplying and fixing of following size Wall Moun
Rack having Fixed Structure with 0.8mm CRCA
Sheet, completely knocked-down condition (CKD)
Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking,
Minimum 2 cable entry/exit provision at Top and
13 bottom with rubber protection, Front 5mm Toughened - -
Glass with lock, wall mounting kit, Powder coated
Color- RAL- 7035, complied with UL & RoHS, 2 x 6
sockets 16A power distribution units, 3 numbers
closed cable organizer, Hardware mounting screws
packet of 20 x 1 number, etc. complete as required
14 PC System -
Supplying Installation Testing Commissioning of Clien
PC System comprising of PC Hardware with
minimum11th Gen Intel® I7 processor CPU E5-2640
x64 (or better), compatible with dual and quad core
processors minimum 3.1 Ghz and 8GB or higher RAM,
42.2 Hard Drive Space of 256 GB SSD or better, Video 1.00 Each 90,698.00 90,698.00 -
card and monitor capable of 1920 x 1080 pixel
resolution or better with Ethernet adapter
(10/100/1000 Mbps with RJ-45 connector) with 2 GB
or higher Graphics card suitable for BMS System
complete etc. as required
Supplying, Installation, Testing and Commissioning of
following size LED display (LED monitor) industrial
grade with 3840x2160 resolution or better, USB
playback, bluetooth and miracast connectivity, 4X
HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits
15 or better, Video wall mode should be available, -
contrast ratio: 1200:1, OPS slot, viewing angle (H/V):
170°/ 170°, response time less than 12ms, Display
control shall be on monitor screen and programmable
with remote (remote shall be supplied with system),
Key Board, Optical Mouse, etc. as required
Signature of Tenderer 96 Signature of NBCC
Grand Total (DSR+MARKET BASED ITEM) 9,21,839.00
Grand Total (DSR+MARKET BASED ITEM) 9,21,839.00
Grand Total (DSR+MARKET BASED ITEM) In Lac 9.22
Grand Total (DSR+MARKET BASED ITEM) In Lac 9.22
Signature of Tenderer 97 Signature of NBCC
Detailed Estimate Based On DSR-2022 With Cost Index & Market Rate
ICAI BHAWAN- GORAKHPUR SITUATED AT PLOT NO-B-11, TARAMANDAL, NEAR CIRCUIT HOUSE, OPP. RAMGARHTAL LAKE, GORAKHPUR (U.P.)
Name Of Work - EPABX & Networking System Work
Rate as per D.S.R. 2025
Sr.No. Sch.No. Particulars Qty Unit Amount Rate Amount
A EPABX SYSTEM
1 MR SITC of 20 Channel EPABX System with loop card etc as required. 1.00 Nos 45,500.00 45,500.00
2 MR SITC OF BASIC PHONE WITH CLI 8.00 Nos 1,170.00 9,360.00
3 MR S/f of I/O Boxes Krone connectors ,with connection etc
3 MR Wiring of Jelly Filled telephone Cable in existing pipe for system with connection
TOTAL A 63,122.00
B DATA / NETWORKING SYSTEM
1 MR SITC of 1m long Cat-6 patch cord as required 110.00 Nos 190.00 20,900.00
1 MR SITC of 2m long Cat-6 patch cord as required 110.00 Nos 220.00 24,200.00
S/I/T/C of 48 port category 6e SL Series fully loaded patch Panel Make Dlink/Amp with
active and passive components,punching, complete in all respect
Supply, Installation, Testing & Commissioning of Access Enterprise PoE Network Switch:
48 Port10/100/1000 Base-T PoE+ with 4 x 10G SFP+ ports Managed Switch. PoE budget
minimum 740W further expandable up to 1440W and during the reboot of switch
connected end point should get PoE Power. FlexStack-Plus Capability and minimum 8
switches to be stack in single stack;2GB or Higher DRAM and 4GB or higher Flash,
600MHz Dual Core or Higher CPU; 176Gbps or Higher switching bandwidth; 4K VLAN ID;
130 Mpps or higher forwarding rate; The switch should support Digital Network
Architecture and SD Access. The switch should support redundant power supply unit..
The switch should support standard proocols: IEEE 802.1D STP, IEEE 802.1p CoS
Prioritization; IEEE 802.1ab (LLDP); IEEE 802.3ab 1000Base-T; IEEE 802.3z 1000 Base-X;
IEEE 802.3x Full Duplex on 10/100/1000 Base-T Ports; SNMP v1, V2c and V3; Safety
Standards like UL; EN; IEC;EMC; RoHS
Supply, Installation, Testing & Commissioning of Core Enterprise Network Switch: 16 x
10G SFP+ ports and 8 x Gigabit Ethernet Ports Managed Switch. Virtual Stack Capability;
16GB or Higher DRAM and 16GB or higher Flash, 2.4GHz Quad Core or Higher CPU;
480Gbps or Higher switching bandwidth; 4K VLAN ID; 360 Mpps or higher forwarding
rate; The switch should support Digital Network Architecture and SD Access. The switch
should support routing protocols like static routing, RIPv1, RIPv2, RIPng, OSPF, BFPv4,
EIGRP, IS-ISv4, IPv6 Routing etc from day one. The switch should support standard
proocols: IEEE 802.1D STP, IEEE 802.1p CoS Prioritization; IEEE 802.1ab (LLDP); IEEE
802.3ab 1000Base-T; IEEE 802.3z 1000 Base-X; IEEE 802.3x Full Duplex on 10/100/1000
Base-T Ports; SNMP v1, V2c and V3; Safety Standards like UL; EN; IEC;EMC; RoHS.
Signature of Tenderer Signature of NBCC
Supply, installation, testing, and commissioning of Enterprise-Grade Indoor Wi-Fi 6
(802.11ax) Wireless Access Point. Must support dual-band concurrent operation (2.4GHz &
5GHz), minimum 4x4 MU-MIMO technology, and an aggregate wireless data rate of at least
3.0 Gbps. Hardware must handle a minimum of 200+ concurrent associated client devices
(optimized for 60+ active heavy users). Must support 802.3at Power over Ethernet (PoE+),
WPA3 security enterprise standards, seamless roaming (802.11r/k/v), and centralized cloud
or hardware controller management. Complete with ceiling/wall mounting brackets and all
necessary accessories.
Supplying, installing, testing and commissioning of 6 U wall mount rack with fans , 2 cable
managers , satationary shelf , 2 Nos of hardware pkts.
Supplying, installing, testing and commissioning of 42 U wall mount rack with fans , 2 cable
managers , satationary shelf , 2 Nos of hardware pkts.
8 MR Mapping of Network Nodes & LAN Diagram 1.00 Job 72,000.00 72,000.00
Grand Total (A+B) 16,08,561.17
Grand Total (A+B) 16,08,561.17
Grand Total (A+B) in Lac 16.09
Grand Total (A+B) in Lac 16.09
Signature of Tenderer Signature of NBCC
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
detail.html
html • 0.06 MB
NIT.pdf
Tender Document
SCC.pdf
Tender Document
GCC amendment up to 4.pdf
Tender Document
GFC DRAWINGS-ICAI BHAWAN GORAKHPUR.pdf
Tender Document
ICAI Integrity Pact.pdf
Tender Document
ICAI-Soil Test.pdf
Tender Document
Instruction-to-Bidder-for-online-Bid-Submission.pdf
Tender Document
Technical Specifications - NBCC ICAI BHAWAN GORAKHPUR.pdf
Tender Document
Technical Circular up to 36.pdf
Tender Document
BOQ.pdf
Tender Document
Schedule of Finishes- NBCC ICAI BHAWAN GORAKHPUR.pdf
Tender Document
corrigendum-5581-Addendum 01.pdf
pdf • 3.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .