| 1 | L1₹45.6 LAccepted-AOC | L1 | Accepted-AOC Accepted for acceptance being lowest. | |
| 2 | L2₹47.6 L+₹69,527.75 (1.48%)Rejected-Finance 05 AYODHYA NAGAR NEAR RAM MANDIR BEHIND HARIYA COLLEGE GOKUL NAGAR JAMNAGAR 361004 | JAMNAGAR | JAMNAGAR | GUJARAT | 361004 | L2 | Rejected-Finance Not L1. | |
| 3 | L3₹48.3 L+₹1.4 L (2.96%)Rejected-Finance | L3 | Rejected-Finance Not L1. | |
| 4 | L4₹51.2 L+₹4.3 L (9.08%)Rejected-Finance | L4 | Rejected-Finance Not L1. |
Tender Value
₹48.6 L
EMD Value
₹98,000
Closing Date
14 Nov 2022, 6:00 pmClosed
GE (AF) Jamnagar No.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
SPECIAL REPAIRS TO CERTAIN SMQs AT AF-II AND ADDN / ALTN TO WASHROOMS OF LIVING IN BILLETS AT AF STATION UNDER GE (AF) JAMNAGAR NO.2
2022_MES_558170_1
8384/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No.2
₹98,000
Yes
9 Dec 2022
17 Oct 2022
16 Nov 2022
17 Oct 2022
14 Nov 2022
31 Oct 2022
Amount
M&L for complete removal of existing treatment from ceiling and applying two coats of white wash over a coat of chalk whiting (putty) 1.5mm thick on ceilings complete all as specified and directed.
M&L for applying three coats of white wash on new plastered wall surface including preparation of surfaces complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coat of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying two coats of white wash over a coat of chalk whiting (putty) 1.5mm thick on ceiling complete all as specified and directed.
M & L for complete removal of existing treatment from walls and applying two coats of oil bound distemper over a chalk whiting (putty) 1.5mm thick on walls complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whiting (putty) complete all as specified and directed.
M&L for complete removal of existing treatment from external surfaces on walls by wire brushes & stopping of surfaces and levelling/edging the disturbed places/edges using necessary filling compound of Allek Putty to obtain smooth regular/even finish using sand paper and applying two coats of exterior acrylic emulsion (weather proof treatment) over one coat of primer, at any height including necessary scaffolding etc complete all as specified and directed. Note: Ht of bldg G+2
M&L for preparation of new plastered/concrete surfaces of walls and applying two coats of exterior acrylic emulsion (weather proof treatment) over one coat of primer, at any height including necessary scaffolding etc complete all as specified and directed. Note: Ht of bldg G+2
M&L for preparation of new wooden surfaces of any description exc 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer including prepration to new steel surfaces exc.10cm in width or girth complete all as specified and directed.
M&L for repairing the edge/corner of chajja/roof projection and similar work by removing of plastered width/girth exceeding 15cm & n.exc 30cm and making good with 15mm rendering in cement mortar 1:3 to match with existing surfaces complete all as specified and directed. Note Ht of Bldg G+2
Demolition of brickwork or stone / boulder / block masonry, built in cement mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and directed.
M & L for precast cement concrete 1:5:8 (using 20mm graded stone aggregate) solid building blocks exe 10 cm thick, in width with plain or interlocking joints setting in CM 1:6 complete in wall or pillars complete all as specified and directed.
Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, including removal of debries to a distance exc 1.5 Km but n. exc 2 Km complete all specified and directed.
M&L for 10mm thick Rendering on brick, concrete surfaces in cement mortar 1:6 finishing even and smooth without using extra cement and similar likes complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on stone / PCC block masonry wall surface, including mixing liquid water proofing compound as per manufacturers instructions, finished the surface even & smooth without using extra cement complete all as specified and directed. Note:- WPC will be measured & paid separately
M&L for rendering 5mm thick on concrete surfaces in cement mortar 1:3 finishing even and smooth without using extra cement to RCC ceiling, chhajjas, roof projection, facia, fins, parapet etc and similar likes at any height including necessary scaffolding, ladder, formork complete all as specified and directed.
Demolition of Cement concrete of any description in any position not otherwise specially provided for sunken floor and similar work including removal of debris to outside of MD land complete all as specified and directed.
M&L for 40mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in flooring laid in panels finished even and smooth without using extra cement complete all as specified and directed.
M&L 100 mm thick cement concrete 1:2:4 type B-2 (using 40mm graded aggregate) as in floor/ hard standing etc all as specified.
M&L for 100mm thick cement concrete 1:4:8, type D-2 (using 40mm graded stone aggregate) as in sub base for path/flooring complete all as specified and directed.
M&L for broken stone hardcore of gauage n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as plinth protection finishing even and smooth without using extra cement and making joints complete all as specified and directed.
M&L for providing water proofing treatment of sunken portion of WCs, bathroom etc. by applying cement slurry mixed with Acrylic based polymer modified cementitious composite compouned coating of make as approval in Technical Instruction 5/2003 by adding: (a) 15mm thick rendering CM (1:4) with Liquid water proofing compound 200ml per 50kg bag of cement on floor and wall, finishing the surface even and smooth without using extra cement. The surface shall then be cured and allowed to dry. Note: (a) Water proofing compound shall be measured and paid separately. (b) First layer of slurry of cement @ 0.488 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hrs. (c) Second layer of slurry of cement @ 0.242 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ .126 kg/sqm. This layer will be allowed to air cure for 4 hrs followed with water curing for 48 hrs including dismantling of existing treatment etc complete all as specified and directed.
M&L Plain cement concrete (1:5:10), type E-2, using 40 mm graded brick aggregate as in mass concrete (sunken portion) complete all as specified and directed.
M&L for cutting/drilling hole in brick wall/RCC beam or slab exc 300mm deep of WC/bath by mechanical mean and fixing with and including 40mm GI pipe as spouts pipe of require length at site, complete all as specified and directed.
Dismantling of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including removal of debries to outside MOD land complete all as specified and directed.
M&L for Glazed coloured ceramic tiles in vertical surfaces 300mmx450mmx7mm thick over & including 10mm thick Screed bed or bedding layer in CM 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L to cement concrete type B0, 1:2:4 (12.5mm graded stone aggregate) 25mm thick as in levelling course of flooring & roof complete all as specified and directed.
M&L for non - skid joint free coloured ceramic tiles (1st quality) not less than 7 mm thick of size exc 0.06 sqm but n exc 0.11 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles over & including 15mm screed bed or bedding in CM 1:6 complete all as specified and directed.
M&L for non-skid Coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm including 15mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for light shade colour vitrified ceramic tiles 9-10 mm thick (square / rectangular) polished, area of each tiles n.exc 0.36 sqm in floors etc laid over and including 15 mm thick screed bed or bedding layer in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M & L for vitrified ceramic tiles light shade 09-10mm thick (square/rectangular) polished area of each tile not exceeding 0.36 sqm as in skirting and dado laid over and incl 10mm thick rendering in CM 1:4 and pointing complete all as specified and directed.
M&L for Glazed ceramic tiles in vertical surface 300 x 450 x 7mm / 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat of mortar in CM 1:4 for laying wall tiles finishes complete all as specified and directed.
Dismantling of granite, marble or kota stone slabs and granite tiles laid, bedded and pointed in any mortar of any description or thickness in floors, aprons cills or plateform etc complete all as specified and directed.
M&L for Granite work 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in coloured cement (1:2) using marble dust with admixture of pigment to match with granite shade complete all as specified and directed.
M & L for machine cut & machine polished kota stone slab 18 to 20 mm thick as in kitchen plateform, treads of steps laid over and including 15 mm thick screed bed in CM 1:6, jointed with grey cement slurry mixed with colour pigment to match the shade of the slab, rubbing and polishing complete all as specified and directed.
M & L for machine cut & machine polished kota stone slab 18 to 20 mm thick as in kitchen plateform, treads of steps laid over and including 15 mm thick screed bed in CM 1:6, jointed with grey cement slurry mixed with colour pigment to match the shade of the slab, rubbing and polishing complete all as specified and directed.
M&L for granite 16-18 mm thick work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms, vertical surface of wall also and like in 12mm thick Screed bed or bedding layer cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite etc complete all as specified and directed.
M&L for rounding to edges of granite stone slab one edge, such as in steps, cooking platform and other similar situations complete all as specified and directed.
Supply and fix in repairs 10 Litre capacity PVC syphonic action type flushing cistern low level with inlet ball valve, float, handle, flush pipe 32 mm, PVC connection 450 mm fixed in position and connecting complete all as specified and directed.
S&F PVC connection 15mm dia and 600mm long with 2 Nos PTMT nuts, complete all as specified and directed.
S&F PVC connection 15mm dia and 450mm long with 2 Nos PTMT nuts, complete all as specified and directed.
S&F in repair 15 mm size bib cock long body cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipes complete all as specified and directed. Make: Plumber cat part No EC-0203 or equivalent makes mentioned in Appx 'B' to PS.
S&F in repair 15 mm size bib cock short body cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipes complete all as specified and directed. Make: Plumber cat part No EC-0202 or equivalent makes mentioned in Appx 'B' to PS.
S&F in repair 15 mm size angle cock/valve, cast copper alloy, chromium plated with long shank, fancy type with capstan head, screwed down, screwed both end for iron pipes complete all as specified and directed. Make: Plumber cat part No EC-0507 or equivalent makes mentioned in Appx 'B' to PS.
S&F 15mm bore stop cock, cast copper alloy chromium plated, fancy type with capstan head, with long shank and cup (concealed type) screwed down, screwed both end for iron pipes complete all as specified and directed.
S&F in repair pillar taps cast copper alloy, chromium plated, screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S & F in repairs 15 mm size CP pillar cock long nose cast copper alloy, chromium plated, screwed for iron pipe or for brass ferrule complete all as specified and directed. Make : Plumber cat part No EC-0106 or equivalent makes mentioned in Appx 'B' to PS.
S&F in repairs stainless steel grating with or without hole of size 150mm x 150mm fixed with cement complete all as specified and directed.
S&F in repair Waste pipe of PVC 31/32 mm x 750mm long including all fittings complete all as specified and directed. Make: Prayag Cat No 3272
Taking up or down 15mm bore steel tubing and connections, complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections, complete all as specified and directed.
Taking up or down 25mm bore steel tubing and connections, complete all as specified and directed.
S & F 15mm bore Tubes, `medium grade' galvanised, steel water tubing, with all fitting such as GI bends, tee, union etc fixed on walls and ceilings or laid in floors complete all as specified and directed.
S & F 20mm bore Tubes, `medium grade' galvanised, steel water tubing, with all fitting such as GI bends, tee, union etc fixed on walls and ceilings or laid in floors complete all as specified and directed.
S & F 25mm bore Tubes, medium grade' galvanised, steel water tubing, with all fitting such as GI bends, tee, union etc fixed on walls and ceilings or laid in floors complete all as specified and directed.
Supply and fix 15 mm outer dia CPVC pipes SDR 11 & plain CPVC SER 11 fittings, fixed on wall concealed or exposed /ceiling or laying in floors complete all as specified and directed. Note:- Cutting chease wherever required will be measured & paid separately.
Supply and fix 20 mm outer dia CPVC pipes SDR 11 & plain CPVC SER 11 fittings, fixed on wall concelled or exposed /ceiling or laying in floors complete all as specified and directed. Note:- Cutting chease wherever required will be measured & paid separately.
Fixing only 15mm bore steel tubing, medium grade, laid in floor or fixed to walls, ceilings etc with fittings and fixtures including cleaning old pipe, cutting, threading complete all as specified and directed.
Fixing only 20mm bore steel tubing, medium grade, laid in floor or fixed to walls, ceilings etc with fittings and fixtures including cleaning old pipe, cutting, threading complete all as specified and directed.
M&L for cutting chases, of girth not exceeding 10 cm for concealed water tubing or concealed conduit wiring, etc. in stone / brick masonry wall built in cement mortar and making good, disturbed surface in Cement mortar 1:3 complete all as specified and directed.
S & F in repairs brass chromium plated overhead shower 125 mm size with 225 mm arm and flange for 15 mm inlet pipe complete all as specified and directed.
S&F 25mm Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 25 mm bore (minimum weight 210gms), complete all as specified and directed.
S&F in repairs sink of stainless steel 1mm thick kitchen or laboratory with plugs washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410 x 330 x 160mm complete all as specified and directed.
S & F Rotational moulded polyethylene water storage tanks 500 litres capacity three layered (clylindrical vertical with closed top) hoisted and fixed in position including dismantling the old PVC water storage tank all as specified in SSR Part-I.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but not exc 4 sqm each complete all as specified and directed.
Taking down shutters of any description n exc 1sqm each.
Taking down shutters of any description exc 1sqm but n.exc 2.00 Sqm each.
M & L for 2nd class hard wood scantling in framed work (wrought) complete all as specified and directed.
M&L for factory made flush shutters, 40mm thick solid core construction, with block board core and plywood face panels, fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed.
Supply & paste 0.90mm thick Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions.
M&L for factory made 35mm thick Glazed and skeleton shutters, 2nd class hardwood, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8 clause 8.20 (a); supplied and fitted to chowkats complete all as specified and directed.
S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube fixing in existing opening including necessary hold fast and complete all as specified and directed.
S&F Factory made solid PVC moulded door shutter 28 to 30mm thick (stiles) with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face & 2mm plain colour PVC sheet on back face, suppling & fixing in the frame including butt hinges-03 Nos, Aluminium 02 Handles (100mm), and Aluminium tower bolt-150mm at site as per specification complete all as specified and directed.
S&F stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed in position, complete all as specified and directed.
Supply fabricate & fix in position aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) three track window ( two shutters glazed & one shutters wiregauge) with frame, glazed with 4 mm thick tinted glass and, wire gauge with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm including rubber bead joining cleat for fixing in position, concelled type lock for all three shutter, PVC roller etc all as specified below complete all as specified and directed. (a) Frame (top & side) section shall of size 92.00 x 31.75 x 1.50 mm (Section No 20831) (b) Frame (bottom) section shall of size 92.00 x 31.75 x 1.50 mm (Section No 20832) (c) Top & side Members of shutter Section shall be of size 18.00 x 40.00 x 1.55 mm (Section No 20738) (d) Shutter Interlock Section shall be of size 18.00 x 40.00 x 1.45 mm (Section No 20737) (e) Bottom Members of shutter Section shall be of size 18.00 x 40.00 x 1.55 mm (Section No 20736). Note: Section No given above are of make Jindal, Contractor may use similar section of other make as aproved by GE.
S&F aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) ventilator, partialy glazed and partialy louvers, outer frame & mullion fabricated with aluminium section of size 82.50 mm x 38.00 mm x 1.70 mm thick (Cat No 20036), half portion glazed with 4 mm thick frosted glass including rubber beading, & glazing clip, half portaion louvers of 80 mm wide & 4 mm thick frosted glass including aluminium louver patti including S.S wire gauge of fixing of 0.36mm dia and 1.40 width of aparture with 25x3mm thick aluminium strip with screw to upper half portion of ventilator all fitting & fixture and fixed in position including taking down old ventilator complete all as specified and directed. Note: (i) Section No given above are of make Jindal, Contractor may use similar section of other make mention in Appx B.
S&F in repairs stainless steel kitchen plate rack of size 31"x30"x10" deep, fabricated with 0.63mm sheet fixed in position on wall complete all as specified and directed. Make:- Silver Shine model No KPR-314 or equivalent of make specified in Appx 'B'.
S&F in repairs corner glass shelves, made of ABS with glossy finish of size 280 wide x 360 mm deep x 590 Height for bathrooms fixed with screws as per manufacturer complete all as specified and directed. Make : Neelkamal / Godrej / Prayag / Shakti / Nirali
S&F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F towel rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and directed.
S&F bands, straps, supports or stays for rainwatre, ventilating pipes, including bolts, if required; hooks(stay), heavy for large gates; hook and pintle hinges: large hasps and staples; chains, hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps; plate wahsers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L for cutting holes n.exc half bricks in brick wall built in cement lime mortar and stone wall for inserting holdfasts and making good dismantled portion in CM 1:3 or cement concrete 1:2:4 type B1 as required complete all as specified and directed.
S&F Floor door stopper of aluminium alloy body and tongue, 140mm size, anodised, with hard drawn steel spring complete all as specified and directed.
S&F 150 mm long extruded aluminium alloy, handles, fabricated type, anodized, complete all as specified and directed.
S&F in repairs 75mm long Mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed.
S&F 75 mm size Stainless steel butt hinges medium weight, fixed to chowkhat complete all as specified and directed.
S&F 100 mm size Stainless steel butt hinges medium weight, fixed to chowkat complete all as specified and directed.
S&F 150mm aluminium anodised tower bolts of extruded section, complete all as specified and directed.
S&F 75mm aluminium anodised tower bolts of extruded section, complete all as specified and directed.
S&F in repairs 300mm long MS ordinary rat tail rod pattern springs including roller and roller plate complete all as speccified and directed.
S&F anodised Aluminium sliding door bolts 300mm,plate type, with bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
S&F in repairs 25mm drapery rod Stainless steel including taking down the existing.
S&F SS ornamental stainless steel holding brackets for 28mm dia curtain rods.
S&F in repair 25mm size Magnetic and connected plate to shutters and frame as per sample.
S&F in repair kitchen basket fabricated with stainless steel section (SS-304) of size 450 x 500 x 100 mm for different use such as placing plain plate/dish/cup & saucer/cutlery/thali etc fixed in position with one pair telescopic Channel mild steel chromium plated, roller type, complete all as specified and directed. Make : Prayag, Shakti, Nirali, Neelkamal, Godrej etc.
S&F in repair kitchen basket fabricated with stainless steel section (SS-304) of size 450 x 500 x 150 mm for different use such as placing plain plate/dish/cup & saucer/cutlery/thali etc fixed in position with one pair telescopic Channel mild steel chromium plated, roller type, complete all as specified and directed. Make :- Prayag, Shakti, Nirali, Neelkamal, Godrej etc
S&F in repair kitchen basket fabricated with stainless steel section (SS-304) of size 450 mmx 500mmx 200 mm for different use such as placing plain plate/dish/cup & saucer/cutlery/thali etc fixed in position with one pair telescopic Channel mild steel chromium plated, roller type, complete all as specified and directed. Make :- Prayag, Shakti, Nirali, Neelkamal, Godrej etc
S&F 18/19mm thick plywood (12 Nos of ply) grade BWR, type BB fixed width screws to timber frame work or ply wood including 2nd class HW fillets of bull nosed splayed, chamfered or rounded edge etc exc 3 and n.exc 6 sqcm complete all as specified and directed.
S&F 12mm thick plywood (7 Nos of ply) grade BWR, type BB fixed width screws to timber frame work or ply wood including 2nd class HW fillets of bull nosed splayed, chamfered or rounded edge etc exc 3 and n.exc 6 sqcm complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description by cutting or without damage of structure not otherwise provided for complete all as specified and directed.
S&F framed work such as grills, framed guards bars and similar work conforming to 290 Gde F-165 complete all as specified and directed.
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed.
Demolition and breaking up drains pipes salt grazed wares internal dia of pipe 150mm inclduding PCC packing under hunching against the sides of pipe bed and complete PCC of bed and removal of debris to outside MOD land complete all as specified and directed.
Material and labour for reinforcement cement concrete pipes, 150mm bore, class NP2, laid and jointed with collars complete all as specified and directed.
M&L for PCC (1:3:6) type C2, 40mm graded aggregate, as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid & tested for 150 mm bore for RCC pipes complete all as specified and directed.
Returning filling including spreading, levelling, watering and well ramming in layers not exc 25 cm thick soft & loose soil complete all as specified and directed.
Removing excavated material exc 250 m and n exc 500m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
Cutting into existing manhole in running sewage line for connecting new drains of 150/200mm internal dia of pipe, making good to walling and rendering, cutting out branch channel, and as required complete all as specified and directed.
M&L for precast cement cocrete cover slabs (1:2:4) type B1 (20mm graded stone aggregate) set in CM 1:4 for manholes complete all as specified and directed.
M & L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F in repair 100 mm dia Cast iron sand cast pipe, for soil, waste and vent in any length with or without ears, fixed on wall with MS clamp, with cement joints, complete all as specified and directed.
S&F in repair 75 mm dia Cast iron sand cast pipe, for soil, waste and vent in any length with or without ears, fixed on wall with MS clamp, with cement joints, complete all as specified and directed.
S&F in repair 100 mm Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed.
S&F in repair 100 mm dia bore Cast iron oval access door bend (any radius) diminishing pieces or tapers (Larger bore measured) complete all as specified and directed.
S&F in repair 75 mm dia bore Cast iron oval access door bend (any radius) diminishing pieces or tapers (Larger bore measured) complete all as specified and directed.
S&F in repair cast iron vent cowl 100 mm bore dia complete all as specified and directed.
S&F in repair cast iron vent cowl 75 mm bore dia complete all as specified and directed.
S&F 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring jointed with solvent cement, fixed in wall with clamp including dismantling of rain water pipes complete all as specified and directed.
S&F PVC (SWR) pipes 75 mm dia single socketed, in any length, with rubber ring joints jointed with solvent cement, laid in trenches or in floors complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring jointed with solvent cement, fixed in wall with clamp including dismantling of rain water pipes complete all as specified and directed.
S&F PVC (SWR) pipes 110 mm dia single socketed, in any length, with rubber ring joints jointed with solvent cement, laid in trenches or in floors complete all as specified and directed.
S&F 75mm dia PVC (SWR) bends/shoes any radius complete all as specified and directed.
S&F 110mm dia PVC (SWR) bends/shoes any radius complete all as specified and directed.
S&F PVC (SWR) cowl of 75mm bore of any radius complete all as specified and directed.
S&F PVC (SWR) cowl of 110mm bore of any radius complete all as specified and directed.
S&F PVC (SWR) branch piece, single (Single Y) equal or unequal 75mm bore fixed complete all as specified and directed.
S&F PVC (SWR) branch piece, single (Single Y) equal or unequal 110mm bore fixed complete all as specified and directed.
S&F PVC (SWR) branch piece, double (double Y) equal or unequal 75mm bore fixed complete all as specified and directed.
S&F PVC (SWR) branch piece, double (double Y) equal or unequal 110mm bore fixed complete all as specified and directed.
S & F PVC (SWR) junction single, 110mm (Single T) equal or unequal complete all as specified and directed.
S & F PVC (SWR) junction single, 75mm (Single T) equal or unequal complete all as specified and directed.
S&F in repairs white Vitreous china wash down water closet (pedestal pattern) with fixing bolt, with plastic water closet seat, white, closed pattern with flat bottom, and cover with aluminised hinging device, including all connections complete all as specified and directed.
Supply and fix in repairs white vitreous china squatting pan ‘ORISSA’ pattern of size 580 mm x 440 mm white with integral foot rests with cast iron ‘P’ or ‘S’ trap, front or back inlet including all connection and provision of lime concrete base complete all as specified and directed.
S&F in repair 75mm cast iron Floor / Nahani trap with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
S&F in repair PVC(SWR) gully trap 125/110mm, setting and jointing with solvent cement, plain with grating including jointing to waste pipe fixed in cement concrete 1:2:4, type B1 using 20mm graded stone aggregate complete all as specified and directed.
S&F in repair white vitreous china wash hand basin (Flat back) of size 550 x 400 mm, fixed on and including new brackets complete including screwed for iron pipe, 32mm size brass chromium plated wasted coupling, 750mm long PVC waste pipe, PVC connection pipe 15mm size and 450mm long with PTMT nuts and washer at both end complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for including removal of debries to outside MOD land complete all as specified and directed.
Demolition of cement concrete (reinforced) water tank incl cutting of reinforcement as required to facilitate demolition in any description and in any Position not otherwise specifically provided for and removing the same from Site(s), complete all as specified and as directed.
M&L for 40mm thick PCC type B1 1:2:4 (using 20mm graded stone aggregate) as in padding in roof complete all as specified and directed.
M&L PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) for plateform/raising of plateforms of water tanks on roof, as in benching/coping, apex stones bed plates etc including necessary formwork complete all as specified and directed.
Roughening the surface of old concrete roof by picking, sweeping, cleeaning and washing down with water to remove dust etc and applying neat cement slurry @3.00 Kg/Sqm complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on fair face of brick work surface and mixing only liquid water proofing compound as per manufacturers instructions, finished the surface even & smooth without using extra cement complete all as specified and directed. Note:- WPC will be measured & paid separately.
M&L rendering plastering in CM 1:4, 10mm thick on concrete surfaces adding with liquid water proofing compound as per manufacturers instructions, finished even and smooth without using extra cement including parpet wall curving complete all as specified and directed.
M&L for applying cold bituminous Primer on plastered roof surfaces with bituminous primer @ 0.3 kg / sqm as per IS 3384 and laying APP (Atactic polypropylene polymer) modified membrane 3mm thick (weight not less than 3.5 kg / sqm with non woven polyester reinforcement mineral finish laid with 100mm side overlap and 100mm width overlap sealing all round as per manufacturer instruction complete after picking sweeping wire brushing and cleaning top surfaces of cement concrete all as specified and directed. The membrane has to be laid with LPG torch and overap sealed and fineshed neat. Note : The work has to be carried out in 2-3 storeyed buildings.
Supply only liquid water proofing compound
S&F 25 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
M & L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab incl rubbing & polishing complete with need cement slurry laid over incl 15mm thick cement screed in CM 1:6 complete all as specified and directed.
S&F in repair 32 mm dia Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2, fixed as in spout pipe and making good disturbed surface in CM 1:3 complete all as specified and directed.
Demolition of concrete surfaces in ground floor and paving n.exc. 15cm thickness (below or above ground level) and removing the same to a distance of 1.5km including loading and dumping / levelling at the destination complete all as specified and directed.
S&F in repair Health Fauset (Hand shower) with 8mm dia 1 metre long easy flex tube and in chorme finish & wall hook complete all as specified and directed. Make: Plumber cat part No IT-1904 or equivalent make mentioned in Appx 'B' to PS.
M&L for cutting holes into or through stone/PCC block wall built cm. and making good in cm 1:3 or PCC type B-1 on required Superficial area n exc 150 sq.cm complete all as specified and directed.
M&L for complete removal of existing treatment from wall and and applying two coats of white wash over a coat of chalk whiting (putty) 1.5mm thick complete all as specified and directed.
M&L for forming butt joint 6mm wide and 75mm deep, filled with bituminous mastic (1:3) complete all as specified and directed.
M&L for glass dividing strips, 38 x 1.5mm thick and fixed in position with and including CM 1:4 to confirm to design complete all as specified and directed.
Taking down carefully (copper/aluminum) unsv point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point, socket point or power point including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing material for taking credit and making good the disturbed surfaces of wall/floor or ceiling to match with existing surface and finishing the surfaces with distemper/white washing/colour washing as per existing complete all as specified and directed.
Taking down carefully by unscrewing from main switch boards/cut out boxes/MCB DBs complete sealing the cable end and making good disturbed surface by walls etc.
Taking down carefully by unscrewing from fitting and fixtures such as ceiling fittings, bulk head fittings, tube light fittings, street light, flood LED lights etc all as specified and directed.
Material and Labour for concealed point wiring for one light / fan point controlled bt one, one way switch complete with 1.5 sqmm multi-stranded copper conducter PVC insulated, unsheathed, fire retardent low smoke (FRLS) cable 1100 volt grade ISI marked drawn through and including heavy duty PVC rigid conduit not less than 20mm dia, including all accessories like bend, tees junction boxes etc including 1.5 sqmm multi-stranded copper conducter PVC insulated, unsheathed,fire retardent low smoke cable as a earth wire connected to common earth duly,etc excluding flush boxes suitable for modular switches complete. Note: Rate of point wiring shall include cutting chases for conduit/flush boxes etc
All as per item No.162 above but point wiring for One 3 pin socket outlet 5Amps on the same board with other switches.
All as per item No.162 above but point wiring for One 3 pin 5 Amp socket out let controlled by one switch on independent board.
All as per item No.162 above but point wiring for One bell / Buzzer point controlled by one bell push 5 amp on the same board with other switches or independent.
All as per item No.162 above but point wiring for One light point controlled by two 2-way switch with cable 1.5 sqmm.
All as per item No.162 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 2.5Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as continuous earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch. Make of wire : L&T/RR kables/finolex. Note: Rate of point wiring shall include cutting chases for conduit/flush boxes etc
All as per item No.162 above but wiring with 4.0 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 4.0Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as continuous earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch. Make of wire : L&T/RR kables/finolex. Note: Rate of point wiring shall include cutting chases for conduit/flush boxes etc
M&L for Ceiling rose, 2 to 3 terminal PVC/ polycarbonate, isolated body type suitable for AC 230 volts complete all as specified and directed.
M & L for module cover plate with frame as per site requirement for following module. Make: Legrand/ C&S Electric/havells
(a) 1 module
(b) 2 module
(c) 3 module
(d) 4 module
(e) 6 module
M & L for Modular metal Flush box as per site requirement. Make: Legrand/ C &S Electric/havells
(a) 1/2 module
(b) 3 module
(c) 4 module
(d) 6 module
M & L for modular switch 1 way 6 Amp 1 Module complete all as specified and directed. Make: Legrand Arteor series Cat Part No: 573400 /Kolors (Krest-white)/Crabtree
M & L for Modular switch 2 way 6A , 1 Module complete all as specified and directed. Make: Legrand Arteor series Cat Part No: 573402 /Kolors (Krest-white)/Crabtree
M & L for Modular Switch 1 way 16/20 Amp 1 Module complete all as specified and directed. Make: Legrand Arteor series Cat Part No: 573410 /Kolors (Krest-white)/Crabtree
M &L for Modular Socket 6A 2/3 Pin universal 2 module complete all as specified and directed. Make: Legrand Arteor series Cat Part No : 573470 /Kolors (Krest-white)/Crabtree
M &L for Modular Socket 16A/ 6A 2/3 Pin combined 2 module complete all as specified and directed. Make : Legrand Arteor series Cat Part No :-573471 /Kolors (Krest-white)/Crabtree
M &L for Modular fan step regulator 100 watt 2 module complete all as specified and directed. Make: Legrand Arteor series Cat Part No : 573416 /Kolors (Krest-white)/Crabtree
M & L for Modular Bell push 6A 1 way, 1 Module complete all as specified and directed. Make :- Legrand Arteor series Cat Part No:573413 / Kolors (Krest -white)/Crabtree
Supply and fix in repair of Lamp holder, white Polycarbonate body, with back plate suitable for batten fittings fixed in position & connecting complete all as specified and directed.
Supply and fix for Bell musical type AC 230 Volts, as directed including connecting complete all as specified and directed.
S&F energy efficient LED tube light fitting integrated batten type with built in LED Chip & integral LED driver 22 watt, channel housing & diffuser of length 1200 mm (approx) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed. Make -Wipro cat part No.LL20-221-XXX-65NE3/Philips cat part no. BN O21C LED120S PSU CDL/NW GR(6500K) / HAVELLS
S&F energy efficient LED tube light fitting integrated batten type with built in LED Chip & integral LED driver 10 watt, channel housing & diffuser of length 600 mm (approx) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed. Make Wipro cat part no.LL20-111-XXX-65NE3/Philips cat part no. BN O21LED10S(6500K) / HAVELLS
S&F building security in repair LED Light fitting 35 watt, system efficiency not less than 100 lumen / watt, IP66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminum housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminum housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete. Make :- Wipro, Cat part No LR02-291-XXX-57-XX or equivalent in Philips/ Wipro
Supply and fix in repair LED lamp 5 Watt cap complete all as specified and directed. Make: Wipro Tejas cat part No: N55001 or equallent in phillips.
S & F bulkhead fitting 1x9 watt/1x10watt made of corrosion resistant unbreakable polycarbonate housing factual impact dust and water resistent including LED driver holder connecting & suitable for surface/wall mounted complete all as specified and as directed. Make: HPL cat part no. HLPLEDBH10W(cw) havells/Philips
Taking down carefully (copper/aluminum) sub main wiring complete of any type (batten/surface conduit or concealed) for socket point or power point complete with all fittings such as switches sockets pendants etc complete and making good disturbed surface of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surface with distemper white washing/co0lour washing to match with the existing surface complete all as specified and directed
M&L Sub main wiring using PVC insulated and unsheathed multi stranded FRLS copper conductor cable using approved colour code as per IS drawing in and incl PVC conduit of suitable size with all accessories and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete as specified and as directed of the following sizes of cables.
Using two single core PVC insulated FRLS cable 4 sqmm copper conductor multi stranded and 4.0 sqmm copper conductor insulated cable using as earth wire Note :2 runs of 4sqmm copper cable & 1 run of 4.0sqmm copper cable and one run of casing & caping shall be measured as one unit
Using two single core PVC insulated FRLS cable 6 sqmm copper conductor multi stranded and 6.0 sqmm copper conductor insulated cable using as earth wire Note :2runs of 6sqmm copper cable & 1 run of 6.0 sqmm copper cable and one run of casing & caping shall be measured as one unit
Using two single core PVC insulated FRLS cable 2.5 sqmm copper conductor multi stranded and 2.5 sqmm copper conductor insulated cable using as earth wire Note :2 runs of 2.5sqmm copper cable & 1 run of 2.5 sqmm copper cable and one run of casing & caping shall be measured as one unit
M & L for distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 100 Amps rated copper busbar, neutral bar, earth bar and cable ties for cable management, reversible door for IP 43 & IP 54, single pole and neutral 250 Volts, flush to wall complete with IP 54 protection complete all as specified and directed. Make : Legrand Model: IP 54 IK 09 507641 Ekinox or equivalent in L & T (Hager) / Schnieder (Multi-9).
M&L for MCB single pole & neutral 240 volt C curve 10 KA (32 to63) Amps capacity IP 20 complete all as specified and directed.
M&L for MCB single pole,5 to 30 Amp 240 volt B curve 10 KA, IP 20 complete all as specified and directed.
S & F industrial type plug & socket board SP & N enclosure with 2 pole and earth metal plug & socket complete with 10 Amp MCB SP, Make: Legrand cat part No : 607841 / Havells / Schneider or equivalent make mentioned in Appx 'B' to PS.
M&L for earthing comple with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate no.3 including earth pit in PCC concrete 1:2:4 type B-1,Cast iron cover 10 MM THICK HINGED to CI frame ,excavation and earth work in any type of soil and including protection pipe 15mm dia and water pipe GI tubing 20mm light grade with funnel and wire mesh connected to earthing test point complete all as specified and directed. Note:(i) Rates are inclusive of 7.5m long GI earth wire 4.0mm dia (ii) Rates of CI frame, RCC Pit cover, funnel and wire mesh included in the cost of item.
Taking down ceiling fan complete with rod, canopy and other accessories and deposited to store complete all as specified and directed.
Taking down exhaust fan complete with louvers and other accessories and deposited to store complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five starrated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed.
Supply and fix exhaust fan, made of strudy engineering plastic complete with louvers and blades, voltage 230V, 50Hz, RPM 1200, Copper winding of sweep of 200/250mm
KEVAL ENTERPRISE
EVEREST BUILDERS
nasreenenterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .