Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹39,360
Closing Date
23 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Exen.Engineer
Shalimar
Please see Enit
2021_SKUST_120768_1
Enit-28 of 2020 (Fresh)
Open Tender
Miscellaneous Services
Item Rate
20 days
Shalimar
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
Asstt.comptroller
₹39,360
Yes
25 Mar 2021
17 Mar 2021
25 Mar 2021
17 Mar 2021
23 Mar 2021
17 Mar 2021
120 days
Amount
SSupply , installation of Servo Voltage Stabilizer with specifications as : • Capacity : 300 KVA, 3 Phase • Input voltage : 208-482 V PP(120-280VNP) per Ph. (120-467 V) • Output voltage 400V +- 1% (230VAC) • Winding material 99.97% pure copper wound strip with fibre glass insulation • Dimmers with heat sink based technology, micro-controller LCD RS 485 interface • Protection- overload, high voltage, under voltage, delay line, single phase preventer, neutral failure through micro-controllers • Radiator for cooling of oil • Design as per IS 9815, 2026 • Accuracy : 415 +1% • Cooling : Naturally and Oil cooled • Complete with Oil topping • Speed of Correction : >8 V per second • Type: un Balanced Type • Winding: Full Copper wound • Efficiency: 98% • Auto/Manual operation facilities. • Fully solid state circuit using triacs/thyristor. • Three number Voltmeter (0-500V) provided for reading input/output voltages • Overload/under load protection with oil topping , high cut , low cut Make: Alba/Integ/Convergence/Deltron/Chinar /Elient/servokon
Supply , installation of Servo Voltage Stabilizer with specifications as : • Capacity : 200 KVA, 3 Phase • Input voltage : 208-482 V PP(120-280VNP) per Ph. (120-467 V) • Output voltage 400V +- 1% (230VAC) • Winding material 99.97% pure copper wound strip with fibre glass insulation • Dimmers with heat sink based technology, micro-controller LCD RS 485 interface • Protection- overload, high voltage, under voltage, delay line, single phase preventer, neutral failure through micro-controllers • Radiator for cooling of oil • Design as per IS 9815, 2026 • Accuracy : 415 +1% • Cooling : Naturally and Oil cooled • Complete with Oil topping • Speed of Correction : >8 V per second • Type: un Balanced Type • Winding: Full Copper wound • Efficiency: 98% • Auto/Manual operation facilities. • Fully solid state circuit using triacs/thyristor. • Three number Voltmeter (0-500V) provided for reading input/output voltages • Overload/under load protection with oil topping , high cut , low cut Make: Alba/Integ/Convergence/Deltron/Chinar /Elient/servokon
Supply , laying of 1100 V 3.5 core 240 MM XLPE armored cable XLPE Make Havells/Polycab/Gloster /Finolex
Supply , laying of 1100 V 3.5 core 400 MM XLPE armored cable XLPE Make Havells/Polycab/Gloster /Finolex
Supply , laying of 1100 V 3.5 core 185 MM XLPE armored cable XLPE Make Havells/Polycab/Gloster /Finolex
Supply /installation of Auto changeover 400 AMP 4 pole with mountage and panel etc Havelll’s/SSK/Equivalent/L&T
Supply /installation of Auto changeover 200 AMP 4 pole with mountage and panel etc Havelll’s/SSK/Equivalent/L&T
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3½ X 400/240 sq. mm (82mm)
3½ X 185 sq. mm (40mm)
160 mm dia (OD-160 mm & ID-135 mm nominal)
200 mm dia (OD-200 mm & ID-175 mm nominal)
SITC of MCCB 400 Amp TPN Legrand /hager make having breaking capacity 70kA including termination job
SITC of MCCB 315 Amp TPN Legrand /hager make having breaking capacity 70kA including termination job
S/I of speaders link copper 400/250/63 Amp Make
Fabrication, supply, installation, testing & commissioning of outdoor type compartmentalized feeder pillar having front area not less than 0.60 Sqmtr (900 mm x 900 mm) and depth 45 Cm (NS) made out of 2mm thick CRCA sheet with tappered roof having separate cable and bus bar alley, 1 door arrangement i/c locking arrangement, having 1000 Amp four pole aluminium bus bar of full length with base frame made out of 50mmx50mmx6mm (thick) angle iron having 80cm legs for erection in ground with construction of cement concrete suitable foundation size complete with connections and interconnections with copper conductor PVC insulated cables/ insulated aluminium busbar strips of appropriate size and terminal blocks (on outgoing) including supplying & fixing following switchgears & accessories there in, powder coating, labelling, earthing etc. complete as required. Providing and fixing following accessories in existing cubical panel board i/c making connection etc. as reqd.
Fabrication of shed with GI roofing and covering etc as per drawing and details as per site requirement
Note:-The rates quoted are inclusive of all carriages (Mechanical/Manual) of materials from source to site work and all extra charges complete in all respects.
Grun Umwelt Energy Pvt
M/S FRIENDS ELECTRICAL /MECH/ELECTRONICS
stage.html
html • 0.02 MB
finance_232322.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .