Ex.Eng (O&M) Valsad Rural Division
Erection & Maintenance and Labour works for Laying, testing & commissioning of 11/22 KV underground XLPE cable (XLPE cable to be supplied by DGVCL), with cable End termination & straight through jointing kits (to be supplied by contractor) for Various feeder under jurisdiction of Bilimora Town sub division under Various Scheme under Valsad Rural Division.
307454
DGVCL/VALSAD-R DO/E-TENDER/2026-27/21
Open
Miscellaneous Works
Works
Valsad
8 documents required · 8 mandatory
₹1,180
DGVCL, Payable @ Valsad
₹40,000
21 May 2026
21 May 2026
21 May 2026
1 Jun 2026
21 May 2026
Item Code Item Unit FY 2024-25
HT TAPPING FROM THE EXISTING POLE INCLUDING
FIXING OF CROSS ARMS, CLAMPS ANTI-CLIMBING
DEVICES, DANGER BOARD, INSULATORS ETC.
1 9926000001 COMPLETE AND PAINTING OF FABRICATED No.
MATERIALS AND NUMBERING COMPLETE WITH COST
OF PAINTS AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF PSC POLES OF 8 *200 KG INCLUDING
EXCAVATION OF PIT AND REFILLING OF EARTH,
FIXING OFCROSS ARMS, TOP FITTING CLAMPS ANTI-
CLIMBING DEVICES, INSULATORS ETC. COMPLETE
AND PAINTING OF FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
ERECTION OF STEEL POLES OF 9 TO 11 METERS
INCLUDING EXCAVATION OF PIT AND REFILLING OF
EARTH, FIXING OFCROSS ARMS, TOP FITTING CLAMPS
3 9926000003 ANTI-CLIMBING DEVICES, DANGER BOARD, No.
INSULATORS ETC. COMPLETE AND PAINTING OF
STEEL POLE, FABRICATED MATERIALS USED ON THE
POLEAND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
ERECTION OF STEEL POLE OF 13 METERS FOR
RAILWAY CROSSING ON BG/MG/NG LINE FOR
0.400/11/22KV OVERHEAD LINES I.E INCLUDING
EXCAVATION OF PIT & REFILLING OF EARTH, FIXING
CROSS ARMS, TOP FITTING CLAMPS,ANTI-CLIMBING
4 9926000004 DEVICES DANGER BOARD, INSULATORS ETC. No.
COMPLETE AND PAINTING OF STEEL POLES,
FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COSTOF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF
METERS 200 KG PSC POLES INCLUDING EXCAVATION
OF PITS & REFILLING OF EARTHING, FIXING OF
CHANNELS, SUPPORTING ANGLES,CLAMPS, ANTI-
CLIMBING DEVICES DANGER BOARDS,INSULATORS
ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING
WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SETS AND EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE OF 9 TO
METERS.STEEL POLE INCLUDING EXCAVATION OF
PITS & REFILLING OFEARTH, FIXING OF CHANNELS,
SUPPORTING ANGLES, CLAMPS,ANTI-CLIMBING
DEVICES DANGER BOARDS, INSULATORS
ETC.COMPLETE & PAINTING OF POLES,FABRICATED
MATERIALSUSED ON THE POLES AND NUMBERING
WITH COST OF PAINTSAS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SET AND EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH
MOUNTING OF AB SWITCH, HG FUSES OF 8 MTRS
KG PSC POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH,FIXING OF CHANNELS
SUPPORTING ANGLES, CLAMPS, ANTI-CLIMBING
7 9926000007 DEVICES, DANGER BOARDS, INSULATORS,DOFUSES No.
ETC. COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING
WITH COSTOF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDINGOF ERECTION OF
GUY SET AND EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH
MOUNTING OF AB SWITCH,HG FUSES, 9 TO
METERS STEEL POLES INCLUDING EXCAVATION OF
PITS AND REFILLING OF EARTH, FIXING OFCHANNEL,
SUPPORTING ANGLES, CLAMPS, ANTI-CLIMBING
DEVICES , DANGER BOARDS, INSULATORS, ETC.
COMPLETE AND PAINTING OF POLES FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING
WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SET AND EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURES WITH
MOUNTING OFAB SWITCH, HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX. OF 8 METER,200KG PSC POLE
METERS POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF TRANSFORMERS
FROMSTORES TO SITE, FIXING OF CHANNELS,
SUPPORTING ANGLES,BRACINGS CROSS ARMS
CLAMPS, ANTICLIMBING DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND
PAINTING OF FABRICATED MATERIALS USEDON THE
POLES AND NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH
MOUNTING OF AB SWITCH,HG FUSES
TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX 9 TO 11 METERS STEEL POLES
INCLUDING EXCAVATION OF PITS & REFILLING OF
EARTH CARTING OF TRANSFORMERS FROM STORE TO
SITE, FIXINGOF CHANNELS SUPPORTING ANGLES,
BRACING, CROSS ARMS,CLAMPS, ANTICLIMBING
DEVICES, DANGER BOARDS,CONDUCTOR AND CABLE
WIRING ETC. COMPLETE AND PAINTING OF POLES
FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTIONS OF GUY SETS AND
ERECTION OF GUY SET INCLUDING EXCAVATION OF
PITS & REFILLING OF EARTH AS PER STANDARD
SPECIFICATION WITH STAY CLAMPS, STAY WIRE,
ANCHOR ROD, TURN BUCKLE, EYEBOLT, GUY
INSULATOR, CEMENT CONCRETE BLOCK ETC. BUT
EXCLUDING CONCRETING.
CONCRETING OF POLES, GUYS, ETC. INCLUDING
COST OF CEMENT SAND METAL (1:2:4) AND WATER
ETC. AS PER STANDARD SPECIFICATION.(cement
Should be 53 grade) used for Concreting.
ERECTION OF COIL TYPE EARTHING INCLUDING COST
OF COAL,SALT ETC. BUT WITHOUT COST OF GI WIRE
AS PER STANDARD SPECIFICATION(20kg solt+20kg
ERECTION OF GI PIPE/CI PLATE TYPE EARTHING
INCLUDINGCOST OF COAL SALT ETC. BUT WITHOUT
COST OF PIPE/GIPLATE GI WIRE AS PER STANDARD
SPECIFICATION.(20kg solt+20kg coal)
ERECTION OF STREET LIGHT FIXTURE COMPLETE
WITH CLAMPS, BRASS NIPPLE, BRASS HOLDER TECK
15 9926000015 WOOD BUSH,REFLECTORS FUSE, WIRING ETC. AS PER No.
STANDARD SPECIFICATION BUT EXCLUDING COST OF
STRINGING OF(30mm2)ACSR/34MM@,55MM2 AAA
CONDUCTOR for ALL TYPE OF CONDUCTOR (EXCEPT ONE
16 9926000016 DOG CONDUCTOR) FOR 11/22KV & LT LINES COND
INCLUDING FIXING OF INSULATORS, BINDING PER KM
STRINGING OF GI WIRE 8 SWG INCLUDING BINDING
PROVIDING SINGLE PHASE SERVICE CONNECTION
WITH PVC 2.5/4MM2 TWIN CORE CABLE FROM
TERMINAL POLE TO METERING POINT INCLUDING
FIXING OF METER WITH METER EARTHING COMPLETE
WORK AS PER STANDARD SPECIFICATION BUT
EXCLUDING COST OF MATERIALS.
PROVIDING THREE PHASE 4 WIRE SERVICE
CONNECTION WITH PVC 4MM2/10MM2 FOUR CORE
CABLE FROM TERMINAL POLE TO METERING POINT
19 9926000019 INCLUDING FIXING OF METER WITH METER No.
EARTHING COMPLETE WORK AS PER STANDARD
SPECIFICATION BUT EXCLUDING COST OF
ADDITIONAL COST FOR EXCAVATION OF PIT IN HARD
ROCK AREA FOR ERECTION OF POLE/ GUY ETC. AS
PER STANDARD SPECIFICATION OVER & ABOVE
20 9926000020 NORMAL COST COVERED AGAINST EXCAVATION OF No.
PIT UNDER NORMAL SOIL FOR ERECTION OF
POLE,GUY, DOUBLE POLE STRUCTURE EARTHING
WITH THE APPROVAL OF SUPDT.ENGINEER.
PROVIDING GUARDING TO HT LINE ON ROAD/ RAIL
PROVIDING GUARDING OF LT LINES ON ROAD/RAIL
23 9926000023 LT LINE TAPPING- SINGLE PHASE No.
24 9926000024 LT LINE TAPPING- THREE PHASE No.
Stringing/LAYING OF OVER HEAD LT CABLE FOR ROAD
25 9926000025 CROSSING,HT LINE CROSSING AND TELEPHONE LINE No.
CROSSING ETC.(PER SPAN)
ERECTION OF SINGLE POLE STRUCTURES WITH , HG
FUSES,TRANSFORMERS, LIGHTENING ARRESTOR,
DISTRIBUTION BOX. ON 8 METERS 200 KGAND PSC
POLE INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF TRANSFORMERS
FROM STORES TO SITE, FIXING OF CHANNELS,
26 9926000026 SUPPORTING ANGLES,BRACINGS CROSS ARMS No.
CLAMPS, ANTICLIMBING DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED ON THE
POLE AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OFGUY SETS AND EARTHING.
ERECTION OF SINGLE POLE STRUCTURES WITH
MOUNTING OFAB SWITCH , HG
FUSES,TRANSFORMERS, LIGHTENINGARRESTOR,
DISTRIBUTION BOX. ON 9 to 11 METERS RSJ
POLE INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF TRANSFORMERS
FROM STORES TO SITE, FIXING OF CHANNELS,
SUPPORTING ANGLES,BRACINGS CROSS ARMS
CLAMPS, ANTICLIMBING DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED ON THE
POLE AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OFGUY SETS AND EARTHING.
ERECTION OF PSC POLES OF 10 *270 KG INCLUDING
EXCAVATION OF PIT AND REFILLING OF EARTH,
FIXING OF CROSS ARMS, TOP FITTING CLAMPS ANTI-
CLIMBING DEVICES, INSULATORS ETC. COMPLETE
AND PAINTING OF FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF
METERS 270 KG PSC POLES INCLUDING EXCAVATION
OF PITS & REFILLING OF EARTHING, FIXING OF
CHANNELS, SUPPORTING ANGLES,CLAMPS, ANTI-
CLIMBING DEVICES DANGER BOARDS,INSULATORS
ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING
WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SETS AND EARTHING.(WITHOUT AB SWITCH)
STRINGING OF 100MM2 ACSR/100MM2 AAAC ONE
30 9926000030 CONDUCTOR FOR 11/22KV & LT LINES INCLUDING COND
FIXING OFINSULATORS, BINDING JUMPERING ETC. PER KM
STRINGING OF DOG CONDUCTOR FOR 11/22KV & HT ONE
31 9926000031 LINES INCLUDING FIXING OF INSULATORS, BINDING COND
JUMPERING ETC. PER KM
ERECTION OF DOUBLE POLE STRUCTURES WITH
MOUNTING OF AB SWITCH, HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX. OF 10 METERS 270 KGAND
PSC POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF TRANSFORMERS
FROMSTORES TO SITE, FIXING OF CHANNELS,
SUPPORTING ANGLES,BRACINGS CROSS ARMS
CLAMPS, ANTI-CLIMBING DEVICES,DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SETS AND EARTHING.
DISMENTALLING OF 8 MTR PSC POLE WITH
CREDITING OF FABRICATION AT STORE & STACKING
OF POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
DISMENTALLING OF 10 MTR PSC POLE WITH
CREDITING OF FABRICATION AT STORE & STACKING
OF POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR
PSC POLE) (WITH TRANSFORMER) WITH CREDITING
35 9926000035 OF FABRICATION & TRANSFORMER AT STORE & No.
STACKING OF POLE SAFELY ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR
PSC POLE) (WITHOUT TRANSFORMER) WITH
36 9926000036 CREDITING OF FABRICATION AT STORE & STACKING No.
OF POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
STRINGING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, LT SHACKLE INSULATOR ETC. FOR
FIXING OF MESSENGER WIRE AND TO PROVIDE
SERVICE CONNECTION ON AERIAL BUNCH CABLE BY
INSULATED PIERCEING CONNECTORS THROUGH
SERVICE CONNECTION BOX COMPLETE AS REQUIRED
& DIRECTED BY ENGINEER IN CHARGE.
38 9926000038 STRINGING OF LT ABC OF 3*50 SQ MM +1*25 SQ KM
MM+1*35 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION /
TENSION CLAMP, FIXING OF CROSS ARM, LT SHACKLE
INSULATOR ETC. FOR FIXING OF MESSENGER WIRE
AND TO PROVIDE SERVICE CONNECTION ON AERIAL
BUNCH CABLE BY INSULATED PIERCEING
CONNECTORS THROUGH SERVICE CONNECTION BOX
COMPLETE AS REQUIRED & DIRECTED BY ENGINEER
STRINGING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, BINDING TO PIN INSULATOR,PREPARING
SHACKLE POINT,JUMPERS ETC. AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE
STRINGING OF 22 KV ABC OF 3*70 SQ MM +95 SQ
MM INCLUDING FITTING OF ALL ACESSARIES I.E.
SPECIAL DESIGN SUSPENSION / TENSION CLAMP,
40 9926000040 FIXING OF CROSS ARM, BINDING TO PIN KM
INSULATOR,PREPARING SHACKLE POINT,JUMPERS
ETC. AS REQUIRED AND DIRECTED BY ENGINEER IN
STRINGING OF LT ABC OF 2*50 SQ MM +1*25 SQ
MM+ 35 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION /
TENSION CLAMP, FIXING OF CROSS ARM, LT SHACKLE
INSULATOR ETC. FOR FIXING OF MESSENGER WIRE
AND TO PROVIDE SERVICE CONNECTION ON AERIAL
BUNCH CABLE BY INSULATED PIERCEING
CONNECTORS THROUGH SERVICE CONNECTION BOX
COMPLETE AS REQUIRED & DIRECTED BY ENGINEER
DISMENTALING OF RSJ (9/11 METER) POLE AND
CREDITING THE OLD MATERIAL TO STORE
DISMENTALING OF TRANSFORMER CENTER ON
10MTR,270KG PSC POLE(WITHOUT TRANSFORMER)
43 9926000043 WITH CREDITING OF FABRICATION AT STORE AND No.
STACKING OF POLE SAFELY ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE
DISMENTALING OF TRANSFORMER CENTER ON
10MTR,270KG PSC POLE(WITH TRANSFORMER) WITH
44 9926000044 CREDITING OF FABRICATION AT STORE AND No.
STACKING OF POLE SAFELY ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE
DISMENTLING OF 11KV ABC OF 3*95 SQ MM +80 SQ
45 9926000045 MM AND CREDITING FITTING OF ALL ACESSARIES KM
AND FABRICATION TO DEPARTMENTAL STORE
DISMENTLING OF 22 KV ABC OF 3*70 SQ MM +95 SQ
46 9926000046 MM AND CREDITING FITTING OF ALL ACESSARIES KM
AND FABRICATION TO DEPARTMENTAL STORE
DISMENTALING OF LT ABC OF 1*35 SQ MM + 1*25 SQ
MM AND CREDITING FITTING OF ALL ACESSARIES TO
DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 3*50 SQ MM +1*25 SQ
MM+1*35 SQ MM AND CREDITING FITTING OF ALL
ACESSARIES TO DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 2*50 SQ MM +1*25 SQ
MM+ 35 SQ MM AND CREDITING FITTING OF ALL
ACESSARIES TO DEPARTMENTAL STORE.
RESTRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT
DOG CONDUCTOR) FOR 11/22KV & LT LINES
INCLUDING FIXING OF INSULATORS, BINDING
RESTRINGING OF DOG CONDUCTOR FOR 11/22KV HT
LINES INCLUDING , BINDING JUMPERING ETC.
LABOUR CHARGE FOR THE INSTALLATION OF NEW
DTR METER. (METER WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR THE REPLACEMENT OF DTR
53 9926000053 METER AND OLD METER SHOULD BE CREDITED TO No.
SDN STORE. (METER WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR PROVIDING CT COIL FOR DTR
54 9926000054 METER CONNECTION. (CT COIL WILL BE PROVIDED PER CT
LABOUR CHARGE FOR REPLACEMENT OF CT COIL FOR
DTR METER CONNECTION AND OLD CT SHOULD BE
CREDITED TO SDN STORE. (CT COIL WILL BE
PROVIDED BY DGVCL)
LABOUR CHARGE FOR FIXING OF MMB FOR DTR
METER (MMB WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT OF DTR METER
BOX. (METER WILL BE PROVIDED BY DGVCL)
PROVIDING / REPLACEMENT OF 1.5 SQ MM 10 CORE
58 9926000058 COPPER CABLE 3.5 METER (CABLE TO BE PROVIDED No.
LABOUR CHARGE FOR PROVIDING/RECONNECTION OF
59 9926000059 TERMINAL CONNECTION WITH PROPER SIZE OF
LUGS. (LUGS COST IS BORNE BY AGENCY)
LABOUR CHARGE FOR THE SPOT READING OF DTR
60 9926000060 METER WITH DETAIL SURVEY OF DEFECT IF ANY. A
DULY SIGN COPY BY SURVEYOR PERSON OF AGENCY
IN PRO-FORMA REPORT SHOULD BE SUBMITTED TO
SDN OFFICE.(* ONLY IF ALL PARAMETER OF
VOLTAGE, CURRENT & LOAD AS SHOWN IN PER-
FORMA IS FILLED) AS PER THE INSTRUCTION OF
ENGINEER IN-CHARGE.
LABOUR CHARGE FOR THE SPOT READING OF DTR
METER WITH DETAIL SURVEY OF DEFECT IF ANY. A
DULY SIGN COPY BY SURVEYOR PERSON OF AGENCY
61 9926000061 IN PRO-FORMA REPORT SHOULD BE SUBMITTED TO
SDN OFFICE. (DULY FILL PER-FORMA IN FAULT
CONDITION IN WHICH READING PARAMETER IS NOT
SHOWN IN METER)
INSTALLATION OF DTR METER INCLUDING METER
BOX, PROVIDING & FIXING OF 1.5SQ MM SINGLE
STRAND 10 CORE ARMOURED COPPER CABLE
(3.5METER), TERMINATION IN METER & COIL
ETC.(METER, METER BOX, C.T./P.T. COIL WILL BE
PROVIDED BY DGVCL)
INSTALLATION OF DTR METER INCLUDING METER
BOX, TERMINATION IN METER & COIL ETC.
(WITHOUT 10CORE COPPER CABLE) (METER, METER
BOX, C.T./P.T. COIL WILL BE PROVIDED BY DGVCL)
Binding of messanger Conductorat with a distance not
more than 0.75 mtr with 6 turns minimum on XLPE
Cable with single strand binding wire (including cost of
Supply and Installation of 11/22 kV Distribution
Transformers HT Terminal protector (UV Resistance) PER
with using 95/120/150 sq.mm long barrel aluminum SET
lug. (1Set = 3 Nos i.e. on R, Y, B)
Supply & Installation of HT EPR Tap on 11/22 kV
Distribution Transformer with replacement of bare
conductor by HT ABC conductor (DO bottom side to PER
transformer) after removal of semi conductor by HT SET
ABC (6 inch both side). HT ABC to be supplied by
DGVCL. (1Set = 3 Nos i.e. on R, Y, B)
Supply, Installation, Testing and Commissioning of
Maintenance Free, Ready Capsule, Pipe-In-Cage (Pic)
67 9926000088 Type, Earth Electrodes for HT Feeder Pole Having 2000 NO
mm Electrode Length as per the Tender Specifications
and Drawing. (All Materials Will Be Supplied By Agency)
Supply, Installation, Testing and Commissioning of
Maintenance Free, Ready Capsule, Pipe-In-Cage (Pic)
68 9926000089 Type, Earth Electrodes for HT Feeder Pole Having 3000 NO
mm Electrode Length as per the Tender Specifications
And Drawing. (All Materials Will Be Supplied By Agency)
Supply and Installation of 25 X 3 mm GI Strip having
hot dip- galvanized-zinc coating of 80-100 microns
without any joints or welding. Both the end of the GI
strip should be connected with GI nut bolts and
required fabrication work for giving separate earthing
(1) Neutral of the transformer
(2) MS structures of the transformer center
(Approximately 25 meter GI strip per transformer
- as per requirement and instruction of Engineer
in- charge) (All Materials will be supplied by Agency)
Supply and Installation of uPVC standard make Pipe of
1.25" diameter for covering GI strip with UV protected
Cable Ties of 550 X 7.6 mm size to bind with pole
face(Approximately 25 meter uPVC pipe for GI strip
covering per transformer centre -as per requirement
and instruction of Engineer in-charge.
Supply & fixing of upto 33 kV Conductor sleeve for
Busbar to Drop out Fuse and Drop out fuse to
71 9926000093 Transformer H.T. including Busbar (12 mm sleeve) as Per TC
per technical specification. (All Materials will be
supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleeve for
Busbar to Drop out Fuse and Drop out fuse to
72 9926000100 Transformer H.T. without Busbar (12 mm sleeve) as Per TC
per technical specification. (All Materials will be
supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleeve for
Busbar to Drop out Fuse and Drop out fuse to
73 9926000094 Transformer H.T. including Busbar(15 mm sleeve) as Per TC
per technical specification. (All Materials will be
supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleeve for
Busbar to Drop out Fuse and Drop out fuse to
74 9926000101 Transformer H.T. without Busbar(15 mm sleeve) as per Per TC
technical specification. (All Materials will be supplied by
Supply & fixing of Disc type Red Color FRP(Non-
flammable) material with Weather resistant, Non-
75 9926000095 conductive bird guard OD=300 MM, ID=33 MM, Width NO
=1.25 MM, one side cut from ID to OD. (All Materials
will be supplied by Agency)
Providing and fixing of LT Terminal protectors i.e. Re-
useable boot (LT Side 1.1 kV) including LT (1.1 kV)
insulating taps. All live part at LT side shall be covered
with fixing of LT insulating taps.
77 Nylon Net around Transformer Center
77.1 9926000097 Nylon Net (12 * 15 ft) Per Net
77.2 9926000098 Nylon Dori Per TC
Labour charge for fitting Nylon Net (All fabricated
77.3 9926000099 material for fitting nylon net shall be provided by Per TC
-::- SCHEDULE – ‘B 2’: FOR MAINTENANCE -::-
Item Code Details of works Unit FY 2024-25
(A) LINE MAINTENANCE
1 9924000001 Cutting of Tree branches surounding HT/LT line
Replacement of old jumpers & providing new double
2 9924000002 jumpers with 8" binding [D Type] & capsuling with No.
3 9924000005 Support pole for Stay PSC/STP/RSJ No.
4 9924000006 Pin binding of conductor 11/22kv Pin insulator No.
Pin binding of conductor 11/22kv Pin insulator per pole
in costle area with cleaning .
6 9924000008 Pin binding of conductor LT shakel insulator No.
7 9924000009 Replacement of one/both disc.insulator at strain pole No.
8 9924000010 Replacement of LT shackle insulator at cut point No.
9 9924000011 Refixing of V cross Arm No.
Replacement of V cross Arm (With Transportation &
11 9924000013 Refixing of Top fitting in proper position No.
12 9924000014 Replacement of Top fitting No.
13 9924000015 Replacement of LT cross Arm No.
Providing DO fuse on DP with carting &
jumpuring(ONE DO FUSE)
Numburing of pole with paint by preparing back
15 9924000017 ground of one colour and have lettering(height 3" * No.
width 0.5") using stensil
16 9924000018 Fixing of MMB(1PH.) at consumer end No.
17 9924000019 Fixing of MMB(3PH.) at consumer end No.
18 9924000020 Replacement of (1ph.) meter for Urban area No.
19 9924000021 Replacement of (1ph.) meter for Rural area No.
painting consumer no. on MMB (Urban) (with letter
size height 40mm* width 8mm)
painting consumer no. on MMB (Rural) (with letter
size height 40mm* width 8mm)
22 9924000024 Replacement of deteriorated Single phase Service line No.
Fixing of new dist. Box with complete wiring including
clamps,nut bolts etc.
Reparing of guarding involving reshaping of bearer
wire cross lacing binding etc.
Painting of steel fabricated material of RSJ DO DP
structure with paint
Painting of steel fabricated material of RSJ pole
mounted transformer double pole structure with paint
Painting of steel fabricated material of RSJ single pole
painting of steel fabricated material of PSC Single pole
(HT line) with paint
painting of steel fabricated material of PSC DO DP
double pole with paint
painting of steel fabricated material of PSC double
pole at pole mounted transformer with paint
31 9924000033 Providing line seperater single phase No.
32 9924000034 Providing line seperater three phase No.
Replacement / Providing of stay insulator along with
adjustment of tension in stay wire
Replacement of deteriorated /providing LT dist. Box
34 9924000036 with new up to 100KVA capacity & crediting it to No.
Replacement of deteriorated /providing LT dist. Box
35 9924000037 with new above 100KVA capacity & crediting it to No.
36 9924000038 Adjustment of tension in stay wire No.
37 9924000039 Refitting of LA No.
Converting pin point to Shackle point including
38 9924000040 location
dismentaling & restringing etc.
replacement of 11KV Pin insulator with providing new
double pin binding
replacement of 22KV Pin insulator by new 11kv pin
40 9924000042 insulator with spares & providing new double pin No.
Providing 11kv double disc insulators with binding &
Replacement of existing 11kv conductor (all size) with Cond/K
new double pin binding M
43 9924000046 Plumbing of PSC Pole with straightening at pin point No.
Plumbing of PSC Pole with straightening at tension
Plumbing of tilted DP structure (PSC/RSJ/STP) with
refilling of stone Murrum etc.
Providing new 11kv AB /GO switch with fabrication and
insulated colour code jumper, binding, lugs etc
Replacement of old 11kv AB /GO switch with providing
new insulated jumper, binding, lugs etc
Providing cage type loop guard in verticle LT line with per
using PVC reel insulators etc pole
Labour charges for replacement /providing of MMB &
service with all accessories for three phase connection
Labour charges for replacement /providing of MMB &
service with all accessories for single phase connection
Dismentalling of existing Dist.X'mer center(RSJ /STP
51 9924000055 POLE) 25/63/100/200 KVA with all fabrication & No.
creditig the old material to store
52 9924000056 Disconnection from LT pole 1 phase No.
Reconnection from LT pole 1 phase
( payment after receipt of R/C charges)
54 9924000058 Disconnection from LT pole 3 phase No.
Reconnection from LT pole 3 phase
( payment after receipt of R/C charges)
Dismentaling & removing of service line from pole &
crediting to S/dn (1 ph.)
Dismentaling & removing of service line from pole &
crediting to S/dn (3 ph.)
Reconnection of service line complete with PVC cable
Reconnection of service line complete with PVC cable
Providing spiral type earthing by G.I. NO 8(weight 2kg
-5mtr in length) with salt and coal 10kg each,
including pvc rigid pipe 20mm dia( 1.5mtr length) to
pass exposed part of G.I. wire at consumer end with
all materials, earth resistance should be less than
Providing and fixing of signle core 1.5 sq mm single
strand copper insulated cable with cable nail clip for
spiral type earthing at consumer end. The end of G.I.
no 8 is to be connected by connector with copper
61 9924000070 cable of which other end shall be connected to the
earth terminal of meter box. This item shall be used in
location where there is more distance between earth
terminal and earthing terminal of meter. (All materials
supplied by contractor)
9924000065 Stringing of LT ABC of 1*35 SQ MM + 1*25 SQ MM
including fitting of all accessories i.e. special design
suspension / tension clamp, fixing of cross arm, LT
shackle insulator etc. for fixing of messenger wire and
inclusive of dismantling charge of existing bare
62 conductor and crediting in to store & dismantling of KM 8922/-
service line from LT bare conductor and to provide
service connection on Aerial Bunch Cable by insulated
piercing connectors through service connection box
complete as required & directed by Engineer in
9924000066 Stringing of LT ABC of 3*50 SQ MM +1*25 SQ
MM+1*35 SQ MM including fitting of all accessories KM 22303/-
i.e. special design suspension / tension clamp, fixing of
cross arm, LT shackle insulator etc. for fixing of
messenger wire and inclusive of dismantling charge of
existing bare conductor and crediting in to store &
dismantling of service line from LT bare conductor and
to provide service connection on Aerial Bunch Cable by
insulated piercing connectors through service
connection box complete as required & directed by
Engineer in Charge.
9924000067 Stringing of 11KV ABC of 3*95 SQ MM +80 SQ MM
including fitting of all accessories i.e. special design
suspension / tension clamp, fixing of cross arm,
binding to pin insulator, preparing shackle point,
jumpers etc. and inclusive of dismantling charge of
existing bare conductor and crediting in to store
complete as required & directed by Engineer in
9924000068 Stringing of 22 KV ABC OF 3*70 SQ MM +95 SQ MM
including fitting of all accessories i.e. special design
suspension / tension clamp, fixing of cross arm,
65 binding to pin insulator, preparing shackle point, KM 55019/-
jumpers etc. and inclusive of dismantling charge of
existing bare conductor and crediting in to store
complete as required & directed by Engineer in Charge
9924000069 Stringing of LT ABC of 2*50 SQ MM +1*25 SQ MM+
35 SQ MM including fitting of all accessories i.e. special
design suspension / tension clamp, fixing of cross arm,
LT shackle insulator etc. for fixing of messenger wire
and inclusive of dismantling charge of existing bare
66 conductor and crediting in to store & dismantling of KM 15613/-
service line from LT bare conductor and to provide
service connection on Aerial Bunch Cable by insulated
piercing connectors through service connection box
complete as required & directed by Engineer in
-::- SCHEDULE – ‘B 3’: FOR Underground -::-
LABOUR RATE FOR UNDERGROUND CABLE WORK (WITHOUT GST)
Item Code Description Unit FY 2024-25
Labour charge for excavation of cable
trench of 400mm width x 1200mm
depth, in any type of soil for laying of
cable of size up to 240 mm2 (For
additional cable 200 mm additional width
shall be considered i.e. half trench length
is to be considered)
Labour charge for excavation of cable
trench of 600mm width x 1200mm
depth, in any type of soil for laying of
2 9925000002 cable of size up to 240 mm2 (For Meter
additional cable 200 mm additional width
shall be considered i.e. half trench length
is to be considered)
Labour charge for excavation of cable
trench of 400mm width x 1500mm
depth, in any type of soil for laying of
3 9925000003 cable of size up to 240 mm2 (For Meter
additional cable 200 mm additional width
shall be considered i.e. half trench length
is to be considered)
Labour charge for laying of 11kV / 22 kV
XLPE Cable of size up to 240 mm2 &
preparation of sand layer 100mm thick, in
the cable trench & covering the cable with
150 mm dia (Inner), thickness
mm, 1.0 meter long RCC half round muffs
and providing and fixing of 4inch width
yellow colour polyethylene tape with
printing "CAUTION ELECTRIC CABLE
BELOW" at 0.75 m depth from ground
surface after laying cable in trench. This
will provide indication that electric cable is
passing underground so as to protect
cable from mechnical injuries, refilling the
same, as per Instruction of Engineer in
Labour charge for horizontal drilling
using Auger machine without damage
to surface road at max 2.0 mtrs depth &
putting of 6.11 kg/cm2 , class-4,Green
color, 110mm O.D. , 8.5mm thickness
H.D.P.E. pipe confirms to IS 4984-
1987(3rd revision) and BIS certification
5 9925000005 and laying of 11KV/22KV XLPE cable of Meter
size up to 240 mm2 in HDPE pipe, as per
Site Condition (excluding cost of pipe).
The detail map obtained from HDD
machine and excell sheet(hard and soft
copy) indicating the respective depth and
distance from adjacent landmark for each
segment for HDD is must required to be
submitted. HDD to be carried out at depth
1.5 mtrs to 2.0 mtrs as per site conditions
and as per instruction of EIC.
Labour charge for horizontal drilling
manually without damage to surface
road at max 2.0 mtrs depth & putting of
6.11 kg/cm2 , class-4,Green color, 110mm
O.D. , 8.5mm thickness H.D.P.E. pipe
confirms to IS 4984-1987(3rd revision)
and BIS certification and laying of
11KV/22KV XLPE cable of size up to
mm2 size, as per Site Condition
(excluding cost of pipe). The detail map
and excell sheet(hard and soft copy)
indicating the respective depth and
distance from adjacent landmark for each
segment of cable to be submitted. Drilling
to be carried out at depth Minimum
mtrs to 2.0 mtrs as per site conditions as
per instruction of EIC.
Supply of 6.11kg/cm2 , class-4,Green
color, 110mm O.D. , 8.5 mm thickness
H.D.P.E. pipe confirms to IS 4984 and
BIS certification for laying of underground
11KV / 22KV XLPE cable up to 240 mm2
Labour work for RCC concreting on
disputed location and repairing of damage
portion of road crossing for the work
carried out for roads crossing as well as
concreting & muffing of ploes
including all materials (1:2:4)
Providing & fixing concrete stone route
marker of 300 mm width x 150 mm
thick x 650 mm height embedded in
earth at least 300 mm below & 350 mm
above ground level respectively at
distance approx 50 meters along the
length of cable. The RCC concreting
(1:2:4)(all necessary maeterials will be in
bidder's scope) of route marker is to be
carried out 300 mm width x 150 mm thick
x 300 mm below ground level as per
instruction of EIC. The route marker
should be with name of company with
approved yellow colour-DGVCL. The
distance from marker to cable and cable
depth with feeder name etc., marked with
arrow sign is to be painted on it.The route
marker is to be fixed at location near to
any fixed permanent location (not
necessary to fix exact on top of cable) as
per instruction of EIC.
Erection of D.P. (double pole)
structure using 9 / 11 Mtr. RSJ pole
with cable connection arrangement along
with fitting of necessary fabrication for
11KV cable including excavation of pit &
refilling of earth as per instruction of EIC.
(Exclusive of concreting & muffing of
Erection of Single pole structure using
9 / 11 Mtr RSJ pole with cable
connection arrangement along with fitting
ofnecessary fabrication for 11KV/22 KV
cable including excavation of pit & refilling
of earth as per instruction of EIC.
(Exclusive of concreting & muffing of
Erection of D.P. (double pole)
structure using 8.0 Mtr. PSC pole with
cable connection arrangement along with
fitting of necessary fabrication for 11KV
cable including excavation of pit & refilling
of earth as per instruction of EIC.
(Exclusive of concreting & muffing of
Erection of Single pole structure using
8.0 Mtr PSC pole with cable connection
arrangement along with fitting
ofnecessary fabrication for 11KV/22 KV
cable including excavation of pit & refilling
of earth as per instruction of EIC.
(Exclusive of concreting & muffing of
Labour charge for erecting of 11kV /
kV XLPE cable of size up to 240 mm2
on DP Structure with fixing of 02 Nos
polymer cleats on top and middle
part.Polymer cleats, nut bolts etc. fixing
material to be provided by contractor.
Providing & fixing of 6.11kg/cm2
15 9925000015 class-4,Green color, 110mm O.D. , Per Job
8.5mm thickness H.D.P.E. pipe
confirms to IS 4984 and BIS
certification on the erected DP
structure for the mechanical protection
of cable by inserting the cable inside
HDPE pipe. The HDPE pipe shall be
erected in such a way that 300mm shall
be below the ground level and the rest
2700 mm shall be supported on the
DP Structure with 01 No Polymer cleat.All
materials including polymer cleat and Nut
bolt to be provided by contractor.
Providing and fixing of pipe type
earthing from 80 mm dia class-B GI pipe
with pit to be filled with salt & coke and
construction of chamber as per DGVCL
16 9925000016 Drg. No. dg /100 for DP and cable. The No.
earthing pit should be joined with cable by
G.I. strip of size 1” width & 2 mm thick.
All material GI pipe, Coke, Salt etc will be
supplied by bidder.
Supply & fixing of heat shrink type
end terminations (outdoor) for upto
11kV 3C x 185 mm2 size XLPE cable as
per DGVCL technical specification
Supply & fixing of heat & shrinkable end
terminations (outdoor) for upto
kV 3C x 185 mm2 size XLPE cable as per
DGVCL technical specification)
Supply & fixing of heat shrink type end
terminations (indoor) for upto 11kV
3C x 185 mm2 size XLPE cable as per
DGVCL technical specification)
Supply & fixing of heat & shrinkable end
terminations (indoor) for upto 22 kV
3C x 185 mm2 size XLPE cable as per
DGVCL technical specification
Supply & fixing of heat shrinkable
straight through joint for upto 11kV
3C x 185 mm2 size XLPE cableas per
DGVCL technical specification.
Supply & fixing of heat shrinkable
straight through joint type for upto
22kV 3C x 185 mm2 size XLPE cable as
per DGVCL technical specification
Labour charge for excavation of 2100mm
long x 1200mm wide x 1200 mm deep
joint pits for installation of 11kV / 22kV
Straight through joints as per
instruction of engineer-in-charge &
covering the cable with 150 mm dia
(Outer), thickness 25 mm, 1.0 meter
long RCC half round muffs & refilling
same as per instruction of EIC .
Providing and fixing of insulating bus bar,
made from 11KV/22KV XLPE cable after
removal of semi conducting layer and
applying of PVC heat shrinkable anti-
tracking core insulating tubing (1.1KV), on
both end terminal using Aluminium long
barrel heavy duty up to 240 sq mm lugs,
24 9925000024 Aluminium bus connector. Taping with No.
PG- clamp for bus conductor as per
drawing and as per instruction of EIC. The
Alluminium lugs and PG clamp shall be
covered with 11KV/22KV HT insulating
tapes.(11KV/22KV XLPE cable will be in
scope of DGVCL while all other materials
will be in bidder's scope)
Testing of cable at various points and
commissioning the feeder as per
25 9925000025 instruction of engineer-in-charge.Test No.
result shall be submitted by contractor
Preparation and submission of 6 (six)
copies, of complete layout drawings
26 9925000026 with GIS mapping as per actual cable Set
routing showing road crossing, HDPE pipe
sleeving, jointing locations, markers etc.
Providing and fixing of Sign Board at
junction point Made out of 2 mm
aluminium sheet size 750x300 mm (2.5 x
1ft) rectangle, as per design, pre treated
with phosphate process and acid etching
coated with one coat of epoxy primer and
two coats of best quality paints,
refloctrorised with Hi-Intensity retro –
27 9925000027 reflective sheeting as per the latest and No.
frame fabricated from suitable size iron
angle. The Sign Board is to be fixed on
the base prepared from channel and
bracing angles which is grouted by means
of cement concreting of 1:2:4 for size of
300 mm dia x 800 mm height (500 mm to
be grouted in ground). The details to be
displayed on sign board will be given by
In-charge Engineer.(a) Hi intensity Micro
prismatic Grade
Providing and fixing of Sign Board
(Danger Board) on Distribution
Transformer Centers
Made out of 2mm aluminium sheet size
300x300mm (1x1ft) as per design, pre
treated with phosphate process and acid
etching coated with one coat of epoxy
28 9925000028 primer and two coats of best quality No.
paints, refloctrorised with Hi-Intensity
retro-reflective sheeting as per the latest
and frame fabricated from suitable size
iron angle. The Sign Board (Danger Board
is to be fixed at the location as per
instruction of In-charge Engineer.
(a) Hi intensity Micro prismatic Grade
Providing & fixing of aluminium tag of size
250 mm (L) x 75 mm (W) from 3 mm
aluminium sheet along with 1.0 mm dia
aluminium binding wire for fixing of
aluminium tag near end termination joint
at DP structure for identifyng the cable.
The details of feeder i.e. 11 / 22 KV with
feeder name shound be punched on the
tag by letter punch of size 16 mm as per
instruction of In-charge Engineer.
Supply & fixing of heat shrink type end
terminations (outdoor) for 11kV 3C x
240 mm2 size XLPE cable as per DGVCL
technical specification
Supply & fixing of heat & shrinkable end
terminations (outdoor) for 22 kV 3C
x 240 mm2 size XLPE cable as per
DGVCL technical specification)
Supply & fixing of heat shrink type end
terminations (indoor) for 11kV 3C x
240 mm2 size XLPE cable as per DGVCL
technical specification)
Supply & fixing of heat & shrinkable end
terminations (indoor) for 22 kV 3C x
240 mm2 size XLPE cable as per DGVCL
technical specification
Supply & fixing of heat shrinkable
straight through joint for 11kV 3C x
240 mm2 size XLPE cableas per DGVCL
technical specification.
Supply & fixing of heat shrinkable
straight through joint type for 22kV
3C x 240 mm2 size XLPE cable as per
DGVCL technical specification
Installation, Testing and commissioning
of 11 KV,630 A SCADA Compatible, RRL
type- 3 Way RMU including Two
numbers of earthings as per Drawing
(material is in bidder's scope) and as per
DGVCL Technical specification.
Installation, Testing and commissioning
of 11 KV,630 A SCADA Compatible, RRLL
type- 4 Way RMU including Two
numbers of earthings as per Drawing
(material is in bidder's scope) and as per
DGVCL Technical specification.
Installation, Testing and commissioning
of 22KV,630 A SCADA Compatible, RRL
type-3 Way, RMU including Two
numbers of earthings as per Drawing
(material is in bidder's scope) and as per
DGVCL Technical specification.
Installation, Testing and commissioning
of 22KV,630 A SCADA Compatible, RRLL
type-4 Way, RMU including Two
numbers of earthings as per Drawing
(material is in bidder's scope) and as per
DGVCL Technical specification.
Construction of plinth for 11KV, RRL
type- 3 Way (i.e Two numbers of
Isolator & One number of Breaker) Ring
40 9925000042 Main Unit as per DGVCL's technical No.
specification mentioned in drawing no:
Drg. 11kv-01. All required material will be
supplied by contractor.
Construction of plinth for 11KV, RRLL
type- 4 Way (i.e Two numbers of
Isolator & Two number of Breaker)Ring
41 9925000043 Main Unit as per DGVCL's technical No.
specification mentioned in drawing
no:Drg. 11kv-02.All required material will
be supplied by contractor.
Construction of plinth for 22KV, RRL
type- 3 Way (i.e Two numbers of
42 9925000044 Isolator & One number of Breaker) Ring No.
Main Unit as per DGVCL's technical
specification mentioned in drawing no:
Drg. 22kv-01. All required material will be
supplied by contractor.
Construction of plinth for 22KV, RRLL
type- 4 Way (i.e Two numbers of
Isolator & Two number of Breaker)Ring
43 9925000045 Main Unit as per DGVCL's technical No.
specification mentioned in drawing
no:Drg. 22kv-02.All required material will
be supplied by contractor.
Modifications e.g. Providing and fixing of
Terminal protectors i.e. Re-use able boot
(HT Side 11/22KV, LT Side 1.1KV)
including 11/22 KV insulating taps and
L.T.(1.1 KV) insulating taps ,Busbar,
Tapping from Bus Bar (11/22 KV XLPE
cable) through P.G. Clamp for H.T.
Jumper to D.O. Fuse to bushings of
Transformer Center, providing & Fixing of
jumper and providing & fixing of Heat
Shrinkable Anti Tracking Core Insulating
Tubing (Insulation Level 11/22 KV) in H.T.
jumper , Clamping arrangement of cable
support frame on both side of existing
Over Head type Distribution Transformer
to utilize in Under Ground cable network
as per drawing & as per instruction of
Engineer incharge. All live parts i.e. PG-
Clamp, connections of D.O.fuses, HT
bushings etc . shall be covered with
fixinng of 11/22 KV HT insulating tapes. (
11/22 KV XLPE cable will be in scope of
DGVCL while all other materials will be in
bidder's scope ) .
Laying of any size of 11/ 22 KV XLPE
45 9925000047 /PILC Cable in redaymade trench or in
Labour charges for Lying of O/H XLPE
cable pole to pole
Supply of 150 mm dia (Inner), thickness
47 9925000064 25 mm, 1.0 meter long RCC half round No.
Total of schedule B1, B2& B3
(+)_______%Above, (-)_______%Below, Rate to
(Rs.In Words… Fifty Lacs Only)
Net Total of Schedule ‘B1, B2& B3:
Amount in Words: (Fifty Lacs Only)
1. Whatever Steel Material removed after replacement should be credited to Store.
2. The rates are inclusive of PF & Work Contract Tax & excluding of GST.
3. Contractor has to carry out work under Bilimora Town Sub-Division under
Valsad-Rural Division.
4. DGVCL will provide 1ph & 3ph LT Ariel Bunch Cable 11/22kv HT ABC with necessary
accessories to the contractor.
5. The rates are inclusive of dismantling charges of existing bare conductor and
crediting in to store & dismantling of service lines from LT bare conductor and to
provide service connections on ABC by insulated pierce connectors through service
connection box.
6. The contractor has to collect all the required materials from DGVCL store as well as
credit the dismantle material to the DGVCL store at their cost.
1. DGVCL will provide key material like M.S. materials,ABC/Bare conductors,PSC/RSJ
Poles,Insulators,Fabricated materials etc. to the contractor.
2. All fabricated items shall be fabricated as per DGVCL approved drawing and by welding
rods confirming to the relevent ISI specification and as directed by Engineer in charge.
3. Necessary electricity connection for fabrictated items shall be provided by DGVCL on
payment of required charge for connection & electricity bill of the same shall be paid by the
4. All the rates are inclusive of PF and Exclusive of GST applicable time to time.
5. All steel material are to be painted as below:
(a) Scrubbing of rusted surface properly before applying the paints on to the RSJ poles &
steel fabricated materials of RSJ/PSC poles is must required.
(b) Two coats of approved ISI mark red oxide (primer) is to be properly painted for the
RSJ poles & steel fabricated materials of RSJ/PSC poles.
Two coats of approved ISI mark silver paint (i.e. triple mangoes or equivalent quality silver paint)
is to be properly painted on to the RSJ poles & steel fabricated materials of RSJ/PSC poles.
Executive Engineer (O&M)
Valsad Rural Division.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1. Schedule A.pdf
2. Bid Document.pdf
4. Detail Technical Specification.pdf
Amend an Arbitration Clause.pdf
GENERAL TERMS and CONDITIONS.pdf
Notice Inviting Tender.pdf
Schedule-B.pdf
TECHNICAL BID.pdf
TECHNICAL SPECIFICATIONS FOR THE WORK.pdf
Letter to All DISCOMs for Ratified Common UG Tender Conditions.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .