Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹50.1 LAdmitted-Finance NO 3484 4TH H BLOCK 80FT ROAD BANASHANKARI 6TH STAGE RAGHUVANAHALLI RAGHUVANAHALLI BANGALORE KARNATAKA 560062 UDYAM KR 03 0043677 | BENGALURU URBAN | KARNATAKA | 560062 | ₹50.1 L | Admitted-Finance |
| 2 | Rejected-Technical R 233 6 SIR SYED ROAD 3 JOGABAI EXT OKHLA NEW DELHI DELHI 110025 UDYAM DL 03 0005486 07AALCA4396D1ZK B R M MII STATUS AS VERIFIED | SOUTH EAST DELHI | DELHI | 110025 | - | Rejected-Technical Non-Responsive to meet MQC of Tender |
| 3 | Rejected-Technical PLOT NO 13 SHAKTI KHAND II INDRAPURAM GHAZIABAD 201014 | GHAZIABAD | UTTAR PRADESH | 201014 | - | Rejected-Technical Disqualified as per clause no. 2.4.3(ii) of MQC of Tender |
| 4 | Rejected-Technical | - | Rejected-Technical Non-Responsive to meet MQC of Tender |
| 5 | Rejected-Technical | - | Rejected-Technical Non-Responsive to meet MQC of Tender |
| Sl No | Description | Qty | Unit | Gravity India Technologies Pvt Ltd |
|---|---|---|---|---|
| 1.01PART-I - SITC | ||||
| 1.02 | Supply of Factory-built Floor Mounted, Bottom discharge, Air Cooled DX (Direct Expansion) type CRAC/ PAC units for Server room application, equipped with most advanced industry technology to operate at higher return air temperatures (Scalable up to 38Deg C in case of additional load), guaranteeing precise control of Data Centres and server room. The units shall be selected on the basis of following parameters:
i) 25 kW (7.1 TR) of nominal cooling capacity and 23.8 kw of minimum net sensible cooling Capacity @ 4200 CFM
ii) 22+/-1 Deg. C/50% RH of return air
iii) Supply air in between 12.5 - 16 Degree. C
iv) 40 Deg. C of Design Ambient temperature.
Key Features of quoted model: a) Digital Scroll Compressor: with variable capacity results in better power saving. b) Backward curved Fan with EC Motor-which varies the speed based on temperature condition. c) Thermal Expansion valve. d) Evaporator Cooling coil: having better exchange and achieves Delta temperature of 10-12 degree C, suitable for Data centre application. e) HCR Air cooled condenser coil-with FSC which was varies the fan speed bases on data centre load and ambient condition. f) Microprocessor (ICOM) (Direct Panel mount Large Liquid Crystal Display as a factory installed), g) Heater. h) Infrared Humidifier. i) R410A Green Gas. j) G4 grade clogged Filters 95% down to 5 micron filter. k) BMS Configuration card. (Unity Platform card with all configuration), l) WLD (Water leakage detector) Sensor. Each unit footprint should not exceed Approx. 890(W) X 890(D) X 1970(H), Refrigerant: R410A Eco friendly. Warranty: 12 months from date of Commissioning | 3 | Set | 25,80,600 ₹30.5 L |
| 1.03PART-II - ACCESSORIES | ||||
| 1.04 | Supply and installation of Outdoor Stand/ MS Supportive Frame for each ODU unit (Each Stand limited to 25 KG each ) | 3 | Set | 37,500 ₹44,250 |
| 1.05 | Supply and installation of indoor MS stands with two coats of paint and required rubber pads including civil work. | 3 | Set | 37,500 ₹44,250 |
| 1.06 | Supply of eco-friendly R 410A Refrigerant. | 40 | Kgs | 54,000 ₹63,720 |
| 1.07 | Supply and fixing of 18G, 7/8 hard drawn Copper pipe size as per OEM recommendation with 9 mm thick nitrile rubber insulation. | 60 | Mtrs | 1,05,000 ₹1.2 L |
| 1.08 | Supply and fixing of 18G, 11/8 hard drawn Copper pipe size as per OEM recommendation with 9 mm thick nitrile rubber insulation | 60 | Mtrs | 1,05,000 ₹1.2 L |
| 1.09 | Supply and laying of 3 Core 2.5 sqmm Copper Armoured I/O communication cable for PAC units. (Interconnecting cabling between indoor and outdoor unit) | 70 | Mtrs | 36,400 ₹42,952 |
| 1.10 | Supply and laying of Incomer power cable 4C x 10 Sqmm Cu flexible to Indoor Unit with required MCCB. | 30 | Mtrs | 43,500 ₹51,330 |
Tender Value
₹38.1 L
EMD Value
₹89,814
Closing Date
14 Feb 2026, 3:00 pmClosed
EXECUTIVE ENGINEER ELECTRICAL
ADMIN BUILDING, NEW MANGALORE PORT AUTHORITY, PANAMBUR, MANGALORE
Supply, Installation, Testing and Commissioning of Precision Air Conditioner units in place of old units installed at Data Centre and Comprehensive Maintenance for the period of 3 Years
2026_NMPT_895517_1
NMPA/Mech/EE(E)I/2026/1648
Open Tender
Electrical Works
90 days
NEW MANGALORE PORT AUTHORITY, PANAMBUR, MANGALORE
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
FA and CAO, NMPA
₹89,814
Yes
6 Apr 2026
24 Jan 2026
16 Feb 2026
24 Jan 2026
14 Feb 2026
24 Jan 2026
PART-I - SITC
PART-II - ACCESSORIES
Supply and installation of Outdoor Stand/ MS Supportive Frame for each ODU unit (Each Stand limited to 25 KG each )
Supply and installation of indoor MS stands with two coats of paint and required rubber pads including civil work.
Supply of eco-friendly R 410A Refrigerant.
Supply and fixing of 18G, 7/8 hard drawn Copper pipe size as per OEM recommendation with 9 mm thick nitrile rubber insulation.
Supply and fixing of 18G, 11/8 hard drawn Copper pipe size as per OEM recommendation with 9 mm thick nitrile rubber insulation
Supply and laying of 3 Core 2.5 sqmm Copper Armoured I/O communication cable for PAC units. (Interconnecting cabling between indoor and outdoor unit)
Supply and laying of Incomer power cable 4C x 10 Sqmm Cu flexible to Indoor Unit with required MCCB.
Supply and laying of Humidifier Pipe as per required size.
Supply and laying of 25mm UPVC Drain pipe with insulation and end termination
Supply and fixing of UPVC ball valve for fresh water line.
Supply, Installation, Testing and Commissioning of Drain Pump Set.(1Working +1Stand by)
Supply and installation of Nitrile Rubber Floor Insulation sheet, Class ‘0’, 13mm thickness.
Supply and installation of Damper with Actuator including power supply cable.
Supply and installation of Mild Steel Powder coated, broken white, RAL 9010 60-80 microns), 70% opening Air grills suitable for 25mm thick False Floor Tile. a) Size: 600mm x 600 mm, b) Height: 25mm c) Material: Frame16G CRCA Sheet, Blades: 20G CRCA Roll formed slotted U channels or fabricated 18G CRCA slotted U Channels d) Point Load: 500Kgs e) Uniformly distributed load: 1500Kgs/Sqmtr. f) Face velocity: 2.75m/Sec g) Air quantity range: 1250 CFM
Installation, Testing and Commissioning of Bottom Discharge 7.1 TR – Direct Expansion Precision Air Conditioner Units by using Nitrogen Pressure Test, Vaccumizing, charging refrigerant and commissioning works including all necessary items with Civil work etc. as a complete job.
Dismantling of old Bottom Discharge 5.5 TR – Direct Expansion Precision Air Conditioner Units including Indoor/Outdoor units with all accessories and shifting to the Electrical Sub Division-I
PART-III - BUYBACK
Buy Back for old Bottom Discharge 5.5 TR – Direct Expansion Precision Air Conditioner Units including Indoor/Outdoor units with all accessories. Make: EMERSON Model No. : PEX120EC/DS with ICOM. Sl. no. : a) 13024120ED01 b) 13024120ED02 c) 13024120ED03 Part Code: 5060E0512003 Power Supply: 415V/3Ph/50 Hz
PART-III - CMC
Comprehensive Maintenance Contract for Newly installed Bottom Discharge 7.1 TR - DX (Direct Expansion) Precision Air Conditioner units after expiring one Warranty period - First year
Comprehensive Maintenance Contract for Newly installed Bottom Discharge 7.1 TR - DX (Direct Expansion) Precision Air Conditioner units - Second year.
Comprehensive Maintenance Contract for Newly installed Bottom Discharge 7.1 TR - DX (Direct Expansion) Precision Air Conditioner units - Third year.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_941258.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
TenderDocument.pdf
Tender Documents • 1.85 MB
BOQ_941258.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid