Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC | L1 | Accepted-AOC Admitted | |
| 2 | L2₹35.1 L+₹30,287.50 (0.87%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹35.9 L+₹1.2 L (3.36%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹37.5 L+₹2.7 L (7.80%)Rejected-AOC DOOR NO 57 28 10 4 2 BHAVANI GARDENS INDUSTRIAL ESTATE POST VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹37.8 L+₹3.0 L (8.74%)Rejected-AOC D NO 28 12 17 1 SURYA BAGH VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | sri sai ram constructions L6 | koneru enterprises L11 | SREE DURGA INFOTECH L3 | MONITOR ENGINEERING WORKS L7 | M/S CHANDRA ENGINEERS AND CONTRACTORS L9 | ANJALI ENTERPRISES L13 | M/S Jayalakshmi Constructions L8 | R AND A ASSOCIATES ENGINEERS CONTRACTORS L1 | B SRINIVAS L4 | jyothi constructions L12 | RK Associates L5 | SRASHA MARINE SERVICES L2 | SVG SUPPLIES L10 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| .01SCHEDULE 'A' PART-I: E/M WORKS | ||||||||||||||||
| 1.00 | Material and labour in repairs for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in and including suitable size PVC conduit totally concealed/surface conduit in walls/ceiling with tee , bend, elbows , junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity including not less than 1.0mm thick prefabricated galvanised boxes with white modular cover plate of suitable size for fixing modular switches, sockets regulator and connected the earth wire to common earth dolly for One light/fan point/bell point/5 Amp indepentent board controlled by one switch complete incl taking down the exisitng all as specified and as directed. Note:-(i) The quoted rate shall includes all the cost of cutting, chasing, cementing work to the disturbed and making all the disturbed surfaces of wall / ceiling good to match the existing wall / ceiling along with same colour. | 235 | Point | 820 ₹1,92,700 | 756 ₹1,77,660 | 800 ₹1,88,000 | 800 ₹1,88,000 | 790 ₹1,85,650 | 899 ₹2,11,265 | 970 ₹2,27,950 | 380 ₹89,300 | 300 ₹70,500 Lowest | 845 ₹1,98,575 | 550 ₹1,29,250 | 700 ₹1,64,500 | 650 ₹1,52,750 |
| 2.00 | All as per item 1 above but for 5 Amps independant board complete all as specified and as directed | 85 | Point | 835 ₹70,975 | 698 ₹59,330 | 800 ₹68,000 | 750 ₹63,750 | 643 ₹54,655 | 816 ₹69,360 | 450 ₹38,250 | 380 ₹32,300 Lowest | 400 ₹34,000 | 756 ₹64,260 | 530 ₹45,050 | 700 ₹59,500 | 698 ₹59,330 |
| 3.00 | Material and labour in repairs for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in exisiting PVC conduit (any size) totally concealed/surface conduit in walls/ceiling with tee , bend, elbows , junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity including not less than 1.0mm thick prefabricated galvanised boxes with white modular cover plate of suitable size for fixing modular switches, sockets regulator and connected the earth wire to common earth dolly for One light/fan point/bell point/5 Amp indepentent board controlled by one switch complete all as specified and as directed. Note:-(i) The quoted rate shall includes dragging the old wires and providing the new copper wiring through exisitng conduits and making all the disturbed surfaces of wall / ceiling good to match the existing wall / ceiling along with same colour. | 110 | Point | 780 ₹85,800 | 1,042 ₹1,14,620 | 850 ₹93,500 | 800 ₹88,000 | 1,023 ₹1,12,530 | 1,233 ₹1,35,630 | 930 ₹1,02,300 | 380 ₹41,800 Lowest | 450 ₹49,500 | 1,123 ₹1,23,530 | 550 ₹60,500 | 800 ₹88,000 | 750 ₹82,500 |
| 4.00 | Description all as per item No. 3 above but for 05Amp switch socket out let,on independent board complete all as specified | 65 | Point | 810 ₹52,650 | 476 ₹30,940 | 850 ₹55,250 | 300 ₹19,500 | 512 ₹33,280 | 578 ₹37,570 | 376 ₹24,440 | 500 ₹32,500 | 800 ₹52,000 | 566 ₹36,790 | 220 ₹14,300 Lowest | 800 ₹52,000 | 576 ₹37,440 |
| 5.00 | S & F in repairs Modular switch 1 way 6A, 1 module single pole complete all as specified and directed by Engr-in-charge. (Make ABB or eqv) | 200 | Each | 31 ₹6,200 | 112 ₹22,400 | 30 ₹6,000 | 105 ₹21,000 | 170 ₹34,000 | 95 ₹19,000 | 98 ₹19,600 | 300 ₹60,000 | 100 ₹20,000 | 98 ₹19,600 | 120 ₹24,000 | 25 ₹5,000 Lowest | 102 ₹20,400 |
| 6.00 | S & F in repairs Modular switch 1 way 16A, 1 module single pole complete all as specified and directed by Engr-in-charge.(Make ABB or eqv) | 60 | Each | 88 ₹5,280 | 122 ₹7,320 | 60 ₹3,600 Lowest | 102 ₹6,120 | 130 ₹7,800 | 120 ₹7,200 | 119 ₹7,140 | 400 ₹24,000 | 250 ₹15,000 | 178 ₹10,680 | 100 ₹6,000 | 80 ₹4,800 | 152 ₹9,120 |
| 7.00 | S & F in repairs ceiling rose surface bake lite with 3 terminals complete all as specified and directed by Engr-in-charge. | 155 | Each | 40 ₹6,200 | 75 ₹11,625 | 35 ₹5,425 Lowest | 60 ₹9,300 | 92 ₹14,260 | 88 ₹13,640 | 55 ₹8,525 | 36 ₹5,580 | 150 ₹23,250 | 147 ₹22,785 | 50 ₹7,750 | 40 ₹6,200 | 95 ₹14,725 |
| 8.00 | S & F in repairs of modular Socket, 6A - 2/3 pin combined 2 module, 230 volt, multipurpose, complete all as specified.(Make ABB or eqv) | 100 | Each | 73 ₹7,300 | 98 ₹9,800 | 80 ₹8,000 | 120 ₹12,000 | 109 ₹10,900 | 121 ₹12,100 | 78 ₹7,800 | 280 ₹28,000 | 300 ₹30,000 | 76 ₹7,600 | 115 ₹11,500 | 60 ₹6,000 Lowest | 120 ₹12,000 |
| 9.00 | S & F in repairs of modular Socket 15A/16A - 2/3 pin combined 2 module, 230 volt, multipurpose, complete all as specified. (Make ABB or eqv) | 85 | Each | 144 ₹12,240 | 109 ₹9,265 | 110 ₹9,350 | 180 ₹15,300 | 132 ₹11,220 | 154 ₹13,090 | 80 ₹6,800 Lowest | 350 ₹29,750 | 400 ₹34,000 | 163 ₹13,855 | 165 ₹14,025 | 110 ₹9,350 | 229 ₹19,465 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
26 Sept 2025, 6:00 pmClosed
Garrison Engineer Naval Depot
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
REPAIR MAINTENANCE OF INTERNAL WIRING FITTINGS AND FIXTURES DBs SUBMAIN WIRING AND ASSOCIATED WORK AT MEGHADHRIPETA ASHOKA PARK PALLAVA PARK AND NAUSHAKTHI VIHAR AND ADJOINING AREA UNDER AGE EM AT GE ND VISAKHAPATNAM
2025_MES_729396_1
8528/GEND/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ND VISAKHAPATNAM
₹80,000
Yes
7 Jan 2026
4 Sept 2025
29 Sept 2025
4 Sept 2025
26 Sept 2025
19 Sept 2025
Amount
SCHEDULE 'A' PART-I: E/M WORKS
Material and labour in repairs for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in and including suitable size PVC conduit totally concealed/surface conduit in walls/ceiling with tee , bend, elbows , junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity including not less than 1.0mm thick prefabricated galvanised boxes with white modular cover plate of suitable size for fixing modular switches, sockets regulator and connected the earth wire to common earth dolly for One light/fan point/bell point/5 Amp indepentent board controlled by one switch complete incl taking down the exisitng all as specified and as directed. Note:-(i) The quoted rate shall includes all the cost of cutting, chasing, cementing work to the disturbed and making all the disturbed surfaces of wall / ceiling good to match the existing wall / ceiling along with same colour.
All as per item 1 above but for 5 Amps independant board complete all as specified and as directed
Material and labour in repairs for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in exisiting PVC conduit (any size) totally concealed/surface conduit in walls/ceiling with tee , bend, elbows , junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity including not less than 1.0mm thick prefabricated galvanised boxes with white modular cover plate of suitable size for fixing modular switches, sockets regulator and connected the earth wire to common earth dolly for One light/fan point/bell point/5 Amp indepentent board controlled by one switch complete all as specified and as directed. Note:-(i) The quoted rate shall includes dragging the old wires and providing the new copper wiring through exisitng conduits and making all the disturbed surfaces of wall / ceiling good to match the existing wall / ceiling along with same colour.
Description all as per item No. 3 above but for 05Amp switch socket out let,on independent board complete all as specified
S & F in repairs Modular switch 1 way 6A, 1 module single pole complete all as specified and directed by Engr-in-charge. (Make ABB or eqv)
S & F in repairs Modular switch 1 way 16A, 1 module single pole complete all as specified and directed by Engr-in-charge.(Make ABB or eqv)
S & F in repairs ceiling rose surface bake lite with 3 terminals complete all as specified and directed by Engr-in-charge.
S & F in repairs of modular Socket, 6A - 2/3 pin combined 2 module, 230 volt, multipurpose, complete all as specified.(Make ABB or eqv)
S & F in repairs of modular Socket 15A/16A - 2/3 pin combined 2 module, 230 volt, multipurpose, complete all as specified. (Make ABB or eqv)
S & F in repairs of modular Fan step regulator, 100W - 1 module complete all as specified.
S & F in repairs of modular Fan step regulator, 100W - 2 module complete all as specified.
S& F for modular modular white cover plate with frame 4 module complete all as specified and directed.
S& F for modular modular white cover plate with frame upto 4 to 8 module complete all as specified and directed.
S& F for modular modular metal/pvc flush box 4 module complete all as specified and directed
S& F for modular modular metal/pvc flush box upto 4 to 8 module complete all as specified and directed
Supply and fix switch piano flush type,5 Amps 240 volts single pole one way.
S/F in repairs socket only 5 amps flush type.
S/F in repairs socket only 15 amps flush type.
S/F in repairs switch socket combination 2 in 1, 5 amps flush type.
S/F in repairs switch socket combination 15/16 amps, 5 in 1, flush type.
S/F in repairs switch socket combination 2 in 1, 5 amps box type.
S/F in repairs switch socket combination 15/16 amps, 5 in 1, box type.
S&F in repairs fan regulator electronic type, rotary step type , 240 Volt.
S&F in repair Bell push flush type, 5 Amps complete all as specified and directed
S&F in repair buzzer Ding dong, AC 230 volts single pole
S & F in repairs Light Batten Frame wall mounted with all accessories suitable for mounting 18W LED including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Tube Light Batten Frame wall mounted with all accessories suitable for mounting 9/10W LED including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repairs post top lantern LED type 25/36 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed
S & F in repairs Square surface mounted LED light (2'x2') of minimum (36 Watt) warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs High bay LED flood light fittings of 100 Watts cap with pressure die cast aluminium housing IP-65 protection heat resistance toughen glass cover, electronic driver all accessories internally prewired connecting with flexible copper conductor of size 1.5sqmm including taking down existing light fittings of any description all as specified and directed.
S & F in repairs Building Security light LED type of minimum 35Watts Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 40mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair Aviation obstruction light LED type filament-less bulb complete including standard fixing arrangements including timer switch complete all as specified and as directed.
S & F in repairs Light Batten Frame wall mounted with all accessories suitable for mounting 20Watts LED including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs LED bulb 7/9 watts with holder pin/thread type complete all as specified and as directed by the Engineer-in-Charge.
S & F MCCB Enclosure Box suitable for 63 to 250 Amps outdoor type, IP 65 rating including all accessories for connecting MCCB and Cables complete all as specified by Engr-in-Charge.
S & F in repairs MCCB 4 Pole, 63 Amps, 50 Hz, 16KA, 415 Volts with all necessary aluminium lugs and glands, etc complete all as directed
S & F in repairs MCCB 4 Pole, 100 Amps, 50 Hz, 16KA, 415 Volts with all necessary aluminium lugs and glands, etc complete all as directed
S & F in repairs MCCB 4 Pole, 125 Amps, 50 Hz, 25KA, 415 Volts,adjustable thermal and fixed magnetic type with all necessary aluminium lugs and glands, etc complete all as directed
S & F in repairs MCCB 4 Pole, 160 Amps, 50 Hz, 25KA, 415 Volts, adjustable thermal and fixed magnetic typewith all necessary aluminium lugs and glands, etc complete all as directed
S & F in repairs MCCB 4 Pole, 200/250 Amps, 50 Hz, 36KA, 415 Volts, adjustable thermal and fixed magnetic typewith all necessary aluminium lugs and glands, etc complete all as directed
S & F in repairs MCCB 4 Pole, 400 Amps, 50 Hz, 36KA, 415 Volts, adjustable thermal and fixed magnetic typewith all necessary aluminium lugs and glands, etc complete all as directed
Supply and fixing in replacement of Factory made sheet metal enclosure for VTPN MCCB DBs double door (Fixed flush to the wall), with provision of MCCB as incommer & outgoing as TPN 415 volt, 8 Way, with suitable rated bus bar suitable for having MCB’s , complete all as specified (Note : MCCB/MCBs will be measured and paid separately under relavent items )
Supply and fixing in replacement of Factory made sheet metal enclosure for VTPN MCCB DBs double door (Fixed flush to the wall), with provision of MCCB as incommer & outgoing as TPN 415 volt, 4 Way, Isuitable rated bus bar and suitable for having MCB’s , complete all as specified. (Note : MCCB/MCBs will be measured and paid separately under relavent items )
Supply and fixing in replacement of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), TPN, 415 volt, 4 Way, suitable rated bus bar and suitable for having MCB’s , complete all as specified. (Note : MCBs will be measured and paid separately under relavent items )
Supply and fixing in repair of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt, 8 Way, suitable rated bus bar and suitable for having MCB’s , complete all as specified. (Note : MCBs will be measured and paid separately under relavent items )
Supply and fixing in repair of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt, 4 Way, suitable rated bus bar and suitable for having MCB’s , complete all as specified. (Note : MCBs will be measured and paid separately under relavent items )
Supply and fixing of MCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, complete all as specified
Supply and fixing of MCB 40-100 Amp, 415 Volt, TPN, breaking capacity 10 KA 'C' series, , complete all as specified
Supply and fixing of MCB 6 to 32Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, , complete all as specified
Supply and fixing of MCB 63 Amp, 415 Volt, TP, breaking capacity 10 KA 'C' series, , complete all as specified
M&L for sub main wiring with four run of 10.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 10.0 Sq mm drawn through PVC concealed/surface conduict of 40 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 05 run along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
M&L for sub main wiring with two run of 10.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 10.0 Sq mm drawn through PVC concealed/surface conduict of 40 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 03 run along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
M&L for sub main wiring with two run of 6.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 6.0Sq mm drawn through PVC concealed/surface conduict of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
M&L for sub main wiring with two run of 4.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 4.0 Sq mm drawn through PVC concealed/surface conduict of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
M&L for sub main wiring with two run of 2.5 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 2.5 Sq mm drawn through PVC concealed/surface conduict of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
Supply lay and testing of cable in trenches/walls/floor XLPE insulated, armoured electric cable (heavy duty 1100volt grade with stranded aluminium conductor of size 10sqmm 4.0 core complete all as specified and directed by Engr-in-charge.
Excavation in trenches not exc.1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for laying of cable complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified
Removing excavated surplus soils meterial not exc.50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Material and labour for natural river sand as cushioning of cables, including spreading and punning down complete all as specified and directed by Engineer in charge. Note : punned thickness shall be measured for payment purpose
Supply and laying in trenches Bricks common burnt clay building bricks, sub-class ‘B’ designation 75 laid perpendiculat to the trench for cable protection complete all as specified and as directed
Material and labour for 50 mm dia GI steel tubes 'light grade' for cable protection including sealing both ends complete all as specified and as directed by Engineer-in-charge.
Material and labour for cutting existing road/PCC/drain for laying of underground cable and including necessary earth work and making good to match with the exisitng surface with PCC1:3:6 type CI using 20mm graded aggregates complete all as specified and as directed.
S & F in repairs moduler sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB, SP, 20 Amps, 240 volts, 10 KA complete suitable for AC all as specified and directed.
Supply and laying of synthetic insulation rubber mat of size 1MX2MX2mm thickness of voltage upto 3.3KV power supply, insulation category of class A for indoor LT panel for electric shock safety complete all as specified
Labour only for cleaning , tightening nuts &screw and all associated works for DB & LT panel complete
Labour only for refixing disoriented pvc surface wiring , light fitting and all associated works complete. Note: Dilapidated conduit / casing cappingshall be measured and paid seperately of this schedule
Supply only pvc conduit upto 25 mm.
Supply only pvc casing capping 25 mm.
Supply and replacement of LED driver suitable for LED Light fittings of upto 36-75 watt LED light of any type complete all as specified
Taking down existing electric geysers of any type and capacity for inspection and checking serviceability in-situ or at workshop ,washing the inner tank with anti corrosion solution , the inlet & outlet valves, safety valve, dead weight and refixing the geysers in position and testing for proper functioning including soldering/welding where required to stop the leakage and other jobs connected with plumber and mason , reassembling the geyser set and refixing the same in original position including checking for proper function complete all as directed by Engr-in-Charge. [Note: a) The cost of transportation is included in quoted rate b)Spare parts shall be measured and paid seperatrly as supply only item of this schedule]
Supply only pressure release valve 15mm dia suitabel for existing geyser complete.
Supply only geyser element 1.5 KW / 2.0 KW capacity complete all as specified and directed by Engr-in-Charge.
S & F in repairs gun metal check valve / non return valve 15 mm dia suitable for Geyser of any make/capacity complete. All as specified and directed by Enge in charge.
S & F in repairs Thermostat of necessary capacity (1.5/2 KW) complete all as specified and directed by Engr-in-Charge.
Supply only inner tank of geyser capacity 25 ltr made out of copper suitable for existing Geyser of any type and make to match the existing size and shape of inner tank of Geyser installed at site. All as specified and directed by Enge in charge.
Supply only metal clad plug top 20A (enclosure type) suitable to fix in sheet and metal enclouser for geyser. All as specified and directed by Enge in charge.
Supply only hot / cold water stainless steel pipe connection of 15mm bore heavy duty, length upto 45cm with brass nut joints and washers at both ends complete. All as specified and directed by Enge in charge.
S&F wall mounted type Bus Bar Terminal Box, 3 Phase and Neutral [TPN], 415 Volts, cap 250-650 Amps Capacity with cable gland and of specification as specified below [a] Conductor Material - Aluminium[b] Bus Duct Construction - Sandwich Type [c] Bus Duct Rating - upto 400 Amps [d] Rated Operation Voltage [UE] - 415 / 690 Volts and maximum up to 1000 Volts. [e] Rated Insulation Voltage [UE] - 1100 Volts [f] Degree of Protection - IP54 / IP 55 for Indoor complete all a s specified and as directed
Supply and fixing in repairs to S-Line sandwich construction bus bar trunking system with Al bus bars 400 amps 50 KA breaking capacity with multilayer class 'F' insulation, 415 V , three phase 4 wire with 100% Neutral without internal earth, apoxy painted 1.5mm GI housing, uniblock joints between sections, fixed to walls/ coloumns/ roofs etc with necessasry clamps , breackets , adjustbale handing rods etc complte all as specifeid and as directed (make : C&S, L&T, Legrand, ABB)
M&L in repairs to Plug-in Box for tapping of 3 Phase supply in each floor and equipped with MCCB, 63 Amps, TPN, 25 KA with front rotatory handle configuration 3P4W with 100% Neutral suitable to match the exisiting slots of S-Line Sandwich costruction Bus Bar trunking system with multilayer Class -F insulation , 415 Volts complete all as specified and as directed.
M & L for Painting of complete LT Panels type metering console with distr system of any size and make with existing colour with 2 coats of synthetic enamel spray painting after cleaning of surface by scrubbing all dust particles/ grease/ oil etc and writing with Red colour GE (ND) (V) complete all as specified and as directed.
Supply and replacement of LED driver suitable for LED Light fittings of upto 75-100 watt LED light of any type complete all as specified
Supply and replacement of LED driver suitable for LED Light fittings of upto 100-150 watt LED light of any type complete all as specified
M&L for 25x4mm galvanised iron strip for earthing connection to building, complete all as specified.
Dismantling earthpit chamber manually without disturbing the earth continutiy strp/wire, funnel, water pipe carefully and placing with new PCC earth pit chamber made of PCC 1:3:6 type C1 chamber (450mm 450mmx 300mm depth)& ,CI frame with CI 10mm thick cover alongwith new wire mesh water funnel complete all as specified and as directed
M&L for 4mm galvanised iron earth wire for earthing connection to building, complete all as specified.
M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with GI earth strip of 25X4 mm by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber,CI frame with CI 10mm thick cover, 20mm dia GI medium grade pipe for watering , and water funnel with wirw mesh, 40mm dia light grade GI pipe for protection of strip complete all as specified and testing on completion.
M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with GI earth wire of 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber,CI frame with CI 10mm thick cover, 20mm dia GI medium grade pipe for watering , and water funnel with wirw mesh, 20mm dia light grade GI pipe for protection of strip complete all as specified and testing on completion.
Note (a) The rate quoted by the tenderer for item Ser No.01 to 89 above shall deemed to be inclusive for the following provisions in addition to the other conditions specified in the tender documents. No claim whatsoever shall be entertained at a later date on this account:- (i) Though the time period for completion of contract will be as specified in CA/work order, yet due to exigency of electrical related items emergency/priority works must be completed (within 24 Hours) on getting information through SMS/E-mail regarding the nature of repair to be carried out he shall immediately respond the same and make all out efforts to carry out the same on priority within 24 hours. In case of any delay in responding/ attending the repairs within 48 hours, the GE may at his absolute discretion impose penalty on the contractor at Rs 100/- per day per each work upto 05 (Five) days and Rs 200/- per day there after till completion of the work. Incase of delay without valid reasons as decided by GE.
(ii) Further, the above penalty is applicable even for the multiple works at multiple locations of work at the same period. It is responsiblity of contractor to make suitable arrangement for attending the repairs simultaneously at all the places. (iii) The decision of the GE as to weather of particular repair has been attended or not on a particular day will be final and binding. The above penality shall be in addition to the provisions made in clause 50 of IAFW-2249 i.e. (Compensation for delay in completion of work). Note (b) :- Tenderers/ Bidders are advised to visit the site and quote the rate accordingly.
SRASHA MARINE SERVICES (BID ID -3431017)
SREE DURGA INFOTECH (BID ID -3436234)
B SRINIVAS (BID ID -3436104)
RK Associates (BID ID -3430053)
sri sai ram constructions (BID ID -3431477)
MONITOR ENGINEERING WORKS (BID ID -3436256)
M/S Jayalakshmi Constructions (BID ID -3436490)
M/S CHANDRA ENGINEERS AND CONTRACTORS (BID ID -3436394)
SVG SUPPLIES (BID ID -3436068)
koneru enterprises (BID ID -3435849)
jyothi constructions (BID ID -3436477)
ANJALI ENTERPRISES (BID ID -3436470)
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .