Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹46.1 L+₹1.2 L (2.68%)Rejected-AOC | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹48.0 L+₹3.0 L (6.74%)Rejected-AOC SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L3 | Rejected-AOC Being not L1 | |
| 4 | L4₹48.3 L+₹3.4 L (7.56%)Rejected-AOC | L4 | Rejected-AOC Being not L1 | |
| 5 | L5₹48.9 L+₹4.0 L (8.91%)Rejected-AOC | L5 | Rejected-AOC Being not L1 |
Tender Value
₹49.8 L
EMD Value
₹99,600
Closing Date
15 Nov 2022, 6:00 pmClosed
Shri M Saravanan, IDSE, GE
Garrison Engineer North 35 Allenby Lines Secunderabad 500087
ADDN ALTN OF ROOF TREATMENT PLASTERING AND WIRING IN MD ACCN NO 122 01 TO 08 AT KARGIL LINE OF 26 MADRAS AND ADDN ALTN OF ROOFING TO BLDG NO 214 OF AMMUGUDA OTHER RANK MD ACCN OF 3 TRG BN 1 EME CENTRE UNDER GE NORTH SECUNDERABAD
2022_MES_558166_1
8634
Open Tender
Civil Works
Item Rate
180 days
GARRISON ENGINEER NORTH SECUNDERABAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER (NORTH) SECUNDERABAD
₹99,600
Yes
3 Jan 2023
17 Oct 2022
17 Nov 2022
17 Oct 2022
15 Nov 2022
1 Nov 2022
Amount
Demolition of cement concrete of any description and in any position not otherwise specifically provided in roof padding concrete complete all as specified and as directed.
M&L for PCC 1:2:4 Type B0 using 12.5 mm graded aggregate with water proofing compound @ 2% by weight of cement or as per manufacturer's instructions water proofing as in leveling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamferred on edges and formwork etc complete all as specified and directed. Note: Water proofing compound will be measured and paid seperately.
Material and labour for application of one coat of water based bitumen emulsion primer at the rate of 0.3 litres per square metre after cleaning of the surfaces thoroughly from dust, dirt and projections and applying water proofing treatment with APP based polymeric membrane of weight 3.5 Kilogram per square metre and minimum 3 mm thick reinforced with polyester non wove fabric (weight not less than 150 grams per square metre) as per IS 3384 on primed surface by forced application over roof surfaces with the over laps of 10 centimetres APP, membrane grit finish on roof slab all as per manufacturer's instructions and zonal specification etc complete all as specified and as directed.
Dismantling stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar complete all as specified and directed.
M&L for 20mm thick screed bed in CM 1:4 duly mixing with water proofing compound at the rate of 2% by weight of cement or as per manufacturer's instructions etc complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately under relevant item in this schedule
M&L for laying 300 mm x 300 mm x 20 mm thick PCC tiles (Hydraulically pressed) with grey cement, set, jointed, cut and polished. The joints shall be grouted and immediately after gouting, the joints shall be pointed flush in CM 1:3 mixed with 150ml per kg of cement of polymeric based lilquid water proofing additive by weight of cement or as per manufacturers instructions etc all as specified and directed. (Note : Supply of polymeric based liqluid water proofing compound will be measured and paid separately)
Supply only polymer based lilquid water proofing compound complete all as specified and directed.
M&L for making the grooves to 'V' section in existing parapet walls/columns over RCC roofs, cleaning out and tacked the polymeric membrane in to the grooves and sealed solidly with a hot mixture of bitumen and clean dry sand in the ratio of 1:1 by weight etc complete all as specified and directed.
Material and labour for rendering 10mm thick on roof surfaces in cement mortar 1:4 duly mixing with water proofing compound at the rate of 2% by weight of cement and finished even and smooth complete all as specified and as directed Note: Water proofing compound will be measured and paid separately under relevant item in this schedule
Supply only water proofing compound of ISI marked complete all as specified and as directed.
Taking down of old bituminous tarfelt or any other type of roof treatment from roof/ concrete surfaces and removal to distance exceeding 250 metres and not exceeding 500 metres from the site and cleaning of the roof surface with wire brush to make it free from dust, dirt etc complete all as specified and as directed
Material and labour for application of one coat of water based bitumen emulsion primer at the rate of 0.3 litres per square metre after cleaning of the surfaces thoroughly from dust, dirt and projections and applying water proofing treatment with APP based polymeric membrane of weight 3.5 Kilogram per square metre and minimum 3 mm thick reinforced with polyester non wove fabric (weight not less than 150 grams per square metre) as per IS 3384 on primed surface by forced application over roof surfaces with the over laps of 10 centimetres over that a coat of blown bitumen of 85 / 25 at the rate of 1.2 kilogram per square metre over that a coat of bituminous aluminium paint at the rate of 100 grams per square metre complete all as specified and as directed.
Dismantling water tanks and (exc 250 and not exc 500 ltr capacity) complete all as specified and directed.
M & L rotational moulded polythene water storage tank triple layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I capacity of tank 500 ltrs complete fixed in repairs complete all as specified and directed.
S & F in repairs 20 mm dia PTMT ball valves, high pressure, with polythene float and fly nut complete, screwed for Iron pipe or brass ferrule including taking down the existing valve complete all as specified and directed.
S & F 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairs including taking down the existing fitting complete all as specified and as directed
M & L for cement concrete 75mm thick type C-1 (1:3:6) using 20mm graded stone aggregate as in base of tank complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing complete all as specified and as directed
All same as per item No. 18 above but on 20mm dia complete all as specified and as directed
All same as per item No. 18 above but on 25mm or 32mm dia complete all as specified and as directed
All same as per item No. 18 above but on 40mm dia complete all as specified and as directed
S & F 15 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and directed.
S & F 20 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and directed.
S & F 25 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors.complete all as specified and as directed
S & F 40 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floorscomplete all as specified and as directed
S & F 25 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairs including taking down the existing fitting complete all as specified and as directed.
Taking down cement plaster on brick or stone walls/ceilings, etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M & L for rendering 10 mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement in patches n exc 3 sqm each patch complete all as specified and directed.
M & L for rendering 5 mm thick in cement plaster 1:3 on concrete surfaces of ceiling finished even and smooth without using extra cement in patches n exc 3 sqm each patch complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces in two coats (10 + 5 mm), both coat mixed with integral water proofing compound ISI Marked @ 2% by the weight of cement and finishing the surface even and fair complete all as specified and directed. Note - WPC shall be measured and paid separately
M&L for complete removal of existing treatment of old painted wall surfaces and applying 3.00 mm thick white cement based wall care putty smooth finish etc of approved make & shade on walls and other places of up to any height complete all as specified and as directed.
M&L for applying one coat of priming with alkali resistant priming paint over the putty surface and approved make & shade on walls of up to any height etc, complete all as specified and as directed.
M&L for applying two coats of oil bound distemper over the the above treated surface of approved make & shade on walls of up to any height etc, complete all as specified and as directed.
M & L for complete removal of existing treatment of wall and applying two coats of distemper oil emulsion on walls over 3mm thick wall care putty complete all as specified and directed.
M & L for preparing the old plastered or unplastered decorated surfaces of walls and applying two coats of white wash complete all as specified and directed.
M&L for new or previously untreated steel surfaces of any description, over 10 cm in width or girth, not otherwise described and apply two coats of synthetic enamel paint (ordinary tint) including priming with red oxide, zinc chrome complete all as specified and directed.
M&L for prepation of new or previously untreated wooden surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint including one coat of pink primer etc complete all as specified and directed
M & L for preparation of old painted wooden surfaces of any description over 10 centimetre width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparing newly plastered ceiling surfaces and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of newly plastered surfaces on walls, chajjas,filling of hair line cracks with white cement and applying two coats of apex ultima weather proof paint over a coat of apex ultima primer including preparation of surfaces etc complete all as specified and directed.
Material and labour for complete removal of the existing surfaces of walls/bands/slabs up to any height and applying two coats of weather proof paint of any colour over a coat of smooth external putty finish and a coat of exterior primer complete all as specified and as directed.
Dismantling of stone slabs or tiles of any description or thickness laid dry and pointed in any mortar, in floors, aprons etc complete all as specified and as directed.
Material and labour for 25 mm thick granite tiles (of any size) machine cut, jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone duly grinding and polishing laid over and including 15mm thick screed bed of 1:4 in steps, jambs, pillars, window cills, cooking platforms and like complete all as specified and as directed.
Material and labour for rounding and grinding of edges of granite platform both side rounded and grinding the stone complete all as specified and as directed
Material and labour for Non skid coloured ceramic tiles of size exceeding 0.06 sqm but not exceeding 0.11 Sqm of 7 to 8mm thick set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including cement screed bed of cement mortar 1:6 of 15 mm thick complete all as specified and directed.
Material and labour for non-skid ceramic coloured tiles of size exceeding 0.11 sqm but not exceeding 0.18 sqm of 7 to 8 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in white/coloured cement to match laid over and including 15 mm thick screed bed in cement mortar 1:6 including dismantling of existing tile complete all as specified and as directed
Material and labour for glazed ceramic highlighter wall tiles of approved colour of size 450x300x7 mm thick on vertical surfaces as in dado/wall set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 10 mm thick backing coat in cement mortar 1:4 including dismantling of existing tile complete all as specified and as directed
Demolition cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 10 mm wide grooves to full depth at 3 m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight and top 10 mm depth sealed with sealing compound grade ‘A’ complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar complete all as specified and directed.
M&L for 20-25 mm thick machine cut Polished kota stone as in treads of staircase laying down and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over bedding layer of 15mm thick in CM 1:6 complete all as specified and directed.
M&L for 20-25 mm thick machine cut Polished kota stone as in skirting / riser of staircase laying down and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over backing coat of 10mm thick in CM 1:4 complete all as specified and as directed.
Cutting down plants/trees of girth n exc 15 cm from roof tops/sides of external walls of buildings, chajja, wall junctions, junctions of rain water/soil/waste vent pipes including taking out roots entered in wall/slab surfaces and making good the surfaces including reparing the CI/GI/PVC joints of affected locations by applying TUFALO (Herbal medicine) and making good to suit the adjointing surfaces using PCC type 1:2:4, type B-0 or cement mortar 1:2 with necessary scaffolding/staging etc upto any height complete all as per manufacturer instructions complete all as specified and directed. NOTE: Any CI/GI/PVC pipes and fittings damaged during work shall be replaced by new one to ensure leakage/seepage free joint without any extra cost to the department.
Demolition of brickwork or stone/boulder masonry, built in cement mortar with all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles including disposal of the rubbish out off the premises complete all as specified and as directed.
Material and labour for brick work with fly ash bricks old size, straight or curved on plan exceeding 6.0 metre mean radius built in cement mortar 1:6 complete all as specified and as directed
Material and labour for brick work with fly ash bricks old size, straight or curved on plan exceeding 6.0 metre mean radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed
Taking down chowkats or frames with shutters (without taking off shutters from frames) of size exceeding 1.5 Square metre but not exceeding 4 square metre each complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) of size not exceeding 1.5 square metre each complete all as specified and as directed.
Taking down shutter of any description exc 1 Sqm and n.exc 2 Sqm each complete all as specified and directed.
S&F 125 x 60 mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
S & F pressed steel frame of size 105 x 60mm for doors with one or more rebates incl necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
M&L for PCC bed block in 1:3:6 type C1 using 20mm graded stone aggregate for back filling of steel chowkatws complete all as specified and directed.
M&L for cutting holes in brick wall built in cement mortor for inserting hold fast and making good the disturbed portion in cement mortor 1:3 depth of embeded portion exc half brick & n.exc one brick complete all as specified and directed.
S&F Rolled mild steel bands in steps, supports or stays for rain water, hooks (stay) heavy for large gates, hook and pintle hinges clamps, hold fasts wall ties, hooks for hanging james and similar small articles Fe-410-0 or Fe-310-0 complete all as specifed and directed.
S & F 35 mm thick factory made second class hardwood, plain framed panelled shutters (any number of panel) with panels of timber flat on both sides(feather edged) or of veneered particle board medium density wood particle board with commercial veneering on both faces complete all as specified and directed.
S & F 35 mm second class hard wood factory made glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars) edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc size of member of shutter as specified in SSR Part-I section 8 clause 8.24(a) etc complete all as specified and directed.
Supply and fix steel window with side hung double shutters of gauzed shutter openable inside and glazed shutter openable outside with projecting type hinges, steel handles and steel peg stay with glazing bars dovetailed or welded and ventilator fixed type complete all as specified and as directed.
M&L for mild steel in framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
Supply and fix in 4 mm thick sheet glass, ordinary quality and glazing with oil putty and glazing clips in metal frame and second class hard wood beading in suitable size for wooden frames of any size complete all as specified and as directed
Supply and fix in 4 mm thick figured glass, pin head type and glazing with oil putty and glazing clips in metal frame and second class hard wood beading in suitable size for wooden frames not exceeding 0.5 sqm in each pane complete all as specified and as directed.
Supply and fix Solid PVC door frame of size 50 x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube, all as specified and shown in Section 8 of MES Schedule Part-II 2020 complete all as specified and as directed
Supply and fix Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawings given in Section 8 of MES Schedule Part-II 2020 as applicable complete all as specified and as directed
S&F 150 mm extruded aluminium alloy hands, fabricated type, anodised complete all as specified and directed.
S&F 150mm aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 100 butt hinges extruded aluminium alloy with galvanised mild steel hinges complete all as specified and directed.
S&F MS sliding door bolts plate type stove enamelled black, with brignt bolt not less than 12mm dia with and including a minimum of 6 Nos bolt and nuts, four on bolt plate and two on staple plate of 300mm length of bolt complete all as specified and directed.
S&F for Mild steel 300 mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F in repair aluminium powder coated (fancy type) tubular curtain rod 20mm dia, complete all as specified and as directed.
S&F in repair bracket aluminium powder coated (fancy type) for 20 mm dia tubular curtain rod (for item above) complete all as specified and as directed
S&F for Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as specified and directed.
S&F in repairs vitreous china wash basin, white, flat back, size 580mm X 450mm including CI brackets, 32mm dia of brass chromium plated waste fittings with long screwed shanks and fly nuts flanged end bedded in red lead cement and other end fixed with & including cutting for & pinning in end of brackets and 15mm bore pillar tap, cast copper alloy fancy type chromium plated, screwed down high pressure complete all as specified and as directed.
Supply & fix in repairs Vitreous China Squatting pan, "Orissa" pattern, size 580 x 440 mm white with integral foot rests including connection to trap and to flushing pipe, anti-syphonage pipe etc., including trap set in and including cement concrete complete including making good to floor complete all as specified and directed.
S & F in repairs shelf of PTMT fixed with and including CP plated brass screws and wooden/plastic cleats (Minimum weight 105 gms) complete all as specified and directed.
S & F in repairs Towel rail 600mm long of PTMT fixed with and including CP brass screws and wooden/plastic cleats. (Minimum weight 190 gms) complete all as specified and directed.
S&F in repairs chromium plated shower roses 125mm size with or without swivel joint including fixing to steel pipe or union etc.complete all as specified and directed.
S&F in stainles steel sink with drainage board, 1 mm thick sheet of steel grade AISI 304 for kitchen or laboratory, with plug, waste pipe, washers and wastes including bedding in cement morter to dwarf wall or including fixing CI cantilever bracket, connecting union to pipe etc., overall size 915 x 460 mm with bowl size 410 mm x 330 mm x 160 mm etc complete all as specified and directed. Make : Nirali, Bule star ISI marked as approved by GE.
S&F stainless steel plate rack, wall mounted of size 750mm X 900mm X 200 mm of approved quality made of 1.00mm thick stainless steel for kitchen with necessary fixing material complete all as specified and directed.
S&F in repairs CP bib tap 15mm bore fancy type with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
Supply and fixed in repairs stop valve / angle cock fancy type cast copper alloy chromium plated with capstan head serewed down for 15 mm dia iron pipe complete all as specified and directed.
S&F UPVC/PVC (SWR) Nahani /Floor trap, 75 mm dia of out let, plain with grating including jointing to waste pipe with solvent and cement concrete type B1 (1:2:4) & including removing old trap and fixing of stainless steel grating in round shape etc complete all as specified and as directed.
S & F in repairs PVC 10 ltrs capacity symphonic action type low level flushing cistern including flush pipe, cantilever brackets incluiding taking down existing cistern etc complete fixed in repairs complete .
S&F PVC connections, 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S & F 110 mm bore UPVC/PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches including taking down of old pipes complete all as specified and directed.
Supply & fixing UPVC/PVC (SWR) junction single (single T ) equal or unequal 110mm dia with access doors complete all as specified and directed.
S&F 110mm dia vent cowl UPVC/PVC (SWR) complete all as specified and directed.
S & F 110mm bore UPVC/PVC (SWR) plain bends, any radius complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
M&L for 75mm thick cement concrete 1:4:8 type D-2 ( 40mm graded stone aggregate ) in sub base of floor complete all as specified and directed.
Spreading and levelling of sand/ grit cushioning below interlocking tiles complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block with grey cement and pigment (glossy finish) any shape & size conforming to IS 15658-2006 of 60 mm thickness, M-35 grade etc complete all as specified and as directed.
M&L for PCC 1:3:6 type C1 (using 20mm graded aggregate) in copings, kerbs, channels, water through and the like including weathering, slightly rounded or chamfered angles and throating as directed chamfered necessary for work complete all as specified and directed.
Dismantling of asbestos cement sheet /Plain or corrugated steel sheeting, (corrugated or semi corrugated) in roof covering complete all as specified and as directed.
Supply and fix pre-painted galvalume aluminium zinc coating galvanised based corrugated steel sheet of 0.50 mm thick of approved colour having tensile strength of 550 Mpa as roof covering/cladding to wall fixed with self tapping (SD) screws complete all as specified and as directed
Supply and fix pre-painted galvalume aluminium zinc coating galvanised based plain steel/corrugated sheet of 0.50 mm thick of approved colour having tensile strength of 550 Mpa as ridge, gutters fixed with self tapping (SD) screws complete all as specified and as directed
Dismantling timber Scantling framed work in fillets, rails, posts, rafters, purlins, etc. under 40 Sqcm in section complete all as specified and as directed.
Dismantling timber Scantling framed work 40 sqcm and over in section, in any position and removing store complete all as specified and as directed.
S&F Mild steel work in wind ties for roof including securing bolts including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 etc complete all as specified and directed.
Supply and fix rolled mild steel sections of Fe 410-W (GDE E-250) QUALITY “A” frame work as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates complete all as specified and as directed
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets or frame work complete all as specified and directed.
S & F E Grid suspended false ceiling grid system of size 600 x 600mm with main runner 39x29.7x0.60mm cross tee 29x24.7x0.60mm and wall angle 22.2x22.2x0.50mm ceiling suspended with 2 to 2.5 mm dia GI wire hanger fixed to purlin / truss etc complete (Main runner, cross tee, wall angle of MS galvanised with PPCGS) fixed to frames etc complete all as specified and directed.
Material and labour Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Alumi?nium framework etc complete all as specified and directed.
Material and labour except Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Alumi?nium framework etc complete all as specified and directed. Note : Non asbestos fibre cement building boards received from item no 110 tobe reused.
M & L for White wash in three coats on asbestos cement sheet surfaces or concrete surfaces as in ceiling including preparation of surfaces complete all as specified.
M&L for reinforced cement concrete(nominal mix) type B1 1:2:4 (using 20 mm graded aggregate) as in RCC bands supported on walls, beams and columns in floors,roof, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use and waste formwork to sides and soffits o floor or roof beams, beam haunhings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs,etc. also splays between floors and beams etc as in rough finished flat surfaces of concrete complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over including all cutting bending, binding, cranking placing & binding with MS wire (annealed) not less than 0.90mm dia complete all as specified and directed.
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders etc., including all cutting bending, binding, cranking placing & binding with MS wire (annealed) not less than 0.90mm dia complete all as specified and directed.
Material and labour for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 without using extra cement complete all as specified and as directed
M & L for preparing newly plasterd wall surfaces of walls and applying two coats of distemper oil emulsion over 3 mm thick wall care putty and a coat of primer using chalk whiting etc complete all as specified and as directed.
M & L for preparing newly plasterd wall surfaces and applying three coats of white wash complete all as specified and as directed.
M&L for complete removal of existing treatment on wall any applying 2 coats of weather proof paint over a coat of apex ultima primer including prepartion of surface complete all as specified and as directed. Make : Apex from Asian Paints or equivalent in All Guard from Berger, Weather Shield Max Exterior Acrylic from ICI Dulux
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified.
Material and labour for point wiring complete with stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLS conforming to IS - 694 multistranded CONCEALED with new sunk type pressed steel terminal boxes suitable for MODULAR switches including fixing/grouting sunken/ surface as per site requirement covered with suitable modular white cover plate for suitable size for mounting of MODULAR switches, regulators and drawing continuous earth wire with one run of 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLS conforming to IS - 694 multistranded copper conductor as earth wire and connecting to common earth dolly and making good the disturbed wall surfaces to match with the existing surfaces complete all as specified and as directed for the following :- (a) One light/ Bell point controlled by one, one way switch 5 amps, SP
All same as per item No. 124 above, but one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator complete all as specified and directed.
All same as per item No. 124 above, but one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and directed.
All same as per item No. 124 above, but one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and directed.
All same as per item No. 124 above, but one light point controlled by two, two way switch 5 amps, single pole complete all as specified and directed.
Description all as per item No. 124 here in before but using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated unsheathed 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sqmm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and as directed.
Supply and fix MODULAR switch 1 way 6 A, 1 Module 230 Volts complete all as specified and as directed.
Supply and fix MODULAR socket 5 pin 6 amps 2 MODULE, 230 Volts complete all as specified and directed.
Supply and fix MODULAR socket 6 pin 6/16 amps 2 MODULE, 230 Volts complete all as specified and as directed.
Supply and fix Switch MODULAR 1 WAY 16 amps, 230 Volts complete all as specified and as directed.
Supply and fix electronic ceiling fan regulator MODULAR 5 stepped type heavy duty suitable to work on 230 volts complete all as specified and as directed.
Supply and fix Modular bell push of 6 Amps SP, 230 volts AC complete all as specified and directed.
Supply and fix Switch MODULAR two way 6 amps, 230 volts, 1 module complete all as specified and directed.
S & F lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings fixed with wooden round blocks complete all as specified and directed.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and directed.
S & F ding dong Bell AC, 230 Volts, single pole complete all as specified and directed.
S & F wall mounted LED Batten,extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 1x20 W, 230 volts, bipin holders, DIFFUSED TYPE connector block, internally pre wired etc with necessary mounting arrangements including all accessories with new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed. Make: Havells Cat No-REGALBATTENT8UPTO 1X22WSSBSWH incl Tube Rod cat No-PHOTONULTRA2.01213T8SSTL20WLED865SPC, Wipro cat No WI0921208 incl Tube Rod LL13-181-65SE, Philips Cat No - TMC501P1xT-LED22WP3241 incl tube rod 20W.
S & F LED security light luminaire fitting of 1x35 watts with deep drawn housing including all accessories with suitable 40 mm dia GI bracket 0.60 Mtr length fixed on wall with 50x6 mm flat iron, clamps, nuts and bolts complete all as sepcified and as directed. Make: Havells Cat No - ENDCITYLITPLATE+ SL35WLED 757SASYBOPCWOSPD, Wipro Cat No LR13-501-XXX-57-XX, Philips Cat No - BRP030 LED35 CW MR PSU GR DX.
S & F Wall mounted light fitting suitable for 1x10 Watt LED Bulb complete with all accessories incl 01x 9 Watt LED bulb complete all as specified and directed. Make - Havells/Bajaj/Wipro
S & F wall mounted Indus plus LED Batten,extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 1x10w watts, 230 volts, bipin holders, DIFFUSED TYPE connector block, internally pre wired etc with necessary mounting arrangements including all accessories with new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting all as directed by Engineer-in-charge. Make:Havells cat No-LHEWEBP51N1W010 or equivalent in Philips/Wipro as approved by GE.
S & F sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with magnetic locking system complete all as specified and directed.
S & F MCB SPN 40 Amps 240 volts for fixing on MCB DB's complete all as specified and directed.
S & F MCB SP 6 to 40 Amps 240 volts for fixing on MCB DB's complete all as specified and directed.
M & F Submain wiring with 2 runs of single core 6 sqmm FRLS PVC insulated unsheated multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit concealed and conduit accessories of medium grade not not less than 25 mm dia including one run of single core 6 sqmm FRLS PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain rewing complete all as specified and as directed. Note: 3 runs of 6 Sqmm cable and one run of PVC conduit shall be measured and paid as one unit length.
S & F in replacement of Environmental fridendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs complete all as specified and as directed. Make: Havells RUGBYNEONFT10WLED860SSYMT OPC or equivalent in Bajaj/Wipro as approved by GE.
Material and labour for earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed. NOTE: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate in pit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, galvanised iron funnel with watering pipe, wire mesh, complete.
S&F in replacement of sheet steel MS enclosure earth plug socket 2 pin 20 amps with metal 20 amps with MCB 20 amps complete all as specified and directed.
Supply and fixing ceiling fans 1200mm, aluminium body, power consumption not more than 28W, BEE 5 star rated with BLDC motor, service value greater than 8.40 CMM/W, air deliver minimum 235 CMM, 350 RPM compatible with step regulator for speed control alongwith and including down rod, Canopy-2 Nos, electronic 5 step type regulator complete all as specified and directed. Make - Bajaj/Havells/Atomberg Note :- The following documents to be produced while approval :- (i) NABL test report (ii) BEE certificate (iii) BIS certificate (iv) Waranty cetificate for 5 years.
Supply and fixing Exhaust fan, steel body AC single Phase. 230V of size 230m sweep with, blades, and frame and louvers complete all as specified and directed. Make - Bajaj/Havells/Crompton
Dismantling/taking down old/UNSV distribution panel and supply, fixing and testing of out door 3 phase LT distribution panel board factory, made out of 3.15mm thick CRCA sheet CPRI approved of size not less than 600x450x200mm duly powder coated wall mounted/semi grouted in wall with locking arrangement single door type, compartmentalised and provision for tapping incomming & outgoing electric connections with suitable size of copper nut bolts & lugs, glands, one MCCB will be pre fitted/mounted on proper din rails and with earth link at top/bottom detachable plates and suitable for accomdating and including the the following items complete all as specified and directed:- (a) Copper busbar strips for TPN of 200 amps rating (min length of 250mm) and connected with MCCB by spreader terminals. ( set of 4 strips). (b) Phase indicating lamp LED type - one set of 3. (c) MCCB 4 pole, 63 Amps rating 25/26 KA breaking capacity, 415 volts - 01 No. ( Make: Havells/C&S/Standard)
S & F GI Tubes of size 40mm, 'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
SKY CONSTRUCTIONS
SAI RUPA CONSTRUCTIONS
K LAKSHMAN SINGH AND CO
BHEEMRAO PATIL CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .