Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.0 LAccepted-Finance 10 A SAURASTRA PATEL SOCIETY OPP YAGNIK HALL NR BHIDBHANJAN BAPUNAGAR AHMEDABAD 380 024 | AHMADABAD | GUJARAT | 380024 | ₹22.0 L | 1 | Accepted-Finance as per BOQ Summary |
| 2 | 2₹22.6 L+₹52,940 (2.40%)Accepted-Finance | ₹22.6 L+₹52,940 (2.40%) | 2 | Accepted-Finance as per BOQ Summary |
| 3 | 3₹28.6 L+₹6.5 L (29.6%)Accepted-Finance | ₹28.6 L+₹6.5 L (29.6%) | 3 | Accepted-Finance as per BOQ Summary |
Tender Value
Refer Docs
EMD Value
₹41,427
Closing Date
5 Apr 2021, 11:00 amClosed
2IC/EE(ELECT) FTR HQ BSF GUJ
FTR HQ BSF GANDHINAGAR GUJARAT
Augmentation of existing outlived transformer including cabling, distribution feeder pillar at substation of BSF campus Gandhinagar FTR HQ BSF Gujarat SH SITC of 630 KVA 11/0.433 KV Oil Cooled Distribution Transformer
2021_BSF_623792_1
08/FTR-GUJ(Elect)/eNIT/2020-21
Open Tender
Electrical Works
Works
90 days
BSF Campus Gandhinagar
as per tender inquiry
6 documents required · 6 mandatory
₹0
₹41,427
9 Apr 2021
24 Mar 2021
7 Apr 2021
24 Mar 2021
5 Apr 2021
24 Mar 2021
24 Mar 2021 - 5 Apr 2021
Amount
Supplying, installation, testing and commissioning of oil cooled type 630 KVA, 11KV/433 Volts, 3 Phase,50 Hz, Dyn-11, outdoor ONAN type, copper wound transformer with OFF load tap changing arrangement on HV side in steps of ± 2.5% & -7.5%, having cable end box of suitable size on HV side and 1000 amps bus trunking arrangement / suitable size aluminium conductor cables termination arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 2026 (Part 1 to Part 5) and as per specification attached complete in all respect as required at site. ( Kirlosker / ABB / Schneider Electric/ Alstom / Crompton Graves/ Siemens Make )
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3 core 120 sq. mm, XLPE aluminium conductor cable of 11 KV grade as required
Dismantling , disconnection and removing the existing 315 KVA, 11KV/433 floor mounted transformer safely with out damage from substation & placing same in store of Engineering Branch in BSF campus Gandhinagar
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required
Supplying, installation, including suspension, testing and commissioning of following capacity bus trunking with aluminium bus bars having current density of 130 A/ sq cm at nominal current rating in 1.6mm thick IP 42 sheet steel enclosure in convenient sections for use on, 3 phase, 4 wire, 415 V, 50 Hz, A.C. supply including jointing of sections, flexible joints, expansion joints, bends and earthing with 2 runs of galvanised iron strips, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required
Supplying and Laying of of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5 x 240 sq. mm size in the existing masonry open duct as required. Havells/Polycab/RR Kabel/Finolex
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
3½ X 120 sq. mm (45mm)
3½ X 150 sq. mm (50mm)
3½ X 185 sq. mm (57mm)
3½ X 240 sq. mm (62mm)
Supplying, Installing, testing and commissioning of compartmentalised type cubiclepanel board, 7 tank processed made of 2 mm thick CRCA sheet steel providing with suitable size angle iron and channels support with suitable size of base channel for floor mounting, dust & vermin proof duly phosphatized & powder coated, inclusive of 500 Amp 4 strip Aluminium busbar covered with heat shrinkable sleeves of suitable size and length., providing. inter-earthing and inter-connection with PVC insulated copper conductor cable of suitable sizes and lugs on both ends of each cable and providing and fixing of of below noted accessories. ( Apprx. Front area of panel shall be 2.24 sqmtr i.e 1600 mm length x 1400 mm height x 450 mm width) (i)MCCB 04 Pole 500 Amp 50 Ka ,C Frame, adjustable thermal and adjustable magnetic setting, Havells/C&S/L&T/Schneider. 01 nos (ii) MCCB 04 Pole 320 Amp 36 Ka , L Frame, adjustable thermal and fixed magnetic setting, Havells/C&S/L&T/Schneider. 02 nos (iii) MCCB 04 Pole 250 Amp 36 Ka , L Frame, adjustable thermal and fixed magnetic setting, Havells/C&S/L&T/ Schneider. 03 nos (iv) Panel mounted multifunction meter LCD display type digital VIFP, HPL/Risabh/L&T/Mecco (v) Indicator Lamp LED type-3 Nos (vi) CTs (5/500 A)- 3 Nos (vii) Door mounting rotory handle for MCCBs Havells/C&S/L&T/Schneider. 06 nos
Providing and fixing 1000 /5 current transformer in existing cubicle panel board including making connections, etc. as required.
Providing and fixing AC Ammeter 96 x 96 (0 to 1000 A) in existing cubicle panel board including making connections, etc. as required.
Painting , maintanance and cleaning of existing main LT distribution panel i/c providing MS rear panel doors 1.6 mm thick with hinges/locking bolts, tightning /insulating of cable connections and cleaning of RCC trench etc as per site requirement.
shivalaycorporation
Rhythm Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .