Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC MUKALATH VALAYANCHIRANGARA PO PERUMBAVOOR ERNAKULAM KOCHI 683556 | PERUMBAVOOR | ERNAKULAM | KERALA | 683556 | L1 | Accepted-AOC L1 | |
| 2 | L2₹38.4 L+₹5.2 L (15.8%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹38.8 L+₹5.7 L (17.2%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹39.1 L+₹6.0 L (18.2%)Rejected-AOC 39 359 B PULICKAL THIRUVAMBADY POST ALAPPUZHA KERALA PIN 688 002 | ALAPPUZHA | ALAPPUZHA | KERALA | 688002 | L4 | Rejected-AOC L4 | |
| 5 | L5₹40.1 L+₹7.0 L (21.1%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
7 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
REPAIR/REPLACEMENT OF MISC EQUIPMENT AT NAD ALWAYE AND REPAIR/REPLACEMENT OF E/M INSTALLATIONS AND CONNECTED WORKS AT NAD ALWAYE AREA.
2023_MES_619031_1
8277/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
ALWAYE
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹70,000
Yes
12 Dec 2023
15 Sept 2023
9 Oct 2023
15 Sept 2023
7 Oct 2023
30 Sept 2023
15 Sept 2023 - 29 Sept 2023
Amount
Comprehensive maintenance of addressable fire alarm system installed at CNAI functionality of all components, cleaning all device , replacement of defective spares / components, comprising of following all as specified and directed :- Make : Morely. (a) Microprocessor based control Panel 2 Loop - 02 No. (b) Electronic siren - 02 Nos (c) Manual call points - 40 Nos. (d) Repeater Panels - 02 Nos. (e) 36 AH Battery - 02 Nos
Comprehensive maintenance of addressable fire alarm system installed at TSK comprising of following all as specified and directed: Make: Honeywell. (a) Microprocessor based control Panel 2 Loop - 01 No. (b) Electronic siren - 03 Nos (c) Manual call points - 54 Nos. (d) Repeater Panels - 02 Nos. (e) 36 AH Battery - 02 Nos Note for item No 1 & 2 :- a) Contractor Shall Maintain all the Documents and Produce to the Concerned Engineer in charge as and when required /preparation of RAR. b) Contractor shall give the Demo and training for all duty staffs about the fire alarm System. The unit rate quoted is deemed to be included for the Same. (c) Spares required for replacement, shall be measured separately as 'Supply only' under respective items.
Supply only addressable Manual call point resettable type complete all as specified and directed.
Supply only Detectors Complying with and type certified to EN - 45 Addressable type multisensory smoke detector with heat and smoke combination with base with self built intelligence as per IS: 11360 complete all as specified and directed.
Supply and fix Battery Maintenance free12 Volt 36 AH complete all as specified and directed.
Supply and laying Fire Alarm Cable of 2 core 1.5 sqmm FRLS armoured copper conductor cable complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of pipes, cables, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out soft/loose soil complete all as specified and directed.
Ditto all as per Serial Item No 7, but exceeding 1.5 metre in depth but not exceeding 3 metre.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and Labour for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate for filling of road cuttings etc all as specified and directed by Engineer-in-Charge
Supply & Fix single phase surge protection device type 1 & 2 tested for lighting impulse current 10/350 micro second 50 ka for phase to neutral and 125 ka for neutral to earth, surge protection device tested for nominal discharge current 8/20 micro second 20 ka phase to neutral voltage protection level,<=1.4kv, encapsulated spark technology for line to neutral for type 1 and metal oxide for varistor for type 2 line to neutral. LED indication in line to neutral pole in type 1 and flag indication in type 2 line to neutral, response time for type 1 is less than 100 nano second and type 2 is less than 25 nano second, DIN Rail mounted complete all as spcified.
Material & Labour for Earthing with copper earth plate of size 600 x 600 x 3.15 mm thick buried directly in ground not less than 2.25 metre below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150 mm in layers, connected by copper strip of size 20 x 3 mm thick, soldered and riveted to earth plate. GI earth strip will be protected by using 40mm bore GI pipe (light grade) earth plate to transformer body, LT feeder pillar box, and neutral of transformer etc complete. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20 mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 metre etc complete all as specified and shown in electrical plate No 3 of SSR Part I - 2009. Note: - Main earthing lead from earth plate to test point & up to 7.5 Metre to be provided. The cost for the same shall be deemed to be included in the above quoted rate.
Material & Labour for Earthing with galvanised Earth plate of size 600 x 600 x 6 mm thick buried directly in ground not less than 2.25 metre below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150 mm in layers, connected by iron strip of size 32 x 6 mm thick, soldered and riveted to earth plate. GI earth strip will be protected by using 40mm bore GI pipe (light grade) earth plate to transformer body, LT feeder pillar box, and neutral of transformer etc complete. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20 mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 metre etc complete all as specified and shown in electrical plate No 3 of SSR Part I - 2009. Note: - Main earthing lead from earth plate to test point & up to 7.5 Metre to be provided. The cost for the same shall be deemed to be included in the above quoted rate.
Ditto all as per Serial Item No 14, but using galvanised Earth plate of 600X600X6mm with iron strip 25X4mm as earthing lead.
Supply & Fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required Copper earth strip 20 x 3 mm with saddles/fasteners/insulators and fixing screws etc. complete all as specified
Supply & Fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required Galvanised earth strip 25 x 4 mm with saddles/fasteners/insulators and fixing screws etc. as specified
Ditto all as per Serial Item No 17, but GI strip of 32 x 6mm.
Material & Labour in replacement of test terminal block made of gun metal or phosphorus bronze size 75mmx75mmx25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws complete as directed.
Material & Labour 40mm bore galvanised steel tubing, Light grade, fixed on the top of the roof with socket/clamps or by welding etc. for fixing single point air termination rod for lightening conductor support as required at site including removing of the old rusted pipe complete as specified and directed.
Ditto all as per Serial Item No 20, but for 50 mm dia bore.
Material & Labour for steel tubular swaged poles complete with cast iron base plate, final tapper plug, bolt, nuts and screws as specified type 410 SP-31, 9 metre long and applying one coat of aluminium paint over a coat of red oxide zinc chromate primer including dismantling old one complete all as specified and directed.
Ditto all as per Serial Item No 22, but for SP 55 of 11 metre.
Supply & Fix in replacement of air termination single pointed copper rod 12mm dia 300mm long for lightning protection complete all as specified.
Supply & Fix in replacement of air termination single pointed aluminium rod 12mm dia 300mm long for lightning protection complete all as specified.
Supply & Fix in replacement of air termination single pointed aluminium rod 12mm dia 1 metre long complete all as specified.
Material & Labour for stay assembly complete with accessories comprising 20mm dia galvanised stay rod threaded end with nut 215cm long, 6mm thick MS stay plate of size 300x300mm, 2 Nos galvanised bolts, all as shown in electrical plate No 1 of SSR Part 1 and taking out old stay assembly all as specified and directed. (Excavation, PCC and insulator and stay wire will be measured separately).
Supply & Fix in replacement of galvanised stay wire of size 7/2.4 mm as required at site including necessary clamps, nut and bolts complete to hold the existing lightening arrestor pole in position complete all as specified.
Material & Labour for stringing aluminium conductor steel reinforced on tubular poles as suspension conductor for lightening protection system including removing of the existing old conductor complete all as specified.
Supply & Fix in repair Loop type insulator, vitreous porcelain, white, brown or green, Small size, with overall dimensions 65x90mm, clearance of hole 16mm complete all as specified.
Material & Labour for testing earth resistance between conductor and earth value for the building and lightening conductors including writing the date of testing, next due date of testing on the space provided. Testing will be done twice in a contract period after completion of 6 months from the first testing as directed by Engineer-in-Charge. (Note: After testing twice the quantity will be measured as one job).
Routine servicing, maintenance of DG sets upto 20 KVA of any make to be carried out including supply & replacement of lubricating oil filter elements, fuel filter elements, air cleaner element inner & outer with necessary 'O' Ring, Engine oil, making good any leakages of oil, greasing the shaft fan motor, bearings and testing complete all as directed by Engineer-in-charge. Note: Engine oil shall be measured and paid separately other parts are included in the quoted rates.
Ditto all as per Serial Item No 32, but of capacity 160 KVA.
Ditto all as per Serial Item No 32, but of capacity 500 KVA.
Material & Labour for dismantling of self starter 12/24V from engine and transporting to workshop for repair, opening cleaning and replacing defective bushes, bendex pinion ball bearing, plunger assembly, solenoid switch, carbon brushes, brush spring including varnishing of coils heating, drying etc for DG set up to 30 KVA complete all as directed.
Servicing /overhauling of Turbo charger by replacing TC kit including testing on completion of 30 KVA capacity Generator set.
Supply and replace fan belt suitable for 30 KVA capacity Gen set
Removing the old engine oil from the diesel engine sump of various DG sets, cleaning the oil sump thoroughly, supply and fill new engine oil multi grade OMD-110/20W 40/SAE 40 in replacement of old engine oil complete all as directed.
Supply and fix in repair AVR unit suitable for 20/30 KVA DG Set as per existing make and model
Repairs to rectifier unit of alternator and replacing defective diode, surge arrestor and its wiring and testing complete of up to 30 KVA DG Set complete all as specified.
Servicing of DG panel, cleaning, checking of electric connections, replacing defective components, meter, relays, indicating lamps, and all other control systems for the proper functioning of the panel of DG set upto 500 KVA complete all as specified.
Supply and fill coolant for radiator.
Material and labour for servicing of 20/30 KVA, 380 Volts online UPS by servicing of all parts, making all electrical connections, applying petroleum jelly to battery terminals, repair/replacement of battery leads, repair of parts, make the UPS Functional all as specified and directed by Engineer-in-Charge.
Supply and fix in repair burnt/unserviceable PCB of UPS suitable up to 30 KVA capacity at site as per existing make and model including dismantling old one complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair capacitor suitable for online UPS upto 30 KVA capacity at site as per existing make and model including dismantling old one complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair 3 phase Inverter mother board of UPS suitable for 20/30 KVA capacity at site as per existing make and model including dismantling old one complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair sealed lead acid battery of 12 volts, 65 Ah including taking down old unserviceable battery complete all as specified and directed.
Supply and fix in repair 3 phase sensing transformer of UPS suitable for 20/30 KVA capacity at site as per existing make and model including dismantling old one complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair 3 phase IGBT drive card of UPS suitable for 20/30 KVA capacity at site as per existing make and model including dismantling old one complete all as specified and directed by Engineer-in-Charge.
Servicing/Maintenance of electric/hand operated travelling crane removing old grease, dust, rust, cleaning with kerosene and apply new grease in all moving parts/bearings up to 5 Ton capacity.
Supply and replace Clutch assembly for up to 3 ton capacity of HOT Crane complete all as specified and directed.
Supply and replace Gear Arm suitable for up to 3 Ton capacity of HOT Crane complete all as specified and directed.
Load testing of Electric/Hand Operated crane by transporting dummy load from NAD Factory to the site where cranes load to be tested and vice versa of capacity up to 5 Ton all as specified and directed. Load test to be done by Govt approved firm/rep and test certificate to be submitted to the Engineer-in-Charge. (Note: Vehicle for transportation of load will be provided by NAD).
Supply and fix manual overhead crane hoist including operating chain up to 3 ton capacity.
Supply and fix manual overhead crane operating chain up to 3 ton capacity, crane height 5 to 18 meters, with locking arrangement including dismantling old one.
Material & Labour for painting of EOT/HOT cranes and their all components & machines as per MES colour code with one coat synthetic enamel paint including preparation of surfaces, writing of date of testing, due date of testing, capacity, SM/MES No etc, welding work on hand railing and brackets where broken of capacity up to 5 Ton complete all as specified and directed.
Supply & Fix 5000 Litres capacity Rotational mould polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position including taking down unserviceable tank complete all as specified and directed.
Supply and filling sand in trenches for covering and cushioning of cable in trenches complete all as specified and as directed. Note: - Punned thickness shall be measured and paid.
Supply & Laying unreinforced precast concrete cable cover ,class HV type 1 ,flat size 300 mmx180mmx40 mm complete confirming to IS -5820 OF 1970 for protection of cable complete all as specified and directed.
Supply, laying, jointing, testing & commissioning in pipes/ducts/trenches/under floor/under road HT XLPE cable insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (Heavy duty) with aluminium stranded conductor 11 KV 'Earthed' grade confirming to IS 7098 (Part II) of 1985 cross sectional area 240 Sqmm 3 core complete all as specified and directed.
Supply & laying in replacement Galvanised steel tubing of size 100 mm bore, light grade to be fixed on walls or laid under roads for passing cables complete as specified and as directed.
Material and labour for cable jointing kit (indoor termination) heat shrinkable type including all jointing material & accessories suitable for 11KV (Earthed) Cable aluminium conductor cables of size 240 to 300 Sqmm 3 core cables Including dismantling old one complete all as specified and directed.
Ditto all as per Item No 62, but for cables of size 120 to 185 Sqmm.
Material and labour for cable jointing kit (outdoor termination) heat shrinkable type including all jointing material & accessories suitable for 11KV (Earthed) Cable aluminium conductor cables of size 240 to 300 Sqmm 3 core complete all as specified and directed.
Ditto all as per Item No 64, but for cables of size 120 to 185 Sqmm.
Material & Labour in repair gang operated Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps including dismantling old one complete all as specified and as directed.
Supply and laying synthetic Rubber insulated mats 2.5 mm thick for voltage 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed
Supply & Fix lightening arrestor HT 11KV pole mounting metal oxide type complete with all fittings set transmission class nominal discharge current 65 KA including removing the defective one complete all as directed by Engineer in charge.
Material & Labour for preparation of old painted surface of Transformer 100 KVA to 500 KVA by removing all dirt, dust, grease, oil etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour including writing of identification Nos, capacity etc all as directed by Engineer-in-Charge.
Material & Labour for cross arm bracing support to clamps and back plate fabricated from structural steel section like angles channels flat etc including nuts bolts and washers welding bending cold or hot drilling holes for bolts if any shape and size and including applying two coats of aluminium paint over one coat of red oxide primer including dismantling old one and all as directed by Engineer-in-charge.
Supply and applying petroleum jelly on moving parts of GOD after removing carbon, dust etc complete all as specified and directed by Engineer-in charge
Material and Labour for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for LT, 25x20cm size.
Material and Labour hard core of gauge not exceeding 63mm deposited spread and leveled in layers not exceeding 15cm thick, watered and rammed to true surface broken stone or boulders or aggregate around 4 pole , 2 pole structure and transformer etc, complete all as per directed by Engineer-in-charge.
Material and Labour for servicing of HT VCBs, 11 KV 400/630 Amp capacity, indoor type by drawing out breaker assay from panel, cleaning/decarbonizing the contact points by suitable means, applying petroleum jelly, lubrication, adjust the trolley in and out mechanism and moving parts, testing of all tripping system and device, internal wiring circuit etc, tightening of all connections, replacement of HRC fuse (if any found unserviceable) engage the VCB with the supply system and testing for smooth function complete all as directed.
Material and Labour for calibration of protective relays both 02 Nos over current and 01 No earth fault relay of IDMT or any other type by using relay injection kit and re-set timing and tripping current according to the connected load all as directed.
Supply & fix Gear Assembly for VCB 400 Amps capacity including dismantling old one complete all as directed.
Supply & fix Limit Switch for Gear Motor for VCB 400 Amps capacity including dismantling old one complete all as directed.
Supply & fix Spring Charge Gear Motor for VCB 400 Amps capacity including dismantling old one complete all as directed.
Supply & fix Shunt Coil for Tripping and closing 110V DC including dismantling old one complete all as directed.
Supply & fix Spout assembly without contact point including dismantling old one complete all as directed.
Supply & fix PLA Relay 110V DC including dismantling old one complete all as directed.
Supply & fix Bridge Type Diode 25A including dismantling old one complete all as directed.
Supply & fix 11KV, PT Fuse 2 Amps including dismantling old one complete all as directed.
Supply & fix Cast resin type Potential Transformer Suitable for indoor VCB 11KV/√3/110/√3, A.C of Burden 100VA for VCB 400 Amps capacity.
Supply & fix Auxiliary switch NO/NC for VCB 400 Amps capacity.
Supply and replacing breather assembly of transformer with new silica gel suitable for any make of transformer of capacity 100 KVA to 400 KVA complete as specified.
Supply and replace brass terminal stud with nuts, check nut, oil seal and washer for HT side of transformer of any make as per sample for 100 to 400 KVA transformers complete as specified.
Supply and replace brass terminal stud with nuts, check nut, oil seal and washer for LT side of transformer of any make as per sample for 100 to 400 KVA transformers complete as specified.
Material and labour for filtration of insulating oil of transformer, voltage stabilizer’s etc in situation to bring the brake down value of oil not less than 40 KV at 2.5 mm gap including topping up of oil upto required level at different location all as specified and directed by Engineer-in-Charge
Material and labour for draining out old transformer oil from Transformer/voltage stabilizer and refilling of new transformer oil of BDV 60 KV dielectric strength when tested between 2.5mm gap electrical all as specified and directed by Engineer-in-Charge
Supply & Fix maintenance free battery 12Volt, 42AH including connection with UPS of VCB complete all as per directed
Supply & Fix in repair 1000 VA, UPS backup suitable for VCB 11KV, complete all as per directed
Material and Labour for drain valve of transformer 100 KVA to 400 KVA as per existing including dismantling old one complete all as specified and as directed by EIC
Material and Labour for replacing top cover gasket to transformer 100 KVA to 400 KVA complete all as specified and as directed Note :- Quoted rate also includes cost of body opening, re-fixing, nut bolts etc.
Supply and Fix in repair Street light timer panel of 12KW, 65AMPS, TP contactor with 63Amps, TPN MCB breaking capacity 10 KA preassembled in company fabricated, powder coated CRCA Box outdoor type along with fixing arrangement including dismantling old one complete all as specified and as directed.
Material and labour for PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate for erection of pole, etc all as specified and directed .
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
ELSOL ENGINEERS
M/s S & S Enterprises/ Suresh Shivasankarapillai
St George Engineering Works
S K ENGINEERS
LALA CONSTRUCTION
M/S AARJAY ASSOCIATES
KENZ CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .