Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹36.1 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹38.9 L+₹1.3 L (3.39%)Rejected-AOC | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹42.0 L+₹4.3 L (11.4%)Rejected-AOC | L-3 | Rejected-AOC L-3 | |
| 4 | L-4₹42.4 L+₹4.7 L (12.5%)Rejected-AOC | L-4 | Rejected-AOC L-4 |
Tender Value
Refer Docs
EMD Value
₹99,100
Closing Date
17 Jun 2023, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
MISC REPAIR TO DRAINS, SECURITY WALL, SECURITY FENCING/GATES, PAVED AREA AND ALLIED WORKS AT VARIOUS LABS AND MES OFFICE AT KWC AREA, REPAIR/MAINT INCLUDING CLEANING OF SEWAGE LINE, SEPTIC TANKS ETC IN KWC LAB, CLEANING OF WATER TANKS
2023_MES_597193_1
GE/RND-39/DLI/2023-2024
Open Tender
Civil Works
Item Rate
270 days
Delhi
Class-D, Cat-a(i)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹99,100
Yes
28 Jun 2023
20 May 2023
19 Jun 2023
20 May 2023
17 Jun 2023
5 Jun 2023
Amount
Dismantling wrought iron or mild steel work of any description not otherwise provided for work including doors, gates, angle post etc complete all as specified and directed.
S&F framed work as in mild Steel Gate of angle or other section with gusset plate, rails, braces, stair case, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks, cover grills and similar work etc Fe.290.Gde-E-165 complete drilled for fixing of steel sheeting or other covering including welding work, etc to be prepared for hanging or sliding with and including either hooks, hinges, necessary holdfasts or steel hanging door fittings, locking arrangement, gate closer, stopper etc and hanging also fastening and fixing in building upto 8 mtr height including necessary PCC 1:2:4 type B-1, 20mm graded stone aggregate complete all as specified and directed.
S&F mild steel work as in joist channels, angle or tee section, fixed independently with out connecting plate conforming to Fe.290.Gde-E-165, incl cutting tops to shape as directed, drilling holes,notching for wire, welding work etc flat iron fillets including all necessary drilling, bolting or riveting, etc posts and struts in fencing including cutting top to shape drilled and countersunk for balusters running bars, nosing to steps including embeding in concrete and screwing etc wind ties for roof including securing bolts, and similar work including necessary cutting, drilling, welding etc complete all as specified and directed.
S&F in repairs Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
Restraining and rescecuring Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc as directed (each line wire to be measured) complete all as specified and directed.
S&F in repair of concertina coil fencing with punched tape, 600mm dia, having 50 Nos rounds per 6m length, laid on ground or fixing the same on Y-shaped angle iron with necessary G.I staples/GI clips to retain in horizontal position including necessary bolts, fasteners and binding wire complete all as specified and directed.
S&F in repairs of concertina coil fencing with punched tape, 450mm dia, having 50 Nos rounds per 6m length, laid on ground or fixing the same on Y-shaped angle iron with necessary G.I staples/GI clips to retain in horizontal position including necessary bolts, fasteners and binding wire complete all as specified and directed.
Dismantling timber scantlings 40 Sqcm and over in section, in any position as in framed work complete all as specified and directed.
Dismantling timber scantlings 40 Sqcm and over in section, in any position as in unframed work complete all as specified and directed.
Excavation in post holes (or similar holes) in soft/loose soil not exceeding 0.50 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm, watering and removing surplus soil complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling, mass concrete etc complete all as specified and directed.
S&F structural steel work in tubular trusses, posts, purlins, rafters, framed work in truss etc including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 complete all as specified and directed.
Dismantling of asbestos cement (corrugated semicorrugated etc) sheets in roof covering complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering, cladding to wall, ridges etc fixed all as per manufactures's instructions and fixed with self thread making steel screws of length not less than 50mm complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges, flashing, eaves board valley gutter of any shape etc cut to designed shape (Jhhallar) as directed at site fixed all as per manufactures's instructions and fixed with self thread making steel screws of length not less than 50mm complete all as specified and directed.
M&L for Preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, fixed complete all as specified and directed.
M&L for preparation of old painted steel or iron surfaces of any description over 10cm width or girth and applying one coat of synthetic enamal paint of tint as approved complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15 cm thick below or above ground level complete all as specified and directed.
M&L 100 mm thick cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub floors, filling and mass concrete etc complete all as specified and directed.
S&F factory made chequred cement concrete coloured tiles 200mm x 200mm x 25mm thick, set jointed and pointed in neat cement slurry with grey cement mixed with pigment to match the colour of tiles, laid over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons laid dry or in any type of mortar complete all as specified and directed.
M&L for machine made rubber moulded precast concrete interlocking paver block (coloured), pre polished of any shape and size with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness M-35 Grade, over and including 25mm average thickness sand cushioning complete all as specified and directed.
M&L for machine cut Kota Stone slab as in flooring/landing of stairs , 18-20mm thick, laid and jointed with grey cement slurry mixed with pigments to match the shade of the slab and including rubbing and polishing laid over 20mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for Granite 16 to 18 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking plateforms and like in CM 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite including 20mm thick screed bed or bedding lay in CM 1:6 complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (12.5mm graded aggregate) as in plinth courses, copings, parapets, saucers drain, kneelers, apex stones, bed blocks, kerbs, water troughs including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with CM 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed.
M&L preparing newly concrete surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
M&L preparing old painted concrete surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc complete all as specified and directed.
M&L for brick work with Sub class ‘B’ bricks old size straight or curved on plan exceeding 6m mean radius in CM 1:4 for manholes, footpaths, compound wall, pillars etc complete all as specified and directed.
Taking down cement plaster, pointing, on brick or stone/concrete walls, drain surfaces etc including racking out joints, hacking for key, scrubing down with water etc in any position complete all as specified and directed.
M&L for 15 mm thick rendering on brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering on brick work or concrete surfaces in CM 1:4 mixed with WPC as per manufactures instructions finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound etc complete all as specified and directed.
M&L for 15 mm thick rendering on brick work or concrete surfaces in CM 1:6 finished even and fair without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surface of walls and applying two coats of oil emulsion distemper over a coat of 2mm thick wall care putty in two layers (each layer minimum 1mm thick) complete all as specified and directed.
M&L for preparation of new plastered wall surfaces and applying two coats of acrylic exterior emulsion paint superior quality over and including a coat of water based primer (tint and pattern as approved by GE) complete all as specified and directed.
M&L for complete removal of existing treatment including preparation of plastered or unplastered old decorated surfaces of walls including pillasters and cornices etc including washing, rubbing down and stopping the previously treated surface and applying two coat of acrylic exterior emulsion paint superior quality over and including a coat of water based primer (tint and pattern as approved by GE) complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
M&L RCC type B-1, 1:2:4 (20mm graded stone aggregate) for slabs supports on walls complete all as specified and directed.
M&L for TMT bars of 10mm dia and over, cut to lenghth bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire not less than 0.9mm dia or securing with clips complete all as specified and directed.
Use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick surface flat for rough finished surface of concrete complete all as specified and directed.
Use & waste of form work to to edge of concrete flats etc exceeding 10 cm but not exceeding 20 cm wide/thick for fair finished surface of concrete complete all as specified and directed.
M&L for providing precast cover slab in PCC 1:2:4 type B1 (20mm using graded stone aggregate) for drains with perforated hole as per the direction complete all as specified and directed.
M&L for Precast RCC work (Nominal Mix) 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in slabs supported on walls, man hole cover, drain covers, Shelves etc and like complete all as specified and directed.
Repair to rolling shutter push type with necessary repair work of defective parts i.e, re-posting of laths, riveting to old defective rivets, tightning nuts and bolts, replacement of spring, greasing to movable parts and at guide channel including taking out and re-fixing rolling shutter for smooth functioning size of rolling shutter not exceeding 6 Sqm each complete all as specified and directed.
S&F in repairs mild steel plain sheets covering to door shutter and top cover of rolling shutter cover cut to size, edges beaded as directed, holes punched complete all as specified and directed.
M&L for preparation of old painted steel or iron surfaces as in railing, rolling shutters etc of any description over 10cm width or girth and applying two coat of synthetic enamel paint of tint as approved complete all as specified and directed.
Removing Debris/Demolished materials by mechanical means including loading, transporting, unloading to outside MoD land from 5KM upto 20KM lead at municipal dumping ground complete all as specified and directed.
Desilting of septic tank any size including cleaning and taking out mud/sludge, scum, silt (both organic and inorganic nature) from septic tanks by mechanical means of any depth, in foul conditions and confined places, getting out and removing the Sludge/Sludge water disposed off in closed container at authorized dumping site declared by local administration outside MoD land and sprinkling line to the affected area complete all as specified and directed. Note:- Net contents of sludge shall be measured at the time of removal and paid. Quoted rate of tenderer is deemed to be inclusive of dewatering as required and nothing extra shall be admissible to the contractor on this account.
Maintenance of sewage system SGSW/PVC(SWR)/NP2 pipe including Nahani/floor traps, soil/waste pipe running on external wall of building and in trenches with fittings, bends, junctions etc, Gully traps, manholes of all description and sewage lines of all sizes upto soak well/MCD drain of sewage system complete in perfect running / flowing order without destruction by removing all blockage in the system including cleaning the floor trap, gully trap, IWC, EWC Wash basin, Urinal pots, bottle trap, in kitchen, lobby, bath room, toilets at any height of floor (Maximum G+7 Floor) including pipe line up to the first manhole including maintaining of drain (Bricks / PCC) in running condition by removing all surplus spoil in entire KWC lab area (inside and outside area of all DRDO labs in KWC area) under GE (I) R&D delhi, complete all as specified and directed. Notes:- (i) Contractor shall deploy minimum 2 safaiwala solely for the maintenance of sewage system against this item alongwith necessary tools and will be required to report AGE B/R office KWC area to collect the complaint slip from concrened JE on normal working hours from 0900 hrs to 1700 hrs on all working days but on demand for Sundays, Holidays, additional working hours also, contractor shall provide the same to meet the requirements. These Safaiwala / Mazdoor shall not be deployed for any works other than the scope catered for in this item. For the work considered against other items of this Schedule the contractor shall deploy separate sfafiwala / mazdoor in addition to the safaiwala /mazdoor deployed against this item. (ii) Rate also includes for necesary tools and plants which is required for execution of item i.e cleaning rod, buckets, bamboos sticks, Kashi etc (iii) Sludge slurry / sludge water shall be disposed off in closed container at authorized dumping site declared by local administration outside MD land. (iv). Solid waste / sludge / silt deposited in the manholes which can not be removed by rodding, shall be ordered under respective item of this schedule and paid accordingly.
Dewatering of Soakage Well cleaning and taking out effluent water from soakage well by mechanical means of any depth, in foul conditions and confined places, getting out and removing the effulent water and disposed off in closed container (tank capacity 5000 litres each) at authorized dumping site declared by local administration outside MoD land complete all as specified and directed. Note :- Each tank capacity of 5000 litres shall be measured as one Job.
M&L cleaning & clearing manholes by taking off manhole covers and re-fixing the same after cleaning of any description, underground any depth by removing any type of blockage including de-silting and de-chocking and flushing after cleaning, clearing of manholes. Sludge/ sludge water shall be disposed off in closed container at authorized dumping site declared by local administration outside MoD land, upto 150mm dia sewage lines complete all as specified and directed.
Removal of blockage in between two manholes spacing upto 18 meters between manholes of underground sewage line of any type and size upto 200 mm dia by means of mechnical rodding with vibrations/drilling concept. A trolley mounted motorized sewer cleaning machine for the execution of item shall have to be provided by the contractor. Blocked material, slugging obtained during execution of this item shall be removed from the site through trolly mounted motor out of defence land. Sewage line between existing two manholes shall be flushed with combined high pressure water jetting cum suction (vaccum type machine suitably mounted on HCV having facilities of hydraulic applications with suitable size of nozzle pipes upto the desired satisfaction including sprinkling lime to the affected area complete all as specified and directed.
Cutting of bushes not exceeding 10cm girth and removng of unserviceable material to a distance not exceeding 50 m and cleaning site complete all as specified and directed.
S&F factory made precast heavy duty drain/ manhole covers including MS frame and including reinforcement as per IS 12592 : 2002 with specified thickness complete all as specified and directed.
S&F factory made prepolished chequred cement concrete coloured tiles 300mm x 300mm x 25mm thick, set jointed and pointed in neat cement slurry with grey cement mixed with pigment to match the colour of tiles, laid over and including 20mm thick screed bed in CM 1:4, complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in benching for manholes and haunching around manholes frame for setting, coping, holdfast fixing etc including use of necessary form work and finishing exposed surfaces even and smooth using extra cement complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces and applying two coats of cement base paint complete all as specified and directed.
Excavation as in trenches in hard/dense soil not exceeding 1.5 metres wide and not exceeding 1.5 metres deep lines and getting out complete all as specified and directed.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil complete all as specified and directed.
Disposal of building rubbish/malba/similar unserviceable, dismantled or waste materials by mechanical means including loading, transporting, unloading to outside MoD land from 5 KM upto 20 KM lead at municipal dumping ground complete all as specified and directed.
M&L in repair 150mm dia Salt glazed stoneware drain pipes laid in trenches and jointed with cement mortar 1:1 and spun yarn soaked in neat cement slurry complete all as specified and directed.
All as per item Ser No 63.00 above but 300mm dia.
S&F in repair PVC (SWR) 150mm dia pipe single socketed, in any length with rubber ring joints, laid in trenches or in floors pipe complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) as in bed to drain/ sewage pipe including packing under and haunching against the sides of pipes of 150 mm internal dia after they are laid and tested complete all as specified and directed.
S&F in repair 75 mm internal dia PVC (SWR) pipes single socketed in any length with rubber joint, laid in trenches or in floors complete all as specified and directed.
Cutting into existing manhole for connecting into new drain, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section), in cement concrete 1:2:4, type B-1, using 20mm graded stone aggregate, smooth finished and reforming benching as required for 150 mm bore SGSW / RCC pipe complete all as specified and directed.
S&F in repair 110mm internal dia PVC (SWR) pipes single socketed in any length with rubbering joint fixed to wall with MS clamps complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius 110 mm dia including taking down complete all as specified and directed.
S&F in repiar 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed.
S&F in repair 110mm dia PVC (SWR) vent cowl, single, equal or un equal of any length including jointing with solvent cement as required complete all as specified and directed.
Cleaning of roofs i.e. removal of vegetables, roots, removal of blockage from mouth of rain water pipes and rubbish off from premises, brooming etc up to seven stories buildings complete all as specified and directed.
S&F in repair vitreous china squatting pan, orissa pattern size 580mm x 440mm white with integral foot rests (excluding flushing cistern and flush pipe) complete including provision of lime concrete bedding complete all as specified and directed.
S&F in repairs vitreous china wash down water closet pedstal pattern white including PVC seat cover with aluminium hinging devices & EWC Jet brass chromium plated with and including 1.00 mtr long PVC connection pipe and PVC valveless syphonic action type flushing cistern low level 10 litres capacity, white, with inlet, ball valve, float and handle including brackets etc complete all as specified and directed.
Desilting and cleaning of open drains of any section manually including desilting soild/semi solid materials of any type vegetation growth and removal of sludge upto a distance exc 5.00 KM from the edges of drains etc complete all as specified and directed.
Cleaning and removing all scale and dirt, etc, from water tanks, capacity exceeding 250 litre but not exceeding 500 litre and from mouths of circulating pipes etc by disconnecting, setting side if required emptying, drying, cleaning by scrubbing the dust with wire brush from tank by removing inlet and outlet pipe and refixing inlet and outlet pipe with new tank connection fitting and float valve and tank in the same position after cleaning complete all as specified and directed.
Cleaning and removing all scale and dirt, etc, from water tanks, capacity exceeding 500 litre but not exceeding 1000 litre and from mouths of circulating pipes etc by emptying, drying, cleaning by scrubbing the dust with wire brush from tank by removing inlet and outlet pipe and refixing inlet and outlet pipe with new tank connection fitting in the same position after cleaning complete all as specified and directed.
S&F in repair Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed for 15 mm bore pipe, complete all as specified and directed.
S&F as in repair Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed for 20 mm bore pipe, complete all as specified and directed.
Taking up or down 15 mm dia steel tubing and connection and removal from site complete all as specified and directed.
Taking up or down 20 mm dia steel tubing and connection and removal from site complete all as specified and directed.
Taking up or down 25 mm dia steel tubing and connection and removal from site complete all as specified and directed.
S&F 15mm bore tubes "medium grade" galvanized with and including all fittings complete to walls and ceiling or laid in floors complete all as specified and directed.
S&F 20mm bore tubes "medium grade" galvanized with and including all fittings complete to walls and ceiling or laid in floors complete all as specified and directed.
S&F 25mm bore tubes "medium grade" galvanized with and including all fittings complete to walls and ceiling or laid in floors complete all as specified and directed.
S&F in repairs Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both ends for iron pipe and fixed, screwed down, high pressure screwed ends for iron pipe or for unions and fixed complete all as specified and directed.
Dismantling water tanks and removing from site of 500 litres capacity complete all as specified and directed.
Dismantling water tanks and removing from site of 1000 litres capacity complete all as specified and directed.
S&F 500 litres capacity rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S&F 1000 litres capacity Rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S&F in repairs PVC lid/cover for PVC water tank of 500/1000 litre capacity complete all as specified and directed. Make :- Sintex/ Polycon/Sheetal
S&F grating droom of size 100/125/140 mm brass chromium plated in round or square shape for out let of water etc complete all as specified and directed.
S&F in repair PVC waste pipe 32mm/40mm dia for WHB/Sink etc fixed complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortor bedding (but not backing), removing rubbish off the premises complete all as specified and directed.
M&L for 1st quality non-skid coloured ceramic tiles 7 to 8 mm thick, area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor set & jointed in neat cement slurry and pointed in coloured cement to match the shade of coloured tiles laid over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L 1st quality glazed coloured ceramic tiles 300x200x7mm thick in vertical surfaces such as dado, skirting, riser etc set and jointed in neat cement slurry and pointed in white or coloured cement to match as in over 10mm thick rendering in CM 1:4 complete all as specified and directed.
M&L fully vitrified tiles light shade 9 to 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.16 Sqm but not exceeding 0.36 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as specified and directed.
S&F framed work conforming to Fe-290 Gde E-165 as in door, grill railing, cattle trap/drain covers on open drains using mild steel angle iron, MS flats of sizes as directed with and including provision of MS hings and MS Hold fast fixed complete all as specified and directed.
M&L for complete removal of the existing treatment of walls and applying two coats of oil emulsion distemper over 2mm thick wall care putty in two layers (each layer minimum 1mm thick) complete all as specified and directed.
M&L Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed.
M&L bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates, hook and pintle hinges: large hasps and staples, chains;hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
Cutting chases, pining in making good to facings where required & pointing in CM 1:3 to ends etc or edges of landings, steps cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing and making good, cutting not exceeding 10cm girth in brick walls complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in roofs including any type of roof treatment, mud phuska, PCC padding,lime concrete etc up to any thickness and Clean up to existing RCC roof by steel wire brushes and surface washed with clean water and complete all as specified and directed. Note:- All Demolished material/debries will be taken by the contractor out side of the air force station Bikaner without any extra cost to the govt contractor should quote his rate keeping this aspect in mind.
Cutting grooves in brick wall, for inserting APP membrane and other works 75mm wide and 65mm deep and shaping horizontal face of grooves and making good with CM 1:3 or PCC 1:2:4 complete all as specified and directed.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hotmixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed.
M&L PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in mass concrete over roof as in padding incl cement slurry over old RCC surface, surface fair finished even & smooth without using extra cement complete all as specified and directed.
M&L15 mm thick plaster in CM 1:4 over concrete surfaces of roofs finished even and smooth with WPC @ 3% by weight of cement (WPC will be measured and paid seperately) complete all as specified and directed.
M&L for APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/Sqm ) laid on and including primed surfaces of btuminious primer of hot applied industrial bitumen 85/25 at the rate of 1.2 kg per Sqm, by torch forced application complete all as specified and directed.
M&L for 20 to 22 mm thick precast cement concrete tiles type B-1, 1:2:4 (10mm to 12.5mm graded stone aggregate) slab flooring, bedded over 15 mm thick screed bed in CM 1:4 ,and jointed in CM 1:4 and pointed in CM 1:3. complete all as specified and directed.
M&L for repairing of soffit and sides of RCC slab/chajja and similar works by dismantling of loose/ disintegrated portion of RCC at any height and in any situation (including provn of support, formwork and welding of reinforcement with weld mesh of weight not less than 3 kg/ sqm and dubbing 1st coat of 20 to 25mm thick in cm 1:3 finished rough and finishing coat of 10mm thick in CM 1:3 finished even and smooth without using extra cement after applying cement slurry @ 3.00 Kg/Sqm and applying two coats of white wash complete all as specified and directed. Note :- (i) Unit rate of this items includes the cost of scaffolding, form work, necessary water proffing agent etc and nothing extra shall be paid on account of variation if heights. (ii) The measurement of finished plaster of 2nd coat provided on surface in sqm shall be the mode of measurement aganst this item.
M&L for repairing of RCC projection, chajjas, facia, bands, shelves, beams, RCC railing, balcony and similar works by dismantling of loose/ disintegrated portion of RCC at any height and in any sitution / floor (including provn of support, formwork and welding of reinforcement if required with wire mesh of weight 3 kg/ sqm and dubbing/ filling with PCC (1:2:4), type B-0, using 12.5 mm graded aggregate,15 to 25 mm thick after applying cement slurry @ 3 kg/sqm, finished even and smooth to desired shape and applying two coats of wheater proof emulsion paint to match with existing surfaces complete all as specified and directed.
S&F in repair long body Bib taps,chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, suitable for 15mm bore pipe complete all as specified and directed.
S&F in repair angle valve, chromium plated,screwed down, high pressure with crutch or butterfly handle screwed for iron pipe or for union, suitable for 15mm bore pipe, fixed as in repair complete all as specified and directed.
S&F in repair Premium Carpet flooring with 14mm thick sound proof Polyester fiber Carpet having NRC value not less than 0.35 and backing of Action Back PP with cut pile structure having pile weight of 1500GSM and total weight of 2000 GSM complete fixing of carpet on floor with suitable adhesive as per maufacturer instruction including shifting out furniture for flooring and reshifting of furniture after carpet flooring including making all suitable arrangements for the same complete all as specified and directed. Note:- Work to be executed by OEM, contractor shall qoute his rate keeping this aspect in mind. Make:- Himalyan Acoustics or equivalent as approved by GE.
S&F in repair Gun-metal, globe or gate valve 15mm bore, with iron wheel head, screwd both ends for iron pipe and fixed, screwed down, high pressure screwed ends for iron pipe or for unions and fixed complete all as specified and directed.
M&L for complete removal of exisitng treatment on wall surfaces with sand paper, iron patti or grinder, including pillasters and cornices etc and applying two coat of interior acylic emulsion paint over a coat of 1mm thick birla wall care putty to achieve smooth finish complete all as specified and directed.
M&L complete removal of existing treatment on ceiling surfaces with sand paper, iron patti or grinder, including pillasters and cornices etc by brooming down with steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying two coat of white wash complete all as specified and directed.
M&L preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint tint/shade as approved complete all as specified and directed.
M&L preparation of old painted steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of tint as approved complete all as specified and directed.
Supply and laying of CPVC pipes having outer dia 20mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches including taking down of old pipes/tubing complete all as specified and directed.
Supply and laying of CPVC pipes having outer dia 25mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches including taking down of old pipes/tubing complete all as specified and directed.
SAWARIYA ENGINEERS AND CONTRACTORS
DP COMPLEX
Sree Ram Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .