Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹84.1 LAccepted-AOC VILLAGE PO KANOH TEHSIL BARSAR DISTT HAMIRPUR HP | HAMIRPUR | HIMACHAL PRADESH | 174304 | 1 | Accepted-AOC Accepted | |
| 2 | 2₹86.0 L+₹1.9 L (2.23%)Rejected-AOC VILLAGE PO KANOH TEHSIL BARSAR DISTT HAMIRPUR HP | HAMIRPUR | HIMACHAL PRADESH | 174304 | 2 | Rejected-AOC Rejected | |
| 3 | 3₹90.1 L+₹6.0 L (7.08%)Rejected-AOC VILLAGE BIDDI P O DARWAR TEHSIL DHARMPUR DISTT MANDI H P | 3 | Rejected-AOC Rejected | |
| 4 | 4₹1.0 Cr+₹17.1 L (20.3%)Rejected-AOC LAXMI BAZAER TEHSIL JOGINDERNAGAR DISTT MANDI HP | MANDI | HIMACHAL PRADESH | 175001 | 4 | Rejected-AOC Rejected | |
| 5 | 5₹1.0 Cr+₹17.9 L (21.3%)Rejected-AOC | 5 | Rejected-AOC Rejected |
Tender Value
₹1.2 Cr
EMD Value
₹1.5 L
Closing Date
26 Jun 2023, 5:00 pmClosed
Executive Engineer
Jal Shakti Division Dharampur Bharari
PLJ and testing of rising main and SE of pumping machinery Under JJM
2023_HPIPH_75145_1
2961-3010 dated 17.06.2023
Open Tender
Civil Works - Water Works
Item Rate
180 days
Bharari
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,500
EE Dharampur Bharari
₹1.5 L
Drampur
27 Sept 2023
17 Jun 2023
27 Jun 2023
17 Jun 2023
26 Jun 2023
17 Jun 2023
23 Jun 2023
Amount
Excavation in foundation and trenches in earth work upto all depth in all kinds of soil such as pick work jumper work, blasting work, chiselling of soft /hard rock where blasting is prohibited in all leads and lifts and including trimming of sides levelling of bed to correct grade stacking the excavated soil in 15cm.layers when required into plinth sides of foundation including consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed in all leads including lifts and soring/strutting timbering and dewatering where ever required as per thr direction and to the entire satisfaction of the Engineer-in-charge.
Laying, jointing and testing in trenches (to level or grade) of GMS pipes jointed with 1% joint flanged & remaining butt weld 99% joints of below diametre conforming to IS 1239-1990 (Part - I) with latest upto date amendments of grade and wall thickness as specified below, suitable to withstand required hydraulic test pressure in randum length 4m-6m with plain ends and jointed with MS Flanges conforming to IS 6392-1971(Latest upto date amendments) and welding of flanges as per IS 816-1969 with electrodes as per IS 814-1991 including required number and size of MS nuts and bolts as per IS 1369-1967 and compressed asbestos fibre jointing gaskets sheet not less than 3.00 mm in thickness as per IS 2712-1998. The welding of flanges to be done on both faces in two layers to make the joints leak proof and to entire satisfaction of the Engineer-in-Charge.The laying of pipes conform to IS 5822-1994 and as per CPHEEO manual and will include all operations such as cutting, welding and jointing including flushing, cleaning and hydraulic testing complete in all respect. Excavation in trench, providing & welding of M.S. Flanges and butt welded joint shall be measured and paid for seperately. (Labour rate)
100mm dia Heavy Class, wall thickness 5.4mm, FT-28/17 (From RD 0 to 925m)
Providing, laying, jointing and testing in trenches bevelled ended BIS marked GMSERW pipes of various grade fully Butt welded conforming to IS/ISO:3183-2007, L210 or A of below mentioned grade in item as per dimensions, weight and test pressure mentioned there in code (mill tolerances to be restricted within 3%) in random lengths of 6 to 7 mtrs including the cost of fabrication of bends by butt welding from parent tube as required at site. The welded joints and welding of pipe will be down as per IS:816-1969 with electrodes as per IS:814-1991 of make Adwani/Orelon (Adore)/ESAB. The laying & jointing of pipe should conform to IS:5822-1994 (earth work in trenches and butt welded joints except in bends to be measured and paid for separatly) The pipes and specials shall have out side coating with galvanised as per BIS 4736, the galvanisation is done by the manufacturing firm itself complete in all respect as per direction and to the entire satisfaction of Engineer-in-Charge. (Earth work, flanged joint & butt welded joint shall be measured & paid separately)
200mm dia GMSERW pipe grade L210 or A having wall thickness 4.80mm, FT-17/5
Providing and welding M.S. flanges @ 1% of joints conforming to following Table at suitable point, conforming to IS 6392-1971 (Latest with upto date amendments) with plain end GMS/MSERW pipe in requsite number of layers on both faces to make the joint leak proof The welding of flanges should conform to IS:816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364. including cost of gasket sheet nuts & bolts. The thickness of gasket sheet not less then 3.00mm conforming to IS 2712-1998. The work shall be done to the entire satifaction of Engineer in Charge with in all leads and lifts.
100mm dia, wall thickness 5.4mm, FT-28
100mm dia, wall thickness 5.4mm, FT-17
200mm dia GMSERW pipe grade L210 or A having wall thickness 4.80mm, FT-17
200mm dia GMSERW pipe grade L210 or A having wall thickness 4.80mm, FT-5
Providing circumferencial Butt welded joints by electrical arc welding to following dia MSERW/GMS pipe, welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5mm to 6.3mm of Advani Oerlikon (Adore)- CITOJET/ESAB make, conforming to IS 814-1991, at site of work complete in all respects, including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
100mm dia Heavy Class, wall thickness 5.4mm
200mm dia GMSERW pipe grade L210 or A having wall thickness 4.80mm
Providing and fixing double flanged cast steel Sluice valve of following dia of Kirloskar/Leader or any other approved make conforming to BS: 1414/API-600 Class ASA-150 including M.S. flanges table-28 as per IS 6392-1971 including welding of flanges and capable of with standing of nominal seat pressure 21.00 Kg/cm² with upto date amendments including carriage within all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge.
100mm dia
200mm dia
Centrifugal Pump:- Supply of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar make conforming to BIS 1520-1980) pump (Latest with up to to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling sliperring squirrel cage screen protected drip proof electric induction motor of standard make such as Kirloskar/ NGEF/Cromption conforming to IS 12615-2018 and should be energy efficient IE2 complaint and TEFC type ( latest with upto date ammendments) it should include the cost of bearings, nuts & bolts,m painting etc. and shall be and suitable for operation on the date given below:
SITE CONDITION Total Head 174.33 mtrs Discharge required 6.67 LPS each set. No. of Pump required. 2.00 Nos sets (1 act as stand bye) Length of R/main 925.00 mtrs. Dia of R/main 100 mm dia Location of the site of installation of machinery-The site is located at a distance of 20 Km from Dharampur at Tasli Nallah by road & 0 KM on head load The Altitude of :- The Altitude of place is 1002 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:- 415+ Type of water and its Clear Water Charactristics of water:- a) Ambient Temperature b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 7.5 -- e)Total Solid Mg/Lts)PH Value -- No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% R. M.P. of Pumping RPM(or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Providing ICTP Main Switch with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
M.C.C.B. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
R.C.C.B. 100 Amp. of Havell/MDS/INDETEC make as per IS: 2516-1977 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part - V ) 1983 (Latest edition) with up to date amendments of suitable rating.
Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part - IV ) 1983 ( Latest edition) with up to date amendments of suitable rating.
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 100 Amp.
ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments.
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
Capacitor of L&T/Bajaj/Assian/Crompton make as per IS:2834 -1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of suitable rating according to HP offered including cables as per relevant ISI code (of Siemens/Glocter/IEC make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064 (Part - II) 1978 with upto date amendments (Range to be specified by the tenderer)
Providing suitable Star Delta starter of L&T/Havells/M.E.I make as per IS:8544 (Part - IV ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
Providing double flanged Cast iron sluice valve of Leader/Kirloskar make of 100 mm dia for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments. Class PN-1.6
Providing double flanged Cast steel sluice valve of Leader/Kirloskar make and size of 80 mm dia (ASA-300). and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS : 1414 / API - 600 .
Providing double flanged Cast steel reflux valve of Leader/Kirloskar make and size of 80 mm dia. and capable of with standing nominal seat pressure of 52 kg/cm2 as per: BS : 1868 / API - 600 .
Providing double flanged Cast steel 100mm non return valve of Leader/ Kirloskar make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 52 kg/cm2 as per BS : 1868 / API - 600 . .
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
Installation of all the items appearing at Serial No. 9 to 15 as per the systematic drawing attached with the tender documents ( Drg.No.1)
Providing and fixing double flanged 125 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 125 mm dia Min. length = 15 mtr.
(ii) Delivery pipe 80 mm dia -do- = 5 mtr.
(iii) Common Header 100 mm dia -do- = 10 mtr.
and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/GICO/Grandly/National make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
(i) Motor side: 6 mm2 Min length = 20 mtrs.
(ii) Supply side: 10 mm2 Min. length =10 mtrs.
Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Supply of submersible pump of KSB /Calama/Johnston/SU/Kirloskar make conforming to BIS: 8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water prrof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrut bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
SITE CONDITION Total Head 77.50 mtrs Static Head 67.30 mtrs Discharge required 20.22 LPS each set. No. of Pump required. 2Nos 1set act as stand bye. Location of the site of installation of machinery: The site is located at a distance of 6 Km from Dharampur at Kandapattan-Bahri & 0.10 Km on head load The Altitude of :- The Altitude of place is 592 mtrs above MSL Type of Current:- AC three phase supply with RateVoltage:- 415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 5.00 HP -- e)Total Solid Mg/Lts)PH Value -- f) Other -- Static head in mtrs 67.30 mtrs. Length of R/main 1580 mtrs Dia of Rising main 200 mm dia. No of working hours. 8 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping 2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Supply of star delta starter 63 AMP of reputed make i.e MEI/Kilburn or of approvrd make conforming to BIS 8544 -( Part - )1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filing suitable for 40 HP motor.
Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches with HRC fuses of Havells/L&T/standard /cromption make for required motor of 63 Amp capacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments.
Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutral conforming to IS: 8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendmentsof suitable rating.
MCB/MCCB of suitable capacity of Havells/standard/MDS/Jyoti/Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto date amendments with neutral linked under voltage release.
3 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts.
50 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications.
Supply of Kirloskar /leader make cast steel double flanged ( swing check type) reflux valve having bye pass arrangement and 125 mm dia (ASA-150) and capable of with standing nominal seat pressure of 21 kg/cm2 as per: BS : 1868 / API - 600.
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side Suitable sizes.
Supply of Leader /Kirloskar make cast steel double flanged (swing check type) reflux valve having bye pass arrangement and 200 mm dia (ASA-150). of rising i.e. 200 mm for withstanding nominal seat pressure of 21.00 Kg/Cm 2 as per IS :1868/API-600
Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced by tender.
Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of required capacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and other electrical equipment’s.
Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments.
Providing and laying delivery pipe 125 mm dia. and common header 150 mm dia Heavy class as per IS:-1239-2004 Part-I jointed with MS flanges of table -5 as per IS: 6392-1971 (upto a length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge.
Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of siemens/Gloster/ICC make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer).
Supply of suitable cable for water level guard
Supply of supporting clamps.
Supply of cable clips of required size.
Erection of all equipment from Sr. No. 21 to 33 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
Anurag Deep
Kuldeep kumar sharma
M/ Shiv Shakti Traders
Rajat Attri
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .