Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.3 LAccepted-AOC H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹32.8 L+₹1.2 L (3.96%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹35.1 L+₹3.5 L (11.0%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹37.7 L+₹6.2 L (19.5%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹38.4 L+₹6.8 L (21.6%)Rejected-Finance 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | Raman Electric Trading Co L3 | M/S Sonu Traders L7 | R N Enterprises L2 | R D Bansal L4 | M/s Friends Engineering Works L8 | M/s AVINASH CHANDER GUPTA L6 | bharat contrectors L1 | The Rahul Vig L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of concrete poles/ struts, any size and type complete all as specified and directed. | 5 | Each | 100 ₹500 Lowest | 1,000 ₹5,000 | 400 ₹2,000 | 200 ₹1,000 | 500 ₹2,500 | 500 ₹2,500 | 500 ₹2,500 | 100 ₹500 Lowest |
| 2.00 | Dismantling of unserviceable cross arm such as MS channel /angle section etc complete all as specified and directed. | 1 | Quintal | 100 ₹100 Lowest | 500 ₹500 | 400 ₹400 | 100 ₹100 Lowest | 1,000 ₹1,000 | 2,000 ₹2,000 | 1,000 ₹1,000 | 100 ₹100 Lowest |
| 3.00 | Dismantling of ACSR or AAC conductors complete all as specified and directed. | 6.3 | Quintal | 100 ₹630 Lowest | 400 ₹2,520 | 400 ₹2,520 | 100 ₹630 Lowest | 1,000 ₹6,300 | 1,500 ₹9,450 | 500 ₹3,150 | 100 ₹630 Lowest |
| 4.00 | Dismantling insulators of any type and size complete all as specified and directed. | 161 | Each | 1 ₹161 Lowest | 2 ₹322 | 1 ₹161 Lowest | 2 ₹322 | 50 ₹8,050 | 50 ₹8,050 | 10 ₹1,610 | 5 ₹805 |
| 5.00 | Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc. complete all as specified and directed. | 250 | Running Metre | 5 ₹1,250 Lowest | 10 ₹2,500 | 10 ₹2,500 | 15 ₹3,750 | 10 ₹2,500 | 20 ₹5,000 | 10 ₹2,500 | 5 ₹1,250 Lowest |
| 6.00 | Excavation in trenches for laying under ground cable, erection of poles and stays in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed. | 506 | Cubic Metre | 90 ₹45,540 | 100 ₹50,600 | 80 ₹40,480 Lowest | 120 ₹60,720 | 130 ₹65,780 | 150 ₹75,900 | 100 ₹50,600 | 100 ₹50,600 |
| 7.00 | All as per Srl Item No. 06.00 here in before above but depth exceeding 1.5 metre and not exceeding 3.0 metre. | 1 | Cubic Metre | 100 ₹100 Lowest | 194 ₹194 | 120 ₹120 | 300 ₹300 | 500 ₹500 | 300 ₹300 | 120 ₹120 | 106 ₹106 |
| 8.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. | 320 | Cubic Metre | 20 ₹6,400 | 25 ₹8,000 | 5 ₹1,600 Lowest | 20 ₹6,400 | 30 ₹9,600 | 50 ₹16,000 | 30 ₹9,600 | 25 ₹8,000 |
| 9.00 | Removing surplus excavated material to a distance not exceeding 50 meter above the starting point complete all as specified and directed. | 187 | Cubic Metre | 20 ₹3,740 | 25 ₹4,675 | 5 ₹935 Lowest | 30 ₹5,610 | 30 ₹5,610 | 100 ₹18,700 | 30 ₹5,610 | 36 ₹6,732 |
| 10.00 | Material and labour for sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable) complete all as specified and directed. | 124 | Cubic Metre | 200 ₹24,800 Lowest | 450 ₹55,800 | 400 ₹49,600 | 350 ₹43,400 | 550 ₹68,200 | 800 ₹99,200 | 350 ₹43,400 | 300 ₹37,200 |
Tender Value
₹38.2 L
EMD Value
₹76,340
Closing Date
24 Jan 2026, 6:00 pmClosed
GE UTILITY AMBALA
GE UTILITY AMBALA CANTT 133001
SPECIAL REPAIR TO LT PANELS CABLES AND ALLIED WORKS FOR KHARGA OFFICERS MESS UNDER GE UTILITY AMBALA CANTT
2026_MES_746782_1
CA NO GE U AMB 74 OF 2025-26
Open Tender
Civil Works
Item Rate
240 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE UTILITY AMBALA CANTT
₹76,340
17 Feb 2026
1 Jan 2026
26 Jan 2026
1 Jan 2026
24 Jan 2026
16 Jan 2026
1 Jan 2026 - 8 Jan 2026
Dismantling of concrete poles/ struts, any size and type complete all as specified and directed.
Dismantling of unserviceable cross arm such as MS channel /angle section etc complete all as specified and directed.
Dismantling of ACSR or AAC conductors complete all as specified and directed.
Dismantling insulators of any type and size complete all as specified and directed.
Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc. complete all as specified and directed.
Excavation in trenches for laying under ground cable, erection of poles and stays in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed.
All as per Srl Item No. 06.00 here in before above but depth exceeding 1.5 metre and not exceeding 3.0 metre.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus excavated material to a distance not exceeding 50 meter above the starting point complete all as specified and directed.
Material and labour for sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable) complete all as specified and directed.
Supply and lay bricks, common burnt clay, sub class "B', old size, laid in perpendicular direction to cable as cable protection complete all as specified and directed.
Material & Labour for GI tubing light grade of size 80 mm dia fixed on walls / laid in trenches as protection pipe for under ground cable including provisioning of specials and clamps etc complete all as specified and directed. Note:- Excavation to be paid separately in respective items.
All as per Srl Item No.12.00 here in before above but for 100 mm dia.
All as per Srl Item No.12.00 here in before abov but for 50 mm dia.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Material and labour for cutting of bituminious road/ hard standing/PCC path/wall up to a size not exceeding 20cm width and not exceeding 60cm in depth for laying of protection pipe for cable including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1, 40 mm graded crushed stone aggregate upto existing surface level or removing any type of tiles carefully and refixing properly as per existing surface complete all as specified and directed.
Material & Labour for UG cable route indicator made out of 100 mm dia MS plate with 20 mm dia 50cm long MS bar as legs for writing LT and name of feeder fixing with and including necessary PCC 1:2:4 in grouting route complete all as specified and directed.
Supply and laying of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoued, electric power cable (heavy duty) 1100 volts grade with stranded aluminimum conductor of size 400 sqmm single core complete all as specified and directed.
All as per Srl Item No.18.00 here in before but of size 240 Sqmm 3.5 core.
All as per Srl Item No.18.00 here in before but of size 150 Sqmm 3.5 core.
All as per Srl Item No.18.00 here in before but of size 120 Sqmm 3.5 core.
All as per Srl Item No.18.00 here in before but of size 70 Sqmm 3.5 core.
All as per Srl Item No.18.00 here in before but of size 50 Sqmm 3.5 core.
All as per Srl Item No.18.00 here in before but of size 35 Sqmm 3.5 core.
All as per Srl Item No.18.00 here in before but of size 25 Sqmm 4 core.
All as per Srl Item No.18.00 here in before but of size 16 Sqmm 4 core.
All as per Srl Item No.18.00 here in before but of size 10 Sqmm 4 core.
All as per Srl Item No.18.00 here in before but of size 6 Sqmm 4 core.
Supply and erection of steel tubular swaged poles 9.0 mtr long complete with cast iron base plate, finial taper plug, bolts,nuts and screws as specified type 410 SP-31, providing synthetic enamel aluminium paint over one coat of red oxide primer and black and white strips with synthetic enamel paint 30 cm each alternatively upto 1.5 mtr above the coping of pole starting with black strip complete all as specified & directed. Note:- (i) Earth work and PCC shall be measured and paid seperately. (ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost.
Material & Labour for GI Bracket fabricated out of light grade GI tubing 40 mm dia or as per dia of fitting , 1.5 mtr long and along with 02 sets of suitable size of clamps and nuts and bolts to fix the bracket on Steel tubular pole 410 SP 31 complete all as specified & directed.
Material & Labour for drawing of PVC insulated and FR PVC Round Sheathed 1.5 SQMM, 3 core copper conductor ,industrial cable through steel tubular pole from bottom to Top hole and both side connection in Jn box MCB and Street light fitting complete all as specified & directed.
Supply and fixing of junction box insulated, of polycarbonate with glass fiber reinforced, size 205mm X 255mm X 112mm, environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive, rated for degree of ingress protection IP 66/67 in accordance with IEC 60529, gasket material of polyurethane and the gasket shall be internally embedded, compliing with requirements of the standards IEC 60998-1, IEC 60998-2-1, IEC 60670-22 & IEC 60670-2-5, including three phase busbar with 6 Amp MCB and mounting clamp and complying the instructions complete all as specified & directed. Notes:- (i) The manufacturer of junction box shall submit a copy of IEC certificate. (ii) For better safety the polycarbonate encl shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-11 DIN VDE 0304 Part 3, UL subject 94 for flammability V-2. (iii) It should be tested at glow wire test for 960 deg Cent. (iv) The impact strength of polycarbonate enclosures i.e. the degree of protection against mechanical load shall be in accordance with EN 50296-98 for IK 08. Manufacturer should submit routine test certificate for CJB/PJB. Make:-Hensel, cat part No DK 2525 G .
Material and labour for Plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation complete all as specified & directed.
Material and labour for PCC 1:3:6 type C1 using 20 mm graded stone aggregate for stay and coping for poles including necessary form work to exposed surfaces finished smooth and even complete all as specified & directed.
Material and labour for PCC 1:2:4 Type B-1 using 20 mm graded stone aggregate for coping of poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified & directed.
Supply, installing, testing & commissioning outdoor type cubical panel board of size as per manufacture design, outer shell made out of 3.15 mm thick CRCA sheet with 60 to 70% perspex sheet of min 3 mm thickness and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front and back openable double door system and cable alley (Each door hinged with body at 3 places should be welded with body and door) lockable/open able with arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl Copper bus bar of 800 Amp - 03 Nos and 400 Amp - 01 No bus bar for Nuetral, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:61439/2011 Part-1 and part -2 type test certificate with not less than IP-56 and breaking capacity 65 KA comprising of the following :- (a) MCCB 630 Amps, 36 KA 4 pole 415 Volts AC, adjustable type, (incoming)-01 No. (b) MCCB 200 Amp, 415 volt, 4 pole, breaking capacity 16 KA , adjustable type (Outgoing)-02 Nos. (c) MCCB 160 Amp, 415 volt, 4 pole, breaking capacity 16 KA , adjustable type (Outgoing)-02 Nos. (d) MCCB 125 Amp, 415 volt, 4 pole, breaking capacity 10 KA , adjustable type (Outgoing)-01 Nos. RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nos (e) Multi function meter for reading volt, Amp, KWH, Frequency etc including CT Coils complete - 01 Set (f) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, glands etc complete are included in quoted rates.
All as per Ser item No 36.00 here in before but Copper bus bar , 3 ph (RYB) of 600 A and 1 Ph (neutral) of 300 A and comprising of the following :- (a) MCCB 400 Amps, Amps 4 pole 415 Volts AC , 36 KA. - 01 No (Incoming) (b) MCCB 250 Amp, 415 volt, 4 pole, 25 KA , (Outgoing)-01 Nos. (c) MCCB 125 Amp, 415 volt, 4 pole, 25 KA , (Outgoing)-02 Nos. (d) Digital Multifunction meter with suitable size of CTs. -01 Set (e) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete are included in quoted rates.
All as per Ser item No 36.00 here in before but Copper bus bar , 3 ph (RYB) of 400 A and 1 Ph (neutral) of 200 A and comprising of the following :- (a) Change over switch 250 Amps 4 pole 415 Volts AC - 01 No (Incoming) (b) MCCB 250 Amps, Amps 4 pole 415 Volts AC , 25 KA. - 02 No (Incoming) (b) MCCB 100 Amp, 415 volt, 4 pole, 25 KA , (Outgoing)-05 Nos. (c) MCCB 63 Amp, 415 volt, 4 pole, 25 KA , (Outgoing)-01 Nos. (d) Digital Multifunction meter with suitable size of CTs. -01 Set (e) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete are included in quoted rates.
All as per Ser item No 36.00 here in before but Copper bus bar , 3 ph (RYB) of 100 A and 1 Ph (neutral) of 50 A and comprising of the following :- (a) Change over switch 63 Amp, 415 volt, 4 pole, front operated rotary type , (Outgoing)-01 Nos. (b) Incoming MCCB 63 Amps, 16 KA 4 pole 415 Volts AC, thermal and Magnetic Setting -02 No. (incoming) (c) Outgoing MCCB 40 Amp, 16 KA , TPN 415 volt AC -05 Nos (outgoing) (d) Multi function meter with KWH, voltage, Amp, frequency meter. Make AE/L&T/Havells (e) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, glands etc complete are included in quoted rates complete all as specified and directed.
All as per Ser item No 36.00 here in before but Copper bus bar , 3 ph (RYB) of 200 A and 1 Ph (neutral) of 100 A and comprising of the following :- (a) Change over switch 125 Amps 4 pole 415 Volts AC - 01 No (Incoming) (b) MCCB 125 Amps, Amps 4 pole 415 Volts AC , 36 KA. - 02 No (Incoming) (b) MCCB 63 Amp, 415 volt, 4 pole, 25 KA , (Outgoing)-02 Nos. (c) MCCB 40 Amp, 415 volt, 4 pole, 16KA , (Outgoing)-02 Nos. (d) Digital Multifunction meter with suitable size of CTs. -01 Set (e) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, cable glands etc complete are included in quoted rates.
Material & Labour for Encloser Frame-1 for MCCBs suitable to fix MCCB 63 A 4 Pole 16 KA-01 Nos complete all as specified & directed.
Supply & fix MCCB 40 Amp, 4 Pole 16 KA, suitable for frame -01 complete all as specified & directed.
Supply & fix bus bar chamber with copper bus bar 63 A, 4pole step type design, IP -42 protection complete all as specified & directed.
Material & Labour for Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface PVC conduit of suitable size / recessed as required on wall/ roof with 4x25.0 sqmm + 2x16.0 sq mm earth wire complete all as specified & directed. Note:- For measurement purpose 4x25 Sqmm + 2x16 Sqmm considered as 1 RM.
Material & Labour for Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface PVC conduit of suitable size / recessed as required on wall/ roof with 4x10.0 sq. mm + 2x6.0 sq. mm earth wire complete all as specified & directed. Note:- For measurement purpose 4x10 Sqmm + 2x6 Sqmm considered as 1 RM.
Supply & Fix Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 amp, 415 V complete all as specified & directed.
Material & Labour for earthing complete with galvanised earth plate electrode 600mm x 600mmx 6.00mm thick surrounded by charcoal and salt, burried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 25x4 mm GI strip earth lead by means of bolts, nuts, checks nuts and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm bore medium grade and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm bore GI pipe medium grade for watering and 40mm bore GI protection pipe (light grade), funnel, wire mesh, cast iron cover and frame etc including testing on completion complete all as specified and directed. Note :- (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance is more than 2Ώ the earthing will be redone at no extra cost.
All as per Srl Item No. 48.00 here in before but for connected to galvanised earth lead wire of 4.0 mm dia by means of GI nuts bolts, check nuts and washers and connected to earthing test point drawn through 15 mm bore GI pipe medium grade for protection of GI earth lead wire including 20mm bore GI pipe medium grade for watering GI funnel.
Note:- Amount of credit of Rs. 30962.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.00 MB
BOQ_836263.xls
BOQ • 0.55 MB
Tender.pdf
Tender Documents • 0.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .