Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC VILLAGE KANDO P O DUGANA TEHSIL PAONTA SAHIB DISTRICT SIRMOUR H P | PAONTA SAHIB | SIRMOUR | HIMACHAL PRADESH | L1 | Accepted-AOC Awarded | |
| 2 | L2₹1.1 Cr+₹5.8 L (5.67%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹1.2 Cr+₹16.2 L (15.9%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹1.3 Cr+₹24.9 L (24.4%)Rejected-Finance HOSPITAL ROAD SOLAN TEHSIL SOLAN DISTRICT SOLAN HP | SOLAN | SOLAN | HIMACHAL PRADESH | L4 | Rejected-Finance Rejected |
Tender Value
₹83.5 L
EMD Value
₹1.2 L
Closing Date
10 Apr 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Jal Shakti Division Shillai
Executive Engineer Jal Shakti Division Shillai
SH C O Sedimentation Tank 44000 Ltrs Cap C O RCC Filter Bed 36.57 sqm C O RCC Circular Sumpwell 60000 Lltrs Cap C/O 3 Nos RCC Circular Sumpwell 40000 Ltrs Cap C O RCC Circular Sumpwell 25000 Ltrs Cap Providing and Laying Jointing MSERW and Laying J
2023_HPIPH_71768_1
SHL-SMR03-780-JSV DIVSHILLAI-10610-60 Dt 31.03.23
Open Tender
Pumps/Motors
Item Rate
365 days
Shillai
Please refer Tender documents.
9 documents required · 9 mandatory
₹800
Executive Engineer Jal Shakti Division Shillai
₹1.2 L
Yes
5 Jul 2023
31 Mar 2023
11 Apr 2023
31 Mar 2023
10 Apr 2023
31 Mar 2023
Amount
Pumping machinery. ( Booster stage ).
Supply, erection, testing & commissioning of Submersible pumping set of reputed make KSB /BS/Johnston/ Worthington conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor.The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:-2 Set of 5 HP each
Total Head in mtrs (i/c depth of column pipe in case of t/well) 32.00 Meter
Capacity (in LPS) 6.09 LPS
Dia of R/Main (in mm) 65 mm
Providing and fixing of auto control panel with push button star delte started (2 Nos) for submersiblel pumps of L&T and reputed make fabricated with M.S sheet and Angle stand duly painted and complete with internal wiring . comprising of main switch of suitablwe Amp .T.P Volt meter . copper busbar ammeter hour run meter . phase indicating lamps with GSM Based, Remote start /stop operation call / SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day, inbuilt Protection against overload / undervoltage .Dry run single phase preventor inbuilt GPS tracker . phase reversal configurable volt / current limits with a facilty to access the system through minimum 10 nos authenticated mobile nos complete in all respect including entire carriage of materials upto all leads and lifts installation and testing at site with entire satisfaction of Engineer -in charge .(All meters to be installed be DIGITAL)
Supply and fitting of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of suitable size cast iron double flanged sluice valve having size one size higher than the nominal dia of delivery of pump or equal to dia of column pipe (in case off T/well) and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) (+) Surge pressure conforming to API-standards with up to date ammendments for delivery line of pump Class of Valve shall be PN1
Supply and fitting of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of suitable size cast iron double flanged swing check type reflux valve having bye pass arrangement & size one size higher than the nominal dia of delivery of the pump or equal to dia of column pipe (in case of T/well) and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) (+) Surge pressure conforming to API-standards with up to date ammendments for delivery line of pump Class of valve shall be PN 1.6
P/L & fixing suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L at site PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from circuite breaker to motor & motor to starter including all other electrical equipments such as thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
Supply & errection of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
Providing and Lowering MSERW column pipe assembly of grade A and 65mm ,4.80 mm thickness including MS flanges of Table -28 as per IS -3183-2007 with up to date amendments, rubber/asbestors gasket of maximum 3 mm thickness as per IS:2712-1979 and required numbers of nuts and bolts as per 1364-1983. The column pipe shall be as per relevant IS:-code and to with stand 1.5 times the total head stipulatd under item No 5(a).The column pipe should be extented up to 5mtrss. beyond the outer wall of the pumphouse in the direction of Riing main. The column pipe should be joined with the Rising main including all necessary accessaries like increaser/reducer,flanges, tees, bends etc. including supporting clamps (2 nos) at the top of assembly and conforming and as per the direction of engineer in charge.
1st Stage
Supply, erection, testing & commissioning of Cenrtifugal pumping set of reputed make such as KSB/BS/ Johnston/ Worthington/Suitable alloyas per BIS 5659 or latest up to date ammendments suitable for raw/clear water having greased packed bearings and shell with wound starter on motor side and with shaft protecion sleeve on pump side ensuring better life for shaft confirming BIS specifications. The pump shall be directly cuppled to a submesible squirrel cage electric induction motor of Kirlosker/ NGEF/ Jyoti/ Crompton conforming to relevent BIS Code with upto date ammendments totaly dust and water proof for submersible duly isolated from the pump by intermediate casing with double machenical seal in oil chamber and grese packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand no vertical loads with minimum wear and tear. It should also be fitted with a device take up expansion of water with the heating of motor. The pump set should include water level guard, erection clamps, cable clip and depth gauge etc and suitable for operation on data given below:- 2 Set of 40 HP each
Total Head 460 Mtrs
Capacity of each pump set 2.98 LPS
Dia of R/Main 65 mm
length of Rising main pipe (mm) 1680 Rmt
Providing and fixing of auto control panel with push button 2 Nos star delte started for centrifugal pumps of L&T and reputed make fabricated with M.S sheet and Angle stand duly painted and complete with internal wiring . comprising of main switch of suitablwe Amp .T.P Volt meter . copper busbar ammeter hour run meter . phase indicating lamps with GSM Based, Remote start /stop operation call / SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day, inbuilt Protection against overload / undervoltage .Dry run single phase preventor inbuilt GPS tracker . phase reversal configurable volt / current limits with a facilty to access the system through minimum 10 nos authenticated mobile nos complete in all respect including entire carriage of materials upto all leads and lifts installation and testing at site with entire satisfaction of Engineer -in charge .(All meters to be installed be DIGITAL)
supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar make of cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 9(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump Class of Valve shall be ASA-300
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make of suitable size cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 9(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump Class of Valve shall be ASA-150
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Kartar/Pelicon make of suitable size cast iron /Cast Steel double flanged swing check type reflux valve conirming to API/BIS standard with up to date ammendments for R/main as mentioned in item No.9 (c) for withstanding nominal seat pressure as per item No.9(a) The size of reflux valve shall be equal to size of Rising main of the same shall be provided with suitable bye pass arrangements. Class of Valve shall be ASA-150 and shall be of 65mm diameter
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make cast iron double flanged sluice valve (In case Suction is +ve) for suction pipe having size one or two size larger than suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec and capable of withstanding nominal seat pressure as mentionmed in item No. 9(a) & conforming to BIS/API-standards with up to date ammendments. Class of Valve shall be ASA 150
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
Supply & errection of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
P/F double flanged suction, delivery pipe & common header of MSERW pipe Grade A considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump.Thicness of MSERW pipe shall be 4.40 mm with flanged joint of FT 34
Stage 3rd Phase 1st
Supply, erection, testing & commissioning of Cenrtifugal pumping set of reputed make such as KSB/BS/ Johnston/ Worthington/Suitable alloyas per BIS 5659 or latest up to date ammendments suitable for raw/clear water having greased packed bearings and shell with wound starter on motor side and with shaft protecion sleeve on pump side ensuring better life for shaft confirming BIS specifications. The pump shall be directly cuppled to a submesible squirrel cage electric induction motor of Kirlosker/ NGEF/ Jyoti/ Crompton conforming to relevent BIS Code with upto date ammendments totaly dust and water proof for submersible duly isolated from the pump by intermediate casing with double machenical seal in oil chamber and grese packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand no vertical loads with minimum wear and tear. It should also be fitted with a device take up expansion of water with the heating of motor. The pump set should include water level guard, erection clamps, cable clip and depth gauge etc and suitable for operation on data given below:- 2 Set of 20 HP Each
Total Head 351 Mtrs
Capacity of each pump set 1.93 LPS
Dia of R/Main 50 mm
length of Rising main pipe (mm) 940 Rmt
Providing and fixing of auto control panel with push button 2 Nos star delte started for centrifugal pumps of L&T and reputed make fabricated with M.S sheet and Angle stand duly painted and complete with internal wiring . comprising of main switch of suitablwe Amp .T.P Volt meter . copper busbar ammeter hour run meter . phase indicating lamps with GSM Based, Remote start /stop operation call / SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day, inbuilt Protection against overload / undervoltage .Dry run single phase preventor inbuilt GPS tracker . phase reversal configurable volt / current limits with a facilty to access the system through minimum 10 nos authenticated mobile nos complete in all respect including entire carriage of materials upto all leads and lifts installation and testing at site with entire satisfaction of Engineer -in charge . (All meters to be installed be DIGITAL)
supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar make of cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 15(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump Class of Valve shall be ASA- 150
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make of suitable size cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 15(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump Class of Valve shall be ASA-150
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Kartar/Pelicon make of suitable size cast iron /Cast Steel double flanged swing check type reflux valve conirming to API/BIS standard with up to date ammendments for R/main as mentioned in item No.15 (c) for withstanding nominal seat pressure as per item No.15(a) The size of reflux valve shall be equal to size of Rising main of the same shall be provided with suitable bye pass arrangements. Class of Valve shall be ASA- 150 and shall be of 50mm diameter
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make cast iron double flanged sluice valve (In case Suction is +ve) for suction pipe having size one or two size larger than suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec and capable of withstanding nominal seat pressure as mentionmed in item No. 15(a) & conforming to BIS/API-standards with up to date ammendments. Class of Valve shall be PN 1.6
P/L & fixing suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L & fixing suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
Supply & errection of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
P/F double flanged suction, delivery pipe & common header of MSERW pipe Grade A considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump.Thicness of MSERW pipe shall be 4.40 mm with flanged joint of FT 28 (Note: Actual laying yo be done as per final drawing to be supplied by the Engineer in Charge)
Errection of all equipments of both parts i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Stage 2nd
Replacement of old pumping machinery and then supply, erection, testing & commissioning of horizontal spindle, horzontal split casing radial slit single /multistage centrifugal pumps off Make:KSB Model WL.40/16, pump conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edetion to handel clear water having characteristics as mentioned below in ltem no .22(A), with impelleres,casing ring priming funnels & shaft sleeves of bronze , shaft of steel of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel/ Mild steel to BHEL/ Kirlokar/ NGEF/Crompton/Siemen /jyoti/GEC make slip ring /squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below i/c the cost of all the accessories in all leads and lifts & carriage at the site sites as per direction of Engineer-in - charge. :- 2 Set of 40 HP Each
Total Head 350 Mtrs
Capacity of each pump set 4.68 LPS
Dia of R/Main 80 MM
length of Rising main pipe (mm) 930 Rmt
Providing and fixing of auto control panel with push button 2 Nos star delte started for centrifugal pumps of L&T and reputed make fabricated with M.S sheet and Angle stand duly painted and complete with internal wiring . comprising of main switch of suitablwe Amp .T.P Volt meter . copper busbar ammeter hour run meter . phase indicating lamps with GSM Based, Remote start /stop operation call / SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day, inbuilt Protection against overload / undervoltage .Dry run single phase preventor inbuilt GPS tracker . phase reversal configurable volt / current limits with a facilty to access the system through minimum 10 nos authenticated mobile nos complete in all respect including entire carriage of materials upto all leads and lifts installation and testing at site with entire satisfaction of Engineer -in charge .(All meters to be installed be DIGITAL)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar make of cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 22(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump Class of Valve shall be ASA- 150
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make of suitable size cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 22(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump Class of Valve shall be ASA-150
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Kartar/Pelicon make of suitable size cast iron /Cast Steel double flanged swing check type reflux valve conirming to API/BIS standard with up to date ammendments for R/main as mentioned in item No.22 (c) for withstanding nominal seat pressure as per item No.22(a) The size of reflux valve shall be equal to size of Rising main of the same shall be provided with suitable bye pass arrangements. Class of Valve shall be ASA- 150 and shall be of 80mm diameter
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make cast iron double flanged sluice valve (In case Suction is +ve) for suction pipe having size one or two size larger than suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec and capable of withstanding nominal seat pressure as mentionmed in item No. 22(a) & conforming to BIS/API-standards with up to date ammendments. Class of Valve shall be PN 1.6
P/L & fixing suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L & fixing suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Supply & errection of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
P/F double flanged suction, delivery pipe & common header of MSERW pipe Grade A considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump.Thicness of MSERW pipe 80mm shall be 4.40 mm with flanged joint of FT 28
(Note: Actual laying yo be done as per final drawing to be supplied by the Engineer in Charge)
Errection of all equipments of both parts i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Stage 3rd Phase II
Replacement of old Pumping machinery than Supply, erection, testing & commissioning of horizontal spindle, horzontal split casing radial slit single /multistage centrifugal pumps off Make:KSB Model WL.40/13, pump conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edetion to handel clear water having characteristics as mentioned below in ltem no .29(A), with impelleres,casing ring priming funnels & shaft sleeves of bronze , shaft of steel of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel/ Mild steel to BHEL/ Kirlokar/ NGEF/Crompton/Siemen /jyoti/GEC make slip ring /squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below i/c the cost of all the accessories in all leads and lifts & carriage at the site sites as per direction of Engineer-in - charge. :- 2 Set of 30 HP Each
Total Head 413 Mtrs
Capacity of each pump set 2.69 LPS
Dia of R/Main 65 mm
length of Rising main pipe (mm) 1050 Rmt
Providing and fixing of auto control panel with push button 2 Nos star delte started for centrifugal pumps of L&T and reputed make fabricated with M.S sheet and Angle stand duly painted and complete with internal wiring . comprising of main switch of suitablwe Amp .T.P Volt meter . copper busbar ammeter hour run meter . phase indicating lamps with GSM Based, Remote start /stop operation call / SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day, inbuilt Protection against overload / undervoltage .Dry run single phase preventor inbuilt GPS tracker . phase reversal configurable volt / current limits with a facilty to access the system through minimum 10 nos authenticated mobile nos complete in all respect including entire carriage of materials upto all leads and lifts installation and testing at site with entire satisfaction of Engineer -in charge .(All meters to be installed be DIGITAL)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar make of cast iron/cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 29(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump Class of Valve shall be ASA- 150
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make of suitable size cast iron/cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 29(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump Class of Valve shall be ASA-150
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Kartar/Pelicon make of suitable size cast iron /Cast Steel double flanged swing check type reflux valve conirming to API/BIS standard with up to date ammendments for R/main as mentioned in item No.29 (c) for withstanding nominal seat pressure as per item No.29(a) The size of reflux valve shall be equal to size of Rising main of the same shall be provided with suitable bye pass arrangements. Class of Valve shall be ASA- 300 and shall be of 65mm diameter
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make cast iron double flanged sluice valve (In case Suction is +ve) for suction pipe having size one or two size larger than suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec and capable of withstanding nominal seat pressure as mentionmed in item No. 29(a) & conforming to BIS/API-standards with up to date ammendments. Class of Valve shall be PN 1.6
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Supply & errection of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
P/F double flanged suction, delivery pipe & common header of MSERW pipe Grade A considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump.Thicness of MSERW pipe 65mm shall be 4.40 mm with flanged joint of FT 28
(Note: Actual laying yo be done as per final drawing to be supplied by the Engineer in Charge)
Errection of all equipments of both parts i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Rising Main
Excavation in drains and channels etc, in earth work in all kinds of soil such as kankar Moorum, shingles, Coglomerate saturated soil decomposed or soft rock and hard rock by blasting by chiselling (where blasting prohabitated) including dressing of sides and beds disposing of excavated earth with all leads and lifts disposed earth to be levelled and neatly dressed and then returning the stacked soil into foundation and trenches, etc, including ramming and consolidating the same wherever required with all leads and lifts and including jungle clearance and as per direction of Engieer-in-charge
Providing, laying, testing & commissioning at site in trenches bevelled ended MSERW pipes confirming of various Grades confirming to IS/ISO 3183-2017, latest with up to date amendments having wall thickness & per Rmt weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipes ends shall be bevelled suitable for butt welding including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable ends with up to date ammendments (leak proof) in three layers at site of work with welding rods of standard make and allied accessories whatever required welding at site,tails pieces, tees,bends & other specials manufactured from parent pipes as applicable to the particular reach & of approved specification as per site conditions and cutting of pipes wherever required as per site requirement including carriage in all leads & lifts and as directed by Engineer-Incharge. The pipe shall have zinc coating inside & outside confirming to IS-4736-1986 or latest with up to date ammendments The laying shall confirm to BIS 5822-1970 or latest with up to date ammendments to the entire satisfaction of Engineer-Incharge (Earth work shall be measured & paid for seperately).
Stage 1st
Dia From RD to RD wall thicness FT Grade
Phase I
Laying in trenches to be leveled to grade, GI(H) pipes jointed with flanges confirming to table as specified below of BIS 6392-1971 (Latest with up to date amendments ) welded at both end according to relevant BIS standard & detailed Specifications and provided with nuts and bolts of required size 3mm compressed asbestos fiber gasket of synthetic rubber gaskek conforming to relevant BIS codes including all short pieces, bends tees & other specials etc. made from parent tubes and welded with flanges of tables as applicable for the particular reach of approved specificatoins as per site conditions testing complete to the best satisfaciton of Engineer-in Charge.
Dia From RD to RD Wall thicness FT Grade
65mm 1200 1440 17 GI (H)
65mm 1440 1680 5 GI (M)
Phase I
Dia From RD to RD wall thicness FT Grade
50mm 390 940 17 GI (H)
Civil work
Excavation in foundation and trenches etc.in earth work in all kinds of soil such as pick work ,jumper work decomposed conglomerate saturated soil soft and hard rock upto all leads lifts stacking the excavated soil not more than 3mtr.clear from the edge of excavation and then returning the stacked soil in 15cm layers when required in to plinth sides of foundation etc. consolidating each deposited layers by ramming and watering and then disposing of all surplus excavated earth as directed with in all leads lifts and as per directions of the Engineer-incharge 20mtrs in all kind of soil in P.W & J.W 50% each
Providing and laying cement concrete 1:4:8(1cement:4sand:8 graded stone agg.40mm nominal size)and curing complete excluding the cost of form work in foundation & plinth including all leads lifts and carriage of material and as per the directions of Engineer-in-charge.
Providing and laying cement concrete work 1:1/2:3 (1cement:1-1/2 sand: 3 gradeds stone agg. 20mm nominal size & curing complete) excluding cost of form work and reinforcement for RCC work including all leads lifts complete and carriage of material etc. as per directions of Engineer incharge.
Foundation and plinth
In vertical wall any thickness but not less than 0.10 mtrs thick
Providing form work with steel plates 3.15 thick welded with angle iron in frame 30X30X5mm so as to give rough finish including centering shuttering strutting and propping etc. with wooden battens and bellies, highs or propping and centering below supporting floor to ceiling not exceeding 4mtrs and removal of the same for insitu- RCC work and PCC work including all leads lifts and carriage of material at site and as per direction of Engineer in charge in : -
Flat surfaces such as sofits and suspended floors, roofs landing and the like floors etc. up to 200 mm in thickness.
Vertical surface such as wall (any thickness. Partition and the like i/c attached plasters, buttress , plinth and string course and the like.
Edge of slab
Providing and laying cement concrete 1:2:4 (1cement : 2 app. sand : 4app. graded stone agg. 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced work in suspended floors, roofs landings shelves and their supports balconies, beams, girders bressumers and cantilevers up to floor two level in all height and depth, including all leads lifts and carriage of material at site and as per directions of the Engineer in charge.
Providing Mild Steel/Tor steel reinforcement for RCC work including bending binding & placing in positing I/c all leads lifts and carriage of material and as per direction of the Engineer-in-charge.
Providing and fixing (M.S. Sheet & Angle iron) 600x600 mm dia man hole cover with frame & cantrolling chamber for wheel valve complete in all respect i.e. locking arrqangement etc. (not less than 35 Kg each) and angle iron stir case for up & down (not less than 75 Kg)
Suplying Cast iron manhole cover of 455x610 mm size C.I.(medium) duty the weight of manhole cover not less than 23 kgs.including all leads lifts and carriage of materials as per direction of the Engineer-in-charge.
Proving and fixing M.S. foot rest of 20mm -22mm dia size including embedded in C.C in block 225 mm X 225mmX75mm including all leads and carriage of material at site as per direction of Engineer in Charge
Filter media
Top Layer
Second Layer Coursed Sand
Third Layer Bazari 6mm to20mm
Fourth Layer 20mm to25mm
Fifth Layer Broken Stone
Fixing GMS ventilation pipe/overflow pipe and in walls ,floor ect. including tube fitting and making the wall floor etc. good i.e. welding with one feets 25mm flat iran both side of req. pipes
25mm to 32mm dia
Providing & fixing controlling arrangement with (25 to 32 mm dia wheel valve i/c all type of tube fitting complete
Distribution system
Excavation in drains and channels etc. in earth work in all kinds of soil such as pick work jumper work, blasting work decomposed conglomerate saturated soil soft rock and hard rock including dressing of sides and beds and preparation of sub grade to level or slope including refilling the trenches and disposing of surplus earth up to all leads lifts disposed earth to be leveled and neatly dressed including jungle clearance and as per direction of Engineer in charge.
Laying & Jointing of GMS (L) pipes of various dia in trenches (earth work in trenches to be measured and paid for separately) including all leads lifts and carriage of material at site as per direction of Engineer in charge.
40 mm dia
25 mm dia
20 mm dia
15 mm dia
Thakur Traders
Suneel Dutt
Surjeet Singh Thakur
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .