Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC C 247 1 RAJINDRA NAGAR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | L1 | Accepted-AOC Being 1st Lowest | |
| 2 | L2₹37.3 L+₹92,215 (2.54%)Rejected-Finance VILL BHAJNAI POST RAJPUR KALA TEHSIL ANOLA DISTT BAREILLY UP 243302 | BAREILLY | BAREILLY | UTTAR PRADESH | 243302 | L2 | Rejected-Finance Being 2nd Lowest | |
| 3 | L3₹37.5 L+₹1.2 L (3.25%)Rejected-Finance | L3 | Rejected-Finance Being 3rd Lowest | |
| 4 | L4₹37.8 L+₹1.4 L (3.96%)Rejected-Finance | L4 | Rejected-Finance Being 4th Lowest | |
| 5 | L5₹38.5 L+₹2.1 L (5.80%)Rejected-Finance 578 AVAS VIKAS JANAKPURI B IZATNAGAR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | L5 | Rejected-Finance Being 5th Lowest |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
1 Jul 2023, 6:00 pmClosed
GE EAST BAREILLY
Garrison Engineer East Military Engineer Services Shahjahanpur Road Bareilly Cantt
PROVN OF COVERED SHED ALONGWITH INTERLOCKING PATH FROM ADM BLOCK PERS LINE TO PERS COOK HOUSE AT 306 FD HOSP AND CERTAIN MINOR WORK UNDER GE (E) BAREILLY.
2023_MES_600802_1
8286E8
Open Tender
Civil Works
Item Rate
245 days
BAREILLY
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE EAST BAREILLY
₹94,000
Yes
21 Aug 2023
3 Jun 2023
3 Jul 2023
3 Jun 2023
1 Jul 2023
17 Jun 2023
3 Jun 2023 - 10 Jun 2023
Amount
Surface dressing n exc 15 cm deep complete all as specified and directed.
M&L Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in Soft/hard dense soils complete all as specified and as directed.
M&L Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in Soft / Hard dense soils, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed.
M&L for cement concrete (1:3:6) type D-2 using 20mm graded stone aggregate in foundation and filling around fencing post complete all as spd & directed (Deduction for the portion of fencing post / strut embeded in concrete shall be made) complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.50M above the starting point complete all as specified and directed.
M&L for brick work with fly ash bricks old size bricks in cement mortar, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) complete all as specified as directed
M& L for rendering 15mm thick in cement mortar (1:4),finished even and smooth using extra cement to on brick masonary wall surfaces or on other than fair faces of brick masonary finished even and smooth without using extra cement complete all as specified and directed.
M&L for Hard core broken brick gauge n exc 63mm, deposited spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed
M&L 75 mm thick PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub base floor / pavings complete all as specified and directed
M&L in repairs for machine pressed pre-cast concrete interlocking coloured paver block, Glossy finish and shape and size conforming to IS-15658-2006 of 80 mm thickness M-40 grade with grey cement and pigment laid dry over and including 50 mm thick stone dust or sand base and compacted using vibrator complete all as specified and directed.
M&L for cement Concrete coloured interlocking paver blocks shall be factory made with casting in rubber/pvc moulds & compacting on a vibro table assembly and shall be cured in curing tank for atleast 14 days and then air dried before use. The paver block shall be confirming to IS 15658 -2006 of 60mm thickness, M-35 Grade. Approved design, shape, size and colour of top layer Incl interlocking tiles laid over 50mm thick sand cushing and pattern and colour as approved by GE complete all as specified and directed.
M&L for PCC (1:2:4) type B1 using 20mm graded agg for machine pressesd precast cement concrete kerb stone including weathering, slightly rounded or chemferred angles and throating, as directed edges complete including excavavtion for kerb stone as directed.
S&F Stainless Steel plate rack of size 90x80x25cm made with 1.00 mm thick sheet complete all as specified. (Note:- Design /pattern of plate rack shall be approve by GE )
S&F Powder coated aluminium box section in Kitchen cupboard with side hung shutters fixed with & including aluminium composite panel LDPE core PET coating (both side decorative type ) fixed to shutter frame with powder coated aluminium beading clip & rubber gasket inside of the cupboards, frame made of powder coated aluminium box section & shelf tops & verticle partitions & back side made of alumnium composite panel fixed to frame with powder coated aluminium beading etc. Frame, shutter, shelves & vertical partition shall be made of size & material as appended below complete all as specified & directed (a) Frame :- Powder coated aluminium box section 85x44x1.48mm thick, fixing with wall face to be done with powder coated aluminium angle cleats & powder coated matching colour S S screws.(b) Shutters:- (i) Middle and lock rail: Powder coated aluminium box section 85x44x1.0 mm thick (ii) Bottom rail : Powder coated aluminium box section85x44x1.0 mm thick. (iii) Top rail/style : Powder coated aluminium box section 85x44x1.0 mm thick. (iv) Aluminium composite panel : 5.0 mm thick both side decorative type. (c) Shelves :- Frame : Powder coated aluminium box section 61.85 x31.75x1.0 mm thick in both horizontal & vertical sides, (ii) Aluminium composite panel : 4.0 mm thick both side decorative. (Note:- Shelf area per sqm of front measerable area shall not be less than 0.54 sqm , design of shelf to be approved by GE). (d) Powder coated aluminium beading : 0.7mm thick (e) Powder coated aluminium handle, tower bolt, (f) stopper , mortise lock 4 leaver( 02 Nos of each Kitchen cupboard) of approved make.Making good of wall surface to match with existing surface complete.with neccessary fittings all as spd as directed measurable area only front surface area of cupboard shutter . (Note:- Design / colour / pattern of aluminium composite panel & colour of powder coating shall be approve by GE )
S&F steel work in tubular trusses including special shaped washer etc.as in post,rafter and purlin complete using ERW or induction butt welded tubes confirming to IS 1161-1979 complete all as spd as directed
S&F Pre-coated galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as spd as directed
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for point wiring with FRLS PVC insulated, un-sheathed, multi stranded copper conductor cable of 1.5sqmm size, 1100 volts, drawn through & including concealed 20 mm rigid non metalic PVC conduit with all accessories fixed on wall/ceiling/truss including FRLS PVC insulated, unsheathed, multi stranded copper conductor cable of 1.5sqmm size as earth continuty conductor connected to common earth dolly including required numbers and size of sunk cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switches, switch sockets, sockets, regulators etc with 3 mm thick hylum laminated sheet cover including cutting Chases pinning in, for concealed conduit wiring and making goods of disturbed surface not exc 15 cm girth complete all as specified and as directed for:- NOTE: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit.
One light point / Fan point / Exhaust point / Bell point controlled by one 5A switch
One 5A flush type socket point on same board board
One 5A flush type switch socket point on independent board
All as per Srl item No.20 here in before but One 3 pin socket outlet 15 Amp independent with cable of size 2.5 Sqmm for wiring and earth wire
S&F switch piano flush type single pole one way 5 Amps Complete all as specified & as directed.
S&F Switch Piano flush type single pole one way 15 Amps complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 pin 5 Amp flush type complete all as specified and as directed.
S&F socket outlet 2 in 1, 3 pin 5Amp and 15 Amp complete all as specified and as directed.
S&F Lamp holder ( batten/angle ) PVC/Polycarbonate type with back plate for batten/angle fittings complete all as specified and as directed.
S & F in replacement of Ceiling rose, PVC/polycarbonate insulated body type, 3 terminal, 240 volts, 5 Amps complete all as specified and directed.
S & F Lamp LED heat sink white with polycarbonate diffuser, B-22 base cap, retrofit type, 220/230 Volts,7/9 Watt complete all as specified and directed.
S & F in repairs LED Tube light fittings 20 Watt (T-8 ), 4' complete with retrofit tube including connecting up with 3 core flexible copper conductor cable of suitable size Complete all as specified & as directed.
S&F in repairs LED bulk head luminaire hexafit 10 watt LED environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagonal bulk head back lit LED luminaries comprising of high brrightness LED complete all as specified & as directed.
M & L in repairs for sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through in & including PVC conduit complete all as specified and as directed.
S &F LED building security light fitting 25 Watt LED 230 Volts, AC outdoor type new generation with energy saving and environmental friendly long life made up of high pressure die cast aluminium housing with hight efficiency LED as lighting source and lens embedded and heat resistant polycarbonate cover having bottom opending seperate driver component with IP 66 protetection and impact resistant of IK07 complete all as specified and as directed.
S&F in repairs sheet metal enclousers (DBS) when MCBs to be used 8 way, 240 Volt, double door single pole & neutral with 200 Amps rated bus bar complete all as specified and as directed.
26. S&F in repairs MCB single phase and neutral 16A-63A, 230V 10KA. B' curve type complete all as specified and directed.
S&F in repairs MCB SP 6A-32A, 230V. 10KA. B' curve type complete all as specified and directed
28. S & F in repairs GI bracket made out from GI pipe 25/32mm dia, 1.20 m long fixed on wall with and including nut, bolts and GI clamps of size 25x4mm as required & including painting etc complete.
Supply and fix electric water heater storage type (geysers) steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 star rated complete will all accessories such as sefecty valve, thermostat, angle valve , NRV, connection pipe like hold and cold 450 mm long baraided hose with two 15 mm nuts and rubber washer ( 02 Nos for each geyser) suitble for geyser complete all as specified and as directed .
M&L for sub main wiring with 2 run of FR PVC insulated and unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alonwith one run of FR PVC insulated and unsheathed multistranded copper conductor of nominal cross sectional area 4 sqmm as earth continuity conductor drawn through in and incluiding PVC conduit all as directed.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified and as directed .
Supply and fix tube medium grade 15 mm dia will all fittings and fix complete to wall and ceiling or laid in floors complete all as specified and as directed.
Supply and fix stop bib tap cast copper alloy high pressure with crutch handle fancy type, screwed both ends for iron pipe or for union and fixed to 15 mm dia bore GI medium grade pipe complete all as specified and as directed.
Supply and fix amp rating 240 V, 10 kA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB with connection testing and commssioning 6 to 32 A complete all as specified and directed.
S&F sheet metal enclosres (DBs) when MCBs to be used 04 way 240 Volts double door single pole and neutral with 200 Amps rated bus bar complete all as specified and directed.
Supply and fix amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB with connection testing and commssioning SPN 63 Amps complete all as specified and directed.
Excacvation in trenches not exc 1.5 mtr wide and n exc 1.5 mtr in depth for laying of electric cable or water pipe etc n exc 10 sqmm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified.
Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed.
Supply and laying new dry river sand laid in trenches 8.0cm below the cable and 15cm above the cable and gently punned to 18.0cm as cable cushioning and covering complete all as specified and directed. (Note:- Only punned 18 CM thick sand cushioning shall be measured and paid)
Supply and lay cable XLPE insulated PVC armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor cross sectional area 16Sq mm 2 Core complete all as specified and as directed .
M&L for earthling complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directrly in ground (earth pit not less than 2.25 mtr deep blow GL with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layer of vharcoal dust and common salt filled in alternate layers and electrode connections by using Galvanised earth strip 32 x 6 connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 40 mm dia GI pipe light grade for protection of GL earth strip and 20 mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) type B1 chamber, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 Mtr, Provision of charcoal and slat complete all as shown in electrical plate No 3 of schedule SSR Part-I. Note : (i) Cost of GI earth strip and GI protection pipe upto 7.5 mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning filling, removing, PCC chamber pit RCC cover, test point etc.
NETRAPAL SINGH
N N ENTERPRISES
M/S SAJJAD HUSSAIN CONTRACTOR
UTTRAKHAND BUILDERS
Vasundhra Enterprises
Shikhar ji Enterprises
j u enterprises
Mohit Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .