| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹40.7 L+₹3.9 L (10.7%)Rejected-AOC V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L2 | Rejected-AOC Other Than Lowest Bidder | |
| 3 | L3₹42.5 L+₹5.7 L (15.6%)Rejected-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L3 | Rejected-AOC Other Than Lowest Bidder | |
| 4 | L4₹44.3 L+₹7.6 L (20.7%)Rejected-AOC | L4 | Rejected-AOC Other Than Lowest Bidder | |
| 5 | L5₹48.6 L+₹11.9 L (32.3%)Rejected-AOC | L5 | Rejected-AOC Other Than Lowest Bidder |
Tender Value
₹45.6 L
EMD Value
₹91,240
Closing Date
3 Mar 2025, 6:00 pmClosed
GE CHANDIGARH
GE CHANDIGARH N AREA OLD AIRPORT CHOWK CHANDIGARH 160003
CA NO GE CHD 82 2024 25 SPL REPAIR REPLACEMENT OF EXISTING LT CAPACITOR BANK TO NEW LT PANELS AND LT CAPACITOR BANKS AND LT OVERHEAD TO UNDERGROUND AT K AREA UNDER GE CHANDIGARH
2025_MES_695025_1
GE/CHD-82/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CHANDIGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE CHANDIGARH
₹91,240
Yes
24 Mar 2025
27 Jan 2025
5 Mar 2025
27 Jan 2025
3 Mar 2025
18 Feb 2025
28 Jan 2025 - 5 Feb 2025
Amount
Dismantling insulators any type, any size complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.
Dismantling concrete poles/ struts, any size complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.
Dismantling of ACSR or AAC conductors complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.
Street light sevice bracket made of GI pipe 32 mm bore medium grade top mounted fancy type of length 1.5 mtr including bending,welding,drilling holes as required and fixing with flat iron clamps 50 x 6 mm (02 Nos), bolts, nuts, and washers and suitable reducer for connecting fitting to Steel/PCC poles complete all as specified and directed by Engineer-in-Charge.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 240 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 185 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 150 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 120 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 95 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 70 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 50 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 35 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 10 sq. mm, 4 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 16 sq. mm, 2 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 10 sq. mm, 2 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
Cable route indicator shown "LT UG cables" painted in blue colour and root of cable with arrow made of CI in suitable eleiptical shape and fixed in MS rod 12mm dia 70 cm long ( all word embosed) and embaded in PCC block of size 30 x 30 x 60cm in ground complete all as specfied and directed.
Galvanised iron tubes, `light grade', 80 mm bore, with all fittings; laid in trenches/ across roads / on pole for cable protection complete all as specified and directed. Note: Excavation, earth work etc. shall be measured and paid separately.
Galvanised iron tubes, `light grade', 50 mm bore, with all fittings; laid in trenches/ across roads / on pole for cable protection complete all as specified and directed. Note: Excavation, earth work etc. shall be measured and paid separately.
Galvanised iron tubes, `light grade', 40 mm bore, with all fittings; laid in trenches/ across roads / on pole for cable protection complete all as specified and directed. Note: Excavation, earth work etc. shall be measured and paid separately.
H.D.P.E. Double Wall Corrugated(DWC) Pipes(ISI marked) 40 mm bore SN-4 Class as per IS 16098 part II laid in trenches including jointing accessories and fittings complete all as specified and directed by Engineer-in-charge.Note: Excavation, earth work etc. shall be measured and paid separately.
Excavation in trenches in any type of soil not exceeding 1.50 meter wide and not exceeding 1.5 meter in depth; for foundation or for shafts, wells, cesspits, manholes, pierholes, etc. not exceeding 10 sq. m on plan and getting out complete all as specified.
Excavation in trenches in any type of soil not exceeding 1.50 meter wide and exceeding 1.5 meter but not exceeding 3.0 meter in depth; for foundation or for shafts, wells, cesspits, manholes, pierholes, etc. not exceeding 10 sq. m on plan and getting out complete all as specified.
Returning, filling in, including spreading, leveling, watering and well ramming in ayers not exc 25 cm thick each,excavated soil in soft/loose soil, complete, all as specified and directed by Engineer-in-Charge.
Removing of surplus soil/ excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point complete, all as specified and directed by Engineer-in-Charge.
Clean dry sand laid in trenches/ducts for bedding and cushioning to cable, 8cm in depth before laying the cable and 15 cm in depth after laying the cable including spreading, levelling and consolidation complete all as specified and directed. Note : Consolidated/punned sand shall be measured for payment purpose.
Supply and laying burnt bricks sub class "B" old size for cable protection laid flat length perpenducualr to the axis of cable complete all as specified and direted by Engineer-in-Charge.
Supply, transporting to site, erecting and fixing in truly verticle position, steel tubular swaged pole, type 410-SP-31 (9.0 metre long) complete finial taper plug, bolts, nuts, scerws as specified, CI base plate including drilling holes and painting with two coats of aluminium paint externally, providing 30cm wide alternate strips with white and black synthetic enamal paint upto 1.2m height from ground level and numbering the pole (with black and white paint), undergruound part of the pole shall be painted with black bituminous paint complete all as specified and directed. Note: Excavation, earthwork, PCC foundation/coping, cross arm, bracings, clamps shall be measured and paid separately.
Plain cement concrete (1:4:8) type D-2,using 40 mm graded stone aggregate as in foundation of poles, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in coping of poles, rounded or chamfered on edges with and including using necessary use and waste of formwork for fair finished surface complete all as specified and directed by Engineer-in-Charge.
Street light PVC Junction Box of size 250x200x150mm with locking arrangement suitable for 01 No MCB SP 6 Amp complete with suitable size of cable glands & MS clamps nuts, bolts & washers etc complete all as specified
Earthing with 600x600x6mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including G.I. Strip of size 32x6 mm by means of bolts,nuts and check nuts and washers of galvanised steel to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per electrical plate No. 3 of SSR Part I-2009 including chamber made up of PCC 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover, 20mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement incl excavation and earth work in any type of soil and testing complete all as specified and directed. Note :- GI Strip more than 7.5 mtr will be measured and paid separately
Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including 4 mm galvanised earth lead wire as earthing lead by means of bolts, nuts, check nuts and washers made out of galvanised iron, 20 mm bore (medium grade) GI pipe for protection of earthing lead, 20 mm bore (medium grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 5 of SSR Part-I (1991). NOTE : 1. Earth chamber shall be constructed at least 1.50 metre away from the top of earth electrode, the earth pit and pipe for watering shall be provided in slanting manner. 2. :- Unit rate includes for protecton pipe 20mm and GI earth wire 4mm from top of earth plate upto 7.50 metre above ground level.
Note: For the purpose of arriving at lumpsum amount, the amount of credit schedule i.e Sch 'A' section II (i.e Rs 1,29,140.00 shall be deducted from the total amount arrived.
Total of Schedule 'A' Rs.
Electromech Engineers (BID ID -3247778)
GS Engineers (BID ID -3248309)
M/S RAGBIR ENGINEERING SERVICES (BID ID -3253735)
Bharat Enterprises (BID ID -3253341)
M/S BALWINDER SINGH (BID ID -3248369)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .