Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
31 Aug 2026, 3:00 pm2d left
Sudipta Bose (EE/EL)
nbdd uttarkanya
Construction of Bathing Ghat, Paver block Road, Beautification with others allied works at Radha Kundu Shyam kundu Madan Mohan Mandir at Ramkeli under English Bazar Block in the district of Malda- Electrification work.
2026_NBDD_1038264_8
NBDD/BS/EE /NIQ-16- (EL) of 2026-2027(SL No. 01 to 10)
Open Tender
Electrical Work/ Equipment
Item Rate
120 days
Malda
Please refer Tender documents.
6 documents required · 6 mandatory
₹50,000
Yes
14 Aug 2026
14 Aug 2026
3 Sept 2026
14 Aug 2026
31 Aug 2026
14 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying Installation, Testing and Commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.
200 A TPN (Make L&K/Havells/HPL) | - | Each | - | - |
| 2 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .
8 way (4 + 24), Double door (Make Legrand/Schneider/Siemens) | - | Each | - | - |
| 3 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way , Double door (Make Legrand/Schneider/Siemens) | - | Each | - | - |
| 4 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
150 A, 16 KA,TPMCCB (Make Legrand/Schneider/Siemens) | - | Each | - | - |
| 5 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make Legrand/Schneider/Siemens)
(a) Single pole | - | Each | - | - |
| 6 | (b) Double pole | - | Each | - | - |
| 7 | (c) Triple pole | - | Each | - | - |
| 8 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 A (Make Legrand/Schneider/Siemens) | - | Each | - | - |
| 9 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required. (Make Legrand/Schneider/Siemens) | - | Each | - | - |
| 10 | Wiring for light point/ fan point/ exhaust fan point/ call
bell point with 1.5 sq.mm FRLS/HFFR PVC insulated
copper conductor single core cable ( Make Polycab/Havells/RR Cabel) in surface/recessed medium class PVC conduit, with modular
switch, modular plate, suitable GI box and earthing
the point with 1.5 sq.mm FRLS/HFFR PVC insulated
copper conductor single core cable etc. as required. | - | Point | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.47 MB
Tendernotice_2.pdf
PDF • 0.51 MB
BOQ_2550560.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].