Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹8.4 L+₹14,338.21 (1.73%)Rejected-AOC | L2 | Rejected-AOC Second lowest | |
| 3 | L3₹8.5 L+₹19,670.17 (2.38%)Rejected-AOC | L3 | Rejected-AOC Third lowest | |
| 4 | L4₹8.9 L+₹62,969.25 (7.60%)Rejected-AOC | L4 | Rejected-AOC Forth lowest | |
| 5 | L5₹9.3 L+₹98,173.57 (11.9%)Rejected-AOC | L5 | Rejected-AOC Fifth lowest |
Tender Value
₹10.4 L
EMD Value
₹20,880
Closing Date
3 Jan 2020, 6:00 pmClosed
GE Palampur
Holta Camp Palampur Kangra (H.P)
SPECIAL REPAIR TO BLDG NO P 97/F (SINGLE JCOS ACCN) OF 298 FD REGT AT ALHILAL MIL STN
2019_MES_303861_1
GEP-57(Token)/2019-20
Open Tender
Civil Works
Item Rate
120 days
Alhilal
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹20,880
Yes
17 Feb 2020
5 Dec 2019
4 Jan 2020
5 Dec 2019
3 Jan 2020
19 Dec 2019
Amount
SCHEDULE 'A' PART-I: Taking down chowkats or frames with shutters (without taking off shutter from the frames) not exc 1.5 sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutter from the frames) exc 1.5 sqm but n. exc 4 sqm each complete all as specified and directed.
M&L second class hard wood, solid straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints as directed
M&L treating small articles such as hold fast with tar or coal tar black paint area n. exc 0.10sqm each complete all as specified and directed.
M&L preparing surfaces of wood & wood based material new or old surfaces of any description treating ends of posts, back of chowkats etc area tarred exc 0.1 sqm but n.exc 0.5 sqm each treated with tar or coal tar black paint complete all as specified and directed.
S&F mild steel hold fast & similar articles confirming to Fe-310-0 or Fe-410 complete.
M&L PCC type B-1, 1:2:4 (Nominal mix) using 20mm graded crushed stone agreegate for cills, block for hold fast, apex stones, bed plates and the like including including necessary form work complete all as specified and directed.
S&F 35mm thick plain framed panlled shutters (any numbers of panels) of 2nd class hard wood with panels of timber flat on both sides or of veenerred particles boards medium density, wood particle board with commercial face veneered complete all as specified and directed.
S&F 35mm thick 2nd class hard wood glazed & skeleton shutters open rebated & prepare to received glass, gauge etc without sash bars, edges of framing plain chamfered or rounded fitted with cut and mitred bids for securing glass etc in window, ventilator etc, sizes of member of shutter as specified.
S&F solid PVC door frames of sizes 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail , lock rail and bottom rail on either side and as gap insert for top rail and bottom rail , panelling of plain colour PVC sheet to be fitted in the MS framewelded/ sealed to the stiles and rails with suitable PVC sheet beading , and jointed together with solvent cement in the frame at site as per specification.
Dismantling expanded metal, any thickness or mesh n. exc 4kg per sqm, fixed with steel or wooden fillets, if any.
S&F galvanized mild steel wire cloth 0.56 mm nominal dia of wire & average width of aperture 1.18mm & fixed with tinned tacks are galvanized wire staples.
S&F in repair galvanized mild steel wire cloth 0.56 mm nominal dia of wire & average width of aperture 1.18mm & fixed with tinned tacks are galvanized wire staples.
S&F100mm long butt hings medium weight cold rolled mild steel & fixed to chowkats all as specified.
S&F150mm long aluminium handle cast type anodised.
S&F 200mm long aluminium anodised barrel towe bolt of extruded section
S&F mild steel sliding door bolts, 300 mm long, plate type, stove enamelled black, with bright bolts not less than 12mm dia with & including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate etc complete.
S&F floor door stopper of aluminium alloy body and tongue 140mm anodised, with hard dran steel spring, fixed in floor complete all as specified and directed.
M&L two coat of synthetic enamel paint over one coat of pink primer, on wood and wooden surfaces of any description , not other wise described, over 10cm width or girth including preparation of new surfaces complete all as specified and directed.
M&L two coat of synthetic enamel paint, surfaces of any description ,not otherwise described, over 10cm width or girth including preparation of old surfaces complete all as specified and directed.
S&F factory made steel window with side shutter including BOX type hings with steel handle, steel peg stay, with glazing bars including applying one shop coat of red oxide primer complete all as specified and directed
S&F factory made steel ventilators with top hung shutters including hinges, steel peg stay,steel handle or welded including applying one shop coat of red oxide primer complete all as specified and directed
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified & directed.
S&F 3.0mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 sqm in each panes complete all as specified and directed.
Preparation of new or previously untreated steel surcaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enammel paint, complete all as specified.
Preparation of old painted steel surcaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enammel paint, complete all as specified.
M&L for 18 to 20 mm thick (table rubbed and polished) marble work of any shade as in steps, jambes pillars window cills cooking flatforms and like in cement mortor (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade over 15mm thick screed bed in CM 1:6 including cutting and polishing complete all as specified and directed.
Machine Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for rounding of edges of granite/kota stone slabs one edge, such as in steps, cooking plateform and other similar situation complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc,
M&L for 5 mm thick rendering in cement mortar 1:3 on concrete surface of ceiling, finished even and smooth without using extra cement.
M&L 15mm thick rendering on fair faces of brick work or concrete surface in CM 1:4 mixed with water proofing compound as per manufacturer's instructions finished even and smooth without using extra cement complete all as specified and directed. Note: Water proofing compound shall measured and paid separetely.
M&L 10mm thick rendering on fair faces of brick work or concrete surface in CM 1:6 to be finished even and smooth without using extra cement.
Supply only integral water proofing compound.
M&L three coats of white wash on newly plastered ceiling surfaces including preparation of surfaces complete all as specified and directed.
M&L two coat of distemper oil emulsion over and including 1 to 2mm thick wall putty on plaster surfaces, prepatory to distempering complete all as specified and directed.
M&L for preparation of new decorated surfaces of walls soffits, facia roof and applying two coat of weather proof acrylic based emulsion paint (100% acrylic) as per manufacturer’s instructions etc complete all as specified and directed.
M&L for preparation of old decorated surfaces of walls soffits, facia roof and applying, two coat of weather proof acrylic based emulsion paint (100% acrylic) as per manufacturer’s instructions etc complete all as specified and directed.
M&L one coat of white wash on old surfaces on ceiling including preparation of old surfaces complete all as specified and directed.
M&L for old surfaces on walls and applying two coats of distemper oil over and including 1 to 2mm thick wall putty a coat of chalk whiting complete all as specified
M&L for repairing the edge/corner of Chajja/roof projection and similar work by removing of plaster width / girth exceeding 15cm but n. exc 30 cm and making good with 15 mm thick rendering in cement mortar 1:3 to match with including chicken wiremesh netting on existing surface complete all as specified and directed.
M&L for Mild steel work such as Hand rails, half round or other steel section or core for wooden hand rail straight portation, drilled and counter sunk for baluster, nosing to steps including embedding in concrete and screwing etc.over and fabrication and conforming to Fe-290, Gde E-165, complete all as specified and directed
M & L for framed work as in doors or gates of angle or other section with gusset plates, rails braces, etc. complete drilled for fixing of steel sheeting or other covering doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting (exclusive of styeel, sheeting rails and guides ) and hanging; also fastening over and fabrication and conforming to Fe-290, Gde E-165, complete all as specified and directed.
M&L for plain or corrugated steel sheets any thickness in avalible sizes black complete all as specified and as directed.
M&L welding in repairs not exceeding 2.5cm in length and not exceeding 6 mm thick, complete all as specified and directed.
Demolition of cement concrete (Unreinforced) in ground floor and pavings n exc 15cm thick ness (below or above ground level) complete all as specified and directed.
50mm thick, PCC M-10 (Nominal Mix), type C-1 (using 40mm graded crushed stone aggregates) as in plinth protection/foot path finished even and smooth without using extra cement, complete all as specified and directed.
M&L PCC 1:2:4 type B-2, 75 mm thick, using 40mm graded aggregate as in sub base of flooring finishing the surface even & fair without using extra cement complete all as specified and directed.
Coloured chequered cement concrete tiles, machine pressed, factory made of size 300 x 300 x 25mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and incl 15mm thick screed bed or bedding layer in CM 1:6, complete all as specified and directed.
M&L for fine aggregate (sand) for concrete surface complete all as specified and directed.
M&L glazed machine pressed precast concrete coloured interlocking paver block laid in floor with grey cement and and pigment, any shape and size conforming to IS-15658-2006 of 60mm thickness M-35 grade over and incl 50 mm thick layer of sand cushioning, complete all as specified and directed .
Dismantling floor, hearth wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store & rubbish off the premises.
M&L for joint free (edge cut) coloured glazed ceramic tiles 7 mm to 8 mm thick (square / rectangular) polished of size 300x 450x 7 mm/ 300X 600X 7mm as in skirting / dado etc laid over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete.
M&L for Non skid, joint free (edge cut) coloured ceramic tiles 7 to 8 mm thick (Square / rectangular) polished area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete.
M&L for Non skid, joint free (edge cut) coloured ceramic tiles 7 to 8 mm thick (Square / rectangular) polished area of each tile exceeding 0.18 sqm butt not exceeding 0.38 sqm as in floors etc laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete.
All as per the description of serial item No 56 but in skirting including 10mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete.
M&L for cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) 25mm thick as in sub base of flooring & roof complete all as specified and directed.
M&L for cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) 50 mm thick as in flooring & roof finishing smooth using with extra cement complete all as specified and directed.
Taking up or down 15mm bore dia steel water tubing and connection, including cleaning for refixing or removal to store, complete all as specified and directed.
Taking up or down 20mm bore dia steel water tubing and connection, including cleaning for refixing or removal to store, complete all as specified and directed.
Taking up or down 25mm bore dia steel water tubing and connection, including cleaning for refixing or removal to store, complete all as specified and directed.
Steel water tubing, 15mm bore dia, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor including cutting chases for concealed work etc, complete all as specified and directed.
Steel water tubing, 20mm bore dia, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor including cutting chases for concealed work etc, complete all as specified and directed.
Steel water tubing, 25mm bore dia, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor including cutting chases for concealed work etc, complete all as specified and directed.
Cutting chase, pinning in making good to faceing where required and pointing in cement mortar 1:3 to ends or edges of landing, and cutting chase for concealed water tubing or concealed conduit wiring etc and making good cutting exc 10cm but n exc 20cm complete all as specified and directed.
Dismantling of 75/100 mm dia cast/PVC drain pipes, jointed in cement mortar fixed in trenches and taking out of trenches removing where directed complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore dia, single socketed, in any length with rubber ring joints, laid in trenches or in floors etc including taking down and removal from site, complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore dia, single socketed in any length with rubber ring joints fixed to walls etc including taking down and removal from site, complete all as specified and directed.
S&F PVC (SWR) bends 75mm bore dia complete all as specified and directed.
S&F PVC (SWR) bends 110mm bore dia complete all as specified and directed.
S&F PVC (SWR) 'P' trap 75mm bore with grating.
S&F 500 ltr rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 25 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe (including dismantling) complete all as specified and directed.
S&F in repair vitreous china Semi pedestal pattern (Anglo Indian type) white connection to trap 'P' or 'S' and flush pipe etc seat cover and making good to disturbed surfaces of floor by filling with PCC 1:4:8 type D-2 to match with existing including taking down the existing old one complete all as specified and as directed.
Vitreous china squatting pan water closet, orissa pattern, size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including PVS (SWR) 'S' trap, including provision of lime concrete and jointing to flush pipe (fixed in repair), complete all as specified and directed.
Supply and fix in repairs 10 litres capacity PVC symphonic action type flushing cistern (ISI Marked) low level with inlet ball valve, float and handle & PVC flush pipe, fixed in position and connecting complete.
Vitreous china, wash hand basin, (white) of size 550mmx400mm including brass CP waste coupling 32mm dia with long screwed shank and fly nuts, PVC medium grade 32mm dia waste pipe, chain and plug, porcelain stopper , PVC connection 15mm dia, 450mm long with brass CP nuts and washers at both ends (fixed in repair), complete all as specified .
S&F in repair tubular towel rail, 20mm dia, 60 cm long, CP with a pair of brackets, fixed to wall with CP brass screw and PVC rawl plugs ,complete all as specified and directed.
S&F in repairs soap dish any type fixed to plugs with chromium plated brass screws.
CP Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms), complete all as specified and directed.
S&F in repair bib taps 15mm bore cast copper alloy with crutch or butterfly, handle, screwed down, screwed for iron pipe.
S&F in repair pillar taps 15 mm bore cast alloy with capasten head screwed down high pressure with without lettered 'Hot' or Cold with long screwed shanks and fly-nutsscrewed for iron pipe and fixed
S&F in repair stop valve 15mm bore cast copper alloy with screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions complete.
S&F in repairs harrison rails stainless steel with fixing brackets on both side, stops rollers etc. complete all as specified and directed.
S&F towel ring of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 90 gms) complete all as specified and directed.
S&F swivel shower of PTMT any colour for fixing with 15mm dia pipe (Min weight 40 gms) complete all as specified and directed.
S &F shower arm 15mm size 195mm long with bend of 45 degree with flange of PTMT any colour (Min weight 40 gms) complete all as specified and as directed.
M&L Water proofing treatment on RCC roof etc. comprising with the following operation & as specified herein below:- (a)Taking down existing old tarfelt, bituminous compound including cleaning & removing debris as specified and as directed. (b) Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) (c)Preparing & cleaning of fully dried cement concrete surface. (d) Applying one coat of cold bituminous primer to the plastered surface @ 0.30 litres per sqm conforming IS-3384. (e) A layer of APP based polymeric membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric.The over lap shall be minimum 75 mm in length side and 100 mm with side. Application of polymeric membrane shall be by torch application as specified and as directed.
M&L 10mm thick rendering on fair faces of concrete surface is in cm 1:3 to be finished even and smooth with out suing extra cement under roof treatment mixed with water proofing compound (to be measured and paid seperately)
SCHEDULE 'A' PART-II: Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Point wiring with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in & incl PVC surface casing 'N' capping double lock type to be fixed with the help of rawal plugs & screws incl necessary fittings & fixture and to be turminated in sunk cast iron/pressed steel/PVC terminal boxes for mounting switches, sockets, regulators etc with 3 mm thick plastic laminated sheet cover of adequate size for one light point/fan point controlled by one switch and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified.
All as per the description of serial item No 92 above but for 5 pin switch socket outlet 5 Amp on same board with other switches, complete all as specified.
All as per the description of serial item No 92 above but for 5 pin switch socket outlet 5 Amp on independent board complete all as specified.
All as per the description of serial item No 92 above but with 2.5 Sqmm PVC (FRLS) insulated copper conductor cable and 2.5 Sqmm PVC (FRLS) insulated copper conductor as earth wire for one 3 Pin 15 Amp socket out let on the independent board.
S&F switch piano flush button, 5 Amps, 240 volts, single pole one way complete all as specified and directed.
Supply and fixing socket out let 2 in 1, 3 Pin 5 Amps flush type complete all as specified and directed.
Supply and fixing switch socket combination out let 2 in 1, 5/6 Pin, 5 and 15 Amps flush type all as specified and directed.
S&F lamp holder, insulated body, with back plate for batten fitting with LED Lamp 3 W, complete all as specified.
Supply and fixing bell push complete all as Specified.
Supply and fixing electronic bell ding dong type complete all as Specified.
S&F LED batten T-8, 1x20 W including LED tube Rod 20W complete with provn of flexible cable 3 core, 23/.0076 from ceiling rose to connector complete all as specified and directed.
Taking down old burnt out bulk head fitting any type and installaton LED Bulk Head 10W with pressure plastic housing with clear prismatic diffuser, high efficient LEDs IP54 complete all as specified and directed.
S&F ceiling rose surface type bakelite 50x65 mm two to three terminals all as specified.
Material and labour for sub main wiring with two single core PVC insulated, FRLS unsheathed multi stranded copper conductor cable confirming to IS 694-1990 of size 4 Sqmm (nominal area) and draw in & including PVC surface casing 'N' capping double lock type to be fixed with the help of rawal plugs & screws incl all fittings such as Tee, connector pieces, L-junction etc on joints, not less than 2 mm thick and continuous PVC insulated single core copper conductor multi stranded unsheathed 4 Sqmm as earth wire complete all as specified and as directed. (Two single core cable and one earth wire shall be measured together as one length) including making good the disturbed surfaces.
Taking down ceiling/exhaust fan any type/size and refixing at same or other location after cleaning, greasing, oiling & servicing complete all as specified and directed.
Supply and fix distribution board iron clad, vertical DB double door with IP-43 protection suitable for MCB TPN as incommer and MCB as outgoing 415 Volts 3 phase 50 Hz 4 way, complete with appropriate size copper busbar and neutral link complete with one MCB TPN 415 Volts 63 Amps rating, 16 KA breaking capcity of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site and including taking down old unserviceable existing DB any type/size complete all as specified and directed.
Supply and fix sheet metal enclosure powder coated DB for fixing of MCBs, SPN 4 ways double door, IP-42 protection with 200 Amp rated bus bar, 240 Volts including taking out of old MCB DB of any type/size and removing from site to MES store for reuse if serviceable or for credit complete all as specified and directed.
Supply and fix MCB SPN 240 volts, 10kA, 50 Hz of capacity 40-63 Amps 'C' series all as specified and directed
S&F MCB SP, 240 V, 6-40 Amp 10 KA complete all as specified.
Earthing with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit less than 2.25 mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr deep below normal ground level, connected to 4mm dia galvanized iron wire as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel complete with 15mm dia light grade protection pipe, 20mm dia GI light grade watering pipe with funnel including char coal dust, salt, PCC 1:2:4 in pit with precast RCC M-15 cover reinforced with XPM not less then 4.00 Kg per sqm including necessary earth work in any type of soil, removal of surplus soil to a distance not exc 50m, returning filling in complete as shown in electrical plate No 3 of SSR Part-I (2009), and connected to earthing test point all as specified or indicated, including testing on completion. Note: The rates for earthing includes the cost of earth lead and protection pipe upto 7.50m length.
Supply, laying and testing cable XLPE insulated screend PVC bedded, galvanised steel strip or wire armoured electric power cables (Heavy duty) 1100 V grade with stranded aluminium conductor of size 16 sqmm, 4 Core, laid in trenches or passing through pipe including taking down of existing cable/service connection of any type or size and removing from site to MES store for reuse if serviceable or for credit all as specified and directed and directed.
Excavation in trenches not exc 1.5m wide and not exc 1.5m deep in any type of soil for laying cables, foundation of poles etc and getting out complete all as specified and as directed.
Returning, filling in, including spreading, levelling watering and well ramming in layers not exc 25cm complete all as specified and directed.
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Sand cushioning to underground cable provided with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable. The top layer of 15cm shall be punned to 10 cm (total 18 cm) complete all as specified and directed.
Brick common burnt class 'B' covering laid dry, flat transversally along the length of the cable on sand cushioning width equal to the length of the brick complete all as specified.
S&F 40 mm dia bore galvanized iron tubing, light grade including all fitting for cable protection elc laid in floor, trenches or fixed to poles with clamps etc all specified and directed.
BHARDWAJ BUILDERS
VIVEKA ENTERPRISES
M/S DOGRA CONSTRUCTION CO
M/S THAKUR ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .