Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC WARD NO 11 THIRIYA NIZAWAT KHAN BAREILLY | BAREILLY | BAREILLY | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹29.6 L+₹12,000 (0.41%)Rejected-Finance | L2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L3₹30.0 L+₹53,900 (1.83%)Rejected-Finance C O MODERN FURNITURE B I BAZAR BAREILLY CANTT BAREILLY 243001 UP | BAREILLY | BAREILLY | UP | 243001 | L3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L4₹36.2 L+₹6.7 L (22.8%)Rejected-Finance VIKRAM COACHING GALI SUDAMA NAGARI MADI NATH BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L4 | Rejected-Finance Over all rates are higher than L-1. | |
| 5 | L5₹41.1 L+₹11.7 L (39.6%)Rejected-Finance 81 82 GHER SAIKH MITHOO KUBRHI PAKHAR ZAKHERA BAREILLY UP | BAREILLY | BAREILLY | UTTAR PRADESH | L5 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
31 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST BAREILLY
GE WEST BAREILLY
REPAIR/MAINT OF SUMMER APPLIANCES AT VARIOUS LOCATIONS UNDER GE (W) BAREILLY.
2023_MES_591716_1
8102/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE WEST BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE WEST BAREILLY
₹84,000
Yes
20 Jun 2023
27 Apr 2023
2 Jun 2023
27 Apr 2023
31 May 2023
11 May 2023
Amount
REPAIR TO DESERT COOLER (Summer King/AVIN/SummerCool/Khaitan /ANY OTHER MAKE)
Disconnection, taking down desert coolers from any floor of building and cleaning /removing of old paint and painting externally with two coats of Synthetic enamel paint of any colour as directed and internally with black bituminous paint as per existing complete all as specified and directed.
S&F of following spares parts of desert coolers of different sizes including testing and dismantling of old unserviceable one complete all as specified and directed.
Electric Fan motor of Desert/air cooler of capacity 1300-1400 RPM single shaft of power rating 100 - 150 watt 230 Volt 50 Hz Single phase Make- Summerking/Summercool/Khaitan
Water lifting submersible type tullu pump 18 watt and water lifting upto 1.8 Mtr for desert coolers Make- Summerking/Summercool
Float valve plastic ball for 15 mm dia bore of pipe of desert cooler with ISI mark.
PVC stop cock suitable for 15 mm dia GI pipe ISI Mark
PVC connection 15 mm dia with CP nut 450 mm long ISI Mark
Capacitor 4 MFD of make Usha/Asain/Epcos/ISI
Set of legs with clamp and nut bolt & washer for mounting of fan motor on body for desert cooler
Aluminium Fan leaf blade
PVC fan leaf blade
Iron Stand made out of iron of size 35x35x4mm for installation of desert cooler of height 3 to 6 feet, lengthxwidth as per site requirement on the ground floor / 1st floor / 2nd floor.
Switch regulator with controlling knob low, medium and high control of any size complete.
Wood wool pad, each packet set of three (Note: Tie strip for fixing of pads must be included in the quoted rate)
Wire mesh of Panel doors/side grills for supporting of Wood wool grass pad of size as required at site as per panel door size
PVC water distributor heavy duty 15mm size fixed with bolts & Nut & washers as required.
PVC elbow 15mm dia for inside water distribution
Front grill suitable for desert coolers
Plug top 3 pin 5/6 Amps, 230 Volt Make: Anchor/Schenider/Havells
Piano type switch 5/6 Amps, 230 Volt Make: Anchor/Schenider/Havells
Flexible Copper Cable 2 Core multistranded, PVC insulated of size 70/.0076 for internal wiring of desert cooler Make: Plaza/Havells/polycab
Two core connection lead cable, PVC insulated and sheathed Copper cable size 1.5 Sqmm complete all as specified and as directed Make: Plaza/Havells/Polycab
PVC flexible water tubing pipe of 15 mm dia heavy duty for desert cooler inside water distributing
GI Water tubing medium grade of bore dia 15 mm with all fittings for connection of Desert cooler water pipe line including fixing with clamp and fiitings complete.
GI sockets/union/elbow/tee of size 15 mm
REPAIR OF WATER COOLER 80/40,60/120,150/150, 150/180, LTR (Bluestar/Voltas /USHA/ANY OTHER MAKE)
Maintenance/ Servicing of water coolers 40/80, 60/120,150/150,150/180 Ltrs Capacity by removing , cleaning the dust and dirt and mud from water storage tank and tray and from the complete unit, cleaning of water tank, cleaning of condensing coil using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasing condenser fan motor etc re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning complete all as specified and directed.
Taking down/out by cutting unserviceable compressor unit from the machine of size 180/150/120/60/80/40 and of differnt capacity ltrs capacity including flushing out/cleaning of refrigerator system by CTD/Nitrogen gas.
S&F compressor (sealed unit) with charging of refrigerant gas complete and testing on full load for following capacity in Water Cooler all as specified and as directed. Make:LG / Emerson.
180/150 ltrs capacity of water Cooler
60/120 ltrs capacity of water Cooler
40/80 ltrs capacity of water Cooler
S&F in repair of following spares parts of water cooler of 40/80, 150/180, 120/160 Ltrs Capacity including testing complete after dismantling of old respective unserviceable spares.
Capacitor 36 MFD Make-Asian/Epcos/Siemns/ISI
Capacitor 10 MFD Make-Asian/Epcos/Siemns/ISI
Starting capacitor 80/100 Mfd of Make Unistar/Usha/Asian/ISI
Thermostat switch assly of suitable size Make - Indfoss/classic/danfoss
Overload protector Relay for water cooler of makes as above. Make- Indfos / classic / danfoss.
Blower motor 1/5 HP with mounting stand for water cooler of different capacity for water coolers
Fan leaf blade of blower motor for water cooler of different capacity for water coolers
Float valve complete with PVC ball and brass spindle for size 15 mm bore of pipe in water coolers of makes as above.
PVC connection with brass union nut 450 mm long suitable for 15 mm GI pipe in water coolers of makes as above.
Push cock (Push Tap) cast copper alloy chromium plated heavy duty complete of size 15 mm of suitable type as per site requirement
Drain pipe flexible including clamp for water cooler after repair of leakage of water tray all as specified and directed.
Plug top 3 pin 15 Amps, 230 Volt Make: Anchor/Schenider/Havells
Supply and fixing of Connection Pipe and socket for connection of Water cooler from Aquaguard /water purifier complete all as specified and as directed.
Repair to top cover of water cooler including replacement of rubber Gasket and locks complete including replacement of old nut and bolts, screws, hinges etc.
Repair to body of water cooler including water tray of any make/size capacity by welding of MS sheet not less than 1.6 sqmm thick to match with existing after removing old rusted/unserviceable portion including painting and replacement of old nut and bolts, screws, hinges etc.
M&L for removing of dents, putty filling, spray painting with two coats of synthetic enamelled paint after preparation of surfaces by burning of old paint for water cooler of size 180/150/120/60/80/40 ltrs storage capacity and any make complete all as specified and directed.
Repair to Split Type/Window Type AC 1/1.5/2.0 TON Make : (Carrier/ LG/ Haier/ Hitachi/ Bluestar/ Samsung/Panasonic/videocon/Voltas)
Maintenance and Servicing of split type air conditioner of capacity 1.5/2.0 TR of any make and type by removing , strip opening, cleaning the dust and dirt from the complete unit, cleaning of air filter, cleaning of condensing and cooling coil and complete outdoor and indoor unit using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasing of blower & condenser fan motor etc re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning.
Maintenance and Servicing of Window type air conditioner of capacity 1.0/1.5/2.0 TR of any make and type by removing , strip opening, and taking out the window type AC from the cabinet frame and cleaning the dust and dirt from the complete unit, cleaning of air filter, cleaning of condensing and cooling coil using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasing of blower & condenser fan motor etc re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning.
Taking down/out unserviceable sealed / rotary / Reciprocating type compressor unit from the outdoor unit of Split type AC/ Window type ACs of makes-Carrier/LG/haier/blue star/Voltas and any other make of capacity 1/1.5/2.0 Ton capacity including flushing of cooling system by Nitrogen gas.
S&F compressor (sealed unit) of following capacity in Split type/window type Air Conditioner complete and testing on full load all as specified and as directed by Engineer-in-ChargeMake:LG/Hitachi/Emerson/Carrier
(a) Reciprocating type 1.5 Ton
(b) Reciprocating type 2.0 Ton
(c) Rottery type 1.0 Ton
(d) Rottery type 1.5 Ton
(e) Rottery type 2.0 Ton
Supply, fixing , installation ,commissioning and testing of indoor unit complete with remote and valves of capacity 1.5 TR suitable for fixing up in the existing model of outdoor unit of Split ACs complete after disconnecting electrical connection and dismantling/ taking out indoor unit of split type ACs of any make and capacity from any place and fixing of the same after recharging of refrigerant gas including transportation cutting of hole on wall and making good of disturbed surface with matching colour/distamper all as directed by Engineer-in-Charge.Make: LG/Voltas/Carrier/Bluestar/Hitachi/Samsung
Ditto- all as above but of indoor unit capacity 2.0 Ton
S&F in repair of following spares parts of Split type/Window type ACs of capacity 2.0/1.5/1.0 Ton including testing complete after dismantling of old respective unserviceable spares
Remote suitable for various makes of Split type/Window ACs for 1/1.5/2.0 Ton capacity Make: LG , Carrier, Voltas, Bluestar, Hitachi
Condenser motor of outdoor unit for 1.5/2.0 Ton capacity of AC as per existing makes
Indoor motor of Blower for 1.5/2.0 Ton capacity of split AC as per existing makes
Condenser PVC blade of fan motor for 1.5/2.0 Ton Split AC
SP plug and socket in sheet steel enclosure including SP MCB 32 Amps Make : HPL/Havells/L&T
Running capacitor 50/2,/50/6 Mfd of suitable size make Epcos/Asian/Max/Sharda or equivalent as per ISI for ACs
Running capacitor 45 Mfd of suitable size make Epcos/Asian/Max/Sharda or equivalent as per ISI for ACs
Starting capacitor 100/120 Mfd of suitable size make Epcos/Asian/Max/Sharda or equivalent as per ISI for ACs
Indoor capacitor of size 1.5 MFD/2 MFD suitable for 1.5/2.0 Ton AC
Swing motor suitable for indoor unit of 1.5/2.0 Ton Split type AC
Contactor suitable for 1.5/2.0 Ton AC as per make/size approved by Engr-in-Charge . L&T/C&S/SIEMENS
Copper tubing of size 3/8" including cutting and brazing all as directed by Engr-in-Charge
Copper tubing of size 5/8" including cutting and brazing all as directed by Engr-in-Charge
Copper tubing of size 1/4" including cutting and brazing all as directed by Engr-in-Charge
Copper tubing of size 1/2" including cutting and brazing all as directed by Engr-in-Charge
Three core connection lead two single core, PVC insulated and sheathed Copper cable size 2.5 Sqmm including one earth wire of full guage complete all as specified and as directed Make : Plaza/Havells/Polycab
Nitril vinyl insulation foam suitable for fixing with copper tube of size 3/8", 5/8" , 1/2" and 1/4" and packing with wide pvc tapes of black/white colour compete all as specified and directed.
Reverse valve suitable for 1.5/2 ton ACs including dismantling and reinserting of valve and refilling of reqd refrigerant and testing all as specified and directed by Engr-in-Charge
Wall/floor mounting type iron stand for outdoor unit complete all as specified and as directed
Dead plug made out of brass of sizes 5/8" ,3/8" , 1/4" & 1/2" as per requirement on site for outdoor unit valves
Pin Valve made out of brass for compressor of ACs
Brass Thimble/U clip lugs made out of brass for internal connection & wiring of ACs of 100 pcs per Pkt
Suction valves made out of brass of size 5/8"/1/2"/3/8"/1/4" as per required for outdoor unit of split type ACs
Discharge valves made out of brass of size 5/8"/1/2"/3/8"/1/4" as per required for outdoor unit of split type ACs
Blower complete with fins suitable for indoor unit of Split type AC
Metal clad socket of 20 Amps 240 volts for AC complete all asspd and directed. Make:Havells/Schneider/Anchor/L&T
Metal clad Plug top of 20 Amps 240 volts for AC complete all asspd and directed. Make:Havells/Schneider/Anchor/L&T
Electronic PCB card complete with Display and sensor suitable for split AC indoor unit of any make as per requirement at site complete all as specified and as directed. Make: LG, Carrier, Voltas, Bluestar,Hitachi
Display unit with sensor suitable for split AC indoor unit of any make as per requirement at site complete all as specified and as directed. Make: LG, Carrier, Voltas, Bluestar
Unplasticised PVC pipes 25 mm outer dia of pressure rating 100 Kg/Cm2 for drain of water of split type ACs fixed complete to walls,ceilings or in floors etc, including chase cutting on wall & making good as per existing complete all as specified and as directed.
Air dust filter for indoor unit of Split type ACs for 1.5/2.0 Tonne capacity of ACs .
Relay for 1.5/2.0 Ton of makes Classic/Indfos/Annapurna for Split/window ACs
Thermostat Switch for 1.5/2.0 Ton of makes Classic/Indfos/Annapurna for window ACs as makes above.
Air dust filter for window type ACs for 1.5/2.0 Tonne capacity of ACs as per makes above.
Switch Controlling Knob complete with high, low and medium function for 1/1.5/2.0 Tonne capacity of window type Acs
Condenser motor for 1/1.5/2.0 Ton capacity of window type AC as per site requirement
Condenser PVC round Fan Blade for 1/1.5/2.0 Ton window type AC Make : Carrier/LG/Bluestar /Videocon/Onida/Samsung
Front grill suitable for 1.5/2.0 Ton window type AC Make : Carrier/LG/Bluestar /Videocon/Onida/Samsung
MCB SP 32 Amps 230 Volt used in the DB/MCB Enclosure Box of ACs
MCB SP 25 Amps 230 Volt used in the DB/MCB Enclosure Box of ACs
Supply and gas charging with refrigerent gas required in any make and type of split and window type ACs to its full capacity where less gas detected in the split type and window type air conditioners complete all as specified by Engr in charge
Taking down unserviceable PCBs card with sensors of Split/Window type AC and refix the same after complete repair and testing for 1.5/2.0 ton capacity AC's as directed by Engr-in-charge.
Taking down unserviceable condensor coil from outdoor unit of Split AC or from Window type ACs and Supply & Fixing and installation of condenser coil by brazing and testing complete by refilling the refrigerant gas after flushing with nitrogen gas complete all as directed by Engr-in-charge.
Shifting/Fixing by disconnecting electrical connection and dismantling/ taking out indoor and outdoor unit of split type air conditioning of any make and capacity from any place and installation, commissioning and testing of the same at another location including transportation, cutting of hole on wall and making good of disturbed surface with matching colour/distamper all as directed by Engineer-in-Charge.
Shifting/Fixing by disconnecting electrical connection and dismantling/ taking out window type air conditioning complete with frame cabinet of any make and capacity from any place and installation, commissioning and testing of the same at another location including transportation, cutting of hole on wall and making platform complete with wooden strip/iron frame for fixing of Window AC Cabinet and making good of disturbed surface with matching colour/distamper all as directed
REPAIR OF VOLTAGE STABILIZER 1/2/3/4/ 5 KVA (Bluebird/Blueline/Sinetrac/Vintec/ANY OTHER MAKE)
Opening/ stripping of voltage stablizer of capacity ranges 1 to 5 KVA make- Bluebird/Bluline/Sinetrac/Vintec/ V Guard/any other make for checking of components for their serviceablity as per makes above and repair to its internal circuits and wiring including minor repair to circuit plate and refix to its original position all as specified and directed
All as per above but for voltage stabilize of capacity 7.5 KVA
Rewinding of main transformer with super enamelled coper wire of suiltable size or guage including insulation material applying varnish and drying properly at slow temprature, , replacing nut bolts with washer including removing of burn wire of voltage stablizer single phase 220 V of 1 to 2 KVA complete all as specified.
All as per above but for 3 KVA.
All as per above but for 4 KVA.
All as per above but for 5 KVA.
All as per above but for 7.5 KVA.
S&F of following spares parts of Voltage stabilizer single phase of cap 2/3/4/5/7.5 KVA including testing complete after dismantling of old respective unserviceable spares
Trigger transformer of suitable for 2 to 3 KVA
Trigger transformer of suitable for 4 to 7.5 KVA
Circuit Plate 2 to 7.5 KVA
Volt Meter indicating 100 to 300 volt make AE for stabilisers as per make above.
Time Delay Relay System for 2 to 3 minutes with high cut above 250 volt and low cut 190 V in 2 to 7.5 KVA V/stablizer.
Circuit jack/ST3 socket for in out connection plate
Walk-in Coolers & Mortury cabinets MAKE :Bluestar/ANY OTHER MAKE
Maintenance/Servicing of Walk-in- cooler/Mortuary Cabinet of any size and type by removing , cleaning the dust and dirt from the complete unit, defrosting and cleaning of cabinet, cleaning of condensing coil using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasing condenser fan motor etc re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning
S&F in repair of following spars parts of Walk-in Coolers cold storage and mortury cabinets of different sizes including testing complete after dismantling of old respective unserviceable spares
Compressor (sealed unit) of cap 1.5/2.0 Ton/ esixting capacity in mortury cabinet/walk-in coolers cold storage complete and testing on full load all as specified and as directed
Electric blower motor of Walk-in Cooler cold room/mortuary cabinet for indoor blower unit of existing make and capacity complete with grills
Contactor switches of suitable sizes for outdoor units of walk-in coolers and mortury cabinets
Running capacitors of sizes 50/6 MFD for outdoor units
Indoor motor capacitors
Sub Zero Temperature Controller for Walk-in- Cooler Cold Storage Make -Danfoss/Thermo Sensors
S&F in repair of Mortuary Cabinet door handles with locks complete of existing makes and sizes and repair of dents and rusting in the mortury cabinet and testing complete re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning
M&L for repair of floor of walk-in cooler cold room by using suitable metallic flooring sheets and welding works and insulation thermocol materials works and refixing of matting and repair of dents and rusting complete all as specified and directed for proper cooling and smooth functioning
M&L for repair of door locks, handles and hinges of walk-in cooler cold room complete all as specified and directed.
Repair of PCB circuit plate including display card sensor & switches by disconnecting and refixing the same after complete repair and testing of walk-in cooler cold room by using suitable cement works and refixing of metallic flooring and repair of dents and rusting including repair of door locks complete all as specified and directed for proper cooling and smooth functioning
REFRIGERATOR 320/310/280/215/180/185/165 LTR MAKE: LG/ GODREJ/ Whirlpool/Kelvinator ANY OTHER MAKE
Repair and Maintenance of refrigerator of Capacity 165 to 400 Ltrs by removing ,strip opening, cleaning the dust and dirt from the complete unit, defrosting and cleaning of cabinet, re-assembling,dismantling the unserviceable parts & re-installing in the original position after replacement of U/S parts and testing for proper cooling and smooth functioning Make-LG/GODREJ /Samsung/Voltas/Whirlpool/any other make
Repair and Maintenance of deep freezers 310/320 Ltrs by removing , cleaning the dust and dirt from the complete unit, defrosting and cleaning of cabinet, cleaning of condensing coil using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasing condenser fan motor etc re-assembling, re-installing in the original position after replacement of U/S parts and testing and testing for proper cooling and smooth functioning Make-LG/Samsung/Voltas/Bluestar any other make
Taking down by cutting unserviceable Sealed/ rotary compressor unit from the refrigerator/deep freezer machine of size 310/320/300/280/215/170/165 litres capacity of MAKE LG/GODREJ /Whirlpool/ANY OTHER MAKE including flushing out refrigeration system such as condensor tubing capillery evaporator by nitrogen gas complete including cleaning .
S&F compressor (sealed unit) for following capacity in Refrigerators/Deep Freezers complete and testing on full load after recharging of refrigerant all as specified and as directed by Engineer-in-ChargeMake: LG/Samsung/Voltas/Whirlpool/Bluestar.
350/400/500 ltrs capacity deep freezers complete and testing on full load.
310/280 ltrs capacity refrigerators/deep freezers complete and testing on full load.
215 ltrs capacity Refrigerators complete and testing on full load.
180/165 ltrs capacity Refrigerators complete and testing on full load.
Supply and gas charging with refrigerent gas used for any type and make of water coolers,refrigerators,deep freezers,walk-in cooler/mortury cabinets to its full capacity where less gas detected in the Water coolers,deep freezers, refrigerators and walk-in-coolers/cabinets complete all as specified by Engr in charge
S&F of following spares parts of refrigerators/deep freezers of different sizes including testing and dismantling of old respective unserviceable spares complete all as specifed and directed.
Thermostat switch suitable for different capacity refrigerator Make: LG/Whirlpool/Samsung
Relay & Overload assembly universal type/Chip type complete suitable for all type of Refrigerators as per the existing model/size.
Freezer with door of suitable make and size as per the existing model/size.
Cooling coil cabinet complete for refrigerators of suitable make and size as per the existing model/size.
Door light switch (push button type ) with lamp holder of any make and size as per the existing model/size.
Electric blower fan motor of existing capacity in deep freezers
Electric bulb 15 watt 250 Volts AC or pin type of make Philips or equivalent
Evaporator/condenser coil assembly for capacity 165 to 310 Ltrs including brazing and fixing and testing complete
Capillary 0.33 mm dia of brass including brazing and fixing and testing complete
Magnetic door gasket/rubber beading for capacity 165 to 310 Ltrs
Taking down unserviceable PCBs card with sensors of Refrigerators of inverter model or any make and type and refix the same after complete repair and testing all as directed
M&L for sub main wiring with two single core 4.0 Sqmm (FRLS) copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 4.0 Sqmm (FRLS), insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. ( Note :- Two runs of 4.0 sqmm (FRLS), PVC conduit and one run of 4.0 sqmm (FRLS) copper conductor shall be measured as one unit length.)
Notes:- 1.The time limit for attending the job/complaints within 24 hour. 2. In case the contractor fails to attend/rectify the defects within the above time limit i.e 24 Hrs (excluding repair of Electronic PCB cards and replacement of compressor in which a specified time duration of 3 days required) penalty will be imposed as under :- Rs 200/- per day per complaints for first seven days after that Rs 500/- per day per complaint. 3. The representative of contractor shall report to the E/M refrigeration section complaint cell on all working days to receive the complaints. 4. A register shall be maintained by the contractor/his representative to record the complaints and its progress. 5. A separate Docket complaints slip book shall maintained by the contractor to note the complaints/jobs and get it signed by the user after completion of work and submit the same to JE-in-Charge on daily bssis. 6. Tenderers may note that amount of credit Rs 3,71,287.80 will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.
RAZA ENTERPRISES
D K THUKRAL AND SONS
M/s. S.S. Refrigeration, Bareilly
shahji contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .