Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAdmitted-Finance | ₹15.9 L | L1 | Admitted-Finance |
| 2 | L2₹20.0 L+₹4.0 L (25.4%)Admitted-Finance | ₹20.0 L+₹4.0 L (25.4%) | L2 | Admitted-Finance |
| 3 | L3₹21.2 L+₹5.3 L (33.3%)Admitted-Finance | ₹21.2 L+₹5.3 L (33.3%) | L3 | Admitted-Finance |
| 4 | L4₹22.0 L+₹6.1 L (38.5%)Admitted-Finance | ₹22.0 L+₹6.1 L (38.5%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | H.N.SINGH AND COMPANY L3 | ABTAR SINGH AND COMPANY L2 | Kamlesh L1 | JASPREET SINGH L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Transportation of Rig along with allied accessories etc. complete including erection and levelling at site, through all kinds of roads, approaches, fields etc. in all leads and lifts up to site of work complete in all respects as per the direction of the Engineer-in-charge. | 1 | No. | 30,000 ₹30,000 | 25,000 ₹25,000 | 15,000 ₹15,000 Lowest | 28,000 ₹28,000 |
| 2.00Earth work in foundation for digging tube well in all kinds of soil including dewatering, soring, strutting from ground level to 5 mtrs, including disposing of excavated soil including all leads and lifts complete in all respect as per the direction and to the entire satisfaction of Engineer-in-charge | |||||||
| 3.00Drilling of bore as per specification laid down in IS-2800-1991( part-1) method with upto date amendments if any with percussion Rig, direct rotary or combination drilling Rig starting with 650-600mm dia MS pipe reduced to 450-400mm dia MS pipe conforming to IS-4270-2001 with upto date ammendments, if any, in all kinds of soil such as boulders , rocks , collapsible strata, saturated soil, artesian condition including the cost of consumable stores, water, fuel , lubricants and other accessories etc. complete in all respect and as per the direction and to the entire satisfaction of Engineer-in-charge within all leads and lifts. | |||||||
| 3.01 | Drilling and lowering of MS casing pipes conforming to IS-4270-2001 with upto date amendments, if any of suitable sizes as mentioned above from 5-30 mtrs below ground level within all leads and lifts. (i) 0 to 5 mtrs | 5 | Mtrs. | 15,000 ₹75,000 | 14,500 ₹72,500 | 8,500 ₹42,500 Lowest | 16,000 ₹80,000 |
| 3.02 | Drilling and lowering of MS casing pipes conforming to IS-4270-2001 with upto date amendments, if any of suitable sizes as mentioned above from 5-30 mtrs below ground level within all leads and lifts. (ii) 5 to 25 mtrs | 25 | Mtrs. | 15,000 ₹3,75,000 | 14,500 ₹3,62,500 | 10,000 ₹2,50,000 Lowest | 16,000 ₹4,00,000 |
| 3.03 | Drilling and lowering of MS casing pipe conforming to IS-4270-2001 with upto date amendments, if any of suitable size as mentioned above from 30-60 mtrs below ground level within all leads and lifts (iii) 30 to 60 mtrs. | 30 | Mtrs. | 16,000 ₹4,80,000 | 15,500 ₹4,65,000 | 11,000 ₹3,30,000 Lowest | 16,000 ₹4,80,000 |
| 3.04 | Drilling and lowering of MS casing pipe conforming to IS-4270-2001 with upto date amendments if any of suitable sizes as mentioned above from 60-90 mtrs below ground level with in all leads and lifts (iv) 60 to 90 mtrs. | 30 | Mtrs. | 16,000 ₹4,80,000 | 15,500 ₹4,65,000 | 11,500 ₹3,45,000 Lowest | 16,000 ₹4,80,000 |
| 4.00 | Collection , preservation and display of suitable size sample box with top lid & locking arrangement till handing over of the tube well to the department complete in all respect as per the direction and to the entire satisfaction of Engineer-in-charge within all leads and lifts. | 1 | No. | 3,000 ₹3,000 | 3,000 ₹3,000 | 500 ₹500 Lowest | 2,800 ₹2,800 |
| 5.00 | Supply and lowering of IS marked electric resistance welded MS pipes 200mm dia nominal size housing 8mm thick having outside diametre 323.90mm screwed and scoketted conforming to IS 4270-2001 with upto date ammendments if any in a random length of 4 mtrs to 7 mtrs welded without any circumferential joints into bore hole in vertical position including cost of all scaffolding,derricks, poles clamps embedded in foundation etc including cost of all cutting, threadings, and welding of pipes etc complete in all respect as per the direction and to the entire satisfaction of Engineer-in-charge within all leads and lifts. | 80 | Mtrs. | 4,500 ₹3,60,000 | 4,200 ₹3,36,000 Lowest | 5,500 ₹4,40,000 | 5,000 ₹4,00,000 |
| 5.01 | Providing, Fabrication and lowering of MSERW pipe 300mm Dia MS slotted pipe 300mm nominal size housing 8.00 mm thick having outer dia 323.90 mm conforming to ISI-specification No. 4270-2011 with upto date ammendments if any about 4 mtrs to 7 mtrs in length should have 1600 slots per mtrs as per IS 8110-1985 of 75x1.57 mm slot size welded about any circumstances joints into the hole vertical position including cost of scaffolding derricks poles clmaps emmbended in foundation etc. complete in all respect and as per the direction and to the entire satisfaction of Engineer-in-charge within all leads and lifts. | 10 | Mtrs. | 5,500 ₹55,000 | 5,200 ₹52,000 Lowest | 6,500 ₹65,000 | 6,000 ₹60,000 |
Tender Value
₹20.4 L
EMD Value
₹38,100
Closing Date
5 Aug 2026, 11:00 amClosed
Executive Engineer
Jal Shakti Division Kangra
Installation of 1 No. Tubewell 90 mtrs. Deep at Birta (Garg Colony). (UNDER PDNA). ).
2026_HPIPH_139956_1
EE/JSDK/NIT/2026- 4148 - 97 Dt.25-07-2026
Open Tender
Civil Works
Item Rate
90 days
Kangra
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
₹38,100
14 Aug 2026
25 Jul 2026
5 Aug 2026
25 Jul 2026
5 Aug 2026
25 Jul 2026
25 Jul 2026 - 5 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Transportation of Rig along with allied accessories etc. complete including erection and levelling at site, through all kinds of roads, approaches, fields etc. in all leads and lifts up to site of work complete in all respects as per the direction of the Engineer-in-charge. | 1 | No. | - | - |
| 2Earth work in foundation for digging tube well in all kinds of soil including dewatering, soring, strutting from ground level to 5 mtrs, including disposing of excavated soil including all leads and lifts complete in all respect as per the direction and to the entire satisfaction of Engineer-in-charge | |||||
| 3Drilling of bore as per specification laid down in IS-2800-1991( part-1) method with upto date amendments if any with percussion Rig, direct rotary or combination drilling Rig starting with 650-600mm dia MS pipe reduced to 450-400mm dia MS pipe conforming to IS-4270-2001 with upto date ammendments, if any, in all kinds of soil such as boulders , rocks , collapsible strata, saturated soil, artesian condition including the cost of consumable stores, water, fuel , lubricants and other accessories etc. complete in all respect and as per the direction and to the entire satisfaction of Engineer-in-charge within all leads and lifts. | |||||
| 3.01 | Drilling and lowering of MS casing pipes conforming to IS-4270-2001 with upto date amendments, if any of suitable sizes as mentioned above from 5-30 mtrs below ground level within all leads and lifts. (i) 0 to 5 mtrs | 5 | Mtrs. | - | - |
| 3.02 | Drilling and lowering of MS casing pipes conforming to IS-4270-2001 with upto date amendments, if any of suitable sizes as mentioned above from 5-30 mtrs below ground level within all leads and lifts. (ii) 5 to 25 mtrs | 25 | Mtrs. | - | - |
| 3.03 | Drilling and lowering of MS casing pipe conforming to IS-4270-2001 with upto date amendments, if any of suitable size as mentioned above from 30-60 mtrs below ground level within all leads and lifts (iii) 30 to 60 mtrs. | 30 | Mtrs. | - | - |
| 3.04 | Drilling and lowering of MS casing pipe conforming to IS-4270-2001 with upto date amendments if any of suitable sizes as mentioned above from 60-90 mtrs below ground level with in all leads and lifts (iv) 60 to 90 mtrs. | 30 | Mtrs. | - | - |
| 4 | Collection , preservation and display of suitable size sample box with top lid & locking arrangement till handing over of the tube well to the department complete in all respect as per the direction and to the entire satisfaction of Engineer-in-charge within all leads and lifts. | 1 | No. | - | - |
| 5 | Supply and lowering of IS marked electric resistance welded MS pipes 200mm dia nominal size housing 8mm thick having outside diametre 323.90mm screwed and scoketted conforming to IS 4270-2001 with upto date ammendments if any in a random length of 4 mtrs to 7 mtrs welded without any circumferential joints into bore hole in vertical position including cost of all scaffolding,derricks, poles clamps embedded in foundation etc including cost of all cutting, threadings, and welding of pipes etc complete in all respect as per the direction and to the entire satisfaction of Engineer-in-charge within all leads and lifts. | 80 | Mtrs. | - | - |
| 5.01 | Providing, Fabrication and lowering of MSERW pipe 300mm Dia MS slotted pipe 300mm nominal size housing 8.00 mm thick having outer dia 323.90 mm conforming to ISI-specification No. 4270-2011 with upto date ammendments if any about 4 mtrs to 7 mtrs in length should have 1600 slots per mtrs as per IS 8110-1985 of 75x1.57 mm slot size welded about any circumstances joints into the hole vertical position including cost of scaffolding derricks poles clmaps emmbended in foundation etc. complete in all respect and as per the direction and to the entire satisfaction of Engineer-in-charge within all leads and lifts. | 10 | Mtrs. | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.46 MB
Form6and8.pdf
Tender Documents • 0.71 MB
termandconditions.pdf
Tender Documents • 0.10 MB
BOQ_207445.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .