Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.0 LAccepted-AOC CHIRAPPATTU HOUSE THALACODE MULANTHURUTHY PIN 682314 | MULANTHURUTHY | ERNAKULAM | KERALA | 682314 | ₹70.0 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹71.8 LRejected-Finance 42 I 63 PALAMATTATHIL SOUTH KALAMASSERY SANTHI NAGAR RAJAGIRI P O ERNAKULAM KERALA PIN 683104 | ERNAKULAM | ERNAKULAM | KERALA | 683104 | ₹71.8 L | L2 | Rejected-Finance L2 bidder |
| Sl No | Description | Qty | Unit | PRIMETECH ENGINEERING L2 | Taiju Kuriachan L1 |
|---|---|---|---|---|---|
| 1.00Ground preparation, Fencing and Kerb | |||||
| 1.01 | OD227783/2025-2026 : Filling with contractor's own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering and rolling every 3rd and topmost layer with power roller of minimum 8 tonnes, for all leads including all lifts involved as per the direction of site Engineer- in-charge. (Based on DSR Item No. 50.2.26.1 and 2.2.1) | 315 | cum | 424.2 ₹1.3 L | 414 ₹1.3 L |
| 1.02 | 2.9.1 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock | 70.07 | cum | 618.1 ₹43,309.03 | 603 ₹42,251 |
| 1.03 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) | 11.36 | cum | 7,468.7 ₹84,874.31 | 7,297 ₹82,923.11 |
| 1.04 | 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) | 34.99 | cum | 9,875.1 ₹3.5 L | 9,648 ₹3.4 L |
| 1.05 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete | 112.64 | sqm | 363.6 ₹40,955.90 | 355 ₹39,987.20 |
| 1.06 | 5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. | 130 | sqm | 790.5 ₹1.0 L | 771 ₹1.0 L |
| 1.07 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 3,148.92 | kilogram | 105.9 ₹3.3 L | 103 ₹3.2 L |
| 1.08 | OD218634/2025-2026 : Steel work for fencing with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete (Based on DSR 50.10.2) | 7,013.04 | kg | 174 ₹12.2 L | 169 ₹11.9 L |
| 1.09 | 16.70.1 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I. wire of dia 4 mm | 195 | sqm | 1,014.7 ₹2.0 L | 990 ₹1.9 L |
Tender Value
₹76.3 L
EMD Value
₹50,000
Closing Date
17 Jan 2026, 3:00 pmClosed
The Chief Engineer, Sports Kerala Foundation
Jimmy George Indoor Stadium, Vellayambalam, Thiruvananthapuram
Ground preparation, Fencing and Kerb, Synthetic Football Turf (45mx20m), Name board and Inauguration Stone and Electrification Works
2026_SKF_826323_1
425/SKF/CE/2025-26
Open Tender
Civil Works - Others
180 days
Ernakulam
Please refer tender document
13 documents required · 13 mandatory
₹2,950
₹50,000
16 Mar 2026
7 Jan 2026
19 Jan 2026
7 Jan 2026
17 Jan 2026
7 Jan 2026
Amount
Ground preparation, Fencing and Kerb
OD227783/2025-2026 : Filling with contractor's own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering and rolling every 3rd and topmost layer with power roller of minimum 8 tonnes, for all leads including all lifts involved as per the direction of site Engineer- in-charge. (Based on DSR Item No. 50.2.26.1 and 2.2.1)
2.9.1 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
OD218634/2025-2026 : Steel work for fencing with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete (Based on DSR 50.10.2)
16.70.1 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I. wire of dia 4 mm
OD218636/2025-2026 : Supply and Installation of approved quality 2mm thick UV Stabilized Nylon net of Mesh size not greater than 50mm in existing GI poles including all charges as per the direction of Engineer in charge. (rate based on DAR 26.81)
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
OD227973/2025-2026 : Providing and laying of Interlock concrete block pavements having thickness 60mm (M30) as per drawings and technical specification clause 1504 confirming to IS 15658 and laid in required colour and pattern over and including 50mm thick compacted bed of 6mm metal including edge concreting for 300mm width and150mm depth with CC M35 (@0.045 m3/m). (CTE observed Data no. 6.1)
Synthetic Football Turf (45mx20m)
OD218647/2025-2026 : Providing and fixing PVC pipes with 5 mm dia perforations, minimum 125 perforations per running metre, in trenches at required slope, as per specifications etc. complete including the cost of all materials, labour etc. and as directed by the Engineer-in-charge. The rate includes cost of all materials, covering the pipe with Geo Textile Cloth, labour charges for trenching carriage of surplus earth to a lead of 50m etc complete. including jointing of pipes with one step PVC solvent cement, etc. complete as per the direction of Engineer-in-Charge. 150 mm dia 6 Kgf/cm2.
OD218650/2025-2026 : Providing and laying of 20mm downgraded metal (Coarse rubble granite Stone) of approved quality as filter media around the drainage pipes in the sides of trench as per the directions of Engineer-in-charge. Rate inclusive of all materials, transportation and labour charges complete.
OD218644/2025-2026 : Providing, laying and spreading of compacted fill with 40mm metal (Coarse Rubble Granite Stone) to form a contour and elevations in uniform thickness, rolling with 3 wheeled road /vibratory roller 8-10 tonne capacity in stages to proper grade and camber, as per Drawings. Rate inclusive of all materials, transportation and labour charges complete. The work has to be completed as per detailed specifications and or as approved by Engineer-in-charge. Quantity measured based on the stack measurement and the stack shall be of standard dimensions.
OD218648/2025-2026 : Providing, laying and spreading of compacted fill with 20mm metal (Coarse Rubble Granite Stone) to form a contour and elevations in uniform thickness, rolling with 3 wheeled road /vibratory roller 8-10 tonne capacity in stages to proper grade and camber, as per Drawings. Rate inclusive of all materials, transportation and labour charges complete. The work has to be completed as per detailed specifications and or as approved by Engineer-in-charge. Quantity measured based on the stack measurement and the stack shall be of standard dimensions.
OD218646/2025-2026 : Providing ,laying and spreading of compacted fill with 10mm metal (Coarse Rubble Granite Stone) to form a contour and elevations in uniform thickness, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, as per Drawings. Rate inclusive of all materials, transportation and labour charges complete. The work has to be completed as per detailed specifications and or as approved by Engineer-in-charge
OD218645/2025-2026 : Supply and Laying 120 GSM Geotextile Membrane as per direction of Engineer - in - Charges.
OD218649/2025-2026 : Supply and Installation FIFA approved quality Synthetic Football Turf of Pile height 50 mm with PU backing, Stabilizing infill of Quartz sand 25 kg/sqm and Performance infill Black SBR Rubber 8 kg/sqm as per the direction of officer in charge. A test certificate of compliance to FIFA specification is mandatory during physical inspection at site along with test report on material. Design, receive material, installation, testing and commissioning of synthetic surface for football including, laying, jointing, fixing in position to subbase, including all according to methodology and drawings and specifications, approved by FIFA including line marking to FIFA specification all complete. The complete installation should be to FIFA approved international standards.
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2
OD218643/2025-2026 : Supply and installing Movable type premium quality outdoor Football Goal Post of size 24x8 feet made with heavy duty MS Pipe of size 4" dia for main frame with supports Back frame with PU finishing including all fittings such as premium quality Nylon net, Hooks, solid wheels etc. for elevens court.
Name board and Inauguration Stone
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
4.3.1 : Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
OD218638/2025-2026 : Steel work for Name board post with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete (Rate based on CPWD 50.10.2)
10.25.2 : Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.71 : Lettering with black Japan pint of approved brand and manufacture
OD218639/2025-2026 : Providing and fixing 18 mm thick gang saw cut, mirror polished, pre-moulded and pre polished, machine cut for inauguration granite stone of required size, approved shade, colour and texture laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) joint treated with white cement, mixed with matching pigment, epoxy touchups including rubbing, curing etc. complete at all levels. Area of slab over 0.50 sqm
16.21 : Engraving letters in hard stone
Electrification Works
90.15.4.11 : Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD218640/2025-2026 : SKF OD: Supply, installation, testing and commissioning of Outdoor Type Floor Mounting KSEB metering panel, suitable for accommodating 3 Phase Energy meter and consisting of 3 nos. of 40 A/63A cutout with HRC fuse( or as per KSEB) , neutral link in separate chamber, inter connections, provision for CT chamber, 63 A SFU-1 no and separate cabin shall be provided in outdoor panel to accommodate VDB/DB(Min. 6Way) as per the requirement etc. as required, and including necessary supports of floor or wall mounting as required, and the panel fabricated out of 14 SWG CRCA sheet with lockable door with sealing facility having glass window for energy meter, sealing facility for KSEB, top canopy and necessary overhang, undergone seven tank process ,powder coated finish and all mounting accessories as required, The firm should have CPRI Certification.
90.12.1.40 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 10 sq mm
90.12.1.41 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 16 sq mm
90.6.5.12 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
OD218642/2025-2026 : Supply and fixing SINTEX Box (150mmx150mmx100mm) including connector, MCB Rail and neutral links for giving connections including all accessories complete as required
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.10.1 : Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.4 : Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
OD218641/2025-2026 : SKF OD : Earthing with G.I. earth pipe 2.5 meter long, 40 mm dia including accessories, with providing masonry enclosure with cover plate / FRP Earth Pit Chamber. ( but without charcoal/ coke and salt ) etc as required
90.16.1.2 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
PRIMETECH ENGINEERING (BID ID -2459817)
Bidder Name
Taiju Kuriachan
PRIMETECH ENGINEERING
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1386048.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
Tenderdoc.pdf
Tender Documents • 1.39 MB
BOQ_1386048.xls
BOQ • 0.31 MB
DWG.pdf
Other Document • 1.94 MB
Download all tender documents and submit your bid