| 1 | L1₹2.0 CrAdmitted-Finance 1ST FLOOR SAI COMPLEX BESIDES ADITYA VIP ENCLAVE NEAR GANESH MANDAP CHHAK JHARPADA BHUBANEWAR 751006 | KHORDHA | ODISHA | 751006 | +0.00% | ₹2.0 Cr | L1 | Admitted-Finance |
| 2 | L1₹2.0 CrAdmitted-Finance AT MARKET LANE PO PS DIST KHORDHA | KHORDHA | ODISHA | 751001 | +0.00% | ₹2.0 Cr | L1 | Admitted-Finance |
| 3 | L1₹2.0 CrAdmitted-Finance AT BADAGADA BRIT COLONY PO BADAGADA PS BADAGADA DIST PURI PIN 751018 | KHORDHA | ODISHA | 751018 | +0.00% | ₹2.0 Cr | L1 | Admitted-Finance |
| 4 | Rejected-Technical AT BDA COLONY LAXMISAGAR STAGE II BHUBANESWAR | - | - | - | Rejected-Technical Not fulfilled the criteria as per DTCN Clause No.11 (a) |
Tender Value
₹2.0 Cr
EMD Value
₹2.0 L
Closing Date
17 Mar 2026, 5:00 pmClosed
S.E. Electrical Circle (RandB) Bhubaneswar
S.E. Electrical Circle (RandB) Bhubaneswar, Nirman Soudha, Unit-V, 751001.
Shifting of line and S/S from Chandrabhaga junction towards Chandrabhaga beach cafe due to development of Puri-Konark beach front under electrical section , Konark Puri.
2026_EICCL_126640_2
Bid Identification No.S.E.E.C (RandB) 31/2025-26
National Competitive Bid
Electrical Works
180 days
Puri
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹2.0 L
16 Apr 2026
27 Feb 2026
18 Mar 2026
27 Feb 2026
17 Mar 2026
27 Feb 2026
27 Feb 2026 - 6 Mar 2026
33KV DP WPB (GI) Pole 160x152 (13Mtr. Long, 30.44KG/Mtr.)
Top Channel 100X50X6mm, 9.56 KG/Mtr., each channel length 3 mtr., 2 no's channel required =( 2x9.56x3)
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)
Insulator Support Channel for 75X40X 4.8mm., 7.14KG/Mtr., each channel length 4.3 Mtr., 1 no's channel required =( 7.14x4.3 x1)
isolator Support Channel for 75X40X 4.8mm., 7.14KG/Mtr., each channel length 4.3 Mtr., 2 no's channel required =( 7.14x4.3 x2)
Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 3.0 Mtr., 4 no's channel required =( 7.14x3x4)
50x50x6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 3.512 mtr., 4 nos angle required = (4.5x3.512x4)
Isolator operating Down Pipe Support Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required =( 7.14x0.8 x1)
Down Pipe Diagonal support Angle (GI) ,4.5 kg,/mtr, each angle (GI) length 0.388 mtr, 1 No angle required (GI) , ( 1*4.5*0.388)
Down Pipe base support Angle (GI) ,4.5 kg,/mtr, each angle (GI) length 0.34 mtr, 1 No angle required (GI) , ( 1*4.5*0.340)
Isolator support side channel (GI) 100X50X6mm,9.56 KG/Mtr., each channel length 0.5 mtr., 2 no's channel required =( 9.56x2x0.5)
Danger Plate, 2 no's.
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)
H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)
H.T. Stay set (Complete )
H.T. Stay Insulator Type-C
7/10 SWG Stay Wire 15kg /stay
Gi Pipe Earthing 40mm. 3 Mtr. Long
50x6mm GI Flat for earthing, 2.36kg/mtr., (12.5 Mtr. For L.A, 3 Mtr for AB Switch Body, 2.5 mtr. For mesh formation and 2.5 mtr. For raising)= 20.5x2.36
GI barbed wire anticlimbing device 3 Kg. Per support, 2 no's qty. required =(2x3kg)
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)
Lightning Arrester(12KV,10KA) (Station Class,class-2)
33KV 1250 AMP Double break (Turn,& Twist centre rotating ) isolator without earth switch with PI (polymer))
33KV pin insulator polymer
H W fitting(B&S) 90KN, 4Bolt
Disc insulator (B&S) 90 KN polymer
Wedge connector for 148 sqmm AAA conductor
Paddle clamp for wedge connector of 148 sq mm AAA conductor
GI Nut , Bolt & Washer of different sizes (13.718 Kg each DP with AB Switch)
Polycarbonate bird guard
Black Paint
Yellow Colour Paint for Background
Civil and services Fixing of complete 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard.
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.45Cu.mtr
Couping ratio 1:1.5:3 with dimension ( 500X500X450)= 0.1125 Cu mtr
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .
33kV 3C, 400sqmm UG Cable Supply of 33kV, 3Core, 400sqmm Aluminium, XLPE insulation UG Cable with spare (SC rating of cable in kA- 37.7kA and SC rating of Armour in kA-20kA)
Supply of Straight through jointing kits Heat Shrinkable type suitable for 33kV, 3Core, 400sqmm, aluminium UG Cable kits
Supply of Outdoor termination kits Heat Shrinkable type suitable for 33kV, 3Core, 400sqmm, HT UG Cable kits
Supply of indoor termination kits Heat Shrinkable type suitable for 33kV, 3Core, 400sqmm, HT UG Cable kits(Touch proof)
Supply of indoor termination kits Heat Shrinkable type suitable for 33kV, 1Core, 400sqmm, HT UG Cable kits(Touch proof)
Supply of materials for High Density Polyethelene (HDPE) pipe 200mm diameter, PE 80- PN8 for laying of 33kV UG cable
Supply of RMU 33KV 630A single BKR module
Earthing Earthing Conductor : 50X6 mm (2.4kg /mtr) flat (GI) for equipments structure etc.
Pipe Earthing 40 mm GI pipe
ERECTION Laying, Commissioning & Testing of 33kV, 3Core, 400sqmm, XLPE insulation (extruted type) UG cable with spare by open trench method.
Erection of Straight through jointing kits/Outdoor termination kits/ indoor termination Kits Heat Shrinkable type suitable for 33kV, 3Core, 400sqmm, aluminium UG Cable kits
Erection of Straight through jointing kits/Outdoor termination kits/ indoor termination Kits Heat Shrinkable type suitable for 33kV, 1Core, 400sqmm, aluminium UG Cable kits
Laying of 200mm dia PE 80-PN8, HDPE pipe inside open trench.
Erection of RMU 33 KV 630A single BKR MODULE + AUXPT
Civil work Earth work excavation of soil
Earth work excavation of hard rock
Back filling with excavated soil outside and above the trench
Damage of asphalt/tar road and other utilities and reconstructing to bring to its original shape after laying of cable in open trench (1mtr. width)
Prefabricated RCC foundation of 33kV RMU
SITC of GI Fencing with Gate around each RMU
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .
Supply and erection of GI Pipe of dia. 150mm, Class-B (8Mtr.)
Supply and Erection of Cable Route Marker along the cable route at an interval of 30mtrs with civil works
11kV 3C, 300sqmm UG Cable Supply of 11kV, 3Core, 300sqmm Aluminium, XLPE insulation UG Cable with spare (SC rating of cable in kA- 28.3kA and SC rating of Armour in kA-15kA)
Supply of Straight through jointing kits Heat Shrinkable type suitable for 11kV, 3Core, 300sqmm, aluminium UG Cable kits
Supply of indoor termination kits Heat Shrinkable type suitable for 11kV, 3Core, 300sqmm, HT UG Cable kits(Touch proof)
Supply of outdoor termination kits Heat Shrinkable type suitable for 11kV, 3Core, 300sqmm, HT UG Cable kits(Touch proof)
Supply of materials for High Density Polyethelene (HDPE) pipe 160mm diameter, PE 80- PN8 for laying of 11kV UG cable
Supply of RMU 11KV 3 way 630 A (LLV(2iso+1 BKR +AUXPT) ))
Earthing Earthing Conductor : 50X6 mm (2.4kg /mtr) flat (GI) for equipments structure etc.
Pipe Earthing 40 mm GI pipe
ERECTION Laying, Commissioning & Testing of 11kV, 3Core, 300sqmm, XLPE insulation (extruted type) UG cable with spare by open trench method.
Erection of Straight through jointing kits/Outdoor termination kits/ indoor termination Kits Heat Shrinkable type suitable for 11kV, 3Core, 300sqmm, aluminium UG Cable kits
Laying of 200mm dia PE 80-PN8, HDPE pipe inside open trench.
Erection of RMU 11KV 3 way 630 A (LLV(2iso+1 BKR +AUXPT) ))
Civil works Earth work excavation of soil
Earth work excavation of hard rock
Back filling with excavated soil outside and above the trench
Prefabricated RCC foundation of 11kV RMU
SITC of GI Fencing with Gate around each RMU
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .
Supply and erection of GI Pipe of dia. 150mm, Class-B (8Mtr.)
Supply and Erection of Cable Route Marker along the cable route at an interval of 30mtrs with civil works
11kV 3C, 95sqmm UG Cable Supply of 11kV, 3Core, 95sqmm Aluminium, XLPE insulation UG Cable with spare (SC rating of cable in kA- 9kA and SC rating of Armour in kA-9kA)
Supply of indoor termination kits Heat Shrinkable type suitable for 11kV, 3Core, 95sqmm, HT UG Cable kits(Touch proof)
Supply of outdoor termination kits Heat Shrinkable type suitable for 11kV, 3Core, 95sqmm, HT UG Cable kits(Touch proof)
Supply of materials for High Density Polyethelene (HDPE) pipe 160mm diameter, PE 80- PN8 for laying of 11kV UG cable
ERECTION Laying, Commissioning & Testing of 11kV, 3Core, 95sqmm, XLPE insulation (extruted type) UG cable with spare by open trench method.
Erection of Straight through jointing kits/Outdoor termination kits/ indoor termination Kits Heat Shrinkable type suitable for 11kV, 3Core, 95sqmm, aluminium UG Cable kits
Laying of 160mm dia PE 80-PN8, HDPE pipe inside open trench.
Civil work Earth work excavation of soil
Earth work excavation of hard rock
Back filling with excavated soil outside and above the trench
Supply and erection of GI Pipe of dia. 150mm, Class-B (8Mtr.)
Supply and Erection of Cable Route Marker along the cable route at an interval of 30mtrs with civil works
11kv DP WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)
Top Channel 100X50X6mm, 9.56 KG/Mtr., each channel length 3 mtr., 2 no's channel required =( 2x9.56x3)
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)
AB switch Mounting Channel 75X40X4.8mm, 7.14KG/Mtr, each channel length 3 Mtr., 2 no's channel required =( 7.14x3x2)
AB Switch Side Support Channel 100X50X6mm,9.56 KG/Mtr., each channel length 0.35 mtr., 2 no's channel required =( 9.56x2x0.35)
Channel Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required =( 7.14x0.8x1)
Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 3.0 Mtr., 4 no's channel required =( 7.14x3x4)
50x50x6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 3.512 mtr., 4 nos angle required = (4.5x3.512x4)
Danger Plate, 2 no's.
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)
H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)
H.T. Stay set (Complete )
H.T. Stay Insulator Type-C
7/10 SWG Stay Wire 15kg /stay
Gi Pipe Earthing 40mm. 3 Mtr. Long
50x6mm GI Flat for earthing, 2.36kg/mtr., (12.5 Mtr. For L.A, 3 Mtr for AB Switch Body, 2.5 mtr. For mesh formation and 2.5 mtr. For raising)= 20.5x2.36
GI barbed wire anticlimbing device 3 Kg. Per support, 2 no's qty. required =(2x3kg)
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)
Lightning Arrester(12KV,10KA) (Station Class,class-2)
AB Switch (11KV,400A.3pole,50Hz)
11 KV pin insulator polymer
H W fitting(B&S) 70KN, 3Bolt
Disc insulator (B&S) 70 KN polymer
Wedge connector for 100 sqmm AAA conductor
Polycarbonate bird guard
GI Nut , Bolt & Washer of different sizes (13.718 Kg each DP with AB Switch)
Black Paint
Yellow Colour Paint for Background
Civil and services Fixing of complete 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard.
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.45Cu.mtr
Couping ratio 1:1.5:3 with dimension ( 500X500X450)= 0.1125 Cu mtr
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .
Installation , Tesitng & Comissioning of 11KV auto reclosure unit on existing structure as per TPCODL specification including loasing unloasing shifting / transporation form site / tant
1.1 kv LT 4C X95 sqmm XLPE U/G cable Supply of 1.1 KV 4C X95 sqmm XLPE insulation armoured - almunium U/G cable open trench
Supply of (HDPE) pipe 110mm diameter, PE 80- PN8
ERECTION Laying of 1.1 KV 4C X95 sqmm XLPE insulation armoured - almunium U/G cable
Laying of (HDPE) pipe 110mm diameter, PE 80- PN8
Supply and erection of double Compression Flameproof Type Glanding for armoured Cable 3.5/4C 50-95 sqmm including making hole in Base plate and dressing of cable along with vermin proofing properly supply to be done as per TOCODL sepc and approved make
Civil work Earth work excavation of soil
Earth work excavation of hard rock
Back filling with excavated soil outside and above the trench
11kv cutpoint with 180 degree angle 9 Mtr. long 300 Kg. PSC Pole
LT Stay set Complete
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 1.2 mtr., 2 no's channel required =( 2x9.56x1.2)
Danger Plate, 1 no's.
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)
GI barbed wire anticlimbing device 3 Kg. Per support
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)
Earthing of Support ( Coil Type )
GI Nut , Bolt & Washer of different sizes (3.55 Kg each Cut Pole)
Black Paint
Yellow Colour Paint for Background
CIVIL and Service Works Concreting ratio 1:1.5:3 (500mmX500mmX1500mm) = 0.375 Cu.mtr per pole
Dismantling Portion Dismentling of 11/13 mtr Joist /WPB pole 150X150MM / 160X160MM
Dismentling of 11/13 mtr Joist /WPB pole 150X150MM / 116x100 MM
Dismentling of 9/8 Mtr PCC/ Joist Pole
Dismentling of existing auto reclouser
Dismentling of ACSR /AAAC 34/ 55mm2 form overhead line
Dismentling of ACSR /AAAC 148/ 232mm2 form overhead line
Dismentling of Various size LT AB CABLE N:B:. Salvage value amounting to Rs.1,16,676.38 to br drductrd from the contractor's bill.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_583489.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.95 MB
DTCN.pdf
Tender Documents • 1.95 MB
BOQ_583489.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid