| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 CrAccepted-AOC KOTWALI BAZAR DHARAMSHALA H P 176215 | DHARAMSHALA | KANGRA | HIMACHAL PRADESH | 176215 | ₹2.9 Cr Quoted ₹3.0 Cr | L1 | Accepted-AOC L-I bidder has negotiated on the overeall quoted amount with .75 persent |
| 2 | L2₹3.9 Cr+₹90.7 L (30.7%)Rejected-Finance 25 INDUSTRIAL AREA PHASE II NAGROTA BAGWAN DISTT KANGRA H P | KANGRA | HIMACHAL PRADESH | 175013 | ₹3.9 Cr+₹90.7 L (30.7%) | L2 | Rejected-Finance Rejected due to L2 Bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical The bidder in joint venture mode has not executed the works in accordance and the Commercial experience of the JV Firm is not in accordance of the SBD, hence non responsive |
| 4 | Rejected-Technical MAIN BAZAR GHUMARWIN DISTT BILASPUR HP 174021 | BILASPUR | HIMACHAL PRADESH | 174021 | - | - | Rejected-Technical The bidder has not executed the works in accordance and the Commercial experience of the Firm is not in accordance I of the SBD and declared, hence non responsive |
Tender Value
₹2.2 Cr
EMD Value
₹2.2 L
Closing Date
23 Feb 2022, 4:00 pmClosed
Chief Engineer Operation North HPSEBL Dharamshala
Chief Engineer Operation North HPSEBL Dharamshala
Converting of LT overhead system into underground cable system from Fuwara Chownk to khada Danda Road, Khaniara Road, Sub Station Kotwali Bazar to Fuwara Chowk and Kotwali Bazar to Gas Agency Office under Electrical Sub-Division Dharamshala.
2022_HPSEB_56673_1
CEON-Dep-10/2021-22
Open Tender
Electrical Works
Turn-key
270 days
Dharamshala
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,360
₹2.2 L
Dharamshala
20 Sept 2022
11 Feb 2022
24 Feb 2022
11 Feb 2022
23 Feb 2022
12 Feb 2022
15 Feb 2022
Amount
LT Undergrounding from Fuwara Chowk to Khada Danda Road.
LT 3.5 Core XLPE cable armoured cable 240mm2 (as per technical specifications)
LT 3.5 Core XLPE cable armoured cable 185mm2 (as per technical specifications)
LT 3.5 Core XLPE cable armoured cable 95mm2 (as per technical specifications)
Main distribution box(MDB) with 250A, main MCCB and 6 NO. 63A, FP MCCB outgoing with 10NO. 32A, SP MCCB outgoing ,IP55 , CPRI Tested (as per technical specifications)
Main distribution box(MDB) copper bus-bar with ACB 630A, with 50 to 100% current setting along with 4 No. MCCB(3P) 400A, Outgoing IP55 , CPRI Tested (as per technical specifications)
LT panel with Bus Coupler (1000A ACB Incomer-2Nos with Microprocesssor ET Trip system with thermal memory and indivisual fault indicator based with Overload, Short Circuit protection system,1000MCCB Bus Coupler -1No., 630A MCCB 3-Pole 4 Nos. for Outgoing, 125A MCCB 3-Pole -4 Nos. fo connections , IP 55 CPRI Tested.)
Cable tray (Hot Dip Galvanised )Ladder type width 300mm,Height 50mm(16 SWG) (as per technical specifications)
Distribution box (DB) with , 4- Nos 3 Phase Connections , 9No. ,Single Phase outgoing(140-200A, ) suitable for termination of 70 mm sq. Cable
Distribution box (DB) with , Main Incomer 400A MCCB -1 No.,Output,63A,MCB TP-3No,40A, MCB SP-12no.
MDB pannel stand Ms Angle 50*50*6mm
LT PVC CABLE 25mm2, 2Core ,
LT PVC CABLE 50mm2,3.5 Core,
LT XLPE CABLE 70mm2,3.5 Core
Pipe HDPE size 110mm
GI Flat 25*6mm
Earthing Set (For MDB Panel)
Dismantling of Existing Overhead line along with material service wire and re-erection of service wire(1ph/3ph)
Copper thimble
Double Compression Brass Cable gland (185mm2
Nuts & Bolts off sizes ( Galvanized Type)
Civil work for Restroration of site to original conditions
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Centering and shuttering including strutting, propooing etc. and removal of form for walls (any thickness) including attached plastrs, butteresses, plinth and string courses etc.
Reinforced cement concrete work in walls (any thickness) , including attached pilasters, butteresses, fillets, columns, pillers, piers, abutments, posts and struts etc. above plonth level upto floor five level, excluding cost of centering, shuttring, finishing and reinforcemnt 1:1.5:3 (1 cement:1.5 coarse sand): 3 graded stone aggregate 20mm nominal size)
Cable Ceiling arrangement at Cable end ( LT Termination Kits)
LT Undergrounding from Kotwali Bazar to Gas Agency
LT 3.5 Core XLPE cable armoured cable 185mm2
Main distribution box(MDB) copper bus-bar with ACB 630A-1No, with 50 to 100% current setting along with 4 No. MCCB(3P) 400A, Outgoing
Cable tray (Hot Dip Galvanised )Ladder type width 300mm,Height 100mm(16 SWG)
Distribution box (DB) with , Main Incomer 400A,,MCCB,Output,63A,,MCB TP,3No.,40A,, MCB SP,12no.
MDB pannel stand Ms Angle 50*50*6mm
LT PVC CABLE 25mm2, 2Core ,
LT PVC CABLE 50mm2,3.5 Core,
LT XLPE CABLE 70mm2,3.5 Core,
Pipe HDPE size 110mm
Double Compression Brass Cable gland (Flame Proof)185mm2
Earthing Set (For MDB Panel)
Dismantling of Existing Overhead line along with material service wire and re-erection of service wire(1ph/3ph)
GI Flat 25*6mm
Copper thimble
Nuts & Bolts off sizes ( Galvanized Type)
Civil work for Restroration of site to original conditions
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Centering and shuttering including strutting, propooing etc. and removal of form for walls (any thickness) including attached plastrs, butteresses, plinth and string courses etc.
Reinforced cement concrete work in walls (any thickness) , including attached pilasters, butteresses, fillets, columns, pillers, piers, abutments, posts and struts etc. above plonth level upto floor five level, excluding cost of centering, shuttring, finishing and reinforcemnt 1:1.5:3 (1 cement:1.5 coarse sand): 3 graded stone aggregate 20mm nominal size)
Cable Ceiling arrangement at Cable end ( LT Termination Kits)
LT Undergrounding from Substation B to Fuwara Chowk
LT 3.5 Core XLPE cable armoured cable 185mm2
Main distribution box(MDB) copper bus-bar with ACB 630A, with 50 to 100% current setting along with 4 No. MCCB(3P) 400A, Outgoing
Cable tray (Hot Dip Galvanised )Ladder type width 300mm,Height 100mm(16 SWG)
Distribution box (DB) with , 4No. ,3 Phase outgoing(140-200A,) suitable for termination of 70 mm sq. Cable
Distribution box (DB) with , 4- Nos 3 Phase Connections , 9No. ,Single Phase outgoing(140-200A, ) suitable for termination of 70 mm sq. Cable
MDB pannel stand Ms Angle 50*50*6mm ,
LT PVC CABLE 25mm2, 2Core
LT PVC CABLE 50mm2,3.5 Core
LT XLPE CABLE 70mm2,3.5 Core
Pipe HDPE size 110mm
GI Flat 25*6mm
Copper thimble
Double Compression Brass Cable gland (Flame Proof)
Dismantling of Existing Overhead line along with material service wire and re-erection of service wire(1ph/3ph)
Earthing Set (For MDB Panel)
Nuts & Bolts off sizes ( Galvanized Type)
Civil work for Restroration of site to original conditions
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Centering and shuttering including strutting, propooing etc. and removal of form for walls (any thickness) including attached plastrs, butteresses, plinth and string courses etc.
Reinforced cement concrete work in walls (any thickness) , including attached pilasters, butteresses, fillets, columns, pillers, piers, abutments, posts and struts etc. above plonth level upto floor five level, excluding cost of centering, shuttring, finishing and reinforcemnt 1:1.5:3 (1 cement:1.5 coarse sand): 3 graded stone aggregate 20mm nominal size)
Cable Ceiling arrangement at Cable end ( LT Termination Kits)
M/S DEVARYA ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .