Tender Value
₹97.2 L
EMD Value
₹1.9 L
Closing Date
14 May 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
WORKS
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
(a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii)One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway.
Note for Technical Eligibility Criteria: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate
Definition of Single Similar Work: For the purpose of this work, Single Similar work shall be taken as per PCSTE/SR Letter No. SG.191/Similar Nature of work dated 25.02.2026 (Sl No.14 ) Any signal interlocking 1.1.1 works involving EI or RRI or PI or IBS or IBH or LC gate or yard modification or UFSBI or Track circuit (AFTC or DC TC) or Axle Counter (SSDAC or MSDAC or HA-SSDAC) or Automatic signalling
27 conditions · 3 needing a document upload
All the tenderers/Contractors have to deposit full Bid Security and tender document cost as stipulated for the tender, through online modes as permitted in IREPS application through multiple banks net banking, debit and credit cards . All documents related to Partnership deed/Joint venture/ Consortium/ MOU, duly signed by the notary public, should be uploaded failing which offer will be summarily rejected.
Until a formal agreement is prepared and executed, acceptance of this tender shall constitute a binding contract between us subject to modifications, as may be mutually agreed to between us and indicated in the letter of acceptance of my/our offer for this work.
I/We also hereby agree to abide by the Indian Railways Standard General Conditions Of Contract for works 2022, with all correction slips up-to-date and to carry out the work according to the Special Conditions of Contract and Specifications of materials and works as laid down by Railway in the annexed Special Conditions/Specifications, Schedule of Rates with all correction slips up to date for the present contract
I/We offer to do the work for DRM/S&T/TVC, at the rates quoted in the attached schedule and hereby bind myself/ourselves to complete the work in all respects within the period of completion stipulated in the tender document, from the date of issue of letter of acceptance of the tender. The amount as stipulated in the tender document is herewith forwarded as Bid Security. Full value of the bid security shall stand forfeited without prejudice to any other right or remedies in case my/our Tender is accepted and if : (a) I/We do not execute the contract documents as stipulated in performance guarantee clause of GCC for works 2022 as detailed in general instructions. (b) I/We do not commence the work within seven days after receipt of orders to that effect.
I/We hereby Confirm that the rates, rebates and/or other financial terms, if any, quoted by us in the relevant fields of the Financial Bid page will only be the ruling terms for deciding the inter-se ranking, and any such condition having financial repercussions, if quoted by us anywhere else including attached documents shall not be considered for deciding inter-se ranking
However, Railways shall have the right to incorporate any such condition quoted by us, in the contract, at their discretion, if contract is placed on us.
Manual submission of Bid Security and cost of tender form cannot be entertained/Considered and hence no need of uploading the scanned copy of financial instruments
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association Board resolution, failing which tender shall be summarily rejected. The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Appostille certificate.
INSTRUCTIONS TO TENDERERS
The tenderer shall thoroughly go through the entire tender documents and strictly adhere the instructions and directions given at different pages.
Tender Document Cost for this work is Nil.
Unreleased Bid Security, if any, held with the Railway Administration, shall not be adjusted towards the Bid security to be remitted.
If the Tenderer(s) deliberately give(s) wrong information/ incorrect documents in his/their tender or create circumstances for the acceptance of his/their tender, the Railway reserves the right to reject such tender at any stage. The entire Bid Security and any other dues available with Railway against that contract will be forfeited. Action will be taken to suspend the business with the tenderer for a period of two years. In addition, Administration reserves the right to prosecute under suitable law.
All terms and conditions in the tender documents are binding on the Tenderers.
Railways reserves the right to accept or reject any or all the tenders and to award the work in whole or in part without assigning the reason for any such action.
The Tenderers are advised to visit the site of work in their own interest and acquaint themselves with the site conditions and expected quantum of work and assess all the site specific difficulties to be experienced while executing the same and the rate shall be arrived duly considering all the facts above and quoted in the tender. Any representation at a later date specifying the site difficulties shall not be considered.
The bidder has to fill in his quoted rate against each item in the Bid rate / Unit rate column. If the bidding unit is Above/ Below/ Par, the bidder can select the %Above, %Below or %At Par option from the drop down list in the same column. If the bidding rate is Rs. or Rs./ unit, the bidder has to quote his rate for the item group or individual item accordingly
All the bidders/tenders should ensure that they are GST compliant and their quoted tax structure/rates are as per GST Law
In case of any wrong information submitted by tenderer, the contract shall be terminated, Bid security, Performance Guarantee(PG) and Security Deposit(SD) of contract forfeited and agency barred for doing business on entire Indian Railways for 2(Two) years
Provision of Interlocking arrangements including EOLB with SLB at LC 571 with more than 20,000 TVU in QLN-TVC section
TVC-SNT-SIG-25-26-39
TVC-SNT-SIG-25-26-39
Open
Works - General
10 Months
Thiruvananthapuram, Kerala
₹0
₹1.9 L
14 May 2026
21 Apr 2026
30 Apr 2026
96 items across 3 schedules · ₹65,41,918.12 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | " Te s t i n g a n d commissioning t h e RRI/PI signalling installations jointly with the Railway representative at site at the stations/ LC gates c o v e r e d u n d e r various schedules of the Contract and ensuring that all t h e signalling gears a r e installed and adjusted as per the existing rules. The work also involves supply o f required number of bound registers with good quality papers with all updated details of cable meggering, relays, batteries, block joints, route cancellation, r e l a y r o o m key entries, block instrument key, earth resistance etc., and handing over to Railways. (Supply of 'As mades' is not covered in this schedule)."Testing and commissioning of LC gates | LC Gate | 1.00 | 15,037.73 | 15,037.73 |
| 2 | "Submission of all relevent final 'As mades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As-made circuit diagrams also as mentioned above" | Sheet | 30.00 | 382.12 | 11,463.6 |
| 3 | "Supply of RTU of Capacity 64 Digital and 16 Analog as per RDSO spec .no IRS-S-99/2006 or latest including Power Supply and Back- up arrangements" | Numbers | 1.00 | 2,38,238.84 | 2,38,238.84 |
| 4 | Installation of RTU of Capacity 64 Digital and 1 6 Analog. T h i s includes transportation of materials t o S i t e location a n d provision of c a b l e t r o u g h a r r a n g e m e n t s including connection t o t h e BRC/Location earth. This also includes carrying out of pre-commission checklist and Networking of datalogger.(This schedule doesn't cover wiring and preparation of Simulation chart) | Per Unit | 1.00 | 21,650.89 | 21,650.89 |
| 5 | Supply and Provision of indicative type Class D Surge Protection Device for 24V DC/48V DC (spark gap type), with Potential Free contacts and installed as per the instructions of the Engineer i n charge a t s i t e ( OBO, DEHN, P H O E N I X , L P I , Z O T U P , H A K E L or better m a k e ) . A l l o t h e r miscellaneous materials required for installation shall b e supplied by the contractor. | Numbers | 10.00 | 6,328.8 | 63,288 |
| 6 | Supply and Provision of indicative type Class D SPD of Operating Voltage of 110V AC/DC with Potential Free contacts and installed as per the instructions of the Engineer in charge a t s i t e (OBO, DEHN, PHOENIX, LPI, ZOTUP, HAKEL or better make). All other m i s c e l l a n e o u s m a t e r i a l s required for installation shall be supplied by the contractor. | Numbers | 9.00 | 6,830.72 | 61,476.48 |
| 7 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 16.00 | 1,707.55 | 27,320.8 |
| 8 | Supply of 8-Channel Earth Leakage Detector as per RDSO Specifications RDSO/SPN/256/2002 or latest | Numbers | 1.00 | 1,10,759.06 | 1,10,759.06 |
| 9 | Installation o f 8 - C h a n n e l E a r t h Leakage D e t e c t o r. T h i s i n c l u d e s transportation of materials t o S i t e location a n d provision of c a b l e t r o u g h a r r a n g e m e n t s including c o n n e c t i o n t o t h e B R C e a r t h . Also includescarrying out of pre-commission checklist. | Numbers | 1.00 | 11,320 | 11,320 |
| 10 | "Supply of OFC Patch cord (FC-PC/SC-PC/LC- P C t o FC-PC/SC-PC/LC-PC s o a s t o s u i t for switches and FMS supplied)" | Metre | 10.00 | 374.03 | 3,740.3 |
| 11 | S u p p l y a n d installation o f 2 4 Fi b r e Joint enclosure f o r armoured optical fi b r e cable c o n f o r m i n g t o RDSO spec.RDSO/SPN/TC/68/2014 rev2.0 or latest | Numbers | 2.00 | 13,647.37 | 27,294.74 |
| 12 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. The lettering on the cable marker shall be "SIG" / "TELE" / "OFC" as per t h e instructions o f Railway representative at site.) as per drawing enclosed | Numbers | 80.00 | 262.65 | 21,012 |
| 13 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) | Metre | 2350.00 | 64.1 | 1,50,635 |
| 14 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.5 Mtrs. (Laying of cables is not included in this schedule.) | Metre | 750.00 | 79.51 | 59,632.5 |
| 15 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 340.00 | 208.54 | 70,903.6 |
| 16 | Provision of GI pipes (50/100mm dia) for cable laying in hard rocky area with off sets at both ends duly supported b y concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor]. | Metre | 12.00 | 182.87 | 2,194.44 |
| 17 | Laying of signaling/power/ telecommunication cables a s p e r cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply o f cables i s not included in this schedule). | Metre 11000.00 | — | 18.18 | 1,99,980 |
| 18 | Placing of one layer of country bricks of size approximately 2 2 0 m m x 1 0 0 m m x 60mm lengthwise vertically in the trench.[Country bricks of size 220mm x 100mm x 60mm (approximately) shall be supplied by the Contractor]. | Metre | 750.00 | 30.53 | 22,897.5 |
| 19 | Placing of one row of country bricks of size approximately 2 2 0 m m x 1 0 0 m m x 60mm breadth wise horizontally above the cables in 0.3m width trench.[Country bricks of size 220mm x 100mm x60 mm (approximately) shall be supplied by the Contractor]. | Metre | 2150.00 | 62.99 | 1,35,428.5 |
| 20 | Placing o f two rows of country bricks of size approximately 2 2 0 m m x 1 0 0 m m x 60mm breadth wise horizontally above thecables in 0.5mtr width trench.[Country bricks of size 220mm x 100mm x 60mm (approximately) shall be supplied by the Contractor]. | Metre | 750.00 | 116.41 | 87,307.5 |
| 21 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of c a b l e s , a n d consolidating t h e t r e n c h by ramming and levelling." | Metre | 2350.00 | 15.4 | 36,190 |
| 22 | "Refilling of cable trench 1m depth by 0.5m width throughout, with earth after laying of c a b l e s , a n d consolidating t h e t r e n c h by ramming and levelling." | Metre | 750.00 | 19.29 | 14,467.5 |
| 23 | "Digging of pit to a depth of 800mm of size 300mmX300mm, c a s t i n g o f concrete foundation o f s i z e 300mmX300mmX300mm and Placing of RCC cable markers on top of t h e foundation a n d refilling t h e p i t and consolidating i t b y r a m m i n g . T h e cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station l i m i t s throughout t h e cable route, diversions a n d a l s o a t every track/road crossing." | Numbers | 80.00 | 123.35 | 9,868 |
| 24 | " R o a d c r o s s i n g / Tr a c k C r o s s i n g through Horizontal Drilling at approximately depth of 1.5 to 2 m below t h e formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl o f cables e t c . (Note: T h e pilot used for HDD should be of sufficient size to s u i t insertion o f H D P E / D W C p i p e o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 4 0 m m d i a H D P E p i p e o r a n y other combination as directed by the site engineer) ( Supply o f HDPE pipe i s not covered in this schedule)" | Metre | 60.00 | 1,351.45 | 81,087 |
| 25 | B l o w i n g / D r a w i n g o f O F C cable/Power cable/Signalling c a b l e i n s i d e permanently solid lubricated HDPE Pipe already laid. This work includes necessary duct integrity test for solid lubricated H D P E pipe. ( This includes Transportation o f materials from nominated stores to site) | Metre | 250.00 | 23.43 | 5,857.5 |
| 26 | Supply of Main LED Signal Aspect - Green as p e r R D S O Specifications No.RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 6.00 | 10,030 | 60,180 |
| 27 | Supply of Main LED Signal Aspect - Yellow as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 6.00 | 8,850 | 53,100 |
| 28 | Supply of Main LED Signal Aspect - Red as per R D S O Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 6.00 | 9,233.5 | 55,401 |
| 29 | Manufacture and supply of Enameled Number plates a s p e r drawing No.TY/08/2008 with fixing arrangements and fixing them o n the existing Signals a s per the instructions of Railway representative at site.[Enameled number plates with fixing arrangements with b o l t s a n d n u t s s h a l l be supplied by the Contractor]. | Numbers | 8.00 | 305.25 | 2,442 |
| 30 | Supply of Colour light Signal pole 140mm dia, 4.6m/ 3.6m tall with necessary inspection as p e r s p e c i fi c a t i o n / drawing/ description enclosed in this document. a)Supply of colour l i g h t S i g n a l p o l e 4 . 6 m tall and 140 mm dia(Galvanised) | Numbers | 5.00 | 5,841 | 29,205 |
| 31 | Supply of Colour light Signal pole 140mm dia, 4.6m/ 3.6m tall with necessary inspection as p e r s p e c i fi c a t i o n / drawing/ description enclosed in this document. b)Supply of colour light Signal pole 3 .6 m tall and 140 mm dia (Galvanised) | Numbers | 3.00 | 4,737.7 | 14,213.1 |
| 32 | Supply of surface base to suit CLS Signal pole 140mm dia with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 8.00 | 6,814.5 | 54,516 |
| 33 | Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary inspection a s p e r specification/ drawing/ description e n c l o s e d i n this document. a)Supply o f ladder w ith platform (4.6m) for CLS(Galvanised) | Numbers | 5.00 | 5,698 | 28,490 |
| 34 | Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary inspection a s p e r specification/ drawing/ description e n c l o s e d i n this document. b)Supply o f ladder w ith platform (3.6m) for CLS(Galvanised) | Numbers | 3.00 | 5,494.5 | 16,483.5 |
| 35 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting socke t, w i t h necessary inspection a s per specification/ drawing/ description enclosed in this document. c)Supply of colour light Signal unit (2 aspect) | Numbers | 6.00 | 14,278 | 85,668 |
| 36 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug b o a r d s , r e l a y s , r e s is t o r s and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F 5 , w i r i n g a n d termination as per approved circuit diagram a n d painting the particulars.[Wire P V C copper, 3/0.75mm and 1 6 / 0 . 2 m m c o p p e r , P h y n o l i c synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1 9 9 5 - Ty p e F 5 , f o r fi x i n g resistors and condensers, MS flats 25mm x 6mm brass bolts a n d n u t s , p a i n t s , s o l d e r i n g materials, r e s i s t o r s , c o n d e n s e r s a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set | 4.00 | 4,945.51 | 19,782.04 |
| 37 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug b o a r d s , r e l a y s , r e s is t o r s and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F 5 , w i r i n g a n d termination as per approved circuit diagram a n d painting the particulars.[Wire P V C copper, 3/0.75mm and 1 6 / 0 . 2 m m c o p p e r , P h y n o l i c synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1 9 9 5 - Ty p e F 5 , f o r fi x i n g resistors and condensers, MS flats 25mm x 6mm brass bolts a n d n u t s , p a i n t s , s o l d e r i n g materials, r e s i s t o r s , c o n d e n s e r s a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. c)Wiring o f Signal/ Point/ L C control circuit (up to 12 relays/plug in type) | Set | 1.00 | 11,355.02 | 11,355.02 |
| 38 | Supply of relay rack to hold 168 relays, with necessary inspection, a s per specification/drawing | Numbers | 1.00 | 40,700 | 40,700 |
| 39 | Fabrication and Supply of box suitable for 4 Nos of KLCRs | Numbers | 1.00 | 15,009.6 | 15,009.6 |
| 40 | Concreting a n d e r e c t i o n o f R e l a y racks- 168/56 relay capacity using 'J' type bolts and painting of relay rack as per the instructions of Railway representative at site.(Supply of relay rack i s not covered i n this schedule).['J' type bolts and nuts with washers, nylon bushes, concreting materials, p a i n t a n d all other miscellaneous materials required for the work s h a l l b e s u p p l i e d b y the Contractor]. b)Concreting and erection o f relay rack - 56 capacity | Numbers | 2.00 | 3,015.04 | 6,030.08 |
| 41 | Fixing of plug boards, 50 way terminal blocks with 2BA terminals, and wiring of relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Suitable wire supporting tray with cover made of PVC shall be provided horizontally and vertically in the relay racks.. While running the wires on the aluminium ladder proper care shall be taken t o provide smooth materials like rubber beading in the openings on Phynolic sheets, to avoid damage to wires. The work also includes w i r i n g o f c o n t a c t s f o r data logger and terminating them i n t a g blocks, provision of relay index board.(Supply o f r e l a y s , plug boards, connectors and retaining clips i s not c o v e r e d i n this schedule). [Wire PVC 16/0.2mm copper, tag blocks, 2BA terminals, h a r d w o o d p l a n k o f size 600mmx 9 0 0 m m x2 5 m m w i t h decolum finish, MS a n g l e s o f size 25mmX25mmX6mm, relay fixing bolts and nuts, teakwood plank 25mm thick for fixing resistors a n d condensers, p h y n o l i c sheet 6mm t h i c k o f size 1200mmX1800mm with aluminium grooved channel frame f o r relay index board, paints, soldering materials, bunching thread, wire wound resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish and a l l o t h e r miscellaneous materials required f o r t h e w o r k s h a l l be supplied by the Contractor]. | Per Relay | 48.00 | 1,045.76 | 50,196.48 |
| 42 | Fixing o f additional p l u g boards, 5 0 ways terminal blocks and wiring of additional relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall be provided wherever required. Alterations to Relay particulars shall be incorporated in the relay Index board.(Supply o f r e l a y s , plug boards, connectors and retaining clips and 50 w a y terminal boards i s n o t covered i n this schedule).[Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood p l a n k 2 5 m m t h i c k for fi x i n g resistors a n d condensers, soldering materials, b u n c h i n g t h r e a d , w i r e wound resistance, condenser, w i r e supporting tray with cover of suitable size made of PVC, paint, varnish a n d a l l other miscellaneousmaterials required for the work shall be supplied by the Contractor ] | Per Relay | 4.00 | 726.5 | 2,906 |
| 43 | Supply of single Loop Analog addressable Fire Alarm system with loop capacity of connecting maximum 50 devices. The panel shall have a b u i l t i n p o w e r supply and battery charger R D S O Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 1.00 | 3,11,682.08 | 3,11,682.08 |
| 44 | Supply of Multi Sensor detector Dual Optical/ T h e r m a l a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 6.00 | 16,042.23 | 96,253.38 |
| 45 | Supply o f Addressable Single action indoor manual call point with back box (RED) as per R D S O specification No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 1.00 | 9,494.38 | 9,494.38 |
| 46 | Supply of Sounder having range of 81 dbA to 9 2 d b A a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 1.00 | 11,420.51 | 11,420.51 |
| 47 | S u p p l y o f Intelligent addressable Monitor m o d u l e a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 1.00 | 9,494.38 | 9,494.38 |
| 48 | S u p p l y o f Intelligent addressable control m o d u l e a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 1.00 | 9,494.38 | 9,494.38 |
| 49 | S u p p l y o f A u t o - d i a l e r f o r S M S alarm generation & routing in case of Fire Alarm to concerned p e r s o n s a s p e r RDSO No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 1.00 | 43,931.48 | 43,931.48 |
| 50 | S u p p l y o f 2 c o r e 1 . 5 s q . m m F R L S Copper unarmoured cable as per RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Metre | 70.00 | 296.94 | 20,785.8 |
| 51 | S u p p l y o f L H S C a b l e R D S O Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Metre | 20.00 | 2,246.07 | 44,921.4 |
| 52 | Supply of L H S control module. RDSO Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 1.00 | 1,55,660.6 | 1,55,660.6 |
| 53 | S u p p l y o f R e l a y M o d u l e a s p e r RDSO specification No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 1.00 | 9,867.99 | 9,867.99 |
| 54 | Supply of TCIP Module /Networking card for interfacing t h e F i r e A l a r m a n d Detection systems | Numbers | 1.00 | 30,881.44 | 30,881.44 |
| 55 | I n s t a l l a t i o n , t e s t i n g a n d commissioning c h a r g e s o f fi r e a l a r m s y s t e m including programming of devices and fire alarm panel | Set | 1.00 | 95,933.57 | 95,933.57 |
| 56 | Supply o f Double walled corrugated p i p e - 1 0 3 .5 m m i n n e r d i a & 1 2 0 m m o u t e r dia conforming to specification No. IS 14930(Part 2): 2001 with one coupler for every 6m of pipe as per Technical specification | Metre | 60.00 | 365.19 | 21,911.4 |
| 57 | Supply of GI pipes - 50mm dia -3.65mm thick as per Technical specification | Metre | 24.00 | 457.88 | 10,989.12 |
| 58 | Supply o f G I pipes - 100mm dia-4.5mm thick as per Technical specification | Metre | 340.00 | 1,119.16 | 3,80,514.4 |
| 59 | Supply and laying of PVC Warning Tape colour Orange, width o f 250mm (10") by printing w i t h b l a c k l e t t e r s 'Indian RailwaySignal/Telecom/OFC Cable' on both sides | Metre | 2150.00 | 46.15 | 99,222.5 |
| 60 | Supply of Electronic Cable Route Marker 3M m a k e o r similar, M o d e l : R F I D ( 1 4 2 1 ) and installation, c a b l e detection o f capacity to detect the cable upto 5 feet depth. | Numbers | 10.00 | 2,441.72 | 24,417.2 |
| 61 | Supply of HDPE Pipe 40mm (outer dia)/33 mm (inner dia) with couplers | Metre | 250.00 | 60.93 | 15,232.5 |
| 62 | S u p p l y a n d I n s t a l l a t i o n o f Wall/Rack mountable 2 4 Fi b r e management system ( F M S ) conforming t o RDSO/SPN/TC- 37/2000(rev-3 a m d t - 1 o r l a t e s t sim ila r to COMMSCOPE m a k e o r bette r, suitable for splicing and front patching 24F cable with all accessories and terminating the optical fibre cable with splicing and front patching in FMS in the Location Box. This includes Supply and Provision of 4 nos of Patch cords of required l e n g t h ( A l l o t h e r m a t e r ia ls r e q u i r e d for splicing are to be supplied by contractor ) | Numbers | 2.00 | 18,686.74 | 37,373.48 |
| 63 | S u p p l y a n d Installation o f s u r f a c e Wall mountable type 1 9 i n c h 1 2 U network Rack with front glass door with lock and rack fixing multipoint A C P o w e r t r i p & all accessories (Power extension board with one set of MCB, exhaust fan, cable manager) | Numbers | 2.00 | 6,761.51 | 13,523.02 |
| 64 | Supply of PBT terminals 25mm/ 60mm centre a n d P B T F u s e b l o c k s w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers | 550.00 | 61.44 | 33,792 |
| 65 | Supply of PBT terminals 25mm/ 60mm centre a n d P B T F u s e b l o c k s w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. | Numbers | 200.00 | 93.02 | 18,604 |
| 66 | Supply of PBT terminals 25mm/ 60mm centre a n d P B T F u s e b l o c k s w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers | 50.00 | 103.84 | 5,192 |
| 67 | Supply of apparatus cases (full/ half/ quarter size) to suit Southern Railway standard with necessary inspection a s p e r specification/ d r a w i n g / d e s c r i p t i o n e n c l o s e d i n this document a)Supply of apparatus case - Full size | Numbers | 2.00 | 18,821 | 37,642 |
| 68 | Supply of apparatus cases (full/ half/ quarter size) to suit Southern Railway standard with necessary inspection a s p e r specification/ d r a w i n g / d e s c r i p t i o n e n c l o s e d i n this document b)Supply of apparatus case - Half size | Numbers | 6.00 | 15,576 | 93,456 |
| 69 | Supply a n d installation o f teakwood glass fronted box of size 300mm x 600mm x 75mm with hooks to keep various keys with description engraved on the tags. [TW Glass fronted box of size 300mmx600mmx 75mm with built in lock, hooks, engraved tags and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 1.00 | 7,505.45 | 7,505.45 |
| 70 | Supply of ND Fuse of various capacities (Per unit=Per fuse) | Per Unit | 50.00 | 37.74 | 1,887 |
| 71 | Excavation o f pit,casting concrete foundation as per Drg.No.SG/CN/02/9 using metallic templates, for erection o f colour light signals up to 4 aspects.[Foundation bolts, cement, M sand, stone jelly of size 20/25mm dia and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 6.00 | 9,213.28 | 55,279.68 |
| 72 | " E r e c t i o n o f s u r f a c e b a s e , s i g n a l pole, mounting of colour light signal up to 4 aspects complete on Signal pole/ Off-set bracket, (for LED/ filament bulbs) with lenses, triple pole l a m p holder, filament switching u n i t s , CLS transformer, current regulators (whichever is applicable), fixing of ladder w i t h platform complete and concreting of ladder shoe, fixing o f number plates, marker board, lens guard, fi x i n g of speed l i m i t b o a r d wherever necessary, termination of tail cables, wiring of signal unit with P V C w ire 3/0.75mm copper, provision of EWS locks, and painting of one coat of red oxide and two coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall b e provided by drilling a hole i n t h e signal pole t o prevent the offset bracket from sliding down.(Supply of surface base, Offset bracket, CLS pole, C L S aspects complete, ladder with shoes and platform, Speed limit board, LED aspects, current regulators, l a m p holders, lamps, filament switching u n i t a n d CLS transformer is not covered in this schedule).['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm d i a , M sand, Signal Collar Rings, w i r e P V C 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead w o o l , paints PVC/Nylon sleeves, enameled number plates. enameled marker boards, EWS locks, a n d all other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 6.00 | 8,287.08 | 49,722.48 |
| 73 | Excavation of pit, casting concrete foundation and erection of apparatus case full size as per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another f o r t h e bac k door, fixing o f o n e hard wood s h e l f p l a n k 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, ' E ' type locks, cement, M sand, stone jelly o f size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & n u t s a n d a l l other miscellaneous materials required for thework shall be supplied by the Contractor.] | Numbers | 2.00 | 11,333.1 | 22,666.2 |
| 74 | " E x c a v a t i o n o f pit, casting concrete foundation and erection of apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' t y p e l o c k f o r t h e f r o n t d o o r and latching arrangement for the back door, and fixing of o n e hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required f o r t h e w o r k s h a l l be supplied by the Contractor]""" | Numbers | 6.00 | 8,787.04 | 52,722.24 |
| 75 | E x c a v a t i o n o f p i t , e r e c t i o n o f cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe for cable throughing, fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside a n d outside with o n e coa t of red-oxide and two coats o f aluminium paints.(Supply o f CT boxes is not covered in this schedule. Rails of different length shall be supplied by Railways. The contractor shall cut lengthy rails wherever required.)[Cement, M sand, stone jelly o f size 20/25mm, paint, varnish, G I Pipes 32mm dia with clamp nuts - 12mm thick - 2 Nos. for each pipe, fixing bolts and nuts with washers, EWS locks, paints and all other miscellaneous materials shall be supplied by the Contractor]. | Numbers | 1.00 | 4,999.16 | 4,999.16 |
| 76 | Termination o f n e w main/tail cables o n the existing terminals/ fuse blocks in apparatus c a s e s / b a t t e r y b o x e s / C T b o x e s / cable termination r a c k s a s p e r approved circuit diagram. T h e terminal particulars a r e to be r e p a i n t e d / c o r r e c t e d o n t h e d o o r s of a p p a r a t u s c a s e s / b a t t e r y b o x e s / cable termination boxes and FTOT index board as instructed by Railway representative at site. T h i s w o r k i n c l u d e s c l o s i n g t h e opening c r e a t e d f o r e n t r y o f n e w c a b l e s i n the apparatus cases with masonry brick work and sealing t h e bottom o f t h e apparatus cases/ cable termination racks with cable compound. [Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, M sand and all other required miscellaneous materials shall be supplied by the contractor]. (Per Unit = Per Terminal block) | Per Unit | 30.00 | 73.59 | 2,207.7 |
| 77 | Termination of main, tail, Signaling and power cables a n d internal wiring on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding c a b l e termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks o n the terminal board, drilling of necessary h o l e s , termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable p l a n , p a i n t i n g o f particulars o n sleeves andalso o n t h e inner s i d e o f t h e d o o r s of apparatus cases. After terminations are "over, t h e s i d e o p e n i n g s o f a p p a r a t u s case foundation shall b e closed w i t h brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e l e v e l a n d t h e bottom s u r f a c e s h a l l b e s e a l e d w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not covere d i n t h i s schedule)." a)Termination o n 2 5 /6 0 m m P B T terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit | 480.00 | 172.14 | 82,627.2 |
| 78 | Termination of main, tail, Signaling and power cables a n d internal wiring on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding c a b l e termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks o n the terminal board, drilling of necessary h o l e s , termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable p l a n , p a i n t i n g o f particulars o n sleeves andalso o n t h e inner s i d e o f t h e d o o r s of apparatus cases. After terminations are "over, t h e s i d e o p e n i n g s o f a p p a r a t u s case foundation shall b e closed w i t h brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e l e v e l a n d t h e bottom s u r f a c e s h a l l b e s e a l e d w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not covere d i n t h i s schedule)." b)Termination o n P B T f u s e b l o c k (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit | 30.00 | 209.93 | 6,297.9 |
| 79 | Termination of main, tail, Signaling and power cables and internal wiring by fixing additional terminals/ fuse blocks on the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification of c a b l e s using aluminium tags with letters punched neatly, as p e r a p p r o v e d circuit diagram and cable plan, painting of particulars o n sleeves and also o n the inner side o f the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall b e closed w i t h brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e l e v e l a n d t h e bottom s u r f a c e s h a l l b e s e a l e d w i t h sealing compound. a)Termination o f c a b l e s on 25/60mm PBT terminals (existing location) (Per Unit = Per Terminal block) | Per Unit | 50.00 | 151.09 | 7,554.5 |
| 80 | Termination of main, tail, Signaling and power cables and internal wiring by fixing additional terminals/ fuse blocks on the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification of c a b l e s using aluminium tags with letters punched neatly, as p e r a p p r o v e d circuit diagram and cable plan, painting of particulars o n sleeves and also o n the inner side o f the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall b e closed w i t h brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e l e v e l a n d t h e bottom s u r f a c e s h a l l b e s e a l e d w i t h sealing compound. b)Termination o f cables o n PBT fuse block (existing location)(Per Unit = Per Fuse block) | Per Unit | 5.00 | 188.86 | 944.3 |
| 81 | In s ta lla t io n o f L C c o n t r o l p a n e l cum illuminated diagram board at Level Crossing g a t e l o d g e a n d wiring t h e s a m e including interconnections and painting. (Supply of LC control panel cum illuminated diagram board is not included in this schedule). [Wire PVC 16/0.2mm copper, soldering materials,LEDs, r e s i s t a n c e s a n d a l l o t h e r required miscellaneous materials shall be supplied by the Contractor.]. | Numbers | 1.00 | 6,359.19 | 6,359.19 |
| 82 | Fixing a n d wiring o f Tw o N os. o f Electronic G a t e Wa r n i n g equipment f o r e a c h level crossing g a t e , o n e o n e a c h r o a d warning signal, amplifier i n t h e apparatus case with wire PVC 3/0.75mm and 16/0.2mm copper, and painting.(Electronic G a t e Warning Equipment and amplifier will be supplied by Railways).[All wiring, fixing and painting materials shall be supplied by Contractor]. | Set | 1.00 | 4,491.34 | 4,491.34 |
| 83 | Casting concrete foundation and erection and painting of boards with 'LEGEND' such as "Draw close if signal is at on" at the required places as per the Signalling plan. The work involves concreting of rail post to a size of 600mm x 600mm x 900mm and fixing the board to the rail using MS clamps, bolts and nuts. (Supply of boards is not covered in this schedule. Rails of different lengths will be supplied by Railways and the Contractor has to cut them to the required lengths) [Stone jelly of size 20/25mm dia, M sand, cement, M.S.flats, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 1.00 | 3,972.14 | 3,972.14 |
| 84 | Painting, erection a n d concreting o f Goods warning boards on rails as per the Signalling p l a n . T h e w o r k includes manufacturing of clamps a n d fi x i n g t h e b o a r d t o t h e rails, supply and fixing of scotch lite reflectors and concreting the rail post to a size of 600mm x 600mmx900mm. (Supply o f g o o d s warning boards are not covered in this schedule. Rails o f different lengths will be supplied by Railways and the Contractor has t o cut them t o t h e required lengths).[Stone jelly o f size 20/25mm d i a , M sand, cement, M.S.flats, scotch lite strips (14 Nos) for e a c h board, fi x i n g b o l t s a n d n u t s , paint and a l l other miscellaneous materials shall be supplied by the Contractor]. | Numbers | 2.00 | 5,398.39 | 10,796.78 |
| 85 | Provision of HDPE Pipe of dia 40/33 mm | Metre | 250.00 | 26.11 | 6,527.5 |
| 86 | Transportation of Signalling materials by road a s p e r t h e i n s t r u c t i o n s o f Railway representative at site. The work also includes l o a d i n g a n d u n lo a d in g o f the materials a)Transportation o f Signalling materials upto 100kms | MT-Km | 800.00 | 22.75 | 18,200 |
| 87 | Transportation o f Signalling materials more than 100km | MT-Km | 600.00 | 13.91 | 8,346 |
| Schedule total | ₹40,29,527.07 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ScopeofworkandATC_1.pdf
ATTACHMENT
GCC2022.pdf
ATTACHMENT
SOR2022BOOKLET.pdf
ATTACHMENT
GCCcorrectionslipsupload.pdf Correction slips for GCC
ATTACHMENT
PV1.pdf
ATTACHMENT
correctionslip7.pdf
ATTACHMENT
cablecutpenaltyletter3.pdf
ATTACHMENT
GCCcorrectionslipsupload.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .