| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹26.2 LAccepted-AOC BLOCK B WARD NO 34 SURYASEN COLONY HARI MANDIR ROAD PO SILIGURI TOWN PS NEW JALPAIGURI DIST JALPAIGURI W B PIN 734004 | DARJEELING | WEST BENGAL | 734004 | L-1 | Accepted-AOC Being L1 bidder | |
| 2 | L-2₹28.7 L+₹1.8 L (6.62%)Rejected-Finance BANKIM CHANDRA ROAD HAKIMPARA SILIGURI DIST DARJEELING PIN 734001 W B | JALPAIGURI | WEST BENGAL | 734001 | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹30.0 L+₹3.1 L (11.4%)Rejected-Finance 24B JYOTISH ROY ROAD KOLKATA 700053 | KOLKATA | WEST BENGAL | 700053 | L-3 | Rejected-Finance Being L-3 | |
| 4 | L-4₹31.0 L+₹4.1 L (15.4%)Rejected-Finance NIL | L-4 | Rejected-Finance Being L-4 | |
| 5 | L-5₹31.0 L+₹4.2 L (15.5%)Rejected-Finance NH 31 GAIRKATA PO SAKOAJHORA DIST JALPAIGURI W B PIN 735212 | JALPAIGURI | WEST BENGAL | 735212 | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
25 Dec 2023, 6:00 pmClosed
GE (NORTH) BINNAGURI
GE North Binnaguri Post Binnaguri Dist Jalpaiguri West Bengal PIN - 735232
REPAIR TO ROOF TREATMENT, SUNKEN TREATMENT, WALL PLASTER, SLOPED ROOFING, TOILETS, SANITARY FITTINGS ETC AND E/M REPAIRS AT CERTAIN LOCATIONS OF MARRIED ACCOMMODATION IN NORTH ZONE UNDER GE (NORTH) BINNAGURI
2023_MES_630035_1
NIT No. 8701 / 40 / 2023-24 / 12 / E8
Open Tender
Civil Works
Item Rate
270 days
BINNAGURI CANTONEMNT
Class D Category a (i)
8 documents required · 8 mandatory
₹500
GE (NORTH) BINNAGURI
₹80,000
Yes
3 Feb 2024
27 Nov 2023
27 Dec 2023
27 Nov 2023
25 Dec 2023
11 Dec 2023
Amount
Taking down chowkats or frames exc 1.5 sqm but n.exc 4 Sqm (without taking off shutter from the frame) each including builders hardware and removing from the site including dismantling brick work for hold fasts etc complete all as specified and as directed.
Taking down chowkats or frames n.exc 1.5 sqm (without taking off shutter from the frame) each including builders hardware and removing from the site including dismantling brick work for hold fasts etc complete all as specified and as directed.
Taking down shutters of any description exc 1 Sqm and n.exc 2.00Sqm each including builders hardware and removing from site complete all as specified and as directed.
S& F factory made Pressed steel frames confirming to relevant IS, having profile of size 105 x 60 mm, 1.25 mm thick MS Sheet for doors with one or more rebates including necessary supply and fixing lugs, lock strike plate, etc. 100 mm size hinges, with one shop coat of zinc chromate primer and fixing complete all as specified and as directed.
S&F of pressed steel framed for door with one or more rebates including necessary fixing lugs, hinges, lock strike plates, size of frame 125 X 60 mm and 1.25mm thick including 100 mm size hinges, with one shop coat of zinc chromate primer and fixing complete all as specified and as directed.
M&L for PCC type C-1, 1:3:6 using 20mm graded aggregate as in bed block for fixing of hold fast, filling concrete in frame filling, gaps in between glazed & fly proof steel window, cills, railing up to 60 cm in height etc including necessary form work as required complete all as specified and as directed.
S&F of solid PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour printed PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing complete all as specified and as directed.
S&F factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification with wood free EPS complete all as specified and as directed.
S&F 30mm thick hard wood factory made, Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S&F factory made 35mm thick 2nd class hard wood gauged and skeleton shutter open rebated and prepared to received gauge etc (without sash bars) for fly proof door shutter, edges of framing plain, chamfered or rounded, fitted with cut of any mitered beads for securing gauge etc, size of members of shutter as specified in SSR Part-I section 8 clause No.8.23 (a) and fitted to chowkats complete all as specified and as directed.
Taking down and Refixing of shutter of any description n.exc 1 Sqm and n.exc 2 Sqm each of same opening doing resecuring or easing & adjusting without taking down complete all as specified and as directed.
S&F stainless steel butt hinges, medium weight of size 100mm complete all as specified and as directed.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed.
Supply & fixing aluminium anodised extruded fabricated type handle 150mm long complete all as specified and as directed.
S&F aluminium alloy anodised sliding door bolt 250 mm long with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section complete all as specified and as directed.
S&F factory made pressed steel windows of standard size and section as shown on HQ CE Siliguri Zone Drg No CESZ/2018/TD-07, Sheet 1/3 to 3/3 with double shutter i.e glazed & wire gauged shutter including all fittings and fixture like MS hold fast, box hinges, handles, MS tower bolts, stoppers, MS guard bar/grill etc complete including one shop coat of anti corrosive zinc chrome primer complete all as specified and as directed. Notes:- (a) Rate quoted shall be deemed to be including of all fittings fixtures . (b) Glass, wire mesh, MS guard bar/grill and painting shall be measured and paid separately under relevant items of this schedule. (c) PCC (1:3:6) type C1 to be filled in chowkats frame and paid under relevant item of schedule. (d) The drawings referred above are available in the office of Engr-in-Charge and can be refried in the office working hours if required. .
S&F powder coated aluminium window sliding type three track (2 glazed & one gauze shutter) aluminium sections weighing not less than 1.25kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazing cleats, rubber packing, screws, handle, locking arrangement and 5.5mm thick plain/tinted glass and aluminium mosquito proof gauge including taking down of old existing steel window and making good disturbed surface of wall complete all as specified and as directed.
S&F steel ventilator top hung shutter including hinges, steel peg stay, fixing lugs etc complete with or without glazing bars including taking down of old steel ventilators of any size as per drawing No. SZ/TD/219/ 99, sheet No. 1/2 to 2/2 dated 17 Jun 1999 complete all as specified and as directed.
M&L for mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
M&L for preparation of new or previously untreated steel and Iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of Synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L for preparation of new or previously undecorated wooden surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of Pink primer complete all as specified and as directed.
Hacking out old broken unserviceable glass panes (any thickness, size, quality or description) for metal frame including punching or drilling out old glazing pins/spring clips and providing & fixing new one complete all as specified and as directed.
S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed.
S&F 3 mm thick figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 Sqm in each pane complete all as specified and as directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed.
S&F in repairs stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed.
Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
M&L for brick work with fly ash bricks old size straight or curved on plain exc mean radius built in cement mortar 1:6 complete all as specified and as directed.
All as item No. 30 here in before but except bricks complete all as specified and as directed. Note : The serviceable bricks obtained from demolition shall be reused.
Taking down cement plaster on wall of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for 20 mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm & 10mm) mixed with water proofing compound in top layer 200 ml per bag of cement or as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified and as directed. Note : Water proofing compound shall be measured and paid separately.
M&L for rendering 5 mm thick cement plaster on ceiling surfaces in cement mortar (1:3) finished even and fair without using extra cement complete all as specified and as directed.
M&L 15mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surface finished fair and even (without using extra cement) complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L for preparation of newly plastered surface of wall and applying two coat of colour/white wash to match the colour of existing adjacent surface complete all as specified and as directed.
M&L for preparation of newly ceiling plastered surfaces and applying three coats of white wash on wall complete all as specified and as directed.
M&L for preparation newly internal wall surfaces with one coat wall putty and applying two coats of distemper oil emulsion complete all as specified and as directed.
M&L for preparing of old surfaces of walls and applying one coat of distemper oil emulsion complete all as specified and as directed.
M&L for preparing of old surfaces of walls and applying two coats of colour wash complete all as specified and as directed.
M&L for preparation of old ceiling plastered surfaces for applying one coat of white wash on wall complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises including taking down cement plaster complete all as specified and as directed.
M&L for non skid coloured joint free ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but n. exc. 0.18 Sqm, in floors etc. set and jointed in neat cement slurry over 15mm thick screed bed or bedding layer in CM (1:6) as in floor and pointed in whiter or coloured cement to match as in floor complete all as specified and as directed.
M&L for non skid coloured joint free ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but n. exc. 0.18 Sqm, in skirting etc. set and jointed in neat cement slurry over 10mm thick backing coat in CM (1:4) as in floor and pointed in whiter or coloured cement to match as in floor complete all as specified and as directed.
M&L for 15 to 18 mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms, corner shelf, flat shelf and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including 15 mm thick cement plaster (1:4) including rounding the exposed surfaces of granite complete all as specified and as directed.
M&L for glazed ceramic coloured tiles/digital elevation tiles in vertical surface 300x600x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed white or colour cement to match complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces to receive a wall tiles as backing coat using cement mortar 1:4 complete all as specified and as directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 15 mm bore complete all as specified and as directed.
S&F of tubes, medium grade, 15mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and as directed.
Refixing of old steel tubing and connections in new or old position (wall, ceiling, floors, etc) of 15 mm bore complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing etc and making good, cutting not exceeding 10 cm girth in brick walls complete all as specified and as directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 20 mm bore complete all as specified and as directed.
S&F of tubes, medium grade, 20 mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and as directed.
Refixing old steel tubing and connections in new or old position (walls, ceiling, floors, etc) complete all as specified and as directed.
S&F in repairs 15 mm dia bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S&F in repairs 15 mm bore fancy type bib taps long body (two in one) cast copper alloy 15 mm bore with fancy chromium plated screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F in repairs concealed stop cock CP, cast copper alloy fancy type with long shank and cup for 15mm pipe complete all as specified and as directed.
S&F in repairs PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
S&F in repair CP health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible tube and ABS wall hook in cluding making connections and fixed in position complete all as specified and as directed.
Supply and fixing for brass chromium plated fancy type towel rail 600 mm long complete all as specified and as directed.
S&F in repairs of chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
S & F in repairs Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size including CP waste coupling, PVC connection 450 mm long, waste pipe & removing the existing Basin, cutting for and pinning ends of brackets or erecting stand complete all as specified and as directed.
S&F in repairs 15 mm bore pillar taps, swan neck type with standard size capstan head, cast copper alloy, chromium plated, screwed down high pressure with or without lettered ‘HOT’ or ‘COLD’ long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
S&F vitreous china squatting pan "Orissa" pattern size 580x440mm white with integral foot rests(excluding flushing cistern and flush pipe) with 'P' or 'S" trap front or back inlet etc including connection to trap and flushing pipe and provision of lime concrete bedding complete all as specified and as directed in repairs including demolition of existing one complete all as specified and as directed.
Supply & fixing in repairs vitreous china wash down water closet pedestal pattern white excluding fixing bolts, flushing cistern and flush pipe complete but including PVC seat cover with aluminium/PVC hinging devices & EWC Jet chromium plated with 1.00 mtr long PVC connection pipe etc complete all as specified and as directed.
Supply & fixing in repair PVC low level twin flushing cistern 10 ltr capacity sleek having weight not less than 1.80 KG including PVC bend, supporting brackets and complete accessories white colour complete all as specified and as directed.
M&L for Cast iron floor trap, 100 mm dia with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.
S&F in repair 15 mm dia brass chromium plated angle cock with flange complete all as specified and as directed.
S & F grating doom 125mm dia with waste hole of PTMT (min wt 40 gms) complete all as specified and as directed.
Taking down PVC/AC pipe of any dia & any description including all fittings complete all as specified and as directed.
S&F 110 mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall or laid in floors complete all as specified and as directed.
S&F 75 mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall or laid in floors complete all as specified and as directed.
S&F 110mm dia PVC SWR bends of any radius with out access door complete all as specified and as directed
S&F 110mm dia PVC (SWR) junction single 'T' equal or unequal with access door complete all as specified and as directed.
S&F 110mm dia PVC (SWR) branch piece, single ‘Y‘ equal or unequal complete all as specified and as directed.
Dismantling/demolition of RCC fins/parapets of any size incl. cutting down rusted reinforcement complete all as specified and as directed.
M&L for making good the dismantling surface of RCC with slab/chajja CM 1:3 & providing drip course 25 mmx10 mm deep with CM 1:3 at edges of RCC slab/chajjas etc complete all as specified and as directed.
Taking down tarfelt with cement plaster from roof surfaces and lowering and removing the same to a distance exc. 50m and n. exc. 100m including roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and as directed.
M&L for 10mm thick screed bed or bedding layer in cement mortar (1:4) mixed with WPC in order to maintain proper slope over existing roof surfaces for applying roof treatment, finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound shall be measured and paid separately.
M&L for providing, cement concrete type B1 1:2:4 using 20 mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edges, padding to roof etc complete all as specified and as directed.
M&L for water proofing coating with polyurethane based water proofing liquid membrane of approved make to be applied by brush with multi coats with minimum dry film thickness of 1mm and shall be cured by reaction with atmospheric moisture to give a tough elastomeric water proof membrane complete all as specified and as directed. Note: The above treatment will be carried out by authorised applicator of approved firm/company.
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top :- (a) Applying bituminous primer @ 0.4 ltrs per Sqm over plastered surfaces of roof including parapet surface. Note: Bituminous primer shall be "TANK MASTIC" manufactured by "EMUFALTE" manufactured by M/s Texsa India Ltd. or equivalent as approved by GE. (b) Over the priming coat laying one layer APP based polymembric membrane of approved manufacturer 3 mm thick weight not less than 3.5 Kgs per Sqm reinforced with non woven polyester fabric weight not less than 150 gms per Sqm. Polymeric membrane shall be taken to a height of 60cm (min) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. Notes:- (i) Laying APP based polymeric membrane shall be done torch on method or as per manufacturer's instructions. (ii) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturer's instruction. (iii) Applying two coats of Aluminium paint over APP membrane. (iv) Cutting groove in brick wall 75 mm wide and 65 mm deep and shopping horizontal face of groove with cement mortar 1:3
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
S&F for pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof, to wall, ridges fixed with self tapping screws complete all as specified and as directed.
S&F Mild steel work in tubular trusses as in post, roof trusses, purlins rafters including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161- 1979 grade St.-240 etc complete all as specified and as directed.
M&L for water proofing treatment to sunken floor with the following course of treatment/ specification:- (i) Cleaning top surface of floors /slabs and laying 50 mm thick (avg) PCC of grade M10 (Nominal mix) , mixed with WPC as per manufacturer's instruction laid in slope 1:20 towards spouts including coveting corners (ii) 15 mm thick plastering in CM (1:4) on sides mixed with WPC as per remanufacturer's instruction. (iii) Applying 1st layer of slurry @ 0.488 kg / sqm mixed with acrylic based polymer modified cementious compound @ 0.253 kg /sqm This layer shall be allowed to air cured for 4 hrs . (iv) applying 2nd layer of slurry @ 0.242 kg/sqm mixed with acrylic based polymer modified cementenous compound @ 0.126 kg/sqm. This layer shall be allowed to air cured for 4hrs followed with water curing for 48 hrs.(v) Applying a coat of industrial bitumen 85/25 penetration @ 1.50 kg/sqm on plastered and concrete surfaces (vi) Providing 150 micron thick polyutethene paint in two coats (each of 75 micron measured dry on dry surface over a coat of PU primer including preparation. (Make of PU primer - Dek guard EP -302 of M/S Fosroc or equivalent approved brand by GE. Make of PU paint - Dek guard PU or equivalent approved brand by GE. (vii) 2 Nos 32mm bore GI medium grade 450mm long spout ,to be provided through external wall to drain out accumulated water.(vii) Sunken floor shall be tested for water tightness by filling water for 72 hrs before and after treatment work is carried out and ensure that no leakage /seepage exists (ix) Sunken portion shall be filled with lean concrete of grade M7.5.
INTERNAL ELECTRIFICATION Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten/ conduit/ gutties/ wooden boards/ switches/ sockets/ regulators/ light fittings etc and separating the serviceable items like fan regulators and light fittings for re-use under respective items and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and as directed.
M&L for concealed conduit point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including PVC conduit of adequate size with all accessories (including cutting chases & making good the disturbed surface to its original specification) including MS sunk box, 3mm thick hylam sheet top cover fixed by means of brass machine screw and cap washer including size 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor cable as earth continuity conductor connected to main switches/DB's or common earth dolly for one light point controlled by one, one way switch complete all as specified and as directed.
All as per item No 91 here in before but for one ceiling fan / exhaust fan point controlled by one, one way switch and regulator complete all as specified and as directed.
All as per item No 91 here in before but for one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and as directed.
All as per item No 91 here in before but for one 3 point 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and as directed.
All as per item No 91 here in before but for one bell point controlled by one, bell switch 5 Amps complete all as specified and as directed.
All as per item No 91 here in before but for light point controlled by two way switch Amps complete all as specified and as directed.
All as per item No 91 here in before but using 2.5 Sqmm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 Amps switch socket combination point including running of 2.5 Sqmm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and as directed.
S&F switch piano single pole flush type 5 Amps, 230 volts one way complete all as specified and as directed.
S&F switch piano single pole flush type 5 Amps, 230 volts two way complete all as specified and as directed.
S&F bell push flush type 5 Amps 230 Volts complete all as specified and as directed.
S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and as directed.
S&F switch socket combination 2 and 3 Pin, 5/6 Amps, multipurpose flush non shutter, non inter locking type white ivory finish with complete all as specified and directed.
S&F switch piano single pole flush type 15 Amps, 230 volts one way complete all as specified and as directed.
S&F of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 Volts flush type complete all as specified and as directed.
S&F ceiling rose, bakelite, surface type, 220/240 Volts, three terminals complete all as specified and as directed.
S&F deluxe type electronic fan regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and as directed.
S&F lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and as directed.
S&F in repair switch piano single pole flush type 5 Amps, 230 Volts one way complete all as specified and as directed.
S&F in repair switch piano single pole flush type 5 Amps, 230 Volts two way complete all as specified and as directed.
S&F in repair socket outlet 2 in 1, 5 Pin 5/6 Amps white ivory finish flash type complete all as specified and as directed.
S&F in repair switch socket combination 2 and 3 Pin, 5/6 Amps, multipurpose flush non shutter, non inter locking type white ivory finish with complete all as specified and as directed.
S&F in repair of socket outlet 2 in 1, 5 Pin 5/15 Amps, multipurpose 230 Volts flush type complete all as specified and as directed.
S&F in repair ceiling rose, bakelite, surface type, 220/240 Volts, three terminals complete all as specified and as directed.
S&F in repair deluxe type electronic fan regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and as directed.
S&F in repair lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and as directed.
S&F in repair call bell "Ding Dong", 230 Volt single phase complete all as specified and as directed.
S&F LED white glass lamp 1x9 Watt 230V Base-22 complete all as specified and as directed.
S&F LED white glass lamp 1x20 Watt 230V Base-22 complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 130 mm x 180 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 120 mm x 170 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 230 mm x 280 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour round type of size 80 mm dia including taking down existing unserviceable complete all as specified and as directed.
S&F IP 20, class I, LED light 1x18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and as directed.
S&F of bulk head luminaire with B22 base holder suitable for 9 Watt LED inverter type bulb light IP66 grade, with and including 9 watt LED (or nearest next higher wattage) lamp (LED Bulb with B22 base 900 Lumens in normal mode and 450 lumens in power back up mode, charging time 8-10 Hrs and around 4 Hrs Power backup with inbuilt surge protection of 3 KV) (or nearest next higher wattage) and connecting up with and including PVC insulated 3 core of size 0.75 Sqmm copper conductor from ceiling rose to terminal block of light fitting including necessary taking down the old unserviceable fitting complete all as specified and as directed.
S&F energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete including removal of old unsv fitting complete all as specified and as directed.
S&F IP 20, Class I, LED Mirror light fitting 1 x 10 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete including 01 No 10 W LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size including taking down the old unserviceable fitting complete all as specified and as directed.
M&L for sub main wiring with 2 runs of 6.00 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 6.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in 25mm thick PVC rigid non-metallic concealed conduit with and including taking down unserviceable sub main, complete all as specified and as directed. Note: Two runs of sub main wiring cable alongwith one run of earth wire with and including PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with 2 runs of 4.00 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 2.5 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in 25mm thick PVC rigid non-metallic concealed conduit with and including taking down unserviceable sub main, complete all as specified and as directed. Note: Two runs of sub main wiring cable alongwith one run of earth wire with and including PVC conduit pipe shall be measured as one unit length.
S&F sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 Volts double door with magnetic locking system complete including removal of old unserviceable sheet metal enclosure complete all as specified and as directed.
S&F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 Volts double door with S&F MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 8 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, earth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface including removal of old unserviceable sheet metal enclosure complete all as specified and as directed.
S&F in replacement of MCB, Triple pole & neutral 63 Amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed.
S&F in replacement of MCB, single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with complete all as specified and as directed.
S&F in replacement of MCB, single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete with complete all as specified and as directed.
M/s. MD IRSHAD
M/S SINHA ENTERPRISE
SHRI PRADEEP PARIK
samrat saw mill and joinery workshop
S.N. GHOSH AND CO.
L. B. SHARMA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .