Loading…
Loading…
Tender Value
₹66.5 L
EMD Value
₹1.3 L
Closing Date
14 Jul 2026, 6:00 pm5d left
Superintending Engineer IIT Mandi Kamand
O/o Superintending Engineer, North Campus of IIT Mandi Kamand Distt. Mandi HP-175075
Construction of LPG storage facility, vegetable washing room and installation of pipeline network for messes at IIT Mandi North and South Campuses
2026_IITMD_914378_1
IIT Mandi (CW)/SE-1956/2026 -27/950-52 dated 22-06-2026
Open Tender
Civil Works
120 days
South and North Campuses of IIT Mandi
Please refer to NIT
2 documents required · 2 mandatory
₹1,180
The Registrar IIT Mandi
₹1.3 L
23 Jun 2026
23 Jun 2026
16 Jul 2026
23 Jun 2026
14 Jul 2026
23 Jun 2026
23 Jun 2026 - 14 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Civil items:
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth within all lead and lift as directed by Engineer-in-Charge:
a) All kinds of soil as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 72 | Sqm | - | - |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth within all lead ad lift as directed by Engineer-in-Charge.
a) All kinds of soil as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 86 | Cum | - | - |
| 3 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed within all lead and lift.
a) Pipes, cables etc, not exceeding 80 mm dia. as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 95 | mtr | - | - |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
a)1:3:6 (1 Cement : 3 coarse sand(zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 6 | cum | - | - |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
a)1:3:6 (1 Cement : 3 coarse sand(zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 23 | Cum | - | - |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
a) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 39 | Cum | - | - |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form work for:
a) Foundations, footings, bases for columns as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 51 | Sqm | - | - |
| 8 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling & dressing & finishing the top smooth as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 60 | Sqm | - | - |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
a) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 7 | Cum | - | - |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for :
a) Lintels, beams, plinth beams, girders, bressumers and cantilevers and slab as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 39 | Sqm | - | - |