Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹97.9 LAccepted-AOC | ₹97.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹98.4 L+₹49,000 (0.50%)Rejected-AOC C O ANIL CHANDRA SAHA DOTMA P O P S DOTMA DIST KOKRAJHAR BTC ASSAM PIN 783347 | DOTMA | KOKRAJHAR | ASSAM | 783347 | ₹98.4 L+₹49,000 (0.50%) | L2 | Rejected-AOC L2 |
Tender Value
₹97.9 L
EMD Value
₹2.0 L
Closing Date
24 Apr 2023, 2:00 pmClosed
The Addl. Chief Engineer cum Director, PWD BTC
O/o the Addl. Chief Engineer cum Director, PWD, BTC, Kokrajhar.
Const. of Additional Class Room at Kalaguru Bishnu Rabha Degree College (KBRD), Orang in Udalguri District.
2023_BTC_30369_1
ACE-35/TECH/UDL(RB)/IFB/18-19
Open Tender
Civil Works - Building
Works
365 days
Udalguri
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
₹2.0 L
Yes
2 May 2023
5 Apr 2023
24 Apr 2023
5 Apr 2023
24 Apr 2023
5 Apr 2023
5 Apr 2023 - 24 Apr 2023
Amount
2.8. Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
11.2. Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand,with common burnt clay non modular bricks.
4.1.6. 1:3:6 (1 Cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources).
11.3. Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate
5.22. Steel reinforcement for R... Work inluding sraitaning, leaning utting and bending to proper shape plaing in position and binding up to plinth level. 5.22.1 Mild steel and Medium Tensile steel bars
5.9. Centering and shuttering inluding strutting, propping etc end removal of the 5.9.1 Foundation Footing, base of column etc. For mass concrete.
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers.
5.9.6 Columns, Pillars, Posts & Strat
5.9.3. Suspended floors, roofs, landings, balconies and access platform
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and.... 5.1.3 1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size de rived from natural sources).
5.2. Reinforced cement concrete work in walls (arty thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 5.2.2 1:1.5:3 (1 coment: 1.5 coarse sandfzone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
6.1. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand).
2.25. (a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
6.13. Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement : 4 coarse sand)
13.3.Providing and applying plaster of puris paty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
13.5. 15mm thick cement plasdter in single coat on rough side of single or half brick wall 13.5.10 1:4(1 Cement :4 Coarse Sand).
13.4. Applying one coat of water thinable cement primer of approved brand and manufacture on wall surface . 13.43.1. Water thinable cement primer.
13.4. Finishing wall with water proofing cement paint of approved brand and manufacture of required shade. 13.44.1. New work (Two or More coat @ 3.84
9.1. Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.3 Kiln seasoned and chemically treated hollock wood.
9.5. Providing and fixing panelled or panelled and glazed shutters for doors. windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Kiln seasoned and chemically treated hollock wood. 9.5.2.1 35 mm thick
9.55. Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete: 9.55.2 100 x 58 x 1.90 mm
9.63. Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete. 9.63.3 150 x 10 mm
9.66. Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete
9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc.
11.41 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sund) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.1 Double charge vitrified tile polished finish of size. 11.41 A1 1 Size of Tile 600x600 mm.
13.48. Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.801 ltr/ 10 sqm of approved brand and manufacture
TOILET BLOCK 2.8.Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches not exceeding 1.5 m in width or 20 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the exceed soil and disposal of surplus excavated soil as directed, within a lead of 50 m 2.8.1 All kinds of soll.
11.2. Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar,including fitting joints with Jamuna sand, with common burnt clay non modular bricks.
4.1.6. 1:4:8 (1 Cement: 4 coarse sand (zone-III) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources).
11.4. 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
5.22. Steel reinforcement for R…. Work including sraitaing, leaning utting and bending to proper shape plaing in position and binding up to plinth level. 5.22.6.TMT bar Fe500D or more. 5.22.1 Mild steel and Medium Tensile steel bars.
5.9.Centering and shuttering inluding roaming propping etc end removal of the same….. 5.9.1. Foundation Footing, base of column etc. For mass concrete. 5.9.5 Lintels, beams, plinth beams. Girders frammers and cantilevers
5.9.6. Columns, Pillars, Posts & Strut
5.1. Providing and laying in position spectified grade of rainforced cement concrete, excluding the cost of centering, shuttering, and rainforcement-All work up to plinth level: 5.1.3 1:2:4 (1 cement: 2 coarse sand (zone-III) divired from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
5.2. Reinforced cement concrete work in walls ( any thickness) including attached pilasters, buttresses, plinth and string course filvers columns pillars, piers abutments, posts and struts etc. above plinth level up to floor five level excluding coast of centernig shuttering finishing and reinforcement: 5.2.2 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sourece : 3 graded stone aggregate 20 mm nominal size derived from natural sources )
6.1. Brick work with common burnt clay FPS (non modular) bricks of class designation 7.5 in foundation and plinth in 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand).
2.25. Excavating, supplying and filling of local earth ( including royalty ) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc . complete.
6.13. Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2. Cement mortar 1:4 ( 1 cement :4 coarse sand).
13.5. 15 mm thick cement plaster in single coat on rough side of single or half brick wall 13.5.1. 1:4. (1 Cement : 4 Coarse Sand).
13.43. Applying one coat of water thinable cement primer of approved brand and manufacture on wall surfaces. 13.43.1. Water thinnable cement primer.
13.44. Finishing wall with water proofing cement paint of approved brand and manufacture of required shade. 13.44.1.New work (Two or More coat @ 3.84 Kg/10m2
9.2. Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross hands and face veneers on both faces of shutters. 9.20.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
9.1. Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.3 Kiln seasoned and chemically treated hollock wood.
12.1. Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.3 0.63 mm thick with zinc coating not less than 275 g/m²
9.95. Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 9.95.3 100x75x4 mm
9.96. Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete: 9.96.2 250x16 mm
9.97. Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: 9.97.2 250x10 mm
9.100. Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: 9.100.1 125 mm
17.1. Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
17.6. Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. /PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required: 17.6.1 Single squatting plate with 5 litre P.V.C. automatic flushing cistern
18.7. Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 18.7.2 20 mm nominal dia Pipes.
18.15 Providing and fixing brass bib cock of approved quality : 18.15.2 20 mm nominal bore
18.16 Providing and fixing brass stop cock of approved quality : 18.16.2 20 mm nominal bore
SEPTIC TANK 2.8. Earth work in excavation by mechanical means (Hydraulic excavators/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m 2.81 All kinds of soil.
4.1.6. 1:3:6 (1Cement: 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 40 mm nominal size derived from natural sources ).
5.22. Steet reinforcement for R... Work inluding sraitaning, leaning utting and bending to proper shape plaing in position and binding up to plinth level. 5.22.6. TMT bar Fe500D or more. 5.22.1 Mild steel and Medium Tensile steel bars
5.1. Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 5.1.3 1:2:4 (1 cement: 2 coarse sand (zone-111) derived from natural sources: 4 graded stone aggregate 20 mm nominal size de rived from natural sources)
6.1. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement: 4 coarse sand)
13.5. 15 minthick cement plaster in single coat on rough side of single or half brick wall 13.5.1. 1:4.4(1 Cement: 4 Coarse Sand) ( C ) In cement mortar 1:5
19.32. Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.32.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
ELECTRICAL WORK 1.10:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core etc. as required 1.10.1 Group A
1.10.2 Group B
1.1.3 Group C
1.14 - Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2 2 x 2.5. sq. mm + 1 x 2.5 sq. mm earth wire
1.14.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire
1.14.4 2 x 6 sq. mm + 1 x 6sq. mm earth wire
1.21:- Supplying and fixing following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1.21.1 20mm
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc, as required. 1.24.1 5/6 A switch
1.24.4 3 pin 5/6 socket outlet
1.25:- Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.33:- Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connections etc, as required
1.34 - Supplying and fixing brass batten/ angle holder including connection etc. as required.
1.44:- Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
2.3:- Supplying and fixing following way, single pole and neutral, shee steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.2 8 way, Double door
2.10:- Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole
2.10.3 Double pole
2.14:- Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB) having a sensitivity current 30 mA int he existing MCB DB complete with connections, testing and commissioning etc. as required. 2.14.2 40A
5.1:- Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
5.17 - Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
7.1:- Laying of one number PVC insulated and PVC sheathed / XL power cable of 1.1 KV grade of following size direct in grol including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.1.1 Upto 35 sq. mm
MR-1:- Supplying with including fitting fixing Of ceiling fan etc. as directed by the Deptt.
MR-2:- Supplying with including fitting fixing Of tube light etc. as directed by the Deptt. (Bajaj make) Code No. 11249 luminaries type 18 WH white.
MR-3- Supplying with including fitting fixing of LED Bulb 12 Watt. Etc. as directed by the Deptt. (LED home lighting Solution.)
MR-4:- Supplying and fitting fixing 2 H.P. Single phase Centrifugal Mono block Pump set sync speed 2900 rmp. Model No. KDS-213 with DOL Starter Control & switch gear (/ BCH/L&T/Siemens/ equivalent make). With all accessories complete as required and as directed by the department.
MR-5:- Supplying fitting fixing 1.1 KV gd aluminium conductor XLDE insulated armoured PVC outer sheeted conforming to IS- 7098 (pt-1)(1988 with latest amendment as applicable make "Mescab" Considering 100 mt length. 4.00 sq.mm 2 Core U.G Cable
MR:-6:- Supplying with fitting fixing of 15L storage Geyser Crompton made (Amica, Black, with)
MR-7:- Supplying fitting fixing tubular pole SL No-749 Meterial code 101076 HSN code 7308 GI Tubular pole SP 22 (8.50 mt) APDCL Rate 2022
MR:- 8- Supplying fitting & fixing of street light arm bracket veekay light.
MR-9:- Supplying fitting fixing 1.1 KV gd aluminium conductor XLPE insulated armour PVC outer sheathed, conforming to IS-7098 (Part-I) 1988 with latest amendment as applicable make "Mescab" Considering 100 meter length.
Payment to be made to the APDCL Authority for load Security.
Arjun Saha
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .