NAME OF WORK : Providing and Erecting of Solar Roof Top Power Plant at City Control & Command Centre Badamdibaug with comprehensive
O&M Work for 10 years. (Re-Invite)
CAPEX WORK (WITHOUT GST RATES)
ITEM DESCRIPTION RATE (Rs.) PER TOTAL AMOUNT
ITEM DESCRIPTION RATE (Rs.) PER TOTAL AMOUNT
Supply, Installation, Testing & Commissioning of following size of Grid Tied Solar
Power Plant with Solar Panels (ALMM approved): Frame Material :
Anodized Aluminum alloy Frame With Twin Wall Profile, Front Cover : High
Transmission Low-Iron Tempered Glass (AR Coated), High efficency and
positive power tolerance Pmax: 0/+5, Module Efficiency should be
approx. 19.5%-22%, Normal operating temperature 45'C, Junction Box with
Waterproof IP67 & MC4 Compatible and Enclosed with Bypass diodes,
100% Electroluminescence test to ensure error free Modules, Thep. temp. co-
efficient of the PV module shall equal or better than - 0.45%/degree
C. Solar PV modules of minimum fill factor 75% to be used. Unit
Production:- More than 4.5 Unit /kw /day (Actual)(1Year Avg) With
year Product warranty and 25 year Linear Power Warranty includes all
mechanical and electrical parameters of the Solar panel. Modules must be
complied to the DCR(Domestic content requirements). The Ration of AC to
DC is 5:6 for the Installation capacity which are given in AC KW.
Solar Inverter: MPPT Range: MPPT Range: 80-1000 V , Max efficiency: 97.5% -
98.9%, O/p Frequency: 50/60Hz, Operating Altitude (m) ≤ 4000, O/p Power
Factor: ~1, O/P THDi: <3%, Operating Tempreture Range: -25~60°C, Integrated
protection of Inverter are Anti- islanding Protection, Input Reverse Polarity
Protection, Insulation Resistor Detection, Ground fault protection,
Residual Current Monitoring Unit, Output Over Current Protection,
Output Short Circuit Protection, Output Over Voltage Protection, PV array string
fault Protection. Protection Degree: IP65, User Interface LCD & APP,
Datalogger & Communication: GPRS / Wi-Fi.
Integrated, Input Reverse Polarity Protection Integrated, Insulation Resistor
Detection Integrated, Residual Current Monitoring Unit Integrated, Output Over
Current Protection Integrated, Output Short Circuit Protection Integrated,
Output Over Voltage Protection Integrated, Protection Degree: IP65, User
Interface LCD & APP,Datalogger & Communication: GPRS / Wi-Fi,
Module Mounting Structure: The mounting (Rectangular pipe / square pipe /
circular pipe) with requisite cross bars, nuts and bolts, etc. shall be Hot deep
galvanized with minimum 80micron coating. The Rectangular / square /circular
hollow pipe section used for the structure should have a minimum thickness of
2.0 mm. other than above, the material thickness should be minimum
mm. A certificate of a structural engineer certifying the strength and stability of the
mounting structure to withstand the weight and wind speed of 150 km/hour
throughout the life span of 25 years of the system, shall be submitted by the
vendors. Hot Dipped Galvanized steel coils.
suitable arrangement for base plate for foundation , solar panel mounting,
the structure should be suitable for carry the load of solar panel,wiring,
sprinkler system etc. with necessary foundation work/wall mount, j bolt,
anchor fastner etc. the nut bolt used for installtion of stucture should be
(SS 304) quality.The ground clearance of the bottom most edge of solar panel
shall not be less than 300 mm to 1200 mm or as per site’s
technical/feasibility requirement.
a. Column –The minimum section (thickness) should be 60MM*40MM
b. Rafter - The minimum section (thickness) should be 60MM*40MM
c. Purlin - The minimum section (thickness) should be 40MM * 40MM Balane
of System with necessary Swichgears (Suitabel size and protection of ACDB &
DCDB), inter connecting wiring, earthing system as per the CEIG drawing
approval, lightining arrester system as per the CEIG drawing approval, all
liasoning work with various gov. dipartment like state nodal agency, DISCOM &
CEIG is included in
(Excluding All charges namely GEDA Application fees, Solar connectivity
Charges, Meter connectivity Charges, Meter testing Charges and system
stability/strenthning
50 1 Grid Tied Solar Power System: 26 - 50 kW (3 - phase) 41739 per KW
2 2 Providing & Erecting HT Bidirectional meter as per MGVCL Norms. 15750 Each
1 3 Providing & Erecting LT Solar meter as per MGVCL Norms. 5040 Each
3 4 Providing & Erecting GPRS MODEM as per MGVCL Norms. 9450 Each
9 5 Providing & Erecting LT CT of 100/5 A as per MGVCL Norms. 1155 Each
Providing & Erecting Prewired with 3 TTB SMC (Sintex ) Enclosure with Fabricated
Metal Stand For HT BD Meter & Modem
OPEX WORK (WITHOUT GST RATES)
50 4 Operation and Maintanace work of Solar Roof Top Power Plant for 1st year 1356 per KW
50 5 Operation and Maintanace work of Solar Roof Top Power Plant for 2nd year 1397 per KW
50 6 Operation and Maintanace work of Solar Roof Top Power Plant for 3rd year 1438 per KW
50 7 Operation and Maintanace work of Solar Roof Top Power Plant for 4th year 1481 per KW
50 8 Operation and Maintanace work of Solar Roof Top Power Plant for 5th year 1526 per KW
50 9 Operation and Maintanace work of Solar Roof Top Power Plant for 6th year 1572 per KW
50 10 Operation and Maintanace work of Solar Roof Top Power Plant for 7th year 1619 per KW
50 11 Operation and Maintanace work of Solar Roof Top Power Plant for 8th year 1668 per KW
50 12 Operation and Maintanace work of Solar Roof Top Power Plant for 9th year 1718 per KW
50 13 Operation and Maintanace work of Solar Roof Top Power Plant for 10th year 1769 per KW
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Badamadibag Solar Tender -2.pdf
Price Bid Badamadibag Solar -2.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .