Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 CrAccepted-AOC | ₹37.7 Cr Quoted ₹37.8 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹38.0 CrRejected-Finance | ₹38.0 Cr | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹40.0 CrRejected-Finance | ₹40.0 Cr | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹40.4 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹40.4 Cr | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹43.3 CrRejected-Finance | ₹43.3 Cr | L5 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹15 L
Closing Date
18 Mar 2021, 6:00 pmClosed
CE Navy Visakhapatnam
CE Navy station Road Visakhapatnam
DEMOLITION RECONSTRUCTION OF SAILORS MD ACCN_144 DUS_ AT NSB VISAKHAPTANAM
2021_MES_417261_1
CE_Navy_VIZ_Token_34_of_2019 -20
Open Tender
Civil Works
1080 days
Visakhapatnam
Please refer Tender documents.
14 documents required · 14 mandatory
₹3,000
Garrison Engineer Project Navy Visakhapatnam
₹15 L
CE Navy station Road Visakhapatnam
6 Apr 2021
29 Jan 2021
19 Mar 2021
29 Jan 2021
18 Mar 2021
9 Mar 2021
8 Feb 2021
Amount
Schedule "A" Part – I to Schedule "A" Part – XVI: NOTE: Schedule "A" Part – I to Part – XVI are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "Buildings & Structures", as listed in Schedule "A" Part – I on Serial Page No. 32.
Lumpsum price worked out by the contractor for "SITE CLEARANCE / AREA DEVELOPMENT/EARTH WORK/EXCAVATION", as listed in Schedule "A" Part – II on Serial Page No. 34[R].
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – III on Serial Page No. 36[R].
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – IV on Serial Page No. 38[R].
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL", as listed in Schedule "A" Part – V on Serial Page No.40.
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part – VI on Serial Page No. 42.
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – VII on Serial Page No.45.
Lumpsum price worked out by the contractor for "ROADS /PATH/HARD STANDING/CULVERT", as listed in Schedule "A" Part – VIII on Serial Page No. 47[R].
Lumpsum price worked out by the contractor for "AREA DRAINAGE", as listed in Schedule "A" Part – IX on Serial Page No. 48.
Lumpsum price worked out by the contractor for "RETAINING WALL", as listed in Schedule "A" Part – X on Serial Page No. 49.
Lumpsum price worked out by the contractor for "LIGHTENING PROTECTION", as listed in Schedule "A" Part – XI on Serial Page No. 50 [R].
Lumpsum price worked out by the contractor for "RAIN WATER HARVESTING", as listed in Schedule "A" Part – XII on Serial Page No. 51 [R].
Lumpsum price worked out by the contractor for "ARBORICULTURE", as listed in Schedule "A" Part – XIII on Serial Page No. 52[R].
Lumpsum price worked out by the contractor for "FIRE FIGHTING SYSTEM & FIRE ALARM", as listed in Schedule "A" Part – XIV on Serial Page No. 54[R].
Lumpsum price worked out by the contractor for "PVC CONDUIT", as listed in Schedule "A" Part – XV on Serial Page No. 55[R].
Lumpsum price worked out by the contractor for "DISMANTLING/DEMOLITION", as listed in Schedule "A" Part – XVI on Serial Page No. 56[R].
Schedule "A" Part - XVII: [Miscellaneous Items] [Internal Electrification, Internal Water Supply, External Water Supply, External Electrification, Roads/path /hard standing/culvert, Lightning Protection, Arboriculture, fire fighting & fire alarm, PVC conduit, Dismantling/ Demolition, DG Set, Aviation lights and Lifts]
All as per Serial Item No. 17 above but one 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
All as per Serial Item No. 17 above but one 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
All as per Serial Item No. 17 above but for one bell point controlled by one bell push.
All as per item No.17 here-in-before but controlled by two two way switch complete all as specefied and directed.
M & L point wiring complete with 1100 Volts, FRLS grade, 4.0 Sq.mm, single core, PVC Insulated, unsheathed, multistranded copper conductor cable, confirming to IS - 694 drawn through and including heavy duty PVC conduit, 20 mm dia including all accessories concealed in walls / roofs / floors / ceiling etc. and prefabricated pressed GI modular box of 0.8 mm to 1.00 mm thick and suitable size as required at site and suitable for modular brackets for fixing switches sockets, etc concealed in walls, including 1100 Volts, FRLS Grade, 4.0 Sq.mm, Single Core, PVC insulated, unsheathed, multistranded copper conductor cable as earth continuity conductor with colour coding and connecting to earth dolly for one 3/5 pin 15 Amp socket outlet point controlled by one modular switch of 15/16 Amp as directed on independent board.
S & F LED adore lamp AC 240 Volts supply, B22 type, CDS five star, 10 watts of five star rated complete all as specified as directed
S & F ceiling fan, 1200 mm sweep complete AC, single phase, 230 Volt 50 HZ, 5 star rated, connecting with flexible cable 3 core copper conductor of size 23/0.0076 of suitable length from ceiling rose to ceiling fan including all hanging arrangement complete all as specified and as directed.
S & F exhaust fan, 250 mm sweep or nearest size, plastic body (heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing and making good the distrubered surfaces etc connecting with twin core flexible cable of suitable length from ceiling rose to fan complete all as spcified and as directed.
S & F exhaust fan, 300 mm sweep or nearest size, 900 RPM plastic body (heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing and making good the distrubered surfaces etc connecting with twin core flexible cable of suitable length from ceiling rose to fan complete all as spcified and as directed.
S & F energy efficient LED tube light fitting with tube 5 watts or nearest size, 240 Volts, 50 Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient complete with mounting brackets etc., including connecting up with 1.0 Sqmm, 3core flexible copper conductor cable complete all as specified and directed.
S & F energy efficient LED tube light fitting with tube 10 watts or nearest size, 240 Volts, 50 Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient complete with mounting brackets etc., including connecting up with 1.0 Sqmm, 3core flexible copper conductor cable complete all as specified and directed.
S & F energy efficient LED tube light fitting with tube 20 watts or nearest size, 240 Volts, 50 Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient complete with mounting brackets etc., including connecting up with 1.0 Sqmm, 3core flexible copper conductor cable complete all as specified and directed.
S & F energy efficient LED security light fitting with tube 30 watts new generatiion energy saving & enviraonmental friendly long life, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre-wired with 1.0 Sqmm copper conductor cable upto connector including 1.5 metre long GI tubing light grade of 32 mm dia bend to shape for fixing on wall/ pole with suitable MS bracket nuts, bolts etc., complete all as specified and directed.
M & L for sub-main wiring with 10 sqmm nominal area four single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 10.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through suitable PVC conduit of suitable size complete all as specified and as directed. Note :(i) Four run of 10 Sqmm + one run of 10 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
M & L for sub-main wiring with 6.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 6.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC conduit of suitable size but not less than 20mm dia complete all as specified and as directed. Note :(i) Two run of 6.0 Sqmm + one run of 6.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
M & L for sub-main wiring with 2.5 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 2.5 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC conduit of suitable size but not less than 20mm dia complete all as specified and as directed. Note :(i) Two run of 2.5 Sqmm + one run of 2.5 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
S & F MCB DB, double door type, vertical, TPN 4 way, 415 Volts, 50 Hz, IP 43 protection with 200 Amps rated bus bar, including provision for fixing MCCB FP 63 Amps as incoming and outgoing circuit MCB SP/TP complete, fill empty way with blanking plates complete all as specified and as directed.
S & F MCB DB, double door single pole and neutral, 06 way sheet steel phospetised powder painted with 200 amps rated bus bar 240 Volts nautral link, IP : 43 protection, double door flush mounting type, concealed in walls complete all as specified and as directed.
S & F MCB single pole 40 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size copper lugs complete all as specified as directed
S & F MCB single pole and nuetral 6 to 32 Amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of copper lugs complete all as specified as directed
S & F MCB single pole 6 to 32 Amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of copper lugs complete all as specified as directed
S & Fsingle phase electronic energy meter, tamper proof with LED display, 240 Volts, 50 Hz AC supply, 10 to 30 Amps complete all as specified and as directed.
S & F pre fabricated meter box made out of 2 mm thick CRCA sheet duly powder coated of size (50 CM x 60 CM and required depth to accomdate meter) approx to accomadate 4 Nos single phase energy meter, front portion of the meter box to be provided with four opening to take the reading of energy meter and the four slit to be covered/ fixed with glass, necessary sunmica sheet of suitable size to provide inside meter box to fix the energy meter, with locking arrangements complete all as specified and as directed. Note: Energy meter shall be measured and paid separately.
M & L earthing complete with copper earth plate electrode 600 X 600 X 3 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 20 x 3.00 mm copper strip [Earth Lead] and GI pipe 40 mm, medium grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the Plate by means of GI bolts & nuts complete all as per electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, charcoal, common salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm angle Iron, MS funnel with 20 mm bore, medium grade GI watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
S & F wall mixer brass chromium plated, fancy type for hot and cold waters screwed down for pipe with one out going for bib complete all as specified and as directed.
S & F 20 mm dia angle stop valve, chromium plated, fancy type high pressure screwed and fixed suitable for PP-R pipe complete all as specified and as directed.
S & F 15 mm dia bib tap two way, fancy type, screwed down complete all as specified and as directed.
S & F 15 mm dia health faucet chromium plated, fancy type with steel flexible complete all as specified and as directed.
M & L for 100 mm dia ductile iron pipe spigot and socket type centrifugally cast (spun) all as per IS:8329-2000, class K9 with flexible rubber gasket push on type joint having cement mortar lining with portland slag cement as per IS 455 : 1989 bituminous coating as per Annex 'C' of IS 8329, including provision of specials, such as tee's, elbows, bends, reducers, taper pieces complete all as specified and directed.
Supply, install, testing and commissioning of centrifugal pump set with minimum ratings as 10 WHP (18 HP Approx) not less than 70 metre head, 5.1 LPS with delivery size of 80 mm bore, 4 pole, 415 Volts, 50 Hz, AC 3 phase supply, electric driven, including air valve at delivery, pressure guage along with XLPE copper cable of suitable size from starter to pumpset with cable tray and suitable PCC foundation as per manufactueres recommendations complete all as specified and directed.
S & F 100 mm dia lift type foot valve flanged ends with brass stainer, suitable flanges, nuts, bolts, gaskets complete all as specified and directed.
M & L for masonry valve chamber of size 750 X 750 X 750 mm [interanl dimensions] comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6) plastring internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type B1 couping 50 x50x6 mm angle iron 3 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer all as specified and as directed.
M & L for cutting existing steel tubing for alterations or additions necessarily done in position without taking down and inserting TEE of 100 X 100 X 100 mm for taping complete all as specified and directed.
S & F sheet metal enclosure made out of CRCA sheet 2.00 mm thick indoor type totally enclosed with front opening, hinged doors weather and water proof with necessary locking arrangements along with provision for fixing incoming and outgoing cables connections tinned to copper bus bar of 100 Amps rating with insulators suitable for three phase and four wire LT AC, 50 Hz 415 Volts with and including the following:-
Incoming: [a] MCCB , 415Volts, 63 Amps, 25 KA, TPN -01 No Outgoing: [a] MCB , 415Volts, 32 Amps, 16KA, 'C' curve, TP - 03 Nos [c] Indicating lamp for On/OFF/Trip and phase indication with control fuse/MCB - 03 Nos (Set of 3)
S & F LT feeder pillar box made out of CRCA sheet 2.00 mm thick Indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 Copper bus bar of 800 Amps rating with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V complete with powder coating, necessary internal electric connection as required and provision of the following:-
Incoming [a] ACB 4 Pole, 415 V,50 KA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 630 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 01 No. Outgoing: [a] MCCB AC 3 Phase 415 V, 50Hz, microprocessor release 4 pole, 160 Amps capactiy 25KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 05 No (for 4 blocks of 36 Qtrs=04 Nos, and spare) [b] MCCB AC 3 Phase 415 V, 50Hz, microprocessor release 4 pole 250 A capactiy 25KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 02 Nos. (for 01 for DG AMF Panel & spare) [c] Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers - 01 No. [d] LED Indicating Lamps for each phase with colour code Red, Yellow, Blue for R, Y and B Phases for each breakers - 04 sets
S & F LT feeder pillar box made out of CRCA sheet 2.00 mm thick Indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 Copper bus bar of 400 Amps rating with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V complete with powder coating, necessary internal electric connection as required and provision of the following:-
Incoming [a] MCCB AC 3 Phase 415 V, 50Hz, microprocessor release 4 pole, 250 Amps capactiy 25KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 01 No Outgoing [a] MCCB AC 3 Phase 415 V, 50 Hz, microprocessor release 4 pole 63 Amps capactiy 25 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 07 No.(lift panel of MCPO block of 36 Qtrs - 04 [Fresh water pump Panel-01,Terrace pump-01 & spare] [b] MCB AC 3 Phase 415 V, 50Hz, 4 pole 32 Amps capactiy 16 KA with adjustable type thermal and magnetic setting release - 03 Nos [for Bldg common area lighting-01, street light-01& spare] [c] Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers - 01 No. [d] LED Indicating Lamps for each phase with colour code Red, Yellow, Blue for R, Y and B Phases for each breakers - 05 sets
S & F bus bar trunking system for the complete building power supply duly insulated three phase of rating 160 Amps, 25 KA, 415 Volts aluminium conductor galvanised GI enclosure 0.8mm thick (Non painted) and lightning bus trunking with galvanised steel enclosure (0.45mm thick), non painted through service shaft including end feed unit with MCCB 160 Amps, 25 KA, 4P with rotary handle, termination links of bldg including following:-
A.Vertical rising trunking system of rating 160 Amps a) Straight length with plugin oultet - 35 mtr (Approx) b) Flange end - 01 No c) End cap - 01 No d) Brackets - 25 Nos e) Springs support - 10 Nos f) Fire barrier - Complete set as required at site g) Adpator box- Complete set as required at site h) Copper braided flexibles - Complete set as required at site j) External GI earth strip 32x6 mm - 70 RM B. Lightning trunking 63 Amps, horizontal for each floor i) 63Amps, 4P lightning trunking @ 3.0 Mtr length - 10 Nos ii) MS 63 Flexible Elbow -Complete set as required at site iii) MS 63Amps, AL RH Horizontal Elbow - Complete set as required at site iv) MS 100 centre feed unit IP 5 5 - 20 Nos v) 63Amps TAP OFF BOX W/PROVN FOR MCB - Complete set as required at site vi) End cover IP55 - 20 Nos vii) MS Sleeve IP55 - 10 Nos viii) MS Plug POINT GASKET IP55 - 10 Nos ix) SUSPENSION BRACKETS - 60 Nos C. 125 Amps Tapp off box with 63 Amps, 4P , 16 KA MCCB's - 10 Nos
S & F sheet metal enclosure, provision for fixing incoming and out going cables with bus bar for cable connection tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 Volts, 100 Amps capacity complete with powder coating, necessary internal electric connection as required and provision of the following all as specified and as directed. (For lift machine room)
Incoming: [a] MCCB , 415Volts, 63 Amps, 25 KA, TPN -01 Nos Outgoing: [a] MCB , 415Volts, 32 Amps, 16KA, 'C' curve, TP - 03 Nos [c] Indicating lamp for On/OFF/Trip and phase indication with control fuse/MCB - 03 Nos (Set of 3)
M & L for boring holes under road, pavement, hard standing by trenching technology using ultra sound technique using necessary machine including 150 mm dia HDPE pipe suitable for 0.4 mpa working pressure complete all as specified and directed.
S & F LED street light luminaire 40 Watts, comprising of epoxy powder coated, Pressure die cast aluminium housing enclosed with glass cover in frame, with suitable size of bracket of 1.5 Mtr length, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete al las specified and as directed.
S & F loop in loop out box of FRP made with IP 65 protection of thermoplatic circuit breaker boxes with metric knockouts for cable entry and exit, combiclimate Cable Glands of IP66/IP67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 KA, 'C' Curve overload and short circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands etc all as specified and directed.
S & F time switch 415 Volts, single phase, 20 Amps rated (Max) with contactor fitted in sheet metal enclosure complete all as specified and as directed.
M & L for 250 mm compacted thick WMM in three layer (each layer shall be rolled separately) with broken boulders or quarry stone or shingle or gravel as per MORTH specification, interstices filled, surface formed and rolled and consolidated to required gradient and camber with 8 to 10 tonne roller complete all as specified and directed.
S & F Storage water heater of 15 Litres capacity, 2.0 KW, 5 star rated with all safety precautions and thermostat suitable for single phase 230 Volts, including brass chromium plated Non return vavle 15 mm dia, PVC flexible connection suitable for Hot & Cold water [One each] 600 mm long with brass check nuts and union etc., complete all as specified and directed.
M & L Best quality Bermuda carpet grass by piece turfing process covering 600X600mm to this area and covering with red earth organic manure, vermi compost, polydol dust, neem cake and organic manure [Cow dung] complete all as directed by Engineer-in-Charge. Note:- [i] Supply only red soil with manure & vermi compost [As per the area of grass] shall be measured and paid seperately. However, labour element for filling and watering shall be included in the rate quoted.
Supply only approved loose soil best quality for plantation complete all as directed.
Supply only approved Vermi post compost of best quality for plantation weighing each bag of 50 KG complete all as directed.
Supply only approved manure (cow dung) of best quality for plantation complete all as directed.
Supply and plantation of crotons at hedges, including preparation of ground to required depth and filling of good earth, cow dung and watering etc., complete all as directed.
Supply and planting of Ashoka plant [height of plant not less than 45 cm] above ground level including preparation of ground upto 30 cm deep and filling soft soil, Cow dung, vermi compost and watering etc complete all as directed by Engineer-in-Charge.
Supply and planting of Royal palm tree including preparation of ground upto 30 cm deep and filling soft soil, Cow dung, vermi compost and watering etc complete all as directed by Engineer-in-Charge.
M & L for earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 25x4mm thick GI strip [earth lead] and GI pipe 50 mm, medium grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, charcoal, common salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
S & F PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables with stranded copper conductor of size 1.5 Sqmm, 2 core, 1100 Volts grade complete all as specified and as directed.
S & F single sided LED signage with built in battery back up 02 hours of single "EXIT" of colour green suitable for operation of 250 Volts, 50 Hz complete all as specified and as directed.
M & L for speaker copper cable transperent FR PVC Insulated twin core flexible of size 2 X 0.5 sqmm, 1.1 KV complete all as specified and directed.
S & F TV socket with and inclusive of prefabricated terminal box and plate for fixing TV socket complete all as specified and directed.
S & F telephone socket with and inclusive of prefabricated terminal box and plate for fixing telephone socket complete all as specified and directed.
S & F PVC insulated telephone cable one pair on existing PVC conduits concealed in wall complete all as specified and directed. Note: PVC Conduit shall be measured and paid separately.
S & F PVC insulated telephone cable four pair on existing PVC conduits concealed in wall complete all as specified and directed. Note: PVC Conduit shall be measured and paid separately.
S & F PVC conduit of CATV co-axial cables (Electrolytic grade solid annealed copper conductor, jelly filled, aluminium foiled and aluminium braided) of Model RG (foam) complete all as specified and directed. Note: (i) PVC conduit shall be measured and paid separately. Note for item no 76 to 80 :Prior to drawing telephone conduits/TV conduits, the contractor shall take necessary approval of diagram from Engr-in-Charge.
S & F PVC junction box of size 10 cm X 15 cm [Approx] rectangular type concealed to wall to accommodate PVC connector of four way for telephone cable complete all as specified and directed.
Taking down carefully submain wiring of any description complete all as specified and directed.
Taking down bulk head/ mirror fiiting/ security light fitting complete all as specified and directed.
Taking down MCB distribution board with MCB's complete all as specified and directed.
i) Insualation class - 'H‘ ii) Temparature rise Class - 'H‘ iii) Excitation : Self Excited iv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% v) Frequency regulation +/- 1% (B) Diesel Engine: - Adequate capacity of Diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under
i)Fly wheel with housing ii) Cooling system :- Moulded radiator with fan & belts iii) Cooling Water pump : - Centrifugal type belt driven iv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1 Meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer : Residual type Bellows iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. v) Lub oil System : Lubricating oil filter Lubricating oil pump vi) Air Intake System : Air intake Manifold Air cleaner dry type vii) Governor :- Electronic Governor viii) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator
ix) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel x) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or as per standard practice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display. xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine xii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling xiii) Accessories :- AVM Pads built in enclosure and for entire unit on platform. xiv) Base Frame : - Should be provided as OEM norms
(iii) The generating set battaries and control panel should be inside the enclosure. (iv) Construction Details/specification are as follows: a) Outer body :- CRCA Sheet of 1.6mm thick b) Doors :- CRCA sheet of 1.6 mm thick c) Sound Insulation :- As per OEM Norms v) The accoustic should be composite in construction and fully assembled integral unit vi) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated plat form vii) The DG Set should be provided with external Emergency stop push button viii) The enclosure should be suitably illuminated by LED Lamp fittings. ix) The noise level should be 75 dba at 1m under free field conditions. x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade E) The coated rate includes excavation, removing of soft soil and PCC, Cement Concrete foundation, filling and mass concrete type B2 (1:2:4) using 40 mm graded aggregate of size not less than 4.6 x 3.0 x 0.8 m for placing of DG Set complete all as specified and directed.
M & L earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32x6mm thick GI strip [earth lead] and GI pipe 50 mm, medium grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, charcoal, common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
S & F aviation obstruction light LED type filament-less bulb with 10 Watt bulb including all fixing arrangements complete all as specified and as directed
S & F PVC insulated armoured Cable PVC sheathed LT 1100 Volts grade with copper conductor of size 3 core 2.5 sqmm multi stranded laid in ground or fixed to wall/roof etc., with suitable clamps, spacers, bolts, nuts etc., complete all as specified and as directed.
S & F time switches 250 Volts single Phase of 20 Amps rating with contactor fitted inside sheet metal enclosure complete all as spcidied and as directed.
SCHEDULE 'A' PART-XIX PHASE -II COMPREHENSIVE MAINTENANCE OF LIFTS AFTER DEFECTS LIABILITY PERIOD OF 02 YEARS
Comprehensive maintenance of Electrically Operated 13 passenger lifts (884 Kgs) to serve G+9 upper floors all as mentioned vide SI No. 84 of Sch "A" Phase-I (four Lifts) during 1st year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 8 passenger lifts (544 Kgs) to serve G+9 upper floors all as mentioned vide SI No. 83 of Sch "A" Phase-I (four Lifts) during 1st year after expiry of defects liability period all as specified and directed
SCHEDULE 'A' PART-XX PHASE -III SECOND YEAR COMPREHENSIVE MAINTENANCE OF 13 & 8 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No.84 & 83 OF THIS BOQ AFTER COMPLETION OF FIRST YEAR COMPREHENSIVE MAINTENANCE.
Comprehensive maintenance of Electrically Operated 13 passenger lifts (884 Kgs) to serve G+9 upper floors all as mentioned vide SI No. 84 of Sch "A" Phase-I (four Lifts) second year after expiry of defects liability period and After completion of first year Comprehensive Maintenance.
Comprehensive maintenance of Electrically Operated 8 passenger lifts (544 Kgs) to serve G+9 upper floors all as mentioned vide SI No. 83 of Sch "A" Phase-I (four Lifts) second year after expiry of defects liability period and After completion of first year Comprehensive Maintenance.
SCHEDULE 'A' PART-XXI PHASE -IV THIRD YEAR COMPREHENSIVE MAINTENANCE OF 13 & 8 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No.84 & 83 OF THIS BOQ AFTER COMPLETION OF SECOND YEAR COMPREHENSIVE MAINTENANCE.
Comprehensive maintenance of Electrically Operated 13 passenger lifts (884 Kgs) to serve G+9 upper floors all as mentioned vide SI No. 84 of Sch "A" Phase-I (four Lifts) third year after expiry of defects liability period and After completion of second year Comprehensive Maintenance.
Comprehensive maintenance of Electrically Operated 8 passenger lifts (544 Kgs) to serve G+9 upper floors all as mentioned vide SI No. 83 of Sch "A" Phase-I (four Lifts) third year after expiry of defects liability period and After completion of second year Comprehensive Maintenance.
Note for SL No: 90 to 95 :- (i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of Oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above Lifts. (ii) Preventive maintenance consists of carrying out routine check by skilled personnel as specified in Particular specifications and as directed by Engineer-in-Charge and lubricating to all moving parts, topping parts, topping up of oils as per Lubrication Chart including Material and labour for all consumable and major/minor spare parts. (iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation. (iv) Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor. (v) Load testing shall be arranged by the contractor to the Lift for which repairs were carried out as and when directed by Engr -in-Charge. (vi) All maintenance works shall be carried out by well qualified tradesmen and supervisor of OEM.
KEC International Limited
DES RAJ AND SONS BUILDERS PVT LTD
SOOD ASSOCIATES PVT LTD
M/S. KASHI KANCHAN PVT. LTD.
CH.VEERARAGHAVULU CONSTRUCTION PVT LTD
K KUMAR RAJA PROJECTS P LIMITED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid