| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Vendor | |
| 2 | L2₹44.3 L+₹2.1 L (5.03%)Rejected-Finance D NO 35 14 13 1 RP PETA GAVARA KANCHARAPALEM VISAKHAPATNAM 530008 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530008 | L2 | Rejected-Finance being not L1 | |
| 3 | L3₹45.3 L+₹3.1 L (7.32%)Rejected-Finance | L3 | Rejected-Finance being not L1 |
| Sl No | Description | Qty | Unit | M/S CHANDRA ENGINEERS AND CONTRACTORS L2 | EFFEMM ENGINEERING L1 | UV POWER TECH L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and applying Si-COAT 570 RTV/ equivalent Silicone High Voltage Insulator Coating solution using an Sprayer on supporting insulators and equipments bushing in 132 KV in incoming side at MRS with minimum thickness of 500 Micron to be coated on every insulator including testing and commissioning all as specified and as directed. | 2 | Per Bay | 42,000 ₹84,000 Lowest | 1,95,000 ₹3,90,000 | 45,000 ₹90,000 |
| 2.00 | Supply and applying Si-COAT 570 RTV/equivalent Silicone High Voltage Insulator Coating solution using an Sprayer on supporting insulators and equipments bushing of Power Transformers on both 132KV & 11 KV side outdoor complete with thickness of 500 Micron to be coated on every insulator including testing and commissioning all as specified and as directed.
Note for item No. 1.00 & 2.00 :-
1.Surface preparation of all insulation surfaces of the equipment to be coated shall be made free from dust, grease, oil and any other foreign material without damaging the surface. The surface of the equipment shall be made dry before application of the RTV coating.
2.All the required materials, tools & tackles, testing equipment, consumables etc. for application of HVIC coating shall be in bidders’ scope | 3 | Per Bay | 43,590 ₹1,30,770 Lowest | 2,25,000 ₹6,75,000 | 44,000 ₹1,32,000 |
| 3.00 | Supply & fixing 132KV, horizontal double break isolators "GRPS" /"CG"make or equivalent 132 KV, triple pole, 31.5 KA centre post rotating horizontal double break type isolators suitable for upright mounting with manual operated mechanism for main switch and earth switch including interlock of main and earth (i.e. mechanically gang operated) with all accessories required for normal operation of the isolator, without supporting structure and without terminal connectors with following configuration (copper design) : - a) For 800 Amps with one earth switch. b) Support insulators for the above isolators. One stack consisting of 325 KV having a creepage distance of 4495 mm and cantilever strength of 6 KN as manufactured & tested (31mm/KV) (Per No.). c) Terminal connectors for the above isolators a set of 06 Nos. Rigid type bimetallic terminal connectors suitable for single ASR Zebra conductor. | 2 | Each Set | 3,92,000 ₹7,84,000 Lowest | 4,50,000 ₹9,00,000 | 3,95,000 ₹7,90,000 |
| 4.00 | M&L for taking down safely unsv / burnt existing power conductor from the structure after disconnecting the pad clamps by removing rusted nuts & bolts and supply, installation of new Moose conductor in place of existing conductor and make it operational all as specified and as directed by Engineer-in-charge. | 100 | RM | 2,380 ₹2,38,000 | 300 ₹30,000 Lowest | 2,400 ₹2,40,000 |
| 5.00 | Supply and applying Si-COAT 570 RTV/equivalent Silicone High Voltage Insulator Coating solution using an Sprayer to the 11KV Indoor VCB panel Cable chamber (installed in 132KV MRS) testing complete all as specified and directed.
Note :- The coating to be ensured with minimum thickness of 500 micron and the overall qty per panel should be minimum 5 Kg. | 35 | Per Panel | 16,000 ₹5,60,000 | 9,800 ₹3,43,000 Lowest | 16,200 ₹5,67,000 |
| 6.00 | Supply and applying Si-COAT 570 RTV/equivalent Silicone High Voltage Insulator Coating solution using an Sprayer to the 11KV Indoor VCB panel Bus bar chamber (installed in 132KV MRS) testing complete all as specified and directed.
Note for item No. 5 & 6 : (a) Surface preparation: All insulation surfaces of the equipment to be coated shall be made free from dust, grease, oil and any other foreign material without damaging the surface. The surface of the equipment shall be made dry before application of the RTV coating.
(b) All the required materials, tools & tackles, testing equipment, consumables etc. for application of HVIC coating shall be in bidders’ scope
(c) The coating to be ensured with minimum thickness of 500 micron and the overall qty per panel should be minimum 5 Kg. | 35 | Per Panel | 17,500 ₹6,12,500 | 9,800 ₹3,43,000 Lowest | 17,600 ₹6,16,000 |
| 7.00 | M&L for taking down safely unsv / burnt existing 11KV ACSR conductor from the 4 pole RCC/iron structure (HT 11KV) not below than 15 Mtr including disconnecting the insulator, HT cable & clamps. Breaking the foundation completely and removing the RCC/PCC pole complete with structure and moving outside the dockyard premises by using crane and lifter/truck etc., all as specified and directed. | 10 | Each Job | 15,000 ₹1,50,000 | 4,000 ₹40,000 Lowest | 16,000 ₹1,60,000 |
| 8.00 | M&L for taking down safely unsv/ burnt existing 11KV ACSR conductor from the 2 pole RCC/iron structure (HT 11KV) not below than 15 Mtr including disconnecting the insulator, HT cable & clamps. Breaking the foundation completely and removing the RCC/PCC pole complete with structure and moving outside the dockyard premises by using crane and lifter/truck etc., all as specified and directed. | 10 | Each Job | 9,500 ₹95,000 | 3,000 ₹30,000 Lowest | 9,600 ₹96,000 |
| 9.00 | M&L for taking down safely unsv/ burnt existing 11KV ACSR conductor from the RCC/iron structure (HT 11KV) not below than 15 Mtr including disconnecting the insulator, HT cable & clamps. Breaking the foundation completely and removing the RCC/PCC pole complete with structure and moving outside the dockyard premises by using crane and lifter/truck etc., all as specified and directed. | 90 | Each Job | 5,500 ₹4,95,000 | 1,200 ₹1,08,000 Lowest | 5,700 ₹5,13,000 |
| 10.00 | Fixing, testing & commissioning of 1C x 630 Sqmm XLPE EHV copper cable termination (to end termination kit (OET)) outdoor type including wearing male connectors with all consumables complete as per specification.
Note:- Termination Joint shall be arranged by the department. | 6 | Each Job | 1,10,000 ₹6,60,000 Lowest | 1,25,000 ₹7,50,000 | 1,15,000 ₹6,90,000 |
Tender Value
₹47.7 L
EMD Value
₹95,400
Closing Date
25 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
REPAIR AND IMPROVEMENT OF HT DISTRIBUTION SYSTEM WITH SILICON HVIC COATING AND REMOTE CONTROL OPERATION OF VCBs AT MRS, CDS-1 AND CDS-2 AT NAVAL DOCKYARD, VISAKHAPATNAM UNDER GE (I) DM VISAKHAPATNAM
2025_MES_728214_1
8310/E8
Open Tender
Civil Works
Item Rate
180 days
Naval Dockyard Visakhapatnam
As per tender documents
8 documents required · 8 mandatory
₹500
GE (I) DM VISAKHAPATNAM
₹95,400
Yes
13 Mar 2026
28 Aug 2025
27 Sept 2025
28 Aug 2025
25 Sept 2025
11 Sept 2025
Amount
Supply and applying Si-COAT 570 RTV/ equivalent Silicone High Voltage Insulator Coating solution using an Sprayer on supporting insulators and equipments bushing in 132 KV in incoming side at MRS with minimum thickness of 500 Micron to be coated on every insulator including testing and commissioning all as specified and as directed.
Supply and applying Si-COAT 570 RTV/equivalent Silicone High Voltage Insulator Coating solution using an Sprayer on supporting insulators and equipments bushing of Power Transformers on both 132KV & 11 KV side outdoor complete with thickness of 500 Micron to be coated on every insulator including testing and commissioning all as specified and as directed. Note for item No. 1.00 & 2.00 :- 1.Surface preparation of all insulation surfaces of the equipment to be coated shall be made free from dust, grease, oil and any other foreign material without damaging the surface. The surface of the equipment shall be made dry before application of the RTV coating. 2.All the required materials, tools & tackles, testing equipment, consumables etc. for application of HVIC coating shall be in bidders’ scope
Supply & fixing 132KV, horizontal double break isolators "GRPS" /"CG"make or equivalent 132 KV, triple pole, 31.5 KA centre post rotating horizontal double break type isolators suitable for upright mounting with manual operated mechanism for main switch and earth switch including interlock of main and earth (i.e. mechanically gang operated) with all accessories required for normal operation of the isolator, without supporting structure and without terminal connectors with following configuration (copper design) : - a) For 800 Amps with one earth switch. b) Support insulators for the above isolators. One stack consisting of 325 KV having a creepage distance of 4495 mm and cantilever strength of 6 KN as manufactured & tested (31mm/KV) (Per No.). c) Terminal connectors for the above isolators a set of 06 Nos. Rigid type bimetallic terminal connectors suitable for single ASR Zebra conductor.
M&L for taking down safely unsv / burnt existing power conductor from the structure after disconnecting the pad clamps by removing rusted nuts & bolts and supply, installation of new Moose conductor in place of existing conductor and make it operational all as specified and as directed by Engineer-in-charge.
Supply and applying Si-COAT 570 RTV/equivalent Silicone High Voltage Insulator Coating solution using an Sprayer to the 11KV Indoor VCB panel Cable chamber (installed in 132KV MRS) testing complete all as specified and directed. Note :- The coating to be ensured with minimum thickness of 500 micron and the overall qty per panel should be minimum 5 Kg.
Supply and applying Si-COAT 570 RTV/equivalent Silicone High Voltage Insulator Coating solution using an Sprayer to the 11KV Indoor VCB panel Bus bar chamber (installed in 132KV MRS) testing complete all as specified and directed. Note for item No. 5 & 6 : (a) Surface preparation: All insulation surfaces of the equipment to be coated shall be made free from dust, grease, oil and any other foreign material without damaging the surface. The surface of the equipment shall be made dry before application of the RTV coating. (b) All the required materials, tools & tackles, testing equipment, consumables etc. for application of HVIC coating shall be in bidders’ scope (c) The coating to be ensured with minimum thickness of 500 micron and the overall qty per panel should be minimum 5 Kg.
M&L for taking down safely unsv / burnt existing 11KV ACSR conductor from the 4 pole RCC/iron structure (HT 11KV) not below than 15 Mtr including disconnecting the insulator, HT cable & clamps. Breaking the foundation completely and removing the RCC/PCC pole complete with structure and moving outside the dockyard premises by using crane and lifter/truck etc., all as specified and directed.
M&L for taking down safely unsv/ burnt existing 11KV ACSR conductor from the 2 pole RCC/iron structure (HT 11KV) not below than 15 Mtr including disconnecting the insulator, HT cable & clamps. Breaking the foundation completely and removing the RCC/PCC pole complete with structure and moving outside the dockyard premises by using crane and lifter/truck etc., all as specified and directed.
M&L for taking down safely unsv/ burnt existing 11KV ACSR conductor from the RCC/iron structure (HT 11KV) not below than 15 Mtr including disconnecting the insulator, HT cable & clamps. Breaking the foundation completely and removing the RCC/PCC pole complete with structure and moving outside the dockyard premises by using crane and lifter/truck etc., all as specified and directed.
Fixing, testing & commissioning of 1C x 630 Sqmm XLPE EHV copper cable termination (to end termination kit (OET)) outdoor type including wearing male connectors with all consumables complete as per specification. Note:- Termination Joint shall be arranged by the department.
Fixing, testing & commissioning of 1C x 630 Sqmm XLPE EHV copper cable termination (Cold/Heat Shrinkable type) Indoor type including wearing male connectors with all consumables complete as per specification. Note for item Nos. 10 & 11:- (i) Tools/Gas & accessories required for fixing of termination at GIS side shall be in bidder scope. (ii) Termination joint shall be arranged by the department. (iii) GIS technician is required during termination shall be arranged by the contractor (iv) The rate for the above shall be inclusive in the quoted rate.
M/S CHANDRA ENGINEERS AND CONTRACTORS (BID ID -3429109)
UV POWER TECH (BID ID -3429188)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .