Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC | L1 | Accepted-AOC Considered for acceptance being lowest | |
| 2 | L2₹12.0 L+₹1.3 L (11.9%)Rejected-Finance | L2 | Rejected-Finance Rejected for acceptance being not lowest | |
| 3 | L3₹12.0 L+₹1.3 L (12.1%)Rejected-Finance 234 PKT 8 SEC 12 SURYODAYA APARTMENT DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L3 | Rejected-Finance Rejected for acceptance being not lowest |
Tender Value
Refer Docs
EMD Value
₹25,600
Closing Date
1 Dec 2020, 6:00 pmClosed
GE (AF) JAMNAGAR NO.2
GE (AF) JAMNAGAR No.2, Air Force-II, Udhyog Nagar, Jamnagar - 361004
PROVN OF CERTAIN WK SERVICES FOR INSTL OF X-RAY BAGGAGE, SWG LINE NEAR BY BLDG NO P-937, 938 AND PROVN OF OBSTACLE TRG FACILITY, WALL MTD FANS AT MORBI AND STN GYM AND ELECT GEYSER WITH CERTAIN MISC E/M WKS AT SMC AT AF STN UNDER GE AF JAMNAGAR NO2
2020_MES_392296_1
8270/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
JAMNAGAR
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE (AF) Jamnagar No.2
₹25,600
Yes
19 Jan 2021
3 Nov 2020
2 Dec 2020
3 Nov 2020
1 Dec 2020
17 Nov 2020
Amount
Surface Excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Soft/ Loose soil complete all as specified and directed.
Excavating in trenches n exc 1.5 m wide and n exc 1.5m in depth for foundation etc n exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches n exc 1.5 m wide and n exc 1.5m in depth for foundation etc n exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in Hard / Dense soil complete all as specified and directed.
Excavating in trenches n exc 1.5m wide and n. exc 1.5m in depth for foundation, laying pipes cables, manholes etc n exc 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
Excavation in post holes in soft /loose soil (or similar holes) each n exc 0.5 cu m , getting out, returning in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface as in any type of soil complete all as specified and directed
Excavation over areas not exceeding 1.5 Mtr deep and getting out in Soft/ Loose Soil complete all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out in any type of soil complete all as specified and directed.
Excavating over areas, exc 1.5 m deep but n. exc 3.0 m deep and getting out in any type of soil complete all as specified and directed.
Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick using excavated soil all as directed
Removing excavated material exc 250 m but n.exc 500m and depositing where directed at a level n. exc 1.50M above the starting point complete all as specified and as directed.
Removing excavated material exc 500m but not exc 1.5KM and depositing where directed above the starting point etc complete all as specified.
Removing excavated soil to a distance exc 1.5 Km but n.exc 2 Km and depositing at a level not exceeding 1.50m above the starting point all as directed at site.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L Cement Concrete type D-2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete all as directed
M & L for cement concrete type C2 1:3:6 (40 mm graded stone aggregate) in foundation, filling and mass concrete all as specified and directed.
M&L plain cement concrete type B2 1:2:4 (using 40mm graded stone aggregate) as in foundation filling and mass concrete all as directed.
Form work to sides of concrete foundation, footing bases of column , rafts and raft beams side and soffits of foundation and plinth beam and similar work vertical or to better for flat rough finished surfaces of concrete all as directed.
Form work to sides of pillars, posts struts, piers column and stanchions of rectangular /square for rough finished surface of concrete.
Use & waste form work to sides of beams, lintel beams for rough finished surface of concrete complete all as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between flooris and beams etc, complete all as specified and directed.
Formwork to faces of walls flat rough finished surfaces of concrete all as directed
Form work to soffits of suspended slabs such as roof slabs, floor slab, landing and similar work as specified and directed,
M & L for RCC M-30 design mix (using 20 mm graded stone aggregate) in footings including rafts, footings, foundation beams, plinth beams; bases for columns and mass concrete complete all as specified and directed.
M & L for RCC M-30 design mix (using 20 mm graded stone aggregate ) in columns, pillars, piers, posts and struts complete all as specifed and directed.
M&L for RCC M-30 design mix (using 20 mm graded stone aggregate) in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified.
M & L for RCC M-30 design mix (using 20 mm graded stone aggregate) in beams, cantilevers, lintels over 1.5M span complete all as specified and directed.
M & L for RCC M-30 design mix (using 20 mm graded stone aggregate ) roof slab supported on walls, beams and column in floors, balconies etc complete all as specifed and directed.
Taking down cement plaster any thickness complete all as specfied and directed
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 for including finishing the surfaces even and smooth without using extra cement all as diredted
M & L for rendering 15 mm thick in CM 1:4 using on fair faces of brick work or concrete surfaces and finsish the surface even and smooth without using extra cement all as specified and as directed.
M&L for plastering in CM 1:6, 15 mm thick in two coats (10 mm under coat plus 5mm finishing coat) on external concrete or stone surfaces of bldg by using WPC as per manufacturer's instruction and finishing the surface seven and fair. Note : Water Proofing Chemical shall be measured and paid separately
M & L for mild steel TMT bars 10mm dia and over out to length/bent to shape required inlcuding cranking , bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified and directed.
All as per item No 32 above but 6mm to 8mm dia complete all as specified and directed.
All as per item No 32 above but 5mm dia and over upto and including 10mm dia as in stirrups, spacere and binders complete all as specified and directed.
S&F Steel work in frame works square /circular pipes or angle irons as roof trusses, perlins and ladders etc. including special shaped, washers etc complete using ERW or induction butt welded tubes conforming to IS-1161, grade St -240
Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases,splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars,stiffeners, gusset plates, etc. Fe-410-W (Gde-E-250) quality-B as specified and directed
S&F MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of grade Fe-290 (Gde E-165) complete all asspecifiedand and directed.
M&L for mild steel bolts, purpose made, exc 12 mm & n.exc 20 mm with hexagonal or square head on end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 30 cm long and applying on shop coat of Zinc Chromate primer paint (incl preparation of surface)
M & L applying 2 coat of synthetic enamel paint over one coat of red oxide primer including prepartion of new steel surfaces of any description all as specified and directed.
M&L 50 mm thick 2nd class hard wood boarding clean sawn with butt joints supplied and fixed with nails/screw in any situation(except flooring and skirting)
M&L 2nd class hard wood in scantling wrought timber framed and fixed to chin up bar etc complete all as specified and directed
S&F steel cable of any size as per requirement including stays, hook etc for fixing to MS pipe/Ground with PCC foundation all as directed. Note: PCC will be measured and paid separately.
M&L precast cement concrete block masonry with solid block PCC 1:5:8 mix (using 20 mm graded stone aggregate) exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
M & L for hard core with using broken stone boulders of gauge n exc 63mm deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true suface complete all as specified and directed.
M & L for 75 mm thick cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base and like etc complete all as specified and directed.
M & L 50 mm thick cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate), as in floor including finished surfaces even and smooth without using extra cement .
Supply fabricate & fix in position anodized aluminum powder coated (minimum thickness of powder coating 15 to 25 micron) door shutter with frame, partly glazed with 5 mm thick tinted glass and partly paneled with 9 mm thick MDF board with both side decorative laminated including rubber bead joining cleat for fixing in position, aluminum door handle 150 mm size, aluminum barrel tower bolt 200 mm size etc all as specified below complete all as specified and directed. (a) Frame (top & side) section shall of size 101.60 x 44.75 x 2.4 mm (Section No 14021) (b) Vertical Members of shutter Section shall be be of size 85.00 x 44.45 x 2.00 mm (Section No 19560) (c) Top Members of shutter Section shall be be of size 83.50 x 44.45 x 2.00 mm (Section No 19581) (d) Lock rail (Middle member) of shutter Section shall be be of size 150.00 x 44.45 x 3.00 mm (Section No 19596) (e) Bottom Members of shutter Section shall be of size 150.00 x 44.45 x 3.10 mm (Section No 19584) (f) Glazing clip for securing glass of shutters shall be of 0.80 mm thick (Section No 19370). Note: Section No given above are of make JINDAL, Contractor may use similar section of other make mention in Appx B
Supply fabricate & fix in position aluminum powder coated (minimum thickness of powder coating (15 to 25 micron of approved colour) three track window ( two shutters glazed & one shutters wire gauge) with frame, glazed with 4 mm thick tinted glass and, wire gauge with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm including rubber bead joining cleat for fixing in position, concealed type lock for all three shutter, PVC roller etc all as specified below, complete all as specified and directed. (a) Frame (top & side) section shall of size 92.00 x 31.75 X 1.50 mm (Section No 20831) (b) Frame (bottom) section shall of size 92.00 x 31.75 X 1.50 mm (Section No 20832) (c) Top & side Members of shutter Section shall be be of size 18.00 x 40.00 x 1.55 mm (Section No 20738) (d) Shutter Interlock Section shall be be of size 18.00 x 40.00 x 1.45 mm (Section No 20737) (e) Bottom Members of shutter Section shall be be of size 18.00 x 40.00 x 1.55 mm (Section No 20736) Note: Section No given above are of make JINDAL, Contractor may use similar section of other make mention in Appx B.
M & L for new plastered surfaces on wall and applying a coat of cement base white cement and alkali resistance primer and applying two coats of oil bound distemper complete all as specified and directed
S&F Coloured Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 15mm thick screed in CM (1:4) complete all as specified and directed.
All as per item no.50 above but as in skirting etc laid over and including 10 mm thick backing coat in CM 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match of tiles.
Supply only integral water proofing chemical @ 200 ml/ bag of cement complete all as specified and as directed. Make: FOSROC, Dr. Fixit or equivalent approved by GE.
M&L for preparation of new plastered surfaces of walls and applying 2 coat of weather proof exterior emulsion paint in camouflage pattern (Apex Ultima) by diluting of water (as per manufacturer direction). A gap of 24 hours should be given between two coats, over a coat of primer on plastered/un-plastered surface should be allowed to cure completely such as surfaces applying one coat of exterior wall primer (X2) by thinning a litre of primer with one ltr of water allow the primer coat for four hours including cleaning and ensure that the surface to be painted is free from any loose paint, complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 MPA as in roof covering/cladding to wall, fixed with self tapping screws specified and directed by Engr-in-Charge.
M & L for cement concrete 1:2:4 type B1 (20mm graded stone aggregate) in copings, kneelers, apex stones , bed plares, kerbs, water troughs and the like including slightly rounded or chamfered angels and throating, as directed complete.
M&L for cement concrete 1:3:6 type C2( 20 mm grade stone aggregate) as in surface channels and drains complete all as secified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
M & L for providing 1:2:4 type B1 precast cement concrete for cover slabs set in CM 1:6 (for man holes etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified.
M & L Framed work such as grills, gratings, etc with ends of bars houldered and or riveted, or forged into spikes : framed guards bars : barred iron doors, ladders : framed balusters: walk ways: railings, framework of water tanks and simiars work conforming to FE 290. Gde-E-165 complete all as specified and directed.
M&L for RCC NP-2 drain pipe of dia 200 mm laid in trenches and jointed complete all as specified and directed,
M & L Concrete bed in PCC 1:4:8 Type D2 to drain pipes of dia 200 mm including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M & L for broken brick coarse aggregate 63 mm as in filling of soakage well complete all as specified and directed.
Point wiring with PVC insulated and unsheathed multi stranded FRLS copper conductor single core 1.5sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories including joint boxes, terminal boxes and modular metal boxes etc complete along with copper earth wire PVC insulated & unsheathed multi stranded (FRLS) copper conductor cable of size 1.5sqmm as continuous earth wire connected to common earth and earth dolly complete all as specified and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete as specified and as directed.
One 3 pin socket outlet 5 Amps on the same board with other switches
One 3 pin 5 Amp socket out let controlled by one switch on independent board
Point wiring for power point with PVC insulated and unsheathed multi stranded FRLS copper conductor single core 2.5sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories including joint boxes, terminal boxes and modular metal boxes etc complete alongwith copper earth wire PVC insulated & unsheathed multi stranded(FRLS) copper conductor cable of size 2.5 sqmm as continuous earth wire connected to common earth and erth dolly complete all as specified and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete as specified and as directed.
M & L for Switch piano flush type single pole, one way 5 Amp 230 V complete all as specified and directed.
M & L for Socket outlet 2 in 1, 3 pin, 5A complete all as specified and directed.
M & L for Switch piano flush type single pole, one way 15 Amp complete all as specified and directed.
M & L for Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type
M&L for Ceiling rose ceiling rose , 2 to 3 terminal PVC/ polycarbonate , isolated body type suitable for AC 230 volts complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire mm as 4.0mm dia by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate no.3 including earth pit in PCC concrete 1:2:4 type B-1,Cast iron cover 10 mm thick hinged to CI frame ,excavation and earth work in any type of soil and including protection pipe 15mm dia and water pipe GI tubing 20mm light grade with funnel and wire mesh connected to earthling test point complete all as specified and directed. Note: (i)Rates are inclusive of 7.5m long GI earth wire 4.0mm dia (ii)Rates of CI frame, RCC Pit cover, funnel and wire mesh included in the cost of item.
Supply and fix wall mounted fan 400mm sweep, 3 blades Aerodynamically designed and blanced blade with 3 speed control, air delivery of 95m3/min, rated speed 2000 revolution per minute, power consumption 110W suitable for 230 volts, 50Hz supply complete with all accessories and connection upto electrical point complete all as specified and as directed. Make : Havells / CG / Bajaj
Supply & Fixing 5 star rated electric storage water heater (vertical type) 25 Ltr, 230 V, AC, Single phase power input 2000W, standing loss in KWH 24 (hours) 45 c 0.511 KWH with and including connecting fastners nuts not less the 100 mm with suitable nut, bolt & washers grouted in walls with complete masonary work for peoper mounting of Geyser fastning bolts etc as directed as site reqmt and making necessary inlet and outlet water connection as well as electric connection including testing on load for entire satisfaction. Make:havells/Venus/Bajaj/Usha
S & F stop valve 15 mm bore heavy duty fancy type chromium plate with long sunk and cup connected in wall clamps as per site reqmt for cold water inlet & hot water outlet connection complete all as specified and as directed.
S & F Bib cock 15 mm bore heavy duty fancy type chromium plate with long sunk and cup connected in wall clamps as per site reqmt for WHB purpose complete all as specified and as directed.
Supply & Fixing GI pipe 15 mm bore medium grade with all fitting such as unions, tee, nipple, short length and socket for connecting and fixed complete to walls and ceiling or laid in floors all as specified and as directed. Make: Prakash surya/Jindal.
Supply & Fixing Vent GI pipe 15 mm bore light grade complete with all accessories all as specified and as directed.
M & L for cutting hole not exceeding 150 sqmm into through brick wall built in cement mortar or stone wall/ RCC wall built in lime mortar/ concrete for passing inlet pipe of geyser through walls or as per site reqmt all as directed including making good the disturbed surfaces.
M & L for cutting and screwing existing steel tubing 20/15 mm dia bore size for alterations/ additions required for connection with geyser including connection using required accessories complete all as directed.
S & F PVC connection 15 mm size with PTMT nuts 600 mm long for hot or cold water to and from geyser complete all as specified and as directed.
SIBS CONTRACTOR
RACON CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .