| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹20.8 L+₹1.2 L (6.19%)Rejected-Finance | L2 | Rejected-Finance Being not L1 bidder | |
| 3 | L3₹22.3 L+₹2.8 L (14.1%)Rejected-Finance D NO 4 96 40 27 FLAT NO 307 GREEN CASTLE APARTMENT GOPALAKRISHNA NAGAR SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | L3 | Rejected-Finance Being not L1 bidder | |
| 4 | L4₹23.3 L+₹3.7 L (19.1%)Rejected-Finance MIG 2B 65 VINAYAKA NAGAR VUDA COLONY VISAKHAPATNAM 530044 | VISAKHAPATANAM | ANDHRA PRADESH | 530044 | L4 | Rejected-Finance Being not L1 bidder | |
| 5 | L5₹24.5 L+₹5.0 L (25.4%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L5 | Rejected-Finance Being not L1 bidder |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
25 Feb 2023, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIRS AND DEHYDRATION OF TRANSFORMER OILS, MAINTENANCE OF TRANSFORMERS OF VARIOUS CAPACITY INCLUDING IMPROVISATION OF EARTHING / LIGHTNING CONDUTORS AT VARIOUS POCKETS OF DOLPHIN HILL AREA UNDER AGE E/M NO-II OF GE(U-I) VISAKHAPATNAM
2023_MES_577823_1
8502/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
As per NIT
6 documents required · 6 mandatory
₹500
Garrison Engineer Utility-I
₹78,000
Yes
3 Mar 2023
28 Jan 2023
27 Feb 2023
28 Jan 2023
25 Feb 2023
13 Feb 2023
Amount
M&L for disconnecting carefully electrical connection from both HT/ LT (primary & secondary) sides of the transformer, keeping them at safe side and taking out the burst transformer/Voltage stabiliser indoor/ outdoor type of capacity 500 KVA to 750 KVA, 11 KV/ 0.433 KV, step down any make for carrying out complete overhauling which shall comprise of the following:- a) M&L for lifting, transporting, handling, the transformer to workshop (including back to the original location after complete overhauling) and opening top cover of the transformer by unscrewing nuts, bolts, washers etc. including disconnecting core assembly from HT/ LT bushing and lifting the same gently and taking out from the shell (container/ body) of the transformer. b) Conducting the tests on core and windings as per IS like ratio, magnetic imbalance, short circuit etc. in presence of Engr-in-Charge and test results shall be signed both by the contractor and Engineer -in-Charge and kept on record. Note:- (i) Any damage to insulators/ bushes/ windings etc. while in the custody of the contractor shall be made good at no extra cost to Department. The serviceability of the transformer shall be checked and confirmed by the contractor before taking into his custody. (ii) M&L for rewinding / re-insulation of HT/ LT (primary / secondary) coils, bushes, studs, Transformer oil,cable box, replacement of buchholtz relay / MOG if any etc will be measured and paid separately.
All as per Sl Item No. 1 here-in-before but transformer / Voltage stabiliser indoor / outdoor type of capacity up to 250 KVA to 400 KVA.
All as per Sl Item No. 1 here-in-before but transformer / Voltage stabiliser indoor / outdoor type of capacity up to 63 KVA to 200 KVA.
Filtration of transformer oil of transformers / FRMUs installed at various locations to achieve di-electric strength not less than 60 KV at 2.5mm gap as per relevant IS with portable filtration plant, testing of the oil for the di-electric strength before filtration and after filtration complete all as directed by the Engineer-in-Charge.
Supply and topping up of transformer oil with di-electric strength not less than 60 KV into the conservator tank / body tank of the transformer / OCB / FRMUs etc at various locations complete all as directed by the Engineer-in-Charge. Make: Apar (Power Oil) / Savita (Transol) / Asian
M&L for rewinding of distribution (HT/LT) transformers of capacity 63 to 750 KVA type by winding the defective coils with new copper wire as per I.S. of same gauge and existing size together with new insulated materials / bracings before placing in to the transformer and assembling the coil with new insulation and fitting the coils in the chamber, testing and commissioning the transformer and recording the test results complete all as directed. Note: M&L for re-insulation of serviceable coils will be measured & paid separately under relevant items.
M&L for re-insulating windings of HT / LT distribution transformers of capacity 63 to 750 KVA by strip opening of HT / LT coils (i.e. Primary / secondary coils) from core assembly safely, unwinding the HT / LT coils (i.e. Primary / secondary coils) complete, removing the old defective insulation paper and replacing with new DPC insulation to the copper conductor, re-varnishing of the windings with super varnish including heating, drying, backing complete carefully and thoroughly inside the heating chamber at suitable temperature to obtain required value of insulation resistance etc. all as directed by Engr-in- charge.
Disconnection of the distrubution transformer of capacity 63 to 750 KVA from HT and LT supply mains, removing of Bus duct and Bus bar, leakage arresting by draining out of oil after arrangement of necessary empty oil drums, buckets etc.,dismantling of top cover and acessories, dismantling of LT bushings by disconnecting leads / jumpers from inside, replacement of gaskets and oil seals and re fixing of the LT bushings, making internal and external connections, replacement of cover gasket and acessories, reassembling of acessories and cover, filling back of existing transformer oil complete and making cable connections and assesting for energising the transformer complete all as specified and as directed. Note: (i) The rate quoted shall include cost of materials like gaskets and oil seals and labour etc. (ii) Bushing and bushing rods shall be measured and paid separately.
Disconnecting the HT/LT connections of transformer of capacity 63 to 750 KVA i.e (Bus duct / Cable bunch) keeping all the cables out from the HT/LT sides, physically checking the transformer for healthyness, performing the transformer tests like Meggar test, Ratio Test, Magnetic Balance test and short circuit tests for checking condition of transformer complete all as specified and as directed. Note:- (i) All testing shall be done in presence of Engr-in-Charge or his accredited rep and test reports shall be signed by contractor and Engr-in-Charge and kept on record. (ii) If the transsformer found satisfactory then HT/LT connections shall be done by the contractor and has to charge the transformer. (iii) If the transformer fails in these tests then the contractor has to shift the transsformer for winding /overhauling which will be measured and paid separately. (iv) Cost winding / overhauling if required shall be measured and paid separately.
Shifting the Transformer of capacity 63 to 750 KVA from existing site to another site within 3 Km distance range by Dismantling of HT and LT cable connections, jumpers and busbars including LT busbar cable boxes and closing the transformers for loading into transporting vehicle with the help of crane, transportation to another site, unloading, cable connections both HT and LT, testing and commissioning complete all as specified and as directed.
S&F in repair silica gel breather assembly complete suitable for 63 to 750 KVA transformer as per existing with breather unit and silica gel including connecting with proper necessary gaskets if necessary & removing the unserviceable breather assembly complete all as specified and as directed.
S&F in repair conservator tank assembly suitable for transformer of capacity 500 to 750 KVA as per existing and including connecting with proper necessary gaskets if necessary & removing the unserviceable Conservator tank complete all as specified and as directed.
All as per Sl item No. 12.00 but transformer of capacity 250 to 400 KVA
All as per Sl item No. 12.00 but transformer of capacity up to 200 KVA
S&F in repair gun metal drain valves suitable for transformer of capacity 500 to 750 KVA including dismantling old one complete all as specified and as directed. Make :- Upadhyay / Leader / Zoloto
All as per Sl item No.15.00 but for transformer of capacity 250 to 400 KVA
All as per Sl item No. 15.00 but for transformer of capacity up to 200 KVA
S&F in repairs off load tap changer assembly suitable for transformer of capacity 500 to 750 KVA as per existing with 7 tapping position including opening top cover, conservator etc complete all as specified and as directed.
All as per Sl item No. 18.00 but suitable for transformer of capacity up to 400 KVA
S&F in repair WTI (Winding Temperature Indicator) suitable for distribution transformer of capacity 500 to 750 KVA as per existing complete all as specified and as directed.
All as per Sl item No. 20.00 but suitable for transformer of capacity up to 400 KVA
S&F in repair LT bushings made out of porcelain alongwith bushing rod, as per existing and suitable for distribution transformer of capacity 500 to 750 KVA complete all as specified and as directed. Make:- Pactil / BHEL / Jaipuria Brothers
All as per Sl item No. 22.00 but suitable for transformer of capacity 250 to 400 KVA
All as per Sl item No. 22.00 but suitable for transformer of capacity up to 200 KVA
S&F in repair HT bushings made out of porcelain alongwith bushing rod, as per existing and suitable for distribution transformer of capacity 500 to 750 KVAcomplete all as specified and as directed. Make:- Pactil / BHEL / Jaipuria Brothers
All as per Sl item No. 25.00 but suitable for transformer of capacity 250 to 400 KVA
All as per Sl item No. 25.00 but suitable for transformer of capacity up to 200 KVA
S&F in repair OTI (Oil Temperature indicator) as per existing suitable for distribution transformers of capacity 500 to 750 KVA complete all as specified and as directed.
All as per Sl item No. 28.00 but suitable for transformer of capacity 250 to 400 KVA
All as per Sl item No. 28.00 but suitable for transformer of capacity up to 200 KVA
S&F in repair drain plug & valve of conservator tank of suitable sizes as per existing suitable for distribution transformers of capacity 500 to 750 KVA complete all as specified and as directed.
S&F in repair Oil gauge glass with gaskets as per existing suitable for distribution transformers of capacity 63 to 750 KVA complete all as specified and as directed.
M&L for preparation of old exposed painted surfaces of indoor / outdoor type transformer of capacity 500 to 750 KVA and painting the same with two coats of synthetic enamel paint including writing details of transformer on transformer plinth / base with white synthetic enamel paint on black synthetic enamel paint back ground complete & including one coat of white wash on exposed surface of transfomer plinth / base complete all as specified and as directed. Note :- Colour of paint shall be as decided by Engr-in-Charge. Make:- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
All as per Sl item No. 33.00 but for transformer of capacity 250 KVA to 400 KVA
All as per Sl item No. 33.00 but for transformer of capacity up to 200 KVA
Clearing away all bushes, small plants, grass, vegetation, saplings, shrubs, brushwood, undergrowth, roots upto root level including surface dressing n.exc 15 cm deep around and surroundings areas of E/M installations (i.e.Two Pole/ Four structures, outdoor-substation yards, pump house & Misc E/M installations etc) and removing rubbish / debris upto a distance of not less than 50 metres outside the periphery of the area under clearance complete all as directed.
Supply and laying hardcore of aggregate using 20mm graded crushed stone aggregate, deposited, spread and leveled in layers watered and rolled / rammed to a true surface in sub-station yards complete all as specified and directed. Note:- Thickness of aggregate shall be measured after compaction.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. and getting out all excavated material in soft / loose soil complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L sand cushioning with clean and dry sand in trenches for protection of UG cable and including punning down complete all as specified and directed. Note:- Punned thickness shall only be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, of size 300mmx 180mm x 40mm, laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
S&F 100 mm bore galvanised steel tubing, medium grade with necessary fittings, laid under road crossing, for cable protection complete all as specified and directed. Make - Tata / Jindal Steel / Surya Roshni Ltd. / Bhushan Power & Steel Ltd. / M/s APL Apollo Tubes Ltd
M&L cable jointing kit for 11 KV (Earthed) grade 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm for outdoor termination, heat shrink type joint complete with jointing material and accessories including taking down complete all as specified and directed. Make:- 3M / Denson / Raychem
All as per Sl. Item No. 44.00 above but for cable of size 240 to 300 Sqmm
M&L cable jointing kit for 11 KV (Earthed) grade 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm for straight through, heat shrink type joint with jointing material and accessories complete all as specified and directed. Make:- 3M / Denson / Raychem
All as per Sl. Item No. 46.00 above but for cable of size 240 to 300 Sqmm
Supply & laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, Earthed, grade cross sectional area 185 Sqmm, 3 core, laid in trenches / duct / on pole including taking down complete all as specified and directed. Make :- Havells / KEI / Polycab / Gloster / Asian Cables / Finolex
All as per Sl. Item No. 48.00 above but for cable of size 240 sqmm x 3 Core
M&L for detecting HT 11KV UG cable faults located in any stretch / depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV surge generator, fault pin point surge wave receiver, cable identification instrument , cable tracer for exact location of under ground cable routes complete all as directed. Note:- The rate quoted deemed to be inclusive of arrangement of necessary fault locator equipment, transportation of equipment& charges for service engineer.
M&L for repair and servicing of HT 11 KV two pole structure by replacing Aluminium PG clamps, GI bolts and nuts, pieces of ACSR conductor with insulation sleeve RYB of any size as jumpers including lubricating the moving parts of AB switch and cleaning of all disc and pin insulators and applying silicon compound for prevention of arcing due to dust / salt deposits over surfaces including preparation of surfaces, applying zinc chromate primer on rusted surfaces and applying one coat of aluminum paint to the entire structure complete all as specified and as directed. Note : Rate quoted shall be inclusive of two coats of white wash on exposed concrete surfaces of structure. Make of paint :- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
Servicing, Inspecting, checking, cleaning by using of blower, lubrication, greasing and carrying out preventive maintanance of RMU of capacity 11 KV, 250 / 350 MVA including calibrating the relay by conducting secondary injection tests and RMU in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. Notes: Unit rate quoted shall be deemed to include cost for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, painting of RMU panels with approved colour including lettering details all as per exisitng..
Supply & fixing in repair Self powered relay with O/C, S/C, E/F protection, having front USB port for laptop interface, LCD display,10 event records, 5 fault records, min 2 setting group and keypad for setting parameters for the relay complete suitable for RMU of capacity 630 Amp all as specified and as directed. Make:- Schneider / Siemens / L&T / ABB
S&F in repair current transformer, Ratio - 100-50/1-1A, accuracy class 1.0, burden - 2.5VA for metering and class 10P10, 2.5 VA for protectioncomplete all as specified and directed. Make :- AE / English Electric / Crompton Greaves / Areva T&D / Schneider
S&F in repair cable termination bushing suitable for upto 1 run 3 core x 185 Sq mm, XLPE cable complete all as specified and directed. Make:- Schneider / Siemens / L&T / ABB
S&F in repair cable termination cover boots, push on type suitable for RMU of capacity 630 Amp complete all as specified and directed. Make:- Schneider / Siemens / L&T / ABB
S&F in repair phase indicator lamps (Red, Yellow and blue) suitable for RMU of capacity 630 Amp complete all as specified and directed. Make:- L&T / Siemens / GE / RR Micro / BCH / Schneider
S&F in repair 11KV, 230V, AC, 1KVA control transformer suitable for RMU of capacity 630 Amp complete all as specified and directed. Make :- AE / English Electric / Crompton Greaves / Areva T&D / Schneider
S&F in repair Battery with & including battery charger, 12Ah, (I/P-230V AC, O/P - 24V DC suitable for RMU of capacity 630 Amp complete all as specified and directed. Make:- Exide / Amron / Amara raja
S&F in repair Spring charging motor suitable for RMU of capacity 630 Amp complete all as specified and directed.
M&L for taking down RMU of capacity 630 Amp, transporting to workshop from sub station (OEM Factory) including filling of SF6 gas, bringing back to site safely and re-installing, testing and commissioning the same complete all as specified and directed.
M&L for preparation of complete external surface of RMU of capacity 630 Amp & applying two coat of synthetic enamel paint complete all as specified and directed. Make:- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
Supply & filling oil with di-electric strength not less than 60 KV suitable for RMU complete all as specified and directed. Make: Apar (Power Oil) / Savita (Transol) / Asian
S&F in repair bottle neck Insulaor suitable for RMU of capacity 630 Amp complete all as specified and directed. Make:- Schneider / Siemens
S&F danger notice plate of size 25 x 20 cm & 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for HT including dismantling compete all as specified and as directed.
M&L switches air break, gang operated triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps, 11000 volts all as per clause no 19.69 of SSR part-I (2009) including taking down complete all as specified and directed. Make:- Pactil / BHEL / Jaipuria Brothers
S&F in repair drop out lift OFF HT 11 KV, 200 Amp fuse link consisting of channel iron base having 2 Nos 11 KV post type insulators in stack & 2 stack per phase complete with fuse carrier of SRBP tube with heavily tinned non ferrous metal parts and spring loaded phosphor bronze conforming to IS 9385 complete all as specified and directed. Make:- Pactil / BHEL / Jaipuria Brothers
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to earth lead of galvanised iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 connected to earthing test point including dismantling complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, Main earthing lead from earth electrode to test point upto 7.5 m length, 20 mm bore medium grade GI watering pipe, 40 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
S&F in repair lightning arresters expulsion type complete with all fittings, station class, discharge capacity 10 kilo amp suitable for 11000 volts including taking down complete all as specified and directed. Make:- Oblum / Elpro / BHEL / Areva T&D / Jaipuria Brothers
general electricals
MSN ENGINEERING WORKS
jyothi constructions
SRI SRK ENGINEERS
SRIESWARI ENTERPRISES
SRI MAHALAKSHMI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .