Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC PARUTHIYEZHATHU HOUSE MULAVUKAD P O NORTH ERNAKULAM 682 504 | ERNAKULAM | KERALA | 682504 | L1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | L2₹10.9 L+₹39,083 (3.73%)Rejected-Finance 39 359 B PULICKAL THIRUVAMBADY POST ALAPPUZHA KERALA PIN 688 002 | ALAPPUZHA | ALAPPUZHA | KERALA | 688002 | L2 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 3 | L3₹13.8 L+₹3.3 L (31.8%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST TENDERER |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
14 Aug 2023, 6:00 pmClosed
GE Fort Kochi
GE Fort Kochi -682001
REPAIR/MAINT OF INTERNAL ELECTRIC SUPPLY INCL REPAIR/REPLACEMENT OF UNSERVICEABLE LIGHT FITTINGS, WIRING, BLDG SECURITY LIGHTS, SWITCHES, DBS,MCBS AT MD ACCN IN INS DRONACHAYA and MES COLONY AT FORT KOCHI
2023_MES_606816_1
8920/GE_Fort_Kochi
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Fort Kochi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Fort Kochi
₹30,000
Yes
5 Sept 2023
29 Jun 2023
16 Aug 2023
29 Jun 2023
14 Aug 2023
29 Jul 2023
Amount
Taking up carefully defective switch /socket /regulator/bell/bell push/holder etc any size complete all as specified and as directed.
Supply and fix switch piano, flush type, single pole, one way, 5 Amps, complete all as specified.
Supply and fix switch piano, flush type, single pole, two way, 6 Amps, complete all as specified.
Supply and fix switch socket combination outlet multipurpose 2 in 1, 5 pin, 6 Amps and 2 pin 6 Amps flush type complete all as specified.
Supply and fix switch socket combination outlet multipurpose , 6 Amps and 16 Amps flush type complete all as specified.
Supply and fix socket outlet multipurpose 2 in 1,3 pin, 5 Amps and 2 pin 5 Amps complete all as specified.
Supply and fix socket outlet multipurpose 5 Amps and 16 Amps complete all as specified.
Supply and fix switch piano, flush type, single pole, one way, 16 Amps, complete all as specified.
Supply and fix electronic Fan regulator stepped type flush type suitable for existing ceiling fans fixed on phenolic laminated sheet etc. as reqd complete all as specified.
Supply and fix ceiling rose PVC poly carbonate, isolated body with two to three terminals including connection complete all as specified.
Supply and fix lamp holder, PVC / Poly carbonate type,with cord grip cap suitable for pendent/batten/angle fittings complete all as specified.
Supply and fix Bell push, flush type, 5 Amps complete all as specified
Supply and fix bell Ding Dong AC. 230 volts, single pole complete all as specified.
Supply and fix Modular switch 1 way 6A,1 module complete all as specified
Supply and fix Modular switch 1 way 16A,1 module complete all as specified
Supply and fix Modular Bell push 6A 1 module complete all as specified
Supply and fix modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified
Supply and fix modular Socket 6A/16A - 2/3 pin combined 2 module,, complete all as specified
Supply and fix MCB SP 6 to 32 Amps, 240 Volt, having breaking capacity 10 kA, B curve with visual indication complete all as specified.
Supply and fix MCB SPN, 32 Amps, 240 Volt, having breaking capacity 10 kA, C curve complete all as specified.
Supply and fix MCB SPN, 40 to 63 Amps, 240 Volt, having breaking capacity 10 kA, C curve complete all as specified.
Supply and fix MCB TPN, 40 to 100 Amps, 415 Volt, having breaking capacity 10 KA, C curve complete all as specified.
Supply and fix RCCB 25 Amps 30 mA sensitivity short circuit current rating 6 KA double pole , complete all as specified.
Supply and fix Recess mounted type aesthetic look LED downlight fittings 15 W suitable for modern workplace all as specified and as directed Make : Havells/Crompton/Philips or equivalent in Appendix 'C'
Supply and fix surface mounted LED batten four feet long, 22 Watt comprises of polycarbonate housing, integrated electronic driver, diffuser etc and all accessories pre-wired including connecting up complete all as directed. Make Havells/Crompton/Phillips or equivalent in Appendix 'C'
Supply and fix surface mounted LED batten 2 feet, 10 Watt comprises of polycarbonate housing, integrated electronic driver, diffuser etc and all accessories pre-wired including connecting up complete all as directed. Make Havells/Crompton/Phillips or equivalent in Appendix 'C'
Supply and fix LED lamp B22 10 watts suitable for existing angle/batten holder comprises of high pressure die cast aluminium housing, polycarbonate cover, etc complete all as directed. Make Havells/Crompton/Phillips or equivalent in Appendix 'C'
Supply and fix Decorative wall light fixture made up of Polycarbonate comprises of high efficiency diffuser and all accessories pre-wired including connecting up incl 1x9 watt LED lamp complete all as directed. Make Havells City 3 or equivalent from Crompton/ Phillips or equivalent in Appendix 'C'
Supply and fix LED building security light fitting 25 watts protection comprises of a pressure die cast aluminium housing, polycarbonate cover, high power LED with lenses, 10KV built-in-surge protection, electronic driver, etc and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 Sq mm, 3 core as required for connections complete all as directed.
Supply and fix post top lantern LED type 25 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified.
Supply and fix LED bulk head luminaries, with lamp holders and 1x 9 watt LED lamp etc complete with all accessories and including connecting up with twin core copper conductor cable with suitable size of 230 V, 50 Hz complete all as specified and directed. Make Havells /Bajaj/wipro or equivalent in Appendix 'C'
S&F in repair PVC round sheathed (flexible) industrial copper cable of size 1.5 Sqmm incl 20 mm PVC conduit all as specified and as directed
S&F in repairs 3 mm thick ISI marked laminated sheet cover and brass screw with cup washers for fixing switches/sockets/regulators etc cut to suitable size, cutting holes for fixing switches, regulators, sockeets etc including taking down of old sheet complete all as specified.
S&F in repair MCB DB double door made of sheet steel phosphates, powder painted with bus bar, neutral link, earth bar and rail double door type TPN 415 volts 4 way fixed concealed /recessed having IP-43 protection including cement mortar 1:3 for making good to distrubed surface match with existing surface incl colouring complete all as specified
-ditto- all as per item No.34 here in before but TPN 8 way
-ditto- all as per item No.34 here in before but TPN 12 way
-ditto- all as per item No.34 here in before 240 Volts SPN 8 way
-ditto- all as per item No.34 here in before 240 Volts SPN 12 way
-ditto- all as per item No.34 here in before 240 Volts SPN 4 way
S&F in repair sheet metal enclosure with two pin and earth plug and socket complete with one MCB 20 Amps single pole having breaking capacity 10 kA complete all as specified.
M&L in repairs for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried directgly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the plate not less than 1..5 mtr normal ground level, connected to GI strip 32x6mm size as earth lead by means of bolts, nuts , check nuts and washers of GI or steel as shown in electrical plate No 3 connected to earthing test point, testing, (Earthing shall be interconnected) including necessary excavation,50mm thick RCC 1:2:4 cover reinforced with 8mm TMT bars 100 mm c/c in both ways at , salt, charcoal, removal of surplus soil etc including taking out old earth plate complete all as specified.
M&L for inspecting all DBs including tightening of screws, MCBs ,any other loose parts ,replacing burnt wires , wraping all joints with insulation tape and registering details all as specified and as directed.
M&L for checking & cleaning of all switch boards/ ceiling rose in each qtrs/working place including tightening of any loose parts ,replacing burnt wires, wraping all joints with insulation tape & arranging hanging loose wires properly and registering details all as specified and as directed
M&L for pouring of salted water in to each earth pit through water pipe , minimum of 100 Ltrs dissolved with 5 Kgs of common salt to each earth pits / electrodes at various sub staions / buildings for improving the earth conditions , all as specified and as directed. Note :- . The contractor has to arrange water and transport to various sub stations / installations for the above purpose and Testing of Earth resistance of Electrical earthings of various types , at various Buildings / sub stations by using digital type Electrical earth Tester instruments , registering the test results in the prescribed proforma including cleaning the earth chamber , identifying the earth lead wire , testing and writing by paint the test reults, date of testing etc. on the chambers all as specified and as directed . The job/test will be carried out in the presence of department staff and deatils registered all as specified and as directed.
S&F in repair 25 mm size ISI marked PVC casing capping including all fittings and fixing accessories complete all as specified and as directed.
S&F in repair 32 mm size ISI marked PVC casing capping including all fittings and fixing accessories complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket etc) complete, incl fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, lamp holder etc,refixing removed fittings and making good the disturbed surface of wall to match with existing surface complete all as specified.
Taking down submain wiring of any type complete all as specified.
Taking down DB of any size complete all as specified.
M&L for point wiring surface type with single core 1.5 Sqmm PVC insulated unsheathed single core multistranded copper conductor cable (FRLS) including 1.5 Sqmm PVC insulated unsheathed copper conductor as earth continuity conductor drawn in and including ISI marked PVC casing caping not less than 25 mm width with its accessories, and fixed in existing sunk boxes and covered with new 3.00 mm thick ISI marked laminated sheet cover and brass screw with cup washers for fixing switches/sockets/regulators etc.
One light point controlled by one switch.
One Exhaust Fan controlled by one switch
One fan point by one switch and regulator
One wall mounted controlled by one switch
One bell/buzzer point controlled by one push button on the same board
One light point controlled by two 2-way switches
One 5 Amps socket outlet point on same board alongwith other switch.
One 5 Amps socket outlet point on independent board controlled by one switch.
-Ditto- all as per srl item No 50 here-in-before but with cable 4.0 sqmm including 4.0 sqmm cable as earth wire for 15/16 amp socket.
M&L for point wiring in existing conduit/PVC casing caping concealed or surface type with PVC insulated, unsheathed, single core multistandard copper conductor cable (FRLS) of size 1.5 Sqmm, 1100 volts grade including 1.5 Sqmm PVC insulated, unsheathed, copper conductor cable for earth continuity wire to be drawn through existing PVC conduit/casing caping and fixed in existing sunk boxes and covered with new 3.0mm thick ISI marked laminated sheet cover and brass screw with cup washers for switches/sockets/regulators etc.
One light point controlled by one switch.
One Exhaust Fan controlled by one switch
One fan point by one switch and regulator
One wall mounted controlled by one switch
One bell/buzzer point controlled by one push button on the same board
One light point controlled by two 2-way switches
One 5 Amps socket outlet point on same board alongwith other switch.
One 5 Amps socket outlet point on independent board controlled by one switch.
-Ditto- all as per srl item No 52 here-in-before but with cable 4.0 sqmm including 4.0 sqmm cable as earth wire for 15/16 amp socket.
M&L for sub main wiring surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run of 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked PVC casing caping with all necessary accessories such as bends, tees,elbows etc complete all as specified and as directed. (Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire and one run of PVC casing caping with all necessary accessories will be measured as one length).
M&L for sub main wiring surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run of 6 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked PVC casing caping with all necessary accessories such as bends, tees,elbows etc complete all as specified and as directed. (Note :- Two runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC casing caping with all necessary accessories will be measured as one length).
M&L for sub main wiring concealed type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run of 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked PVC rigid conduit with all necessary accessories such as bends,junction boxes, tees,elbows etc complete all as specified and as directed. (Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
M&L for sub main wiring concealed type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run of 6 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked PVC rigid conduit with all necessary accessories such as bends,junction boxes, tees,elbows etc complete all as specified and as directed. (Note :- Two runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
M&L for sub main wiring in existing surface/recessed steel/PVC conduit/casing caping with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run of 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity complete all as specified and as directed. (Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire will be measured as one length).
M&L for sub main wiring in existing surface/recessed steel/PVC conduit/casing caping with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run of 6 Sqmm PVC insulated multi stranded copper conductor for earth continuity complete all as specified and as directed. (Note :- Two runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire will be measured as one length).
Supply and laying or fixing or passing through pipe or cable duct from meter room to the various floors of multistorey building, upto eight floor/10th floor,1100 volt grade heavy duty cable with XLPE insulated aluminium conductor with an inner sheathing of PVC tape armoured with galvanaized steel or tape and over all PVC sheathed 16 sqmm 4core wire incl taking up/down old cable complete all as specified.
S&F PVC rectangular block for mounting, switches, sockets, fan regulators etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 150 mm x 50 mm deep all as specified & directed.
S&F PVC rectangular block for mounting, switches, sockets, fan regulators etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm x 50 mm deep all as specified & directed.
St George Engineering Works
ST ANTONY CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .