Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.7 LAccepted-AOC 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹20.9 L+₹23,345 (1.13%)Rejected-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹24.7 L+₹4.0 L (19.5%)Rejected-AOC HQ CWE AHMEDABAD | GANDHINAGAR | GUJARAT | 382006 | L3 | Rejected-AOC REJECTED |
Tender Value
₹21.5 L
EMD Value
₹43,000
Closing Date
17 Jun 2020, 6:00 pmClosed
GE I CG Porbandar
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
PROVISION OF STORAGE ACCOMODATION FOR SRMO AND SHED FOR GENERATOR AT CG JETTY AND PROVN OF PARKING SHED FOR MI ROOM AND SHOPPING COMPLEX AT CG DHQ NO 01 PORBANDAR UNDER GE (I) CG PORBANDAR
2020_MES_319826_3
8469
Open Tender
Civil Works
Item Rate
240 days
GE I CG Porbandar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I CG Porbandar
₹43,000
Yes
29 Jul 2020
30 May 2020
18 Jun 2020
30 May 2020
17 Jun 2020
3 Jun 2020
Amount
SCHEDULE 'A'
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out soft / disintegrated rock all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick using excavated material all as specified.
Excavation in post hole each n.exc 0.50 Cum getting out, returrning filling in and ramming earth or broken ruble mixed with earth around, in layer n.exc 25 cm, watering and removing surplus soil to a distance n.exc 50m and making good surfaces in soft/loose soil all as specified
M&L Sand cushioning in trenches, ducts for electric cables, for protection incl. compaction all as specified and as directed by engineer-in-charge. Note: Punned down thickness shall only be measured and pay.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5m high from base, all as specified and as directed by engineer-in-charge.
Removing excavated material to a distance n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and as directed by engineer-in-charge.
M&L Hardcore of guage n.exc. 63mm, deposited spread & levelled in layers n.exc.15CM thick, watered & rolled/ rammed to a true surface using broken stone or boulders all as specified and as directed by engineer-in-charge.
M&L Plain cement concrete, type D2, (1:4:8, using 40mm graded stone aggregates) as in foundation, filling and mass concrete etc all as specified and as as directed by engineer-in-charge. Note: The proportioning of cement and aggregate for mixing by weight shall be as directed by the Engineer-in-charge.
M&L RCC nominal mix type A1, (1:1.5:3, using 20mm graded stone aggregates) as in foundation including raft footing foundation beam plinth beam bases for columns etc basement slab under reamed piles and mass concrete Note: The proportioning of cement and aggregate for mixing by weight shall be as directed by the Engineer-in-charge.
M&L RCC nominal mix type A1, (1:1.5:3, using 20mm graded stone aggregates) as in Columns,pillars,piers, posts and struts Note: The proportioning of cement and aggregate for mixing by weight shall be as directed by the Engineer-in-charge.
M&L RCC nominal mix type A1, (1:1.5:3, using 20mm graded stone aggregates) as in chajjas, floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like. Note: The proportioning of cement and aggregate for mixing by weight shall be as directed by the Engineer-in-charge.
M&L RCC nominal mix type A1, (1:1.5:3, using 20mm graded stone aggregates) as in beams,cantilevers, bressumers and lintels over 1.5 mtr span complete all as specified and directed by Engr-in-charge. Note: The proportioning of cement and aggregate for mixing by weight shall be as directed by the Engineer-in-charge.
M&L RCC nominal mix type A1, (1:1.5:3, using 20mm graded stone aggregates) as in slabs supported onwalls, beams and colums in floors, roofs, landings, balconies, canopies ,deck slabs and in shelves and the like complete all as specified and directed by Engr-in-charge Note: The proportioning of cement and aggregate for mixing by weight shall be as directed by the Engineer-in-charge.
Supply only water proofing compound with ISI Marking.
M&L Porbandar stone masonary, block in course, well bonded and bedded, built in CM 1:6 all as specified and as directed by engineer-in-charge.
M&L Granite work 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of granite over screed bed or bedding layer of 15 mm thick 1:6 etc. complete all as specified and as directed by Engr-in-Charge.
Formwork to sides of concrete foundations, footings,bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work;vertical or to batter,curved, as in rough finished surfaces of concrete complete all as specified and as directed by engineer-in-charge.
Formwork to sides of pillars, posts, struts, piers, columns (square, rectangular or polygonal) as in fair finished surfaces of concrete complete all as specified and as directed by engineer-in-charge.
Formwork to sides and soffits of floor or roof beams,beam haunchings, girders, bressumers, lintels, cantilevers, shelves including supports, overhangs, chajjas etc also splays between floor and beam and the like for fair finished surfaces of concrete etc complete all as specified and directed by Engr-in-charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick for fair finished surface (Horizontal or sloping) etc complete all as specified and directed by Engr-in-charge.
M&L 2nd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed by Engr-in-Charge.
S&F 100 mm long, medium weight, Stainless steel, Butt hinges (ISI Marked) complete all as specified and as directed by engineer-in-charge.
S&F 200 mm long Aluminium anodized, barrel tower bolts of extruded section of bolt (ISI Marked) complete all as specified and as directed by engineer-in-charge.
S&F 200 mm long Aluminium anodized, barrel tower bolts of extruded section of bolt (ISI Marked) complete all as specified and as directed by engineer-in-charge.
S&F 125mm long aluminium alloy handles, cast type,anodised (ISI Marked) complete all as specified and as directed by engineer-in-charge.
S&F Brass chromium plated finials for curtain rod complete all as specified and as directed by engineer-in-charge.
S&F Aluminium alloy wire cloth,0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed by engineer-in-charge.
S&F powder coated Anodised aluminium frame (minimum thickness of powder coating 50 micron) for doors, shutters, sliding windows and windows ventilators with or without rebates including joining cleats for fixing etc. complete all as specified and as directed by Engr-in-Charge.
S&F 5mm thick Sheet glass,ordinary qualityand glazing with oil putty in square n exc 0.5sq. m in each pane all as specified and as directed by engineer-in-charge.
S&F Neoprene rubber beading of U or C section suitable for 5mm thick glass fixed along with edges of aluminium glass panes of joinery, all as directed by Engineer-in-charge.
S&F UPVC, double flat / groove type, roller for sliding windows all as directed by Engineer-in-charge. Note: Rollers shall conform to the samples kept with the Engineer-in-Charge.
S&F 100mm long powder coated Aluminium starlock for sliding window shutters conforming to the samples held in the office of Engineer-in-charge.
S&F 12mm dia Mild Steel Screw bolts (Machine made) with hexagonal or square heads At one end and screwed the other or screwed both ends each screwed end to be fitted with washer and one hexagonal or square nut not exceeding 5cm long complete all as specified and directed by Engr-in-Charge
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips. etc complete all as specified and directed by Engr-in-charge.
M&L Mild steel TMT bars 6 to 8 mm dia Round Bars cut to length bent to shape required including cranking bending spirally for hooping for colums hooking ends and bending with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engr-in-charge.
All as per above item No.36.00 but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders etc complete all as specified and directed by Engr-in-charge.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc conforming to FE 410-W (Gde E- 250) Quality A complete all as specified and as as directed by engineer-in-charge.
S&F Steel work in tubular trusses, purlins, rafters, vertical poles including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 complete all as specified and as as directed by engineer-in-charge.
S&F 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc completed all as specified and directed by Engineer-in-charge.
M&L 0.9mm thick, decorative laminate, type 1, of surface finish, colour and patters as approved, fixed with approved adhesive as per manufacturer's insturctions, complete all as specified and as directed by Engr-in-Charge.
M&L 20 to 25 mm thick Machine cut Kota stone slab flooring over cement screed bed, 1:4, 20mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed by engineer-in-charge.
M&L 100mm thick Plain Cement concrete, type D-2, (1:4:8, using 40mm graded stone aggregate) as in floor as a sub base for kota stone complete all as specified and as directed by engineer-in-charge.
M&L 20 to 25 mm thick, machine cut Kota stone slab in risers of steps, skirting, dado and pillar laid over 12mm thick cement mortar 1:3, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed by engineer-in-charge.
M&L 50mm thick Plain Cement concrete, type C-1, (1:3:6, using 20mm graded stone aggregate) as in plinth protection even and smooth without using extra cement complete all as specified and as directed by engineer-in-charge.
M&L 15mm thick Rendering in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as as directed by engineer-in-charge.
M&L 15mm thick Rendering in CM 1:6 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as as directed by engineer-in-charge.
M&L 5 mm thick Rendering on ceiling in CM 1:3 on concrete surfaces finished even and smooth without using extra cement all as specified and as directed by engineer-in-charge.
M&L 20mm thick cement plaster in cement mortar 1:4 mixed with water proofing compound as in roof treatment when conc is green complete all as specified and as directed by engineer-in-charge.
M&L Preparation of new plastered surfaces of walls and applying two coats of cement based paint over a coat of primer complete all as specified.
M&L Preparation of new plastered surfaces of ceilings and applying three coats of white wash complete all as specified and as directed by engr-in-charge.
M&L Preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed by engr-in-charge.
M&L preparation of new wooden surfaces of any description not otherwise described over 10cm in width or girth & aplying two coats of synthtic enamel paint (ordinary tint), glossy finish over one coat of pink primer of all as specified.
M&L preparation of new steel surfaces of any description not otherwise described over 10cm in width or girth & aplying one coat of anti corrosive paint over one coat of anti corrosion primer of all as specified and as directed by engineer-in-charge.
Forming Contraction (Dummy) joints 50 mm deep x 10mm wide, filled with grade 'A" sealing compound
Demolition of Cement concrete (unreinforced) Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
S&F Aluminium grill with suitable aluminium anodised frame F/H section manufactured by M/s DECO GRILL as per design No DG-104, 6.5 mm thick. complete all as specified and as directed by Engr-in-Charge.
S&F 20mm dia Powder coated Aluminium anodised alloy curtain rod, of approved make with fixing brackets, all as specified and as directed by engineer-in-charge. Note: colour of curtain rod shall be approved by Engineer-in-Charge.
M&L complete removal of existing APP membrane and providing APP based membrane course roof treatment in layers with following provisions:- (i) Applying one coat of bitumen's primer polymerized primer oil based coat, evenly @ 0.3KG/Sqm as priming coat to the prepared surfaces, till the surfaces is properly impregnated and the solvent oil in the base primer shall be allowed to evaporated completely. (ii) APP Based Polymeric memberane minimum weighing 3 kg /sqm and minimum 3mm thick Reinforced with polyster non woven fabric (wt not less than 150 gms/ sqm) laid on primed surface by forced application complete all as specified and Directed by Eng-in- Charge (iii) Applying a coat of solar reflective bituminous aluminium paint @ 0.10Kg/Sqm over membrane
Supply, laying and testing ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps all as specified and directed by Engineer-in-charge.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25sqmm 4 core all as specified and as directed by engineer-in-charge.
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16250, IS 14930 ( Part I and II) for protection of underground calbes of size 63 mm outer dia with all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavation and earth work shall be measured and paid separately) Make: Rex/Poly/Gemini or equivalent.
M & L for point wiring complete with 1.5 Sqmm single core PVC Insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volt grade down through and including non metallic rigid PVC heavy duty concealed conduit, min 20mm external dia,heavy duty, but shall be increased to suitable size, as per requirement in accordance with clause 19.125 of SSR Part I, ISI marked, including conduit accessories like bends,tees,junction box etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sqmm earth wire, single core PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 3 mm thick Bakelite sheet white top cover for following: Make Finolex/Havells/ NICCO/Anchor (i) One light point controlled by one,one way 5 Amps SP switch
(ii) One Exhaust fan point controlled by one, one way 5 Amps SP switch
(iii) One 5 pin 5 Amps socket outlet on Independent board.
S&F Switch piano flush type 5 amps, single pole one way 240 volts.
S&F Socket outlet multipurpose 2 in 1,5 pin,6 Amp 240 Volts (ISI marked) complete all as specified and as directed
S&F Ceiling rose, surface type bakelite 65x17.5mm, three terminals, complete all as specified and as directed by engineer-in-charge.
S&F 20W surface/Wall mounted LED Luminaire , with high efficiency long life LED chips, CRI=80(Minimum) PF>.95, System luminous efficacy >100, Operating voltage 140V-270V including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to LED fitting Complete all as spd and as directed by engineer-in-charge. Make: Bajaj Cat No BLTRU 20W WH VIVA/ Philips Cat No BN 308C-LED-2220S-6500/ Osram cat No Luxpower Batten 19WL840.
M&L Submain wiring with two single core PVC insualated, unsheathed, FRLS, 1100 volts grade of size 4 Sqmm, multi stranded copper conductor cable drawn through and including 25 mm dia PVC non metallic rigid conduits grading heavy and the conduits accessories incl one run of green colour earth continuity conductor with 4 Sqmm multi stranded copper conductor cable, fixed to surface of wall/ roof/ ceiing complete all as all as specified and as directed by Engineer-in-charge. Make Polycab/Havells/ RR Cables
S&F MCB SP 6 Amps to 32 Amp capacity,.c series.10KA Make- Legrand/Schneider/ABB/ Siemens all as specified and as directed by Engineer-in-charge.
S&F MCB Distribution box,4way for MCB TPN, 415 Volts, double door powder coated sheet metal enclosure confirming to IP 43 including 200 amps rated bus bar fixed on existing bricks/stone wall in semi-concealed type complete all as all as specified and as directed by Engineer-in-charge. Make- Legrand/Schneider/Hager/ L&T
S&F LED street lights, 25 W, lumen output not less than 2500 lm high pressure die cast aluminum housing, 140-270V, 50 Hz, PF>0.90, including 1.2 mtr long 40/50 mm bore light grade GI pipe mounting bracket made to shape with and including MS clamps of FI 40mmX 6mm with bolts, nuts, washers and conductor to fitting with 3 core 1 sqmm PVC insulated copper cable from control box to fitting complete all as spd. Note: The quoted unit rate deemed include for painting to clamps with one coat of redoxide paint and two coats of sythetic enamel paint. complete all as directed by Engineer-in-Charge.Make:- Wipro (skyline LED)/Halonix (LUMOS-MINF)
Supply and fix Exhaust fan 300 mm sweep 240 V AC metal body fixed as per maufacturers instructions,including all accessories connected with 0.5 Sqmm copper coductor PVC insulated and PVC sheathed three core cable, complete all as directed by engineer-in-charge.Make Bajaj/Usha/Havells
M&L Earthing of electric equipments with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm burried directly in ground ( earth pit not less than 2.25 mtr deep below GL,with top edge of platenot lessthan 1.5 mts below ground level, connected to and including GI earth lead wire 4.0 mm dia by means of 02 GI bolts / nuts and washers. earth plate shall be sorrounded by packed layers of coal dust and common salt 15 mm thick each all around , bottom and top and watering pipe 20 mm dia x 2.25 mtrs heavy duty grade perforated galvanised steel top with socket and plug at bottom connected to earth plate by slit and two bolts / nuts/ washer complete all as shown in electrical plate no 3 and directed by engr in charge.GI light grade pipeup to test point / equipt the strip shall be test after carefully completion as per IS secifications complete.
M & L for point wiring complete with 2.5 Sqmm single core PVC Insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volt grade down through and including non metallic rigid PVC heavy duty concealed conduit, min 20mm external dia,heavy duty, but shall be increased to suitable size, as per requirement in accordance with clause 19.125 of SSR Part I, ISI marked, including conduit accessories like bends,tees,junction box etc fixed concealed/recessed in wall or ceiling etc including 2.5 Sqmm earth wire, single core PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 3 mm thick Bakelite sheet white top cover for following: Make Finolex/Havells/ NICCO/Anchor (i) One 3 pin 15/16 Amps on Independent Board
S & F Switch socket outlet multipurpose 6 pin 16 Amp, flush type controlled by one piano switch 250 Volt, (ISI marked) complete all as specified and as directed
S & F MCB 4 Pole,40 Amp,10 KA, C series complete all as specified and as directed. Make Legrand/Hager/L&T/Schinder
S & F MCB 4 Pole, 25 Amp, 10 KA, C series complete all as specified and as directed. Make Legrand/Hager/L&T/Schinder
K K Construction Co
roxy enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .