Executive Engineer
O/O of Exe. Engineer, KSHB, Kattappana
NEW LIFT INSTALLATION AT COMMERCIAL COMPLEX, KATTAPPANA- General Electrical Work
2026_KSHB_864001_2
01/KSHB/IDK/2026-27
Open Tender
Electrical Works
Item Rate
90 days
Kattappana
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,760
₹40,125
Yes
14 Aug 2026
14 Aug 2026
24 Aug 2026
14 Aug 2026
21 Aug 2026
14 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1VERTICAL TRANSPORTATION SYSTEM | |||||
| 1.001 | OD24281/2026-2027:Supplying, installation, testing and commissioning of MR lift 8 passenger (480 kg) lift having contract speed of 1 MPS,serving different floors in the existing lift shaft as per detailed specifications enclosed and as under: (i) Speed : 1 MPS (ii) Floors : G,1,2,3,4,5,6 (iii) Travel : 21 meters (approx.) (iv) Stops & Opening : 7 (v) Controller : A.C. variable voltage & variable frequency (vi) Automatic rescue device complete with dry maintenance-free batteries as required. (vii) Operation: Microprocessor/micro controller -based single automatic push button / simplex selective collective / duplex collective selective with or without attendant. (viii) Power: 415 V, 3 phase, 50 Hz, 4-wire system (ix) Type of Doors: (a) Car: Automatic power operated, telescopic horizontal sliding stainless steel scratch-proof surface (moon rock finish) (b) Landing Doors: SS doors finished of approved shade(Preferably brush finish). (C) floor selection switches shall be braille lift compliance , grab rail and all other facilities for differently disabled people shall be included,(d)Flooring should be granite. Including all liaison work related to electrical inspectorate and KSEBL,all statutory fees will be reinbursed after submitting original receipt ,on the buy back agreement making good the damage all works should be carried out as per the Direction from the engineer in charge . Lift Pit size 1.87*1.75 meter. | - | each | - | - |
| 1.002 | OD24285/2026-2027:Dismantling the existing damage lift including motor,rope,rail,counterweight,dead weight ,spring,panels,I/O units ,electrical components and all scraps etc valuating and take it back including all transportation and dismantling charge. | - | each | - | - |
| 1.003 | OD100419/2026-2027:Supply, Installation, Testing and Commissioning LIFT PANEL 1 Fabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV Main panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.Incomer - 63A, FP MCB Isolator - 1No. 63A, 415V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh - 1Set Class B+C / Class 1 + 2 Surge arrestor device with necessary rating MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Outgoing 40A, 100mA, FP RCBO - 1 No. 16A, 30mA, DP RCBO - 1 No. 16A, 415V, 16 kA best conductivity Al DP bus bar with SMC supports, heat shrinkable sleeves etc complete as required - 1 Set 10A, 10kA, SP MCB - 1 No.6A, 10kA, SP MCB - 3 Nos. | - | each | - | - |
| 1.004 | 90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp | - | metre | - | - |
| 1.005 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) | - | metre | - | - |
| 1.006 | 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for
following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
grade as required.4 X 10 sq. mm (25mm) | - | set | - | - |
| 1.007 | OD100575/2026-2027:Supply installation,testing and Commissioing of bulk head fittings with 10watt LED bulb in lift well case using necessary accessories and givingconnection etc. as required. | - | each | - | - |
| 1.008 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). | - | each | - | - |
| 1.009 | 1.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group B | - | point | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_1464850.xls
BOQ • 0.31 MB
doc.pdf
Tender Documents • 1.66 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].