| 1 | 1₹20.3 LAccepted-AOC 8 CHANDIVALI STUDIO ROAD ANDHERI EAST MUMBAI MAHARASHTRA 400072 | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | 1 | Accepted-AOC SUPPLY OF EQUIPMENTS FOR MRU OF AGMC AND GBPH AGARTALA | |
| 2 | Not Admitted-Fee/PreQual/Technical P 132 P 132 KALINDI HOUSING ESTATE JESSORE ROAD KOLKATA 700089 KALINDI KOLKATA WEST BENGAL 700089 | 24 PARAGANAS NORTH | WEST BENGAL | 700089 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹35 L
EMD Value
₹1.8 L
Closing Date
30 Dec 2019, 4:00 pmClosed
Principal AGMC AND GBP Hospital
Principal OFFICE AGMC AND GBP Hospital
Procurement of 03 three equipments for Multi-Disciplinary Research Unit AGMC AND GBPH
2019_OSD_6775_1
F 13 1 15 AGMC MRU e Tender F 3 2019
Open Tender
Laboratory and scientific equipment
Turn-key
60 days
Multi-Disciplinary Research AGMC AND GBP Hospital
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
Principal AGMC AND GBP Hospital
₹1.8 L
Yes
3 Apr 2020
27 Nov 2019
31 Dec 2019
27 Nov 2019
30 Dec 2019
27 Nov 2019
items
-20 degree Centigrade Freezer • System should have temperature up to -25 degree C. • Should have built in condenser for flow low energy consumption. • No dust. • Low noise. • Combination of pull out drawers and fast freeze shelves. • Control panel at the top of the cabinet with thermometer or temperature warning light. • Thermostat. • Fast freeze button and lamp. • Mains warning lamp. • Single door. • CFC free heavy duty compressor. • Should be provided with 6-8 shelves. • Gross capacity: 345Lt.
Automated blood cell counter (3 parts diff.) • Three (3) parts differential analysis. • Minimum 20 parameters. • Hb estimation should be cyanide free. • Throughput – minimum 60 samples/hr. • Sampling method: Open tube/cuvette system with automated sample rotor. • Sample volume: >Whole Blood: upto 20µl. >Pre-diluted: upto 20µl. • Analysis mode: Whole Blood and Pre-Diluted- both. • Barcode reading facility. • Database storage capacity: more than 30,000 results combined with histogram. • Quality control: 500 files with L-J graph and X-Bar Analysis. • Int. Quality assurance programme. • Built- in Printer. • Result display on colour LCD screen. • Facility for Serial port & LAN service. 4USB (for connecting external devices including external printer) + 1LAN Port (HL7, TCP/IP; LIS connectivity)
Auto Analyser • It should be Automated, Discrete, Random Access; patient prioritized Clinical chemistry Analyzer capable of performing biochemistry and immunoturbidimetry assays. • It should be a floor model. • The throughput should be at least 400 tests/hr photometric tests for a cycle of 9 seconds and 640 tests/hr with ISE (optional). • It should have more than 52 on line chemistries. • It should not have any limit on number of programmable Chemistries, Profiles and Calculation Item. • It should accept Linear, Non-Linear, Multi Point Calibration. • Sample disk should accept minimum 75 samples at a time. All the positions on the sample disk should accept STAT samples, blanks, controls, standards and ISE solutions. • It should accept 5 ml, 7 ml, 10 ml and sample cups for keeping samples. • The sample pipetting should be between 2 – 70µl in steps of 0.2 µl. • It should have a sample probe & two separate reagent probes for R1 & R2. • The reagent tray should be cooled at 4degree C to 12degree C and should have 56 reagent bottles. It should accept 20 ml, 50 ml bottles and 5 ml adapters. • Display of Reaction Cuvette temperature and Reagent Tray temperature should be available on Screen. • Biohazard waste should be collected in a separate container. • System should be capable of performing 2 Reagent Chemistries. • It should have fixed barcode reader for both reagents and samples (Optional). • Reagent pipetting should be between 10 – 300µl in steps of 1 µl. • The reaction cuvettes should be 72 permanent hard glass cuvettes maintained at 37 degree C ± 0.2 degree. • On line Reaction Graph should be displayed on the screen and all the reaction graphs should be stored in the memory. • The minimum reading volume should be 180 µl. • It should have on board laundry for washing of the cuvettes. • Photometer should consist of 12 wavelengths in the range 340 to 750 nm. It should be capable of doing Monochromatic and Bichromatic measurements. • Light source should be pre aligned Halogen Lamp (12 V/20 W) • Absorbance range should be 0.0 – 3.0 Abs. • It should have extensive Q. C. program. Should show daily and monthly Levy Jennings Chart and Twin Plot. • It should have facility of auto re-run, auto dilution of sample facility, • Facility of Skipping of dirty cuvettes should be available. • The mixing stirrer should have user defined variable speed (minimum 3 speeds). • Probe should have Vertical obstruction Detection.Power Requirement should be AC 110 V ± 10% Hz and 60 ± 1 Hz or AC 220 V ± 10% Hz and 50±1 Hz.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .