Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC 164 A 11 GALI NO 3 RISHI NAGAR KAITHAL 136027 | KAITHAL | HARYANA | 136027 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹34.5 L+₹44,003 (1.29%)Rejected-Finance AMAR NIWAS RA 288 GANDHI CHOWK SADAR BAZAR KARNAL | KARNAL | KARNAL | HARYANA | L2 | Rejected-Finance Highest |
Tender Value
₹34.4 L
EMD Value
₹68,720
Closing Date
20 Jul 2020, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Elect. Division PWD B and R Br., Ambala Cantt
Const. of Administrative Block in SDO (Civil) Complex at Ambala Cantt in Ambala District. (Pdg. Sub Station only).
2020_HRY_133971_1
PWD/Elect-KNL/Elect-AMB/17419
Open Tender
Construction Works
Works
120 days
Ambala Cantt.
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
Executive Engineer, Elect. Divn. PWD B andR Br.,
₹68,720
11 Nov 2020
1 Jul 2020
21 Jul 2020
1 Jul 2020
20 Jul 2020
1 Jul 2020
Amount
1 ( c ) Moulded case Circuit breakers. Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections.HSR No. 31.12 100 amp.to 220 amp.415 V,10 KA 3-phase.HSR No. 31.12 c (ii)
250 amp. 415 V , 35 KA 3-phase.HSR No. 31.12 c (iii)
300 amp. to 400 amp. 415 V , 35 KA 3-phase.HSR No. 31.12 c (iv)
2 Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide.HSR No. 31.13 Size 50 mm x 50 mm x 6 mm.HSR No. 31.13(I)
3 (P) Pipe Laying. Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. HSR No. 31.21 Galvanised iron pipe 65 mm dia on flushed.HSR No. 31.21 (xiv)
4 Supply and erection of PVC pipe of 6 kg. pressure laid 1 metre below ground level complete including digging refilling of the trench with jointing etc. HSR No. 31.21(xxx) PVC pipe 120 mm dia.HSR No. 31.21(xxx) (a)
5 (Q) Earthing HSR No. 31.22 Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required . HSR No. 31.22(i)
Extra for using salt and charcoal / coke for pipe earth electrode as required. HSR No. 31.22(ii)
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required. HSR No. 31.22(iii)
Earthing with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) comlete as equired.HSR No. 31.22(iv)
Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode. HSR No. 31.22(v)
Pdg. and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required . HSR No. 31.22(x)
Pdg. and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required with all labour and material. HSR No. 31.22(xiv)
Pdg. and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required . HSR No. 31.22(xi)
Pdg. and fixing 25 mm x 5 mm G.I. Strip on surface or in recess for connections etc. as required with all labour and material. HSR No. 31.22(xv)
Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required . HSR No. 31.22(xii)
6 Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . HSR No. 31.26 95 Sq. mm 3.5 Core Cable . HSR No. 31.26 (xxix) Ard.
185 Sq. mm 3.5 Core Cable . HSR No. 31.26 (xxxii) Ard.
240 Sq. mm 3.5 Core Cable . HSR No. 31.26 (xxxiii) Ard.
400 Sq. mm 3.5 Core Cable . HSR No. 31.26 (xxxv) Ard.
7 S/E of suitable compression type brass cable glands for underground Cable. HSR No. 31.28 70 Sqmm to 95 Sqmm Cable 3 to 3.5 Core . HSR No. 31.28(iv)
120 Sqmm to 185 Sqmm Cable 3 to 3.5 Core HSR No. 31.28 (v)
240 Sqmm Cable 3 to 3.5 Core . HSR No. 31.28 (vi)
300 Sq mm to 400 Sqmm Cable 3 to 3.5 Core . HSR No. 31.28 (vii)
8 ( T ) Street Light.HSR No. 31.3 Supply and erection of prestressed cement concrete pole as per IS:1678-1960. HSR No. 31.30 (VI) 9 metres long 105 mm x 115 mm at top and 105 mm x 315 mm at bottom with working load of 200 Kg. burried 1.80 m in ground. HSR No. 31.30 (VI) (ii)
9 (X) Miscellaneous .HSR No. 31.35 Supply and erection of shock restoration chart in glass frame HSR No. 31.35 (iv)
Supply and erection of cable route marker made of 50 cm long 10 mm dia M.S.rod welded / revitted at the top with 10 cm. Dia 5 mm thick G.I.plate inscribed with `cable' world on it , having a cross arm 30 cm. long of the same dia welded at the bottom , in existing trench 45 cm. below ground level .HSR No. 31.35 (xi)
Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work.HSR No. 31.35 (ix) 95 sqmm . HSR No. 31.35 (ix) (I)
185 sqmm . HSR No. 31.35 (ix) (l)
240 sqmm . HSR No. (iX) (m)
400 sqmm . HSR No. 31.35 (ix) (o)
10 Supply ,installation,Testing & Commisioning of wall / free standing floor mounting dust & vermin proof compartmentlised Cubical Panel made out of 2mm thick CRCA sheet steel required hardware 3mm thick bakelite sheet provided all along the bus bar & cable alley seperating switches compartment & supporting suitable channel duly painted by 2 coat of zinc / red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU/ Neoprane rubber gasket of not less than 3 mm thickness, seperate detachable gland plate, MS base channel ,hinged door with interlocking arrangement for equipment /switchgear. Transperant acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet of 3mm thick for seperating cable alley to BBC from switch chamber Extended solid copper bus bars upto cable alleys shall be provided for outgoing connections which shall be paid as extra items. Side walls & cable alley compartments shall be having bolted type doors with detachable extension type structure .The panel will be complete with control wiring (copper) & fuse protection. (Only outer area on all sides shall be measured). HSR No. 31.63
11 Suppying & fixing of copper bus bar duly tinned by means of SMC /DMC type insulator high tensile nuts & bolts spring washers fixing to same in existing panel including bending, cutting in required shape & size & insulation with colour coding heat shrinkable PVC insulation complete in all respect.HSR No. 31.64
13 Supply & fixing of rotary handle for ON /OFF operation of existing MCCB in the LT Panel including fixing the same in position with all labour & material required to complete the job in all respect. Rotary handle upto 125 A, MCCBHSR No. 31.66 (i)
Rotary Handle above 125A, MCCBHSR No. 31.66 (ii)
14 S/E of mark double walled corrugated (DWC) HDPE pipe laid 1 Mtr. Below ground level including diging and refilling of earth including cost of suitable size socket cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to entire satisfaction of Engineer- incharge of the work. HDPE Pipe 145/123 outer dia / inner dia.HSR No. 31.67 (iii)
15 Supply & erection of Module case circuit breaker single pole / 4 pole on wall/ on existing pedestal including bounding to earth and making necessary connection required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work. 4 pole MCCB 100 ampHSR No. 31.69 v
4 pole MCCB 200 ampHSR No. 31.69 vi
16 S/E of XLPE (E) 11 KV HT aluminium conductor armoured cable ISI mark laid in existing pipe/ trenches/ surface with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work. 50 sqmm 3 core XLPE cableHSR No. 31.71 (ii)
17 Supply and erection of heavy duty 4 pole ON load changeover load breaker switch comprising of switches 63 amp to 400 amp suitable for operation on 415 V 50 Hz AC supply complete with handle assembly having door interlock & padlocking arrangement on existing panel / including making necessary connections with petty material required to complete the job. 300 amp 4 pole ON load changeover switchHSR No. 31.74 iv)
20 CAPACITOR PANEL 200KVAR Qty 1 nos. AUTOMATIC POWER FACTOR CORRRECTION PANEL Supply, fixing, connecting and testing of OEM Manufactured APFC Panel capacity 200 KVAR (Output) @ 440Vac. The stage ratings shall be 2x12.5 KVAR +1x25kvar + 3 x 50 KVAR .The APFC Panel shall be fully type tested at an Independent Laboratory and shall comply with IEC 61439-1&2 and IEC 61921, IS-16636-2017.The degree of protection of enclosures system of the APFC Panel shall be min. IP41 in accordance with IEC 60529.The capacitor bank shall be Internet of things (IoT) enabled and communicable/ integrable with BMS The APFC Panel shall be (Indoor) type conforming to IS13341:1992 & IS 13440:1993 floor mounted design, weather, dust and vermin proof suitable for humidity up to 95%. Average daily temperature: +35°C max, Ambient temperature: -5°C to 40°C, Maximum altitude: 2000 m. Dimension 500x 800x 2325 with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. Make:- Rashtriya / Jayshree / BHEL or any ISI / Alpro. Approved Makes- ABB / Schneider / Siemens / L&T make only. The OEM's specified cannot authorize any other partners / sub vendors to manufacture APFC Panels on their behalf. The APFC Panel manufactured by OEM's only will be accepted & factory acceptance test ( FAT ) will be carried out at OEM's plant only. As equipment shall be comprising of the following:- (A) Insulated bus bar pan assembly made from Aluminium and rated of 400 Amps capacity. The short circuit withstand capacity shall be 50 KA / 1 Sec (Icw) for the main bus bar and the rated impulse withstand voltage shall be 6 KV. ( B) The incomer of the APFC Panel shall be a 400 Amp, MCCB, 3P, 50kA TMD type with O/L & S/C protection, Ics = 100% Icu, MCCB shall have standard extended rotary handle, spreaders, phase barrier. MCCB shall be of certified design confirming to IEC 60947-1,2 & 3. Approved Makes- ABB / Schneider / Siemens / L&T make only. (C) Capacitor Units: The capacitor unit shall be metalized polypropylene film with Zn / Al alloy. The capacitors shall be encapsulated in an aluminium can. The capacitor unit shall have a rated voltage of 525V and shall have a maximum over current capacity of: 2.5 In. The capacitor unit shall have a built in 3 phase over pressure protection and shall have discharge resistors (50V in 1min) factory fitted and shall be tamper proof. Capacitance Tolerance -5%, +10%. Maximum permissible over voltage 1.1 x Un, 8 h every 24 h. The capacitor unit shall be of certified design confirming to IS-13340-1993, 13341-1992 & IEC -60831-1&2. Approved Makes- ABB / Schneider / Siemens / L&T make only. ((D) Short-circuit and Overload Protection: Each stage of the APFC Panel shall have a suitably rated MCCB for short-circuit and overload protection. The over-current setting shall be adjustable & Breaking capacity Ics=> 36kA. The MCCB shall be of certified design confirming to IEC 60947-1, 2 & 3. Approved Makes- ABB / Schneider / Siemens / L&T make only. (E) PF Regulator/ APFC Relay: Advanced Range PF Regulator / micro-processor based APFC relay having 8 steps with a LCD Display, Voltage Range: 90V - 550V, 50 / 60Hz, CT Input: 1A/5A with a built in RS 485 communication port. The PF Regulator shall be of certified design confirming to IEC 61326. In addition to the PF Controller, the capacitor bank, should also have an energy server which would collect, store, and provides web access and visualization to various energy parameters and enable remote supervision from BMS. To ensure maximum utilization, enable remote commissioning / trouble shooting of the capacitor bank, the energy server should monitor and display the following parameters remotely through a Web Page.- Status of stages (open / close / faulty). Real time capacitance value of the connected stage. Initial capacitance value. Number of operation of stages ( stage utilization / operation), energy parameters like : I, V , P , Q, S , Operating PF, Target PF, Operating Temperature , Max Temperature, % THD V, %THD I, Display of alarms, Trending curves of historical recorded data. Approved Makes- ABB / Schneider / Siemens / L&T make only. (F) Stage Contactor: The capacitor duty contactors shall be rated for 230 Volts AC and shall be 3-pole type and shall be employed for switching 'on' and switching 'off' operations in capacitor banks. The contactor shall be AC- 3 duty type. The contactor shall be of certified design confirming to IEC 60947-1 & 4-1. Approved Makes- ABB / Schneider / Siemens / L&T make only. (G) Ventilating fans of required size shall be sued to dissipate the heat produced by the capacitor bank components like the capacitor units, reactors, contactors, breakers etc. The capacitor banks should be of type tested design and temperature rise test report of the capacitor bank performed at an independent laboratory should be submitted along with the offer. Note:-The APFC Panel described as above complete in all respect as per specification enclosed, up to the entire satisfaction of engineer In Charge.To ensure safety, reliability and accountability of component co ordination, all the major capacitor bank components such as capacitor units, de tuning reactors, PF controllers, circuit breakers, contactors and the enclosure system called for in this specification should preferably be from a single manufacturer. The OEM shall preferably manufacturer PFC components and switchgear. NS-3
21 Supply , Erection , testing & commissioning of 11 KV outdoor type HT Metering panel complete with CTs , PTs cubical and bidirectional electronics Meter with accuracy class 0.2 as per requirement / approved by UHBVN. Panchkula Electrical Supply consisting of following : NS-4 Cubical panel free standing floor mounting type made of sheet steel 14 G SWG CRCA sheet with channel iron base frame spray painted with strong synthetic grey channel paint as per size & design approved by UHBVN. PANCHKULA Electrical Supply.Out door Type with outer canopy.HSR No. i) 3 nos. 11 KV CTs of rating as approved by UHBVN Panchkula. Chandigarh Electrical Supply for indoor installation of appr.make of UHBVN Panchkula Electrical Supply. ii) 1 no. 11 KV PTs 11000/110 volts 10 VA burden 0.2 accuracy oil filled suitable for indoor installation of approved make of UHBVN Panchkula Electrical Supply. iii) Bidirectional Digital electronics meter 3 Phase 4 wire 11000 / 110 volts 10 VA burden 0.2 accuracy for recording reading of KWH of make and rating approved by UHBVN Panchkula Elect.Supply with push button display operating system for diff. kind of readings . iv) Foundation of Suitable Size 300mm above ground level made of CC having suitable size to hold metering panel v) Outer housing fab by 2mm thick CRCA sheet to cover the HT Metering Panel from rain water alongwith agnle iron frame. vi)
22 SITC of MS channel, angle iron and MS flat of different size on existing PCC pole for fixing & erection of transformer insulator cable also for making of the required size of tray for cable etc. including painting with two coat of approved paint and one coat of red oxide complete in all respect upto the entire satisfaction of Engineer-in-charge of work. NS-5
23 SITC of Heat shrinkable jointing kit / HT terminal box with tapex joint M-seal make including making necessary connections with transformer and HT metering panel with all required material thimble lugs & soldering compound tape etc. upto the entire satisfaction of Engineer-in-charge of work . Indoor for 50 sqmm , 3 - core (end termination tapex model) NS-6 (i)
Outdoor for 50 sqmm , 3 - core (end termination tapex model) NS-6 (iii)
24 SITC of 11KV gang operated switch Rashtriya / Jayshree / BHEL make conforming to IS with latest amendment including suitable size of copper blade erection of same on the existing 'H'pole with the help of 3 Nos. channels of size 75mmx40mmx6mm, 1.8M long fixed with suitable size of MS clamp, nuts and bolts including cost of 6 Nos. 11KV insulator with GI pin, RD fuses and painting with 2 coat of approved paint and one coat of red oxide material required to complete the job in all respect up to entire satisfaction of the Engineer-in-Charge of the works. NS-7
25 SITC of lighting arrestor model ALPRO / Alastom/ LEMCO make suitable for 11KV 3 Phase 50 HZ ground neutral system comprising of spare gape type queen gap type in series with non linger resistar element house in Horizontally scale poreclam bushing with line and ground terminal along with mounting clamps conforming to ISS 3070 (Part-I) of 1985 with latest amendment with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. NS-8
26 SITC of 11KVPin Insulator Brown colour with 11KV Gi Pin Jay Shree make with Disc fitting T&C type complete in all respect with erection of the same upto the entire satisfaction of the Engineer in Charge of work NS-9
27 SITC of Rubber mat of size 2mX1m & 12 mm thick suitable for 11 KV complete in all res. NS-10
28 SITC MS bucket stand which including cost of 6 nos. buckets of 9 liter capacity with sand filling including cost of welding & painting of complete stand & buckets with one coat of red oxide and two coats of approved paint of red colour with all labour & petty material to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work. NS-11
Som Nath Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .