Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹9.2 L+₹2.0 L (27.8%)Rejected-Finance | L2 | Rejected-Finance Reject |
Tender Value
₹5.6 L
EMD Value
₹11,300
Closing Date
14 Dec 2021, 11:00 amClosed
Executive Engineer Jal Shakti Divison Nahan
Executive Engineer Jal Shakti Division Nahan
Providing, Laying, Jointing and testing of MSERW/GMS pipe 65mm dia in rising main, Supply and errection of submersible pumping machinery with allied accessories Balsar side, Supply and errection of centrifugal pumping machinery with allied accessorie
2021_HPIPH_54405_1
NHN-SMROO-722-12501-580 dt 06/12/2021
Open Tender
Pumps/Motors
Item Rate
90 days
Nahan
Please refer Tender documents.
12 documents required · 12 mandatory
₹250
Executive Engineer Jal Shakti Division Nahan
₹11,300
Yes
5 Feb 2022
7 Dec 2021
14 Dec 2021
7 Dec 2021
14 Dec 2021
7 Dec 2021
Amount
Rising main
Excavation in drains and channels etc.in earth work in all kinds of soil such as Kankar Moorum,Shingles,Conglomerate saturated soil decomposed or soft rock &hard rock by blasting by chiselling (where blasting is to be prohibited) including dressing of sides and beds,disposing of excavated earth with all leads ,lifts disposed earth to be levelled and neatly dressed and then returning the stacked soil intofoundation and trenches etc. including ramming and consolidating the same whereever required with all leads, lifts and including jungle clearance and as per the direction of the Engineer Incharge
Laying,testing & commissioning at site in trenches following plain ended GMS Pipe of 65 mm dia of heavy and medium grade as under confirming to BIS 1239 -(PART-1) 1990 or lattest with up to date ammendments capable of withstanding requried test pressure as prescribed in BIS Code in random length of 5.5 to 6.5 mtrs. The pipe end shall be levelled sutiable for butt weld including the cost of jointing with butt welding confirming to IS 816-1969 or lattest applicable leal prrof in three layer at site of work with welding roof of standared make and all allied accessories whatever requried for welding at site tail pieces tees bend manfactured from parent pipe etc and cutting of pipe whatever requried as per site requriments and as per the directiuon of the Engineer in Charge
MEDIUM PIPE For Submersible Pump & R.Main Collection Tank to Sump well
Providing,welding and fixing M.S.Plate flange of 65 mm dia ( nominal bore) of following Flange table confiming to IS 6392-1971 or lattest with up to date ammendments to MSERW /GI Pipe after every 90 mtrs or as per site req-uirements including cutting of pipes wherever requried,welding in three layer (leak proof) confirming to specifuication as prescribed in relvent IS code i.eIS -816-1969 or latest as applicable with up to date ammendments with nuts,bolts,washers & special etc confirming to IS 1963 or lattest with up to date ammendments including packing sheet i.e.asbestos fibre sheet minimum3 mm thick and paintaing with antricorrosive paints complete in all respect including in all leads lift and carriage of material at site as per the directiuon of the Engineer in Charge
Buster Stage R.Main line
Flange Table - 5
Pumping Machinary (Bhudra Side)
Supply , errection and commissioning of sumersible pumping set of reputed make such as KSB/Calama/SU/BS/Johanston/Worthington make & model confirming to latest relevent BIS The pump should be fitted with free line impellers of suitable alloys as per BIS 5659 -1978 latest with up to date amendments suitable for raw/ clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection sleeve on pump side ensuring better life for shaft confirming to BIS specifications.The pump shall be along required length of column (column pipe shall be measured and paid for seperately )and along with a directly coupled submersible type squarrel cage induction motor o Kirloskar/NGEF/Jyoti/Crompton make conforming to relvant BIS codewith up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear & tear.It should also be fitted with a device to take up expansion of water with theheating of motor. The pump set should include water level guard,errection clamp, cable clips & depth gauge etc. & suitable for operation on data given below Head:- 258.00, Static Head: 242.70, Capacity 1.86 LPS, Dia of R/main: 65,,, Length g R/main: 910 mtrs, 2 x 12.50 HP = 25 HP
Providing and fixing of auto control panel with push button star delta starter ( 2Nos ) for submersible pumps of L&T and reputed make fabricated with M.S. sheet and angle stand duly painted and complete with internal wirring,complete with iternal wwiring,comprising of main switch of suitable Amp. T.P. Volt meter, phase indicating lamps with GSM based, remote start/stop operation call/SMS for feedback regarding running of pump & breakdown message ,timer scheduling for fixing hours in a day, Inbuilt protection against over load/undervoltage,Dry run,single phase preventor,inbuilt GPS tracker,phase reversal configurable volt/current limits a facility to access the system through minimum 10 nos. authenticated mobile nos.complete in all respect, including entire carriage of materials upto all leads and lift, installation and testing at site with entire satisfaction of Engineer in charge
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make of suitable size cast iron /Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main as mentioned in item No.1 (c) for withstanding nominal seat pressure as per item No.1(a)+ surge pressure. The size of reflaxe valve shall be equal to size of rising main of the same shall be provided with suitable bye pass arrangments
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Errection of all equipments of all stages i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Pumping Machinary (Balsar Side)
Supply , errection and commissioning of sumersible pumping set of reputed make such as KSB/Calama/SU/BS/Johanston/Worthington make & model confirming to latest relevent BIS The pump should be fitted with free line impellers of suitable alloys as per BIS 5659 -1978 latest with up to date amendments suitable for raw/ clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection sleeve on pump side ensuring better life for shaft confirming to BIS specifications.The pump shall be along required length of column (column pipe shall be measured and paid for seperately )and along with a directly coupled submersible type squarrel cage induction motor o Kirloskar/NGEF/Jyoti/Crompton make conforming to relvant BIS codewith up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear & tear.It should also be fitted with a device to take up expansion of water with theheating of motor. The pump set should include water level guard,errection clamp, cable clips & depth gauge etc. & suitable for operation on data given below Total Head: 259.00 Mtr, Static Head: 243.00 mtrs, Capacity: 1.83 LPS, Dia of R/main 65mm, Length of R/main : 1050 mtrs, 2 x 12.50 HP = 25 HP
Providing and fixing of auto control panel with push button star delta starter (2 Nos ) for submersible pumps of L&T and reputed make fabricated with M.S. sheet and angle stand duly painted and complete with internal wirring,complete with iternal wwiring,comprising of main switch of suitable Amp. T.P. Volt meter, phase indicating lamps with GSM based, remote start/stop operation call/SMS for feedback regarding running of pump & breakdown message ,timer scheduling for fixing hours in a day, Inbuilt protection against over load/undervoltage,Dry run,single phase preventor,inbuilt GPS tracker,phase reversal configurable volt/current limits a facility to access the system through minimum 10 nos. authenticated mobile nos.complete in all respect, including entire carriage of materials upto all leads and lift, installation and testing at site with entire satisfaction of Engineer in charge
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make of suitable size cast iron /Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main as mentioned in item No.1 (c) for withstanding nominal seat pressure as per item No.1(a)+ surge pressure. The size of reflaxe valve shall be equal to size of rising main of the same shall be provided with suitable bye pass arrangments
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Errection of all equipments of all stages i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Submersible Pumping Machinary
Supply , errection and commissioning of sumersible pumping set of reputed make such as KSB/Calama/SU/BS/Johanston/Worthington make & model confirming to latest relevent BIS The pump should be fitted with free line impellers of suitable alloys as per BIS 5659 -1978 latest with up to date amendments suitable for raw/ clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection sleeve on pump side ensuring better life for shaft confirming to BIS specifications.The pump shall be along required length of column (column pipe shall be measured and paid for seperately )and along with a directly coupled submersible type squarrel cage induction motor o Kirloskar/NGEF/Jyoti/Crompton make conforming to relvant BIS codewith up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear & tear.It should also be fitted with a device to take up expansion of water with theheating of motor. The pump set should include water level guard,errection clamp, cable clips & depth gauge etc. & suitable for operation on data given below Total Head:- 25.50 Mtrs, Static Head: 20.70 mtrs, Capacity :- 2.77 LPS, Dia of R/main : 65mm, Length of R/main:- 60 mtrs
Providing and fixing of auto control panel with push button star delta starter ( 2Nos ) for submersible pumps of L&T and reputed make fabricated with M.S. sheet and angle stand duly painted and complete with internal wirring,complete with iternal wwiring,comprising of main switch of suitable Amp. T.P. Volt meter, phase indicating lamps with GSM based, remote start/stop operation call/SMS for feedback regarding running of pump & breakdown message ,timer scheduling for fixing hours in a day, Inbuilt protection against over load/undervoltage,Dry run,single phase preventor,inbuilt GPS tracker,phase reversal configurable volt/current limits a facility to access the system through minimum 10 nos. authenticated mobile nos.complete in all respect, including entire carriage of materials upto all leads and lift, installation and testing at site with entire satisfaction of Engineer in charge
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make of suitable size cast iron /Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main as mentioned in item No.1 (c) for withstanding nominal seat pressure as per item No.1(a)+ surge pressure. The size of reflaxe valve shall be equal to size of rising main of the same shall be provided with suitable bye pass arrangments
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Errection of all equipments of all stages i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
shiv iron general engineers
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .