| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC MANGALDAI | BARPETA | ASSAM | 781308 | L1 | Accepted-AOC Work Order Issued | |
| 2 | L2₹35.9 L+₹997.53 (0.03%)Rejected-AOC ASSAM AS | LAKHIMPUR | ASSAM | 784160 | L2 | Rejected-AOC L2 | |
| 3 | Rejected-Technical C O SRI HANUMAN PRASAD BAJAJ WARD NO 02 U T ROAD P O DIST UDALGURI BTC ASSAM | UDALGURI | ASSAM | 784113 | - | Rejected-Technical Non-Responsive |
| Sl No | Description | Qty | Unit | SRI PRANAB BARMAN L2 | BHUBANESWAR BARUAH L1 |
|---|---|---|---|---|---|
| 1.00 | 5.22 :Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more | 329.4 | Kg | 90 ₹29,646 | 89.65 ₹29,530.71 Lowest |
| 2.00 | 5.9 : Centering and shuttering including strutting, propping etc. and removal of form for
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts | 17.28 | Sqm | 804 ₹13,893.12 Lowest | 804.25 ₹13,897.44 |
| 3.00 | 5.9.5 Lintels, beams, plinth beams, girders, bressumers and
cantilevers | 12.07 | Sqm | 608 ₹7,338.56 Lowest | 608.35 ₹7,342.78 |
| 4.00 | 5.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm
nominal size) | 2.36 | Cum | 10,185 ₹24,046.79 Lowest | 10,185.05 ₹24,046.9 |
| 5.00 | 6.13 : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) | 79.32 | Sqm | 1,018 ₹80,747.76 Lowest | 1,018.05 ₹80,751.73 |
| 6.00 | 10.16 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
10.16.1 Hot finished welded type tubes | 165.07 | kg | 155 ₹25,585.85 | 154.9 ₹25,569.34 Lowest |
| 7.00 | 12.65 : Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless
steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work
shall be paid separately).
12.65.1 0.56 mm, Aluminium Color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. | 44.28 | Sqm | 1,058 ₹46,848.24 Lowest | 1,058.6 ₹46,874.81 |
| 8.00 | 13.5.1 : 15 mm cement plaster on rough side of single or half brick wall of mix:
13.5.1 1:4 (1 cement: 4 coarse sand) | 189.84 | Sqm | 354 ₹67,203.36 Lowest | 354.5 ₹67,298.28 |
| 9.00 | 9.3.1 : Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc.
9.3.1 Sal wood | 0.61 | Cum | 97,078 ₹59,411.74 Lowest | 97,078.35 ₹59,411.95 |
| 10.00 | 10/9.133.2.1 : Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).
12.26.1 6 mm thick Cement fiber board as per IS: 14862 | 48.8 | Sqm | 773 ₹37,722.4 Lowest | 773.4 ₹37,741.92 |
Tender Value
₹35.9 L
EMD Value
₹71,894
Closing Date
2 Aug 2025, 2:00 pmClosed
EE, PWD(B AND NH), UB Dist. Territorial Bldg Div
O/O The EE, PWD(B AND NH), UB Dist. Territorial Bldg Div
Repairing and Renovation of Udalguri Sahitya Sabha along with Drinking water facility at Udalguri
2025_PWBNH_45817_2
TECH/U_BDTD/BLDG/IFB/2025-26
Open Tender
Civil Works - Building
Item Rate
120 days
Udalguri
Please refer Tender documents.
5 documents required · 5 mandatory
₹720
₹71,894
Yes
O/O The EE, PWD(B AND NH), UB Dist. Territorial Bl
30 Aug 2025
22 Jul 2025
2 Aug 2025
22 Jul 2025
2 Aug 2025
22 Jul 2025
31 Jul 2025
Amount
5.22 :Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
5.9 : Centering and shuttering including strutting, propping etc. and removal of form for 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
6.13 : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
10.16 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes
12.65 : Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 12.65.1 0.56 mm, Aluminium Color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm.
13.5.1 : 15 mm cement plaster on rough side of single or half brick wall of mix: 13.5.1 1:4 (1 cement: 4 coarse sand)
9.3.1 : Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. 9.3.1 Sal wood
10/9.133.2.1 : Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). 12.26.1 6 mm thick Cement fiber board as per IS: 14862
9.1.2 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.2 Sal wood
9.9.1.2 : Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 19.9.1 Second class teak wood 19.9.1.2 30 mm thick
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): 21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
11.41A.3.1 : Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.1 Double charge vitrified tile polished finish of size 11.41A.1.1 Size of Tile 600 x 600 mm
16.12 : Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete:
11.3.1 : Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
13.88 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
13.43. : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer
13.44 : Finishing walls with water proofing cement paint of required shade: 13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
13.50 : Applying priming coat: 13.50.1 With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
13.61 : Painting with synthetic enamel paint of approved brarid and manufacture to give an even shade: 13.61.1 Two or more coats on new work
9.96 : Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm
9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 200x10 mm
9.100.2 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 9.100.2 100 mm
17.1.1 : Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres
16.78 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge. 16.78. With material conforming to Grade-II (size range 53 mm to 0.075 mm) having CBR Value-25
16.3 : Supplying and stacking at site. 16.3.3 : 53 mm to 22.4 mm size stone aggregate
1.3.4 Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fill up interstices of coarse aggregate, watering and compacting to the required density
16.91 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 16.91.2 : 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern
4.3 : Centering and shuttering including strutting, propping etc. and removal of form work for: 4.3.2 : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
4.4 : Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 4.4.1 1:14:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.22 A.6 : Steel reinforcement for R.C.C. work including straightening, cutting. bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
5.9.6 : Centering and shuttering including strutting, propping etc. and removal of form for 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
6.13 : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 : Cement mortar 1:4 (1 cement :4 coarse sand)
13.5 : 15 mm cement plaster on rough side of single or half brick wall of mix: 13.5.1 1:4 (1 cement: 4 coarse sand)
13.43. : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: 13.43.1 Water thinnable cement prime
13.44 : Finishing walls with water proofing cement paint of required shade: 13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
23.1 : Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part 1), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 23.1.2 : Rocky strata including Boulders 23.1.2.1 : 300 mm dia
23.3 : Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 23.3.1 : 100 mm nominal size dia
23.8 : Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
23.12 : Development of tube well in accordance with IS: 2800 (part 1) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
23.15 : Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 23.15.2 : 150 mm dia
18.43 : Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality.
18.46 : Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 18.46.5 : 40 mm nominal bore
18.9 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 18.9.1 : 15 mm nominal dia Pipes
18.9.3 : 25 mm nominal dia Pipes
18.9.5 : 40 mm nominal dia Pipes
18.19 : Providing and fixing gun metal non-return valve of approved quality (screwed end): 18.19.3 : 40 mm nominal bore 18.19.3.2 : Vertical
1.3 : Wiring for light-point/ fan point /exhaust fan point/call bell point with 2x1.5 sq mm. FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 15 sq mm FRLS PVC P insulated copper conductor single core cable etc as required Group C
Supplying and fixing following modular switch /socket on the existing modular plate & switch box including connections but excluding modular plate etc as required 1.24 1 : 5/6 A switch
1.24.4 : 3 pin 5/6A Socket outlet
1.24.3 : 15/16A switch
1.24.5 : 6 pin 15/16A socket outlet
Wiiing for circuit/submain wiring alongwith earth wire with following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required 1.14.2 : 2x2.5 sq.mm + 1x2.5 sq.mm earth wire
1,14.3 : 2x4 sq mm + 1x4 sq mm earth wire
1.14.4 : 2x6 sq. mm + 1x6 sq mm earth wire.
1.14.10 : 4x10 sq.mm + 1x6 sq mm earth wire
19.1 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos blades, 30 cm long down rod, 2 nos canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS 374-2019), THD less than 10%, remote or electronic regulator unit for speed E control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required
2.4 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but) without MCBs and incomer) as required (Note Vertical type MCB TPDB is normally used where 3 phase outlets are required) 2.4.1 : 4 Way(4+12) Double door
2.1 : Supplying & fixing 5 Amps to 32 Amps rating 240/415 V "C" Curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB Complete with connections testing & commissioning etc as required. 2.10 1 : Single Pole
2.13 : Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc as required 2.13.2 63A
5.2 : Earthing with GI earth pipe 45 metre long, 40 mm dia including accessories, and providing masonry cover plate having locking arrangement and with charcoal/coke and salt as required
5.7 : Supplying and laying 6 SWG GI wire at 0.50 metre below ground levelfor conductor earth electrode, including connection/ltermination with Gl thimble etc as required.
3.6 : Supplying, installation, testing and commissioning of following capacity overhead distribution bus trunking with aluminium bus bars having current density of 130 A/ sq cm at nominal current rating in 16mm thick IP 42 sheet steel enclosure in convenient sections with provision of tapping points for use on, 3 phase, 4 wire, 415 volts, 50 Hz, A.C. supply including jointing of sections, bends, earthing with 2 runs of galvanised iron strips, all installation accessories etc. as required. 200A
A-1 Supplying testing of 4 ft LED Tube light batten including all accessories as directed by he department (Philips make)
grade Solid aluminum conductor up to 10 sq mm balance strnded conductor, XLPE insulated, cores laid up, PVC tap innersheathed Armour (Aluminium wire for single core up to 70 sq.mm balance luminium strip Galvanised wire for cables up to 2x10 sq.mm Me 3x10 sq. mm 4x6 sq.mm and balance all galvanised steel strip) extruded PVC type ST2 sheathed 650/1100V grade as per IS 7908 (part-1) 1988 armoured U. G Cable as specified and direced by the department(Plaza or equivalent make as approved by this department) 35 sq.mm 3.5 core
A-3 : Supply, Testing, Commissining of 200mm sweep Ventilating fan, Exhaust fan complete as requird Prduct ID 5116877-8122534914
A-4 : Supplying Installation, Tsting and commissioning of Hi-Wall Invrier 5 Star 1.5 Ton rating non ducted split type Air-Conditioner with remote complete with copper pipe and complete electrical ennection as approved by the department up-to 5m between he room unit and out door Unit as directed by the department (Carrier /Blue Star/Daikin jor equivalent make)
A-5 : Supplying Installation. Tsting and commissioning of Voltage Stabilizer 4KVA for AIR-Conditioner as directed by the department (V-guard or quivalent make)
A-6 : Supplying with fitting and fixing of Single Phase Modular Motor Starter switch of the following specification complete including making necessary connection as specified and directed by the department Overload Relay Range 16-25 Amps in 3-Module
A-7 : Supply and Installation of 30W LED Solar Street Light consist of 75 KWP Solar module, life PO4 12 8 Volt 30 AH Battery, 6 meter GI Pole with necessary cables and hardwares including installation charge (Orient electric, NE navid Power, lokozo, Exide or MNRE Approved Brand)
A-8 : Supplying testing.commissioning of circular/Square LED surface ceiling light 18W including all accessories as directed by the department (Wipro or equivalent make)
A-9 : Load Security to be paid to APDCL (APDCL Norms)
A-10 : Supervision charge to be paid to APDCL (APDCL Norms)
A-11 : Supplying of following size of PVC/XLPE insulated and PVC sheathed1. 1KV grade Solid aluminum conductor up to 10.sq.mm balance strnded conductor, XLPE insulated, cores laid up, PVC tap innersheathed Armour (Aluminium wire for single core up to 70 sq.mm balance luminium strip Galvanised wire for cables up to 2x10 sq.mm 3x10 sq.mm 4x6 sq.mm and balance all galvanised steel strip) extruded PVC type ST2 sheathed 650/1100V grade as per IS 7908 (part-1) 1988 armoured U.G Cable as specified and direced by the department(Plaza or equivalent make as approved by this department) 16 sq.mm 3 core
A-12 : Supplying Fitting fixing of following size Submerssible Flat cable for Submerssible Pump
A-13 : Supplying and fitting fixingb of following size 3 HP Submerssible pump and panel /starter as specified and directed by the deptt (Kirloskar or equivalent make)
SRI PRANAB BARMAN (BID ID -273906)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .