Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC | ₹21.8 L Quoted ₹23.8 L | L1 | Accepted-AOC lowest |
| 2 | L2₹24.5 L+₹72,413.50 (3.05%)Rejected-Finance 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | ₹24.5 L+₹72,413.50 (3.05%) | L2 | Rejected-Finance other than lowest |
| 3 | L3₹25.0 L+₹1.2 L (4.95%)Rejected-Finance | ₹25.0 L+₹1.2 L (4.95%) | L3 | Rejected-Finance other than lowest |
| 4 | L4₹27.0 L+₹3.2 L (13.4%)Rejected-Finance | ₹27.0 L+₹3.2 L (13.4%) | L4 | Rejected-Finance other than lowest |
| 5 | L5₹28.7 L+₹4.9 L (20.8%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | ₹28.7 L+₹4.9 L (20.8%) | L5 | Rejected-Finance other than lowest |
Tender Value
₹27.5 L
EMD Value
₹55,000
Closing Date
28 Dec 2024, 6:00 pmClosed
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Services Near jagraon bridge Ludhiana-141001 (Punjab)
Special repair to Steel tubular Poles at Baddowal and Provn of certain minor E/M works at Dholewal, Doraha and Baddowal under GE Ludhiana.
2024_MES_686166_1
GE/LDH-58/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Baddowal, Dholewal and Doraha
As per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹55,000
Yes
17 Jan 2025
29 Nov 2024
30 Dec 2024
29 Nov 2024
28 Dec 2024
14 Dec 2024
29 Nov 2024 - 13 Dec 2024
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5 m deep for laying of pipes/cables etc getting out and bottom surface to required gradient complete all as directed & specified
M&L returning, filling in including spreading leveling watering and well ramming in layers each not exceeding 25cm thickness complete all as specified and directed
M&L removal of surplus spoil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Supplying, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable for under ground cable complete all as specified & directed .(18 cm thick pinned down thickness shall be measured and paid).
M &L old size sub class 'B' bricks laid flat in trenches over the cable with length of brick perpendicular to the direction of the cable adjacent/abutting each other complete all as specified and directed.
All as per item No 5 above but old bricks shall be reused.
Supply, laying, jointing, testing and commissioning in replacement of 16 Sqmm 4 core cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade laid in trenches/on pole including taking down existing complete all as specified and directed
Supply, laying, jointing, testing and commissioning in replacement of 25 Sqmm 3.5 core cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor 1100 volts grade laid in trenches/on pole including taking down existing complete all as specified and directed
Supply and fix Steel tubular pole swaged poles type 410SP-31(9.0 metre long) Swan neck type complete with CI base plate and finial and single swan neck including with two coats of aluminium paint over a coat of primer and marking 30cm wide strips (total 5 Nos) with white and black paint alternately on external surfaces above column/PCC including numbering with black paint and painting with bituminous paint externally for portion embedded in PCC complete all as specified and directed including taking down existing and removing from site. Note : Excavation,earth work,PCC will be paid separately.
M & L for PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation for electric poles/struts, PCC blocks including necessary form work for fair finished surfaces complete all as specified and directed.
M & L for P.C.C (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in coping of poles including necessary form work for fair finished surfaces without using extra cement complete all as specified and directed.
M & L for P.C.C (1:3:6) type C-2 using 20 mm graded crushed stone aggregate as in coping including necessary form work or in any situation complete all as specified and directed.
S&F in replacement GI tubing 40 mm bore 'light grade', galvanized, with all fittings jointed and laid in trenches/fix on wall floor for cable protection complete all as specified and directed.
Supply and fixing in replacement LED street light fitting 60watt , IP 65, made up of pressure die cast aluminium housing with potted Isolated driver and high power LED and individual lenses, operating range -90V to 340V AC complete all as specified and directed.
Fixing only LED street light fitting 60 watt on pole complete all as specified and directed. (Note : Light will be taking down from old pole)
Supply and fixing in replacement security light bracket made of 40mm dia GI light grade pipe 1.5 metre long bend to shape including fixing on pole with suitable size of flat iron clamps, nut, bolt etc. complete all as specified and directed.
Fixing only bracket with security light made of 40mm bore GI light grade pipe 1.5 metre long on pole complete all as specified and directed. (Note : Bracket and security will be taking down from old pole)
S& F in replacement polycarbonate thermoplastic outdoor junction box for steet lights with flap cover operate with IEC 61439-3 which should be shock proof, protection class-II, earthed , IP 65 weather proof , corrision free , acid and chemical resistant , impact resistant, , ultra voilet resistant made of halogen & silicone free recyclable material, internally embedded gasket with provision for cable entry through integrated flanges top and bottom,The gasket should be internally embedded made of polycarbonate incl with fixing arrangement ( clamps, nuts and Bolts etc.) complete all as specified and directed.
M & L PVC copper wiring with 2 runs of 2.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 2.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit from junction box to street light etc complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technique and necessary T&P for passing of LT/HT cables complete all as specified and directed.
M& L for earthing complete with & including galvanized MS earth plate of size 600 x 600 x 6 mm thick, buried vertically in ground to a depth not less than 2.25 metre below ground level, with lop edge of earth plate not less than 1.5 below ground level connected to galvanized earth wire soldered and riveted or connected to earth plate by means of nuts, bolts , check nuts & washers, of galvanized iron or steel all as Shown in electrical plate No. 3 of MES SSR Part- I (2009) and connected to panel board, all as specified and testing on completion including provn of earth wire 4 mm dia duly protected with and including 15 mm dia bore medium grade GI pipe upto 7.5 (maximum) meter from electrode to earth point including provn of the earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate and GI light grade watering pipe of 20mm dia bore with funnel with wire mesh including all necessary excavation & earth work in any type of soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC 1:3:6 type C-1 as in earth chamber, 50 mm thick RCC cover using cement concrete 1:2:4 type B-0 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c both way with suitable handle for lifting arrangement & including form work and MS frame using MS angle of size 40mm x 40mm x 6mm complete all as specified & directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to the department.
Supply and lay XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed.
Supply and lay XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed.
Supply and fixing in replacement galvanised pipe light grade of ISI marked 50 mm bore for passing of cable fixed to poles/walls/lay under floor complete with and including fittings as required complete all as specified and directed.
S & F in replacement LED flood light fitting of 120 watt in epoxy powder coated pressure die-cast aluminium housing with, BIS marked electronic driver duly enclosed of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening of 5 KV minimum with IP-66, protection for LED and control gear compartments with high power LED chips suitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having efficacy 100 lumens/watt complete all as specified and directed.
M&L MCB SP 6 to 32 Amps, 10 KA, C-curve complete all as specified and directed.
M&L MCB SPN 32 Amps, 10 KA, C-curve complete all as specified and directed.
M&L MCB TPN 16 to 32 Amps, 10 KA, C-curve complete all as specified and directed.
M&L MCB TPN 40 to 100 Amps, 10 KA, C-curve complete all as specified and directed.
M&L switch Piano flush type single pole, one way 5 amp complete all as specified and directed.
M&L for sheet metal DB for MCBs, SPN, 4 ways,single door,singal phase, IP-43 company painted with 200 Amps rated bus bar, neutral bar/ connectors, each bar/ connectors, prewired complete with suitable copper conductor wire, PVC insulated, FRLS type with suitable copper thimbles, lugs etc complete all as specified and directed.
M&L for sheet metal DB for MCBs, SPN, 8 ways,single door,singal phase, IP-43 company painted with 200 Amps rated bus bar, neutral bar/ connectors, each bar/ connectors, prewired complete with suitable copper conductor wire, PVC insulated, FRLS type with suitable copper thimbles, lugs etc complete all as specified and directed.
M&L Sub main wiring with PVC insulated cable copper conductor FRLS two single core 4 Sqmm drawn through Existing or new PVC rigid non metallic conduit including earth continuity FRLS copper conductor 4 Sqmm PVC insulated with green insulation complete all as specified and directed. Note : PVC conduit shall be measured and paid separately.
M&L earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point complete all as specified and directed. including testing on completion as specified.
Material & labour earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth electrode GI strip 32 x 6mm connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth strip connected to test point and protected by galvanized iron light grade 50mm bore and GI pipe 20mm bore light grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC chamber in cement concrete (1:3:6) type C-2 using graded stone aggregate and cover in RCC 1:2:4, 50mm thick and all as shown in Electrical Plate No. 3 of MES Schedule (Part-I) of 2009 complete all as specified and directed. Notes : (i) Outer edge of earth pit will be 1.5m away from the outer edge of PCC chamber. (ii) Water pipe shall be provided in slanting position.
M&L for Point wiring complete with copper conductor cable FRLS 2.5 sq mm for one 3 pin socket outlet, 15 amps and including provision of 2.5 sq mm FRLS PVC insulated copper conductor cable as earth continuity conductor on independent board drawn through and including 20 mm dia PVC rigid non metalic conduit with all accessories such as internal bend end caps etc complete fixed on wall/ceiling/roof etc by means of suitable GI saddles/Spacers including provison of 2.5 sq mm single PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor, fabricated steel terninal box made out of 1.6 mm thick MS sheet concealed in wall with 3 mm thick hylem top cover sheet ISI marked with chromium plated screws and cup washers for housing the switches socket outlets, fan reguators etc all as specified and directed. Note : Unit rates quoted by contractor shall be deemed to included for cutting chases in walls and making good in cement mortar (1:3) and finishing the surface to match with exisiting surface using putty and distemper.
Supply and fix switch piano flush type, 15 amps, 230V AC, single pole, one way complete all as specified and directed.
Supply and fix socket out let 2 in 1, 3 pin, 6 pin 15 Amp flush type complete all as specified and directed.
Supply and fix bib taps cast copper alloy screwed down high pressure with butterfly handle scrwed for iron pipe both ends (brass) 15 mm size weight 500 gm complete all as specified and directed.
Supply and fix steel water tubing galvanized 15 mm bore, medium grade ISI marked fixed wall under flor on surfaces or concealed incl all pipe fitting gixing materials etc complete incl making good to all distrubed surfaces complete all as specified and directed.
Supply and fixing of Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed,15 mm size minimum weight 90 gms complete all as specified and directed.
Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated, complete with all accessories such as safety valve, thermostate,NRV, connection piece with all fixing arrangement and grouting suitable size of nuts and bolts and making good to disturbed surface complete all as specified and directed.
Supply, Install, Testing and commissioning of Solar Hot Water System Evacuated glass tube type direct transfer of heat capacity 200 LPD including electrical back up of 2.0 KW complete all as specified and directed. Note:- Any civil works required for the erection and commissioning of the system including foundation work and staging for the flat plate collectors hot/cold water storage tank etc shall be deemed to be including in the item rates.
Supply & fixing COLD WATER galvanised iron tubes of size 20 mm bore (medium grade) with all fittings and laid in trenches, under floor or road , through ceiling ,including fittings such as socket, bend, elbow, union etc. complete all as specified & directed .
M&L for HOT Water tubing galvanised iron with screwed and socket joints including all fitting such as bends,elbow, tees,short pieces, plug,union, sockets and fixing material hocks clips etc of size 15 mm dia, ISI marked, fixed along wall/roof/OR in trenches duly insulated with 50mm thick all around of pipe rock wool/mineral wool, chicken mesh and cladding with 25 SWG aluminium sheet including fixing clamps, screws etc complete all as specified and directed.
S & F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 500 lites including necessary staging with MS angle iron frame 50 x 50 x 6 mm in legs and cross bracing to place water tank ON flat plate including 2 coats of synthetic enemal paint over a coat of red oxide etc complete all as specified and directed
Supply & fixing in replacement gun metal gate valve 20 mm bore with iron wheel with necessary fittings for GI pipes with necessary fittings complete, all as specified & directed.
All as per item No 47 above but 15 mm bore complete all as specified and directed.
M&L ball Valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 20 mm complete all as specified and directed.
Material and labour for sub main wiring with two runs of single core PVC insulated copper cable multi-stranded conductor 2.5 Sqmm drawn through in and including non metalic PVC heavy duty conduit 25 mm bore with all accessories with 1.5 Sqmm PVC insulated unsheathed copper conductor as earth wire connected to common earth all as specified and directed. Note: Two turns of 2.5 sqmm copper cable and one run of 1.5 sqmm cable including one run of PVC conduit will be measured as one unit.
S&F double door Sheet metal enclosures factory made powder coated DBs IP-65/66 protection, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032, isolators etc triple pole and neutral 4 way with 200 Amp rated bus bar 415 volts powder coated painted complete all as specified and directed.
M&L framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; ramework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M &L Point wiring complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through and including 20mm dia PVC rigid non metallic conduit with all accessories such as internal bend end caps etc complete concealed in walls/ceiling/roof/etc including provision of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor and making good to all disturbed surfaces and matching the same with adjoining specifications, all as specified and as directed for the following :-
One light/fan point controlled by one, one way switch
All as per item No. 53 described here-in-before but with copper conductor cable FR LS 2.5 Sqmm for one 3 pin socket outlet, 15 Amps and including provision of 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board.
Supply and fix MCB TPN 63 Amp, 415 Volt , C- series, 50 Hz, breaking capacity-10 kA complete all as specified and directed.
Supply and fix for exhaust fan made of sturdy Engineering plastic complete with louvers shutter voltage 230V 50 HZ RPM 1200,copper winding of sweep 300mm complete all as specified and directed.
Supply and fix ceiling rose surface type bakelite 65 x 50mm with three terminals complete all as specified and directed
Supply and Fix Switch Socket combination 2 in 1 outlet 5 pin, 6/16 A flush type complete all as specified and directed.
M&L for making hole using core drill suitable for fixing exhaust fan and making good to all disturbed surfaces and matching the same with adjoining specifications complete all as specified and directed.
Supply and fix ceiling fan white colour complete with accessories 230V,1200mm sweep five star rated with brushless direct current motor(BLDC) complete all as specified and directed.
Taking down electric water heater Geyser with its accessories and keeping in safe custody for reuse at site and making good disturbed surface. Refixing the same at the location as directed and connecting up including all its accessories such as safety valve,thermostat,NRV ,supply and fixing of GI pipes of dia 20mm laying in wall making serviceable after fixing complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4.0 core complete all as specified and directed.
SUN MANN ENGINEERS (BID ID -3192981)
RAJINDER ELECTRICAL WORKS (BID ID -3195254)
JASSI TRADERS (BID ID -3200770)
UNITED ENGINEERING CORPORATION (BID ID -3195261)
HG construction (BID ID -3191500)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .