Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.5 LAccepted-AOC NEAR ARJAN DEV NAGAR BESIDE ST MARY S CONVENT SCHOOL FARIDKOT | FARIDKOT | FARIDKOT | PUNJAB | 1 | Accepted-AOC ACCEPT | |
| 2 | 2₹3.1 L+₹55,608.20 (22.3%)Rejected-Finance | 2 | Rejected-Finance REJECT |
Tender Value
₹2.1 L
EMD Value
₹4,124
Closing Date
20 Sept 2023, 9:00 amClosed
XEN
EXECUTIVE ENGINEER LDH CANAL AND GROUND WATER DIVN WRD PB LDH NEAR DURGA MATA MANDIR PHASE 1 DUGRI LDH
Estimate for laying pipeline for water course of an outlet at RD 17285/L of Kishanpura Disty.
2023_WR_108625_1
9871/28A
Open Tender
Civil Works
Item Wise
45 days
MOGA
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹4,124
Yes
13 Dec 2023
5 Sept 2023
20 Sept 2023
5 Sept 2023
20 Sept 2023
5 Sept 2023
Amount
Cement concrete 1:2:4 a). with stone ballast or shingle i). mixing by manual means
Cement concrete 1:4:8 a). with brick balast 40mm gauge i). mixing by manual means
Providing, lowering in trenches to correct gradient and alignment, jointing with tyton rubber joint and cutting of reinforced cement concrete spigot and socketed pipes and specials with rubber ring ISI marekd as per IS code IS 458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and fixing of rubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc. B). R.C.C. Pipe NP -2 b). 150mm i/d pipe
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
Cement concrete 1:2:4 a). with stone ballast or shingle ii). mixing by mechanical means volumetric type concrete mixture
First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth
10mm thick cement plaster 1 : 4 on floors.
10mm thick cement plaster 1 : 4
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.
Extra for providing 1:2 cement sand mortar on tytone rubber joint of RCC pipes having sockets extended out of barrel, in trenches including facing trowelling and finishing the joints at the angle of 45 degree with faces of socket keeping joints wet till cured, testing the pipe joints for leakproof and making good all leakage and defects as per specifications. a). NP2 and P-1 S/S joints pipes having internal dia meter: f). 400mm i/d pipe
Earth work in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses, sumps, screening chambers and other similar works having straight or open cuttings in foundations trenches etc. with 3D Excavator/ JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer?in-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering dressing and disposal of surplus soils as directed upto 15 metre complete in all respects. A). Depth upto 1.5 m B.G.L i). All classes of soil except rocky
Providing, lowering in trenches to correct gradient and alignment, jointing with tyton rubber joint and cutting of reinforced cement concrete spigot and socketed pipes and specials with rubber ring ISI marekd as per IS code IS 458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and fixing of rubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc. B). R.C.C. Pipe NP -2 b). 300mm i/d pipe
THE VIJAY COOP L AND C SOCIETY SARAWAN
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .