Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹8.6 L+₹1.6 L (23.5%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹9.4 L+₹2.4 L (34.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹10.6 L+₹3.6 L (51.9%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹12.9 L+₹5.9 L (84.3%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
19 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SAMBA
GE SAMBA PIN 184121
REPAIR REPLACEMENT OF SECURITY LIGHTS IN OTM AND MD ACCN OF ZONE I II III UNDER GE SAMBA
2024_MES_656878_1
GE/SMB/T-08/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE SAMBA
CATEGORY E b i
8 documents required · 8 mandatory
₹500
GE SAMBA
₹30,000
4 Oct 2024
30 May 2024
26 Jun 2024
30 May 2024
19 Jun 2024
13 Jun 2024
Amount
Maintenance of street light fitting on pole / wall at any height,including cleaning of complete fitting / fixture, removing carbon from connection, tighting of bulb etc including replacing LED driver where required and making street light functional complete all as specified and directed. Note - LED driver where replaced shall be measured as supply only under relevant item.
Supply only LED security light driver of approved company suitable for LED fittings of cap upto 45 watts any type , complete all as specified and directed.
Supply only LED security light driver of approved company suitable for LED fittings of cap upto 45 to 60 watts any type , complete all as specified and directed.
Supply only LED security light driver of approved company suitable for LED fittings of cap upto 60 to 120 watts any type , complete all as specified and directed.
Supply and fixing in repair of 90W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Supply and fixing in repair of 60W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Supply and fixing in repair of 35W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Note for srl item No 5 to 7 above 1. Driver shall be potted anti-vibration types. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be provided. 3. CRI (Colour Rendering Index) of fixture shall be > 70. 4. CCT (Colour Co-related Temperature of fixture shall be 5700K + 300 K. 5. System Lumen Efficacy shall be > 100 Lm/W. 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. Two(02) years guarantee shall be provided by contractor supported by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type. 10. The defect liability period of LED light shall be 05 years from the certified date of completion & the contractor shall replace/repair the defective fitting within 07 days after handing over to contractor for replacement/repair. 11. CA No. shall be written on each fitting before installation. 12. The name of manufacturer to be embossed on the fitting. 13. The fittings shall have arrangement so that maintenance required, if any can be carried out from top cover.
Replacement of old UNSV / damaged street light fitting any type and S & F LED Flood Light luminaire in pressure die-cast aluminium housing with IP66 protection 30 watts, 230 volts, 50 Hz, area lighting including 30 watts LEDs and driver complete all as specified and directed. .
Replacement of old UNSV / damaged street light fitting any type and S & F LED Flood Light luminaire in pressure die-cast aluminium housing with IP66 protection 100 watts, 230 volts, 50 Hz, area lighting including 100 watts LEDs and driver complete all as specified and directed. .
S&F in repair New generation, 15 Watt post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete all as specified and directed.
S&F in replacement cable of size 16 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminiun conductor, served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm suspended with galavnised steel wire, complete all as specified and directed.
S&F in replacement cable of size 10 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminiun conductor, served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm suspended with galavnised steel wire, complete all as specified and directed.
Supply and fixing in replacement of old unserviceable aluminium conductor cable single core PVC insulated and sheathed aluminium conductor cable of size 2.5 sqmm down through the existing pole/GI pipe bracket complete all as specified and directed.
Supply and fixing as in reapir / replacement of pole mounted street light factory fabricated junction box of size 300mmx160mmx250mm of approved make and of appropriate size made out of 2 mm thick CRCA powder coated sheet , including 63A ,Three Phase four wire having four no.AL Bus Bar including 6A SP MCB. The box should have auto Door Lock facility with magnetic Lock having Sizehaving Size box fixed on pole using necerssary fixing arrangement such as clamps,nut,bolts and washer including taking down existing junction box of any description/type etc complete all as specified and directed.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated PVC sheathed, armoured heavy duty electric cable , with aluminium conductor of size 25 Sqmm x 4 core complete all as specified and directed. Note:- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
All as per srl item No 15 here-in-before, but cable of size 16 Sqmm x 4 core complete all as specified and directed.
All as per srl item No 15 here-in-before, but cable of size 16 Sqmm x 2 core complete all as specified and directed.
All as per srl item No 15 here-in-before, but cable of size 10 Sqmm x 2 core complete all as specified and directed.
Excavating in trenches in any type of soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out complete all as specified and directed.
Removing excavated material (soil) n.exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
M&L for dry clean fine river sand as in sand cushioning to underground cable 8cm below and 15cm above the cable including punning down of sand layer complete all as specified and directed. Note :- Punned thickness shall only be measured and paid.
M&L for brick protection with sub class 'B' old size brick well burnt laid flat for cable protection abutting each other laid dry with width equal to length of brick complete all as specified and directed.
Supply and fixing in replacement GI tubing light grade 40 mm bore cut to size and fixed along the pole for cable protection including clamp 02 Nos of size 25x4 mm, nut bolts , washers etc complete all as specified and directed.
Note :- The contract sum shall be arrived at after deduction of amount of sch of credit
G.M. ENGINEERING SERVICES
dadwal engineers
M/S GUPTA TRADING CO
LAL CONSTRUCTIONS
SIDDAHANT ENTERPRISES
satpal and brothers
Standard engineers
AGGARWAL ASSOCIATES
JAI DURGA CONSTRUCTION CO
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .