Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69.8 LAccepted-AOC PSRA 146 A PULIMOOTTIL ROAD PADAMUGAL INDRA JUNCTION KAKKANAD PO KOCHI 682030 | KOCHI | ERNAKULAM | KERALA | 682030 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹70.6 L+₹82,509.03 (1.18%)Rejected-AOC 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹72 L+₹2.2 L (3.19%)Rejected-AOC BLDG NO 22 2079 COAST GUARD ROAD NEAR COAST GUARD FAMILY ACCOMMODATION MUNDAMVELI PO PALLURUTHY VII ERNAKULAM 682 507 | ERNAKULAM | ERNAKULAM | KERALA | 682507 | L3 | Rejected-AOC Rejected |
Tender Value
₹73.5 L
EMD Value
₹1.4 L
Closing Date
25 Dec 2023, 6:00 pmClosed
CWE (NW) KOCHI
CWE (NW) KOCHI
PROVN OF COVERED SHELTER FOR MAIN GATE, PROVN OF PARKING SHED NEAR P-37 BLDG SAILORS MARRIED ACCN, PROVN OF CHAIN LINK FENCING, FOOTPATH AND DRAINAGE SURROUNDING OF CHILDRENS PARK IN MD ACCN AREA, PROVN OF DEFDFIRE POINTS AND INSTALLATION OF EXISTI
2023_MES_629054_1
CWE(NW)KOCHI/81403
Open Tender
Civil Works
Item Rate
270 days
KOCHI
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE(NS) KOCHI
₹1.4 L
Yes
21 Feb 2024
20 Nov 2023
27 Dec 2023
20 Nov 2023
25 Dec 2023
11 Dec 2023
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard dense soil complete all as specified.
As per item No:1 above but Exc 1.5 m depth and n.exc 3.0m depth complete all as specified and as directed by Engineer in Charge
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,in hard/dense soil including removing of soil complete all as specified and directed by Engr-in-charge.
M&L for Cement concrete in foundations, filling and mass-concrete using type D2 1:4:8 (40mm graded aggregate) complete all as specified.
M&L RCC M-30(20mm graded aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns etc complete all specified and as directed by Engineer in Charge
M&L RCC M-30(20mm graded aggregate) as in Columns, pillars, piers, posts and struts etc complete all specified and as directed by Engineer in Charge
Formwork to sides of concrete foundations ( Flat Rough finished surfaces ) concrete, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all specified and as directed by Engineer in Charge
Formwork to sides of pillars,posts, struts, piers, columns for square ,rectangular or polygones and stanchions finished even and fair complete all specified and as directed by Engineer in Charge
M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all specified and as directed by Engineer in Charge
M&L 16 to 20mm dia of mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.5cm and N.exc 30cm long complete all specified and as directed by Engineer in Charge
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified.
S& F in wind ties for roof,cladding angle/ flat sections including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as spd and as directed by Engineer in Charge
S/F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S/F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L Hardcore of broken stone or boulder of guage exc 63mm but n exc. 100 mm, deposited,spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all specified and as directed by Engineer in Charge
M&L 150mm thick PCC 1:3:6 type C2 (40 mm graded aggregate) and finished even and smooth without using extra cement.complete all specified and as directed by Engineer in Charge
Returning, filling in, hard/dense soil including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all specified and as directed by Engineer in Charge
Removing excavated material exc. 250 and not exc 500m and depositing where directed at a level n exc. 1.5 m above the starting point for hard /dense soil complete all specified and as directed by Engineer in Charge
Surface excavation n exc 30cm deep and averaging 15 cm deep and getting out in Hard/Dense soil complete all as spd and as directed by Engineer in Charge
Material and labour for soling (or sub base) 150 mm thick (spread thickness) in one layer with broken boulders or quarried stone, interstices filled, surface formed and rolled using power roller 8 to 12 tonne capacity and consolidated to required gradient and camber etc. complete all as specified and as directed.
M&L for 100mm thick PCC 1:4:8 type D2(using 40mm graded stone aggregate) complete all as specified and directed by Engr-in-charge.
M&L for 12.5mm Graded coarse aggregate cushing of paver tiles with Spreading and levelling in layers n exc. 25 cm thick in each layer (25mm +25mm ) complete all as spd and as diretced by Engineer in Charge
M&L Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 80mm thick M-40 grade etc complete (with grey cement and pigment) over aggregate cushioning.complete all as spd and as diretced by Engineer in Charge
M&L for PCC 1:2:4 type B1(using 20mm graded stone aggregate) as in coping,bed plates, rounded or chamfered on edges, kerb not provided for etc complete all as specified and directed by Engr-in-Charge
M&L for Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as spd and as directed by Engineer in Charge
M&L 40 mm thick Cement concrete 1:2:4 (20mm graded aggregate) floor topping etc complete all as spd and as directed by Engineer in Charge
M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick,or 30cmx30cmx25mm thick set, jointed and pointed in neat cement slurry in floors with grey cement & pigments. With Screed bed or bedding layer or mortar 20mm thick for laying floor finishes in CM 1:6 complete all as spd and as directed by Engineer in Charge
Excavation over area in any type of soil not exceeding 1.5 meters wide and not exceeding 1.5 meters in depth and getting out in hard/dense soil complete all as specified.
Removing excavated material (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified.
M&L Cement concrete type B2 1:2:4 (40 mm graded aggregate)in foundations, filling and mass concrete,post holes fillings etc complete all as spd and as directed by Engineer in Charge
M&L pre-cast cement concrete block masonry with solid blocks, exc 10cm in width and setting in mortar, complete type B1 1:2:4 (20mm graded aggregate) complete all as spd and as directed by Engineer in Charge
M&L cement concrete 100mm thick type C-2, 1:3:6 (40mm graded aggregate) complete all as spd and as directed by Engineer in Charge
M&L P.C.C (1:2:4), 100mm thick type B-1, (20mm graded aggregate) complete all as spd and as directed by Engineer in Charge
Preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of redoxide primer on steel surface
M&L for Cement concrete Type C-2 (1:3:6) using 40mm graded stone aggregate as in foundation of drain complete all as specified.
M&L for Cement concrete Type B-1 (1:2:4) using 20mm graded stone aggregate as in coping of drain complete all as specified.
Extra for forming fair finished drain or channel 45cm inner girth in cement concrete using extra cement, including forms, mould and mitred/stopped ends complete all as specified.
M&L for Precast Cement Concrete block masonry with solid blocks, Type C1 1:3:6 using 20mm graded stone aggregate exc. 10cm in width and setting in Cement Mortar 1:4 complete all as specified.
M&L 10 mm thick rendering on concrete surfaces in Cement Mortar 1:4 finished fair and even w/o using extra cement complete all as specified.
M&L Precast cover in RCC 1:2:4 Type B1 as in cover slabs set in Cement Mortar 1:4 including necessary formwork all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, laying of pipes, cables, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil.
S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes notching for wire etc. flat iron pillars for securing wire mesh including all necessary drilling, bolting, rivetting etc and similar works confirming to Fe-290-Gde E165 all as specified and directed.
S&F round bars 10mm dia cut to length, bent to shapes required including cranking, bending, spirally hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9m dia all as specified for chain link fencing.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standard rails, straining bolts etc. including provn of binding.
Supply only chain link MS galvanated fencing any size or type all as specified
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 5cm but not exc 10cm long with diameter of neck 5 to 10mm all as specified and directed.
M&L for preparation of steel and iron surfaces of any description n.exc 10cm in width or girth and apply two coats of synthetic enamel paint over a coat of redoxide all de all as specified and directed
Rendering 15mm thick cement plaster on fair faces of brick work in cement mortar 1:4 finished even and smooth without using extra cement
M&L preparing plastered or unplastered new surfaces and applying two coat of cement based paint over one coat of alkali resistant priming paint all as specified and directed.
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc, complete, drilled for fixing of steel sheeting or other covering. Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittigs (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete with Fe 410 W, quality B all as specified and directed.
S&F Mild steel bars 10mm dia and overFe- 410-W, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
M&L for second class hard-wood in scantlings framed and fixed all as specified and directed.
M&L for second class hardwood supplied & fixed with nails in any situation (except flooring & skirting) clean sawn with butt joints of thickness 25mm, fixed in shelves; partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work all as specified and directed.
M&L three coats of white washing on walls all as specified and directed.
S&F Fe-410-W roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle,channel or flat sections) including distance pieces, cleats etc all as specified and directed.
M&L Preparation of wooden surafces of any description, not otherwise described, over 10cm width or girth with two coats of synthetic enamel over one coat of pink primer all as specified and directed.
S&F framed work such as grills, gratings etc with ends of bars shouldered or riveted or forged into spikes; framed guard bars; barred iron doors; ladders and similar works confirming to Fe.290.Gde-E-165 all as specified and directed.
M&L cement concrete type B2 1:2:4 (40mm graded aggregate) in foundations, filling and mass concrete all as specified and directed.
M&L 75 mm thick Cement concrete B-1, 1:2:4 (20mm graded aggregate) floor topping etc complete all as specified and as directed by Engineer in Charge
M&L providing PCC solid blocks exc. 10cm in width type C1 1:3:6, 20mm graded aggregate and setting in cement mortar 1:6 complete all as specified and as directed by Engineer in Charge
M&L for Finishing walls with Acrylic Smooth exterior emulsion (Anti Fungal Nature) paint of (as approved/ required shade) of New work over a coat of exterior grade primer (Two or more coat applied @ 1.67 Itr/10 sqm over and exterior primer applied @ 2.20 kg/10 sqm) completed all as specified and directed
M&L for Granite 20mm thick machine cut, bedded andjointed with grey cement slurryand pointed with white cementwith admixture of pigment to match the shade of granite stone including grinding and polishing with 15mm thick screed in cement mortar (1:6) complete all as specified
M&L for 20mm thick Granite (of any type)tiles machine cut, in skirting/dado etc laid over 10mm thick cement mortor (1:4) and jointed with grey cement slurry, and pointed with white cement with admixture ofpigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.
M & L For One light point controlled by one switch with PVC single core unsheathed copper conductor multistranded cables FRLS 1.5 sq. mm size drawn through and including PVC conduit of suitable size concealed and all accessories, fire resistant, ISI Marked including standard size GI sheet pressed modular terminal box (recessed) with top cover including PVC single core unsheathed copper conductor multistranded cables FRLS 1.5sq as earth continuity conductor and making good the disturbed surfaces of walls/floors/ceiling etc all as specified and directed.
As per item No 64 but One ceiling fan point controlled by one switch all as specified and directed
As per item No 64 but One 3 pin socket outlet 5 amps on the independent board all as specified and directed
As per item No 64 but One 3 pin socket outlet 5 amps on same board all as specified and directed
As per item No 64 but with cable 2.5 sqmm for One 3/5 pin socket outlet 15 amps on the independent board all as specified and directed
Supply and fix Modular switch 1 way 6A/10, 1 module all as specified and directed
Supply and fix Socket, 6A-2/3 pin combined 2 module all as specified and directed
Supply and fix Socket 6A/16A-2/3 pin combined 2 module all as specified and directed
S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body, 65 x 50mm, 3 terminals all as specified and directed.
S & F Modular stepped type electronic Fan step regulator, 120W-2 module
Supply and fix new generation energy saving and environmental friendly long life LED high bay light 80 watt in pressure diecast aluminium housing suitable for industrial application, Lumen efficiency not less than 140 lumen/watt and upto 150 lumen/Watt with IP66 Protection including fixing arrangements Hanging chains etc, complete all as specified and directed.
M&L for submain wiring with 2 runs of single core 1.5 sqmm PVC insulated unsheathed multistranded copper conductor cable FRLS, ISI marked alongwith 1 runs of 1.5 sqmm multistranded insulated copper conductor cable as earth continuity conductor drawn through and including PVC conduit of suitable size on surface/ recessed as required. Note: 2 Runs of PVC wires of 1.5 sqmm and 1 run of 1.5 sqmm earth wire and one run condit will be measured as one unit).
Supply and fix thermoplastic polycarbonate SPN DB, 8 way/module, 220 Volts, in accordance with IEC 61439-3 hinged flap type shock proof, Rust free, Corrosion free, acid and chemical resistance, fire retardant, self extinguishing PE N terminals, IP 65 Protection including dismantling old one all as specified and directed. Make Hensel/Spelsberg/Rittal
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32 Amps in the MCB DB complete with connection testing and commissioning.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP. in the MCB DB Complete with connection testing and commissioning
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation, laying of pipes, cables, etc or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil. all as specified and directed.
Supply and spreading locally available riddle sand for covering and cushining of UG Cable in trenches complete all as specified
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat size 250 mm x 150mm x 40mm. all as specified and directed.
Supplying laying, jointing and testing Tubes, 'light grade' galvanised with all fittings and fixed complete to walls or laid under road for passing cables complete of size 40mm all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2 core.
M & L for Earthing complete with GI Steel earth plate electrode 600 × 600 × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers, with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth wire of size 4 mm, dia by means of bolts, nuts, check soldered and revetted to earth plate. Earth wire will be protected by using 15mm dia bore Gl pipe light grade. The earthing includes PCC Pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 mtrs etc complete all as shown in electrical plate No. 3 of SSR Part-1 2009 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed.
Supply laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm x 2 core all as specified and directed.
S&F hot dipped GI Octagonal pole of 5 mtrs long with single arm, complete arrangement suitable for mounting of LED Street light fitting, with bottom dia 130mm, top dia 70mm with 3mm sheet thickness and foundation nut bolts complete including necessary earth work excavation, PCC, RCC in (1 15:3) as per OEM Drawings attached. (Rate quoted includes all connected works such as excavation,PCC.RCC. Reinforcement nut bolts etc)
Supply & Fixing new generation, energy saving and environmental friendly long life LED Street light 45 watt, made up of pressure die cast aluminium housing, toughened glass with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP 66 Protection and impact resistant of IK07 with 10KV Built in surge protection device all as specified and directed.
Material and Labour for PCC 1.2.4 type B-1 using 20 mm graded crushed stone aggregate for filling of road cuttings etc all as specified and directed by Engr-in-Charge
Supply and fix 3 core flexible Aluminium cable 4 sq mm from cable junction box to street light fitting with and including ERW Steel conduit of 20 mm dia with clamps nuts, bolts etc complete all as directed
Supply & Fix Modular switch 1 way 16A, 1 module all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, of size 1400mm with Min Air delivery 245 CFM and services value 6.0 Five star rated with brushless direct current motor (BLDC) all as specified and directed.
Supply and lay MS pipes heavy grade of size 25mm with all fittings laid in floors or fixed to wall and ceiling etc of sizes as shown complete all as specified and directed.(for hanging ceiling fans)
WELTRONENGINEERINGSERVICES
FUTURE ONE FACILITY MANAGEMENT
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .